CE mark of conformity

M2M Services logo

MN01-LTE-M

Cellular Communicator with Dial Capture interface

Quick Installation Manual
Wiring the Communicator to the Alarm Panel

Red (+): ↔ 12-15V DC Power Supply
Black (-): ↔ Ground
Green (R): ↔  RING
Yellow (T): ↔  TIP

Alarm Panel
M2M MN01-LTE-M Cellular Communicator with Dial Capture interface 1 Antenna

Keyswitch Wiring*

Orange (O): ↔  to Keyswitch zone
White (W): ↔  to Armed status output

M2M MN01-LTE-M Cellular Communicator with Dial Capture interface 2Connector

Keybus Wiring*

Honeywell Vista and DSC Power Series Panels
Orange (O): ↔ to Yellow (Data Out)
White (W): ↔ to Green (Data In)

M2M MN01-LTE-M Cellular Communicator with Dial Capture interface 3Connector

Napco Panels
Orange (O): ↔ to TX (Green)
White (W): ↔ to RX (Yellow)

M2M MN01-LTE-M Cellular Communicator with Dial Capture interface 4 Connector

Interlogix NX Panels
Orange (O): ↔ to DATA
White (W): ↔ to DATA

M2M MN01-LTE-M Cellular Communicator with Dial Capture interface 5Connector

* Optional – wire only if interactive features will be used. Panel compatibility list for Keybus integration is available at support.m2mservices.com

Right tick WARNING: The wiring should be done only when the panel and the communicator are disconnected from the powerline!
Right tick WARNING: PRIMARY USE ONLY -­ NOT TO BE USED WITH LANDLINE!
Right tick Having a phone line connected will damage the unit!
Right tick Connect the antenna and place it outside of the alarm panel’s box.
Right tick Connect + and ­ of the communicator to a max of 12V – 15V DC power supply.
Right tick WARNING: THE USB PORT TO BE USED WITH M2M ADD-ON MODULES ONLY.

Find configuration guides for popular panels at support.m2mservices.com

LED Indicator
Right tick Slow flashing -­ trying to establish connection
Right tick Constantly On ­- connection established at good signal level
Right tick Constantly On, blinking every 5 sec. -­ connection established at low signal level
Right tick Fast flashing ­- transferring data

Configuring the alarm panel

Refer to the panel’s installation manual to configure the following options:
Right tick Enable the PSTN dialer of the panel.
Right tick Select DTMF mode (Tone Dialing).
Right tick Select Contact ID Full communication format or SIA.
Right tick Enter a telephone number for dialing (you can use any number, e.g. 9999999).
Right tick Enter a 4-digit account number in the panel.

Troubleshooting the DTMF communication
If you have issues receiving the events, try the following additional settings of the panel:
Right tick Disable “Telephone line monitoring”.
Right tick Disable “Wait for dial tone” option.
Right tick Use “A” instead of “0” in the account number.
Right tick If there is more than one partition, enter an account number for each partition.

For certain panels, you might need also to specify an account number for the main partition 0 (sometimes referred as system account number).

RControl App (end user) Credentials

Download the RControl mobile application on your Android or iOS device by scanning the QR codes.

M2M MN01-LTE-M Cellular Communicator with Dial Capture interface 6         M2M MN01-LTE-M Cellular Communicator with Dial Capture interface 7
Download on Google Playstore A       Download on Apple App store

Remote Arming/Disarming via Key switch (Optional)
Right tick Configure a zone as a momentary key switch (refer to the panel’s installation manual).
Right tick Configure a PGM output of the panel to activate (switch to ground), when the panel is armed, and to deactivate, when disarmed (refer to the panel’s installation manual).
Right tick Wire the device to the panel according to the Key switch wiring diagram (Page 1).
Right tick For panels that don’t have a status PGM, the status can be received through the OPEN/CLOSE reporting.

Guidelines for configuring the keyswitch and the output for popular panels are available at support.m2mservices.com

Initial pairing procedure for Remote Arming/Disarming via Keyswitch:
Right tick Enable Open/Close reporting (at least during the initial pairing procedure).
Right tick Log in to the RControl App and press Sync with Panel
Right tick Ask the end user to enter a Remote PIN code of his/her choice.
Right tick Disarm (or Arm) from the keypad within 2 minutes to complete the pairing.

Remote Arming/Disarming via Keybus for supported Honeywell, DSC, Napco and Interlogix Alarm Panels (Optional)
Panel compatibility list for Keybus integration is available at support.m2mservices.com Wire the device to the panel according to the Keybus wiring diagram.

For Honeywell panels ONLY: Program an alpha keypad address on the panel for each partition in use, starting from address 21 to 28 (21 for partition 1, 22 for partition 2, etc.).
The addresses should be reserved for the M2M communicator use only.

For Napco panels ONLY: Program a wizzard keypad address on the panel for each partition in use, starting from keypad 2 (21 for partition 1, 22 for partition 2, etc.).
The address should be reserved for the M2M communicator only.
Having a physical keypad on the first address is mandatory.

Right tick Log in to the RControl App, press Sync with Panel, and follow the instructions in the App.

NOTE: If panel programming is changed after the initial synchronization you need to:
Right tick Go to RControl App Settings >> Remote Arming/Disarming >> Press Sync and follow the instructions in the App

Unless prompted in the app, DO NOT operate the keypad during the sync process.

v.06-2023-15-03_10000