Marathon Lighting ML-WM-8083, ML-WM-2089-120W Wall Pack
Product Information
Specifications
- Brand: hon Lighting
- Type: Wall Pack Light
- Installation: Junction Box
Product Usage Instructions
Wall Pack Installation:
Mount the wall pack on the wall to inhibit any moisture from attaching to the bolts.
Junction Box Installation:
- Unscrew the 2 screws on the right with a screwdriver.
- Unplug the male and female connectors and ground terminal, then remove the main body.
- Fix the back cover on the junction box and introduce the cables into the cavity of the back cover.
Hose Installation:
- Connect the cable to the corresponding L/N/GND of the driver.
- Plug in the male and female connectors and connect the ground terminal.
- Tighten the screws with a screwdriver.
- Insert the hose into the side hole and route the cable.
FAQ
- Q: How do I ensure proper cable connection during installation?
- A: Make sure to connect the cable to the corresponding L/N/GND of the driver and securely plug in the male and female connectors before tightening the screws with a screwdriver.
- Q: What should I do if moisture is present around the wall pack?
- A: Ensure that the wall pack is mounted securely on the wall to prevent moisture from accumulating around the attachment bolts.
Specification
- Operating temperatue: -104° C to 122° C
- Input voltage range: 120-277V, 50/60 HZ
Note: Add a bead of exterior grade silicone sealant around the perimeter of the wall pack on the wall to inhibit any moisture from attachment bolts.
Product Overview
Installation Instruction
Junction Box Installation
- Unscrew the 2 screws on the right with a screwdriver
- Unplug the male and female connector ground terminal, remove the main body
- Open the G½ blocking cover at the back cover and drill through ABCD four holes
- The back cover is fixed on the junction box, and the cables in the box are introduced into the cavity of the back cover
- Connect the cable to the corresponding L/N/GND of the driver
- Plug in the male and female connectors and connect the ground terminal
- Tighten the screws with a screwdriver.
Hose Installation
- Unscrew the 2 screws on the right with a screwdriver
- Unplug the male and female connectorand ground terminal, remove the main body
- Open the side G½ blocking cover, drill through the three holes of EFG, and fix the back cover.
- Insert the hose into the side hole and route the cable
- Connect the cable to the corresponding L/N/GND of the driver
- Plug in the male and female connectors and connect the ground terminal
- Tighten the screws with a screwdriver.
General Wiring Diagram
CAUTION: Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
Connecting panels to AC source supply:
All units must be individually connected to the AC supply.
- Black = Line
- White = Neutral
- Green = Ground
Surge Protection Device Diagram
Emergency Battery Backup Wiring Diagram
Photocell Diagram
Microwave sensor wiring Diagram
Documents / Resources
![]() |
Marathon Lighting ML-WM-8083, ML-WM-2089-120W Wall Pack [pdf] Installation Guide ML-WM-8083, ML-WM-2089-120W, ML-WM-8083 ML-WM-2089-120W Wall Pack, ML-WM-8083 ML-WM-2089-120W, Wall Pack, Pack |