MAJOR TECH DNS16 16A Day/Night Sensor with Timer Instruction Manual

DNS16 16A Day/Night Sensor with Timer

Specifications:

  • Function: Day/Night Sensor with Timer
  • Rated Current: 16A Max
  • Rated Voltage: 220-240V AC
  • Frequency: 50/60Hz
  • Ambient Light: Sensor for automatic light
    adjustment
  • Working Humidity: Suitable for indoor and
    outdoor use
  • Installation: Easy to install in existing
    electrical systems
  • Built-in Timer Settings: Allows customization
    of timing settings
  • Working Temperature: Suitable for various
    temperature ranges
  • Warranty: Check manufacturer’s warranty
    details
  • Standards: Complies with relevant safety
    standards

Product Usage Instructions:

Installation:

  1. Ensure the power supply is switched off before
    installation.
  2. Mount the DNS16 device in a suitable location where it can
    detect ambient light.
  3. Connect the device to the existing electrical system following
    the provided wiring diagram.
  4. Secure the device in place and ensure all connections are
    tight.

Setting Timer:

  1. Press the timer button to enter timer setting mode.
  2. Use the up and down arrows to adjust the desired time
    settings.
  3. Confirm the settings by pressing the timer button again.

Day/Night Sensor:

The sensor automatically detects ambient light levels and
switches the connected load on or off accordingly.

Maintenance:

Regularly clean the sensor to ensure proper functioning. Check
for any loose connections or signs of wear.

Frequently Asked Questions (FAQ):

Q: Can I use the DNS16 sensor outdoors?

A: Yes, the DNS16 sensor is suitable for both indoor and outdoor
use.

Q: How do I reset the timer settings?

A: To reset the timer settings, press and hold the reset button
for 5 seconds until the display clears.

Q: What is the warranty period for the DNS16 sensor?

A: Please refer to the manufacturer’s warranty details provided
with the product for information on the warranty period.

INSTRUCTION MANUAL
DNS16
16A Day/ Night Sensor with Timer

1. INTRODUCTION The DNS16 day-night sensor automatically adjusts lighting based on ambient light levels and preset schedules. It features adjustable lux sensitivity and customizable timer settings. With a robust 16A rated current and IP66 waterproof rating, it integrates easily into both new and existing Installations. Ideal for outdoor lighting, streetlights, and security systems, it enhances energy efficiency and security by activating lights only when necessary. Its unique wall-box design with six knockouts allows for flexible installation, Simple yet effective, the DNS16 is the perfect solution for automated lighting control. Installation should be performed by a qualified professional.

2. SPECIFICATIONS
Function Rated Current Rated voltage Frequency Ambient Light Working Humidity Installation Built-in Timer Settings Working Temperature Warranty Standards

Range 16A Max 220-240V AC 50/60Hz <3 – 50 Lux (Adjustable) <93% RH Surface Mount on Walls or Ceilings 1, 2, 3, 4, 5, 6, 7, 8, 9 Hours & Dusk to Dawn -20°C to 40°C 5 years – Limited IEC 60669-1, IEC 60669-2-1 AS/NZS 60669.1, AS/NZS 60669.2.1

3. INSTALLATION ADVICE Note: Y There should be no obstruction affecting natural light in front of the sensor. Y There should be no swaying objects in front of the sensor. Y Avoid installing the sensor under the light or in the place where light will irradiate to the sensor.
4. CONNECTION
WARNING: Danger of Death Through Electrical Shock Y Must be installed by professional electrician. Y Disconnect power source. Y Cover or shield any adjacent live components. Y Ensure device cannot be switched on. Y Check power supply is disconnected.

1. Ensure power supply is turned off 2. Loosen the screws and remove the front cover (refer to fig. 1) 3. Remove the necessary knock outs for 1 x for power supply and 1 each for up to 5 separate loads (refer to figures 2
& 3) 4. Fit the necessary glands to the removed knock outs (refer to figures 4& 5) 5. Identify the ideal placement and use the back housing of the sensor as a guide, to ensure proper placement. 6. Mark and drill holes for the screws and fischer plugs and secure the box to the installation surface 7. Connect all loads through the knock outs and glands (up to 5 loads can be connected) 8. Insert power supply, through the closest knock out. 9. Connect the power cable into the terminal block as per the wiring diagram (refer to 6. Wiring Diagram). 10. Once all connections are complete, replace and fasten the front cover using the included screws and screw caps
(refer to figures 6 & 7) 11. Once installation is complete, turn on the power to test.

5. TEST Y Set the Lux setting to position “3” and Switch the power on. Y For daytime testing, cover the sensor with a black cloth, box or any opaque test cover(refer to figure 8). Y Cover the detection window of the sensor, the ambient light picked up by the sensor will be dark and the
connected loads should switch on. Y Remove the cover after testing, they connected loads should automatically switch off.
6. WIRING DIAGRAM

7. PROBLEMS AND SOLUTIONS
The load does not work: Y Ensure the connection to the power source and load is correct. Y Check if the load is in working order. Y Check if the sensor settings corresponds with the ambient light conditions.
The sensitivity is poor: Y Check if there is any hindrance in front of the detector which may interfere with its ability to sense ambient
light. Y Check that the ambient temperature is below 40°C.
The sensor cannot shut off the load automatically: Y Check if there is an object casting a shadow or blocking ambient light. Y Confirm that the power supply is between 220V and 240V AC.

MAJOR TECH (PTY) LTD

South Africa

Australia

www.major-tech.com

www.majortech.com.au

sales@major-tech.com

info@majortech.com.au

Documents / Resources

MAJOR TECH DNS16 16A Day/Night Sensor with Timer [pdf] Instruction Manual
DNS16 16A Day Night Sensor with Timer, DNS16, 16A Day Night Sensor with Timer, Day Night Sensor with Timer, Sensor with Timer, Timer, Sensor

References