M2M - logo SIMPLICITY.
APPLIED.

MN02-LTE-M
Cellular Communicator with Dial Capture interface
Quick Installation Manual

RECOGNIZED COMPONENT
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon

Alarm Panel

M2M MN02 LTE M Cellular Communicator with Dial Capture Interface

Wiring the Communicator to the Alarm Panel
Red (+): ↔ 12-15V DC Power Supply
Black (-): ↔ Ground
Green (R): ↔ RING
Yellow (T): ↔ TIP

Keyswitch Wiring*
Orange (O): ↔ to Keyswitch zone
White (W): ↔ to Armed status output

Key bus Wiring*
Orange (O): ↔ to Yellow (Data Out)
White (W): ↔ to Green (Data In)

* Optional – wire only if interactive features will be used.
Panel compatibility list for Keybus integration is available at support.m2mservices.com

M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2  WARNING: The wiring should be done only when the panel and the communicator are disconnected from the powerline!
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Connect the RING and TIP of the alarm panel to the RING and TIP of the unit.
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 WARNING: PRIMARY USE ONLY – NOT TO BE USED WITH LANDLINE!
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Having a phone line connected will damage the unit!
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Connect the antenna and place it outside of the alarm panel’s box.
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Connect + and – of the communicator to a max of 12V – 15V DC power supply.

Find configuration guides for popular panels at support.m2mservices.com
LED Indicator

M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Slow flashing – trying to establish a connection
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Constantly On – connection established at the good signal level
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Constantly On, blinking every 5 sec. – connection established at the low signal level
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Fast flashing – transferring data

Configuring the alarm panel
Refer to the panel’s installation manual to configure the following options:
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Enable the PSTN dialer of the panel.
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Select DTMF mode (Tone Dialing).
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Select Contact ID Full communication format or SIA.
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Enter a telephone number for dialing (you can use any number, e.g. 9999999).
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Enter a 4-digit account number in the panel.

Troubleshooting the DTMF communication

If you have issues receiving the events, try the following additional settings of the panel:

M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Disable “Telephone line monitoring”.
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Disable the “Wait for dial tone” option.
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Use “A” instead of “0” in the account number.
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 If there is more than one partition, enter an account number for each partition.

For certain panels, you might need also to specify an account number for the main partition 0 (sometimes referred as system number).

Device Registration in M2M Dealer Portal

Register your company at www.m2mdealers.com or use your existing account to log in.

Adding preferred monitoring station
Contact your monitoring station and request your M2M Dealer Code.

  • Specify your preferred monitoring station during your initial registration in the section “Additional Information” > “Preferred CMS” list. Provide your Dealer code in the corresponding field, OR
  • Add preferred monitoring station/s after the registration form Home page > tab “CMS List” > “Add New“

Adding new device and choosing cellular service billing method:
Go to Home page > “Devices” > “New Device”.
Use the device Serial Number and the Config Key provided within this manual.
Select monitoring station (optional) – can be done later from tab “Assign / Change CMS”.

Select preferred monthly cellular service billing method:

  • Invoiced by the CMS – Cellular service invoices issued by your preferred monitoring station.
  • Invoiced by M2M Services – Cellular service invoices issued by M2M Services.

Control App (end-user) Credentials

Download the control mobile application on your

M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - Download

market://details?id=m2m.mobile

Android or iOS device by scanning the QR codes.

M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - app

http://itunes.apple.com/app/id712098315


Remote Arming/Disarming via Keyswitch (Optional)

M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Configure a zone as a momentary key switch (refer to the panel’s installation manual).
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Configure a PGM output of the panel to activate (switch to ground), when the panel is armed, and to deactivate when disarmed (refer to the panel’s installation manual).
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Wire the device to the panel according to the Keyswitch wiring diagram (Page 1).
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 For panels that don’t have a status PGM, the status can be received through the OPEN/CLOSE reporting.

Guidelines for configuring the key switch and the output for popular panels are available at support.m2mservices.com

Initial pairing procedure for Remote Arming/Disarming via Keyswitch:

M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Enable Open/Close reporting (at least during the initial pairing procedure).
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Log in to the control App and press Sync with Panel
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Ask the end-user to enter a Remote PIN code of his/her choice.
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Disarm (or Arm) from the keypad within 2 minutes to complete the pairing.

Remote Control via Keybus for supported Honeywell and DSC Alarm Panels (Optional)

Panel compatibility list for Keybus integration is available at support.m2mservices.com
Wire the device to the panel according to the Keybus wiring diagram (Page 1).

For Honeywell panels ONLY: Program an alpha keypad address on the panel for each partition in use, starting from address 21 to 28 (21 for partition 1, 22 for partition 2, etc.).

The addresses should be reserved for M2M communicator use only.

M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Power OFF and power ON the communicator, wait for ~20 sec. and enter and exit programming mode on the panel to initiate synchronization with the panel.

DO NOT operate the keypad during the sync process.

OR
M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2 Log in to the control App, press Sync with Panel, and follow the instructions in the App.

NOTE: If panel programming is changed after the initial synchronization you need to:

M2M MN02 LTE M Cellular Communicator with Dial Capture Interface - icon 2  Go to control App Settings >> Remote Arming/Disarming >> Press Sync and follow the instructions in the App
DO NOT operate the keypad during the sync process.

Release from Monitoring Station:
You can release a device from the monitoring station from tab “Devices” > “Release from CMS”.

If your monthly cellular service invoices are issued by your monitoring station, releasing the device will deactivate the corresponding cellular service.

The service can be reactivated by the monitoring station if the device is assigned for monitoring again (reactivation fees may apply).

IMPORTANT NOTE:
If you power a device before you register it, and without choosing a preferred cellular service billing method, the device will be deactivated.

Config Key:

v.03-2020-08-12

Documents / Resources

M2M MN02-LTE-M Cellular Communicator with Dial Capture Interface [pdf] Instruction Manual
MN02-LTE-M, Cellular Communicator with Dial Capture Interface

References