MEP-PCA-RG2 Roof and Gutter Components Power Connection Kit
“
Product Information
Specifications
- Model: MEP-PCA-RG2
- Product Name: Roof and Gutter Components Power Connection
Kit - Tools Required: Diagonal cutters, screwdriver, needle-nose
pliers, utility knife, heat gun or propane torch
Product Usage Instructions
Important Instructions
Ensure proper installation of the power connection kit to
prevent shock or fire. Follow all installation instructions
carefully.
Kit Contents
ITEM | QTY | DESCRIPTION |
---|---|---|
A | 1 | Grounding screw and nut |
B | 1 | Grommet |
Installation Steps
Maintenance Instructions
Regularly check the connections and components for any signs of
damage or wear. Replace any damaged parts immediately.
FAQ
Q: What should I do if the heat-shrink tubes overheat during
installation?
A: Overheating heat-shrink tubes can produce fumes. Ensure
adequate ventilation and avoid charring or burning the tubes.
Follow proper heating techniques.
“`
MEP-PCA-RG2
Roof and Gutter Components Power connection kit
Installation, Operation & Maintenance Instructions
TOOLS REQUIRED: Diagonal cutters; screw driver; needle-nose pliers; utility knife; heat gun or propane torch
(Junction box not included)
IMPORTANT INSTRUCTIONS
POWER CONNECTION KIT
KIT CONTENTS
ITEM QTY DESCRIPTION
A
1
Grounding screw and nut
B
1
Grommet
C
1
D
1
E
1
F
2
END SEAL
G
1
Sealing fitting Black heat-shrink tube ½”x 1½” Green/Yellow heat-shrink tube ¼” x 5½” Black heat-shrink tubes 1/8″ x 5½”
Black heat-shrink tube 1/2″ X 1½”
H
1
Black heat-shrink tube
WARNING – The contents of the component kit must be installed correctly to ensure proper operation and to prevent shock or fire. Read these important warnings and carefully follow all the installation instructions.
· To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed use a ground fault protection device. Arcing may not be stopped by conventional circuit breakers.
· Component approvals and performance are based on the use of specified parts only. Do not substitute parts or use vinyl electrical tape. · The black heating-cable core is conductive and can short. It must be properly insulated and kept dry. · Damaged bus wires can overheat or short. Do not break bus wire strands when preparing the cable for installation. Bus wires will short if they contact
each other. Keep bus wires separated. · Heat-damaged components can short. Use a heat gun or torch with a soft yellow low-heat flame; not a blue focused flame. Keep the flame moving to
avoid overheating, blistering, or charring the heat-shrink tubes. Avoid heating other components. Replace any damaged parts. · Leave these installation instructions with the user for future reference.
WARNING – Overheating heat-shrink tubes will produce fumes that may cause irritation. Use adequate ventilation and avoid charring or burning.
SAVE THESE INSTRUCTIONS
ENM-4437-00
1
2
3
4
Work opening through ground braid at jacket, bend back, and pull out inner core. Twist braid into a pigtail.
5
6
Strip inner jacket as shown.
7
Leave ½” inner jacket covering core.
Cut inner core at end as shown. Roll back with pliers and separate the bus wires from the core.
8
Install the 1/8” x 5½” heat-
shrink tubes over bus wires.
Remove core material from bus wires. Re-twist bus wires.
Heat-shrink the tubes into position, keeping the heat source moving from side to side.
9
10
Install black 1/2” x 1 1/2″ heat-shrink tube as shown.
11
12
Slip green/yellow tube over braid and shrink.
13
Install sealing fitting into
14
junction box.
While tube is still hot, pinch with pliers between bus wires to seal; hold for 10 to 15 seconds.
Slide sealing fitting components to position at core sealer.
15
Insert heating cable through sealing fitting and tighten components into place.
16
Connect heating cable leads to power wire leads (ground braid pigtail to ground wire).
Install weathertight cover.
END SEAL
TOOLS REQUIRED: Diagonal cutters; needle-nose pliers; utility knife; heat gun or propane torch.
1
2
Strip inner jacket as shown.
Do not cut into inner jacket
Unravel ground braid and trim at outer jacket; cut back.
3
4
Heat-shrink 11/2″ heat-shrink tube in place with 3/8” over end of heating cable. Remove heat. Squeeze end with needle nose pliers. Hold for 10 to 15 seconds.
Heat-shrink 4″ heat-shrink tube in place with 3/8″ over end of smaller heat-shrink tube. Remove heat, resqueeze at end of smaller heatshrink tube, then squeeze at end of outer heat-shrink tube. Hold for 10 to15 seconds.