Installation Information

Under Counter (UC-24) Series

INSTALLATION CONSIDERATIONS

This section covers common installation issues that may be encountered by a Service Technician. Improper installation, while not a valid service issue, can lead to service calls. Installation-related complaints may include, but are not limited to: unit leveling, unit movement, door misalignment, door not sealing, internal frost or condensation, and exterior condensation, or warm compartment temperatures.

NOTE: For additional installation information, refer to the complete Installation Manual or contact the Sub-Zero Service Department.

Site Preparation

Ensure that the finished rough opening where the Undercounter unit will be installed is properly prepared. Refer to Figure 2-1 for rough opening dimensions, door swing clearance, and the location of electrical and plumbing connections (Model UC-24C).

NOTE: For proper operation, the door must open a minimum of 90°. Use a minimum 2" (51 mm) filler in corner installations to ensure a 90° door opening. Allow sufficient clearance in front of the unit for full door swing.

NOTE: The floor under the unit must be level with the surrounding finished floor.

NOTE: Dimensions in parentheses are in millimeters unless otherwise specified.

Figure 2-1 illustrates the rough opening and door swing. The diagram shows top, front, and side views with dimensions for rough opening width, depth, and height. It also indicates the location for water lines (Model UC-24C only) and anti-tip brackets. Door swing clearances are detailed, showing minimum and maximum angles and required door clearance space.

Anti-Tip Bracket Installation

WARNING: THE UNIT COULD TIP FORWARD UNDER CERTAIN LOAD CONDITIONS. FAILURE TO INSTALL ANTI-TIP COMPONENTS AND LEVEL THE UNIT ACCORDING TO THE INSTALLATION MANUAL COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

To install the Anti-Tip Bracket (See Figure 2-2):

  1. Locate and mark two wall studs at the back of the unit installation location.
  2. Identify and mark the proper height to clear the unit top. The space between the unit top and the bottom of the bracket must not exceed 1/4" (6.1 mm).
  3. Secure the bracket to the wall studs identified in step 1, ensuring screws extend 7/8" (22.2 mm) into each wall stud. The bracket must extend a minimum of 3" (76.2 mm) over the unit.
  4. Refer to the Installation Guide provided with the unit for any additional information.

Figure 2-2 shows anti-tip components, illustrating the bracket attached to wall studs above the unit.

Unit Leveling

NOTE: These models must be leveled before installation into the rough-in opening. If the unit is already installed and anchored through the countertop bracket (See Figure 2-3), extract the anchor screws and pull the unit from the rough-in opening. After leveling the unit as described below and reinstalling it into the rough-in opening, reinstall the anchor screws through the countertop bracket.

To Level:

  1. Place the appliance in front of the rough-in opening.
  2. Turn each leveling leg clockwise to raise the unit, and counterclockwise to lower the unit (See Figure 2-4).

Figure 2-3 shows a countertop bracket used for anchoring the unit.

Figure 2-4 illustrates the leveling legs, indicating that turning them clockwise raises the unit and counterclockwise lowers it.

Models: UC-24, UC24C, UC-24 24 Inch Undercounter Beverage Center, UC-24, 24 Inch Undercounter Beverage Center, Undercounter Beverage Center, Beverage Center

PDF preview unavailable. Download the PDF instead.

Service Manual - UC Series-5-6 iTextSharp™ 5.5.5 ©2000-2014 iText Group NV (AGPL-version) (AGPL-version); modified using iTextSharp™ 5.5.5 ©2000-2014 iText Group NV (AGPL-version)

Related Documents

Preview Sub-Zero Under Counter Series Installation Information
Installation guide for Sub-Zero Under Counter Series appliances, covering site preparation, electrical, plumbing, leveling, door adjustment, and custom panel installation.
Preview Sub-Zero Under Counter (UC-24) Series Technical Service Manual
Comprehensive technical service manual for Sub-Zero Under Counter (UC-24) Series appliances, covering installation, operation, features, troubleshooting, wiring diagrams, and repair procedures. Includes important safety information and warranty details.
Preview Sub-Zero Under Counter Series Airflow and Fan Blade Spacing Diagrams
Detailed diagrams illustrating airflow and fan bracket to fan blade hub spacing for Sub-Zero Under Counter Series models UC-24B, UC-24R, UC-24RO, and UC-24C. Includes critical spacing measurements and notes on service availability.
Preview Sub-Zero UC-24C Under Counter Refrigerator Wiring Diagram
Detailed wiring diagram for Sub-Zero UC-24C under counter refrigerator, including component identification, terminal summaries, and high/low voltage schematics. This document is intended for qualified service personnel.
Preview Sub-Zero UC-24R Parts List and Exploded Views
Comprehensive parts lists and exploded views for the Sub-Zero UC-24R under-counter refrigerator, detailing components for door, cosmetic, mechanical, and sealed system views.
Preview Sub-Zero Built-In (BI) Series Installation Information
Comprehensive installation guide for Sub-Zero Built-In (BI) Series refrigerators and freezers, covering site preparation, tools, materials, electrical and plumbing requirements, anti-tip bracket installation, leveling, door adjustments, panel removal, and anchoring.
Preview Sub-Zero UC-15I Undercounter Ice Machine Installation Guide
Comprehensive installation guide for the Sub-Zero UC-15I Undercounter Ice Machine, covering pre-installation considerations, electrical and plumbing requirements, and detailed installation procedures.
Preview Sub-Zero Built-In (BI) Series Installation Information
Installation considerations and specifications for Sub-Zero Built-In (BI) Series refrigerators and freezers, including rough opening dimensions, anti-tip bracket installation, electrical and plumbing requirements, and door adjustments.