OUPES Mega 3 Portable Power Station User Manual

NO POWER OOPS WITH OUPES

Disclaimer

Before using this product, please read this user manual carefully to ensure that you fully understand the product and can use it correctly. After reading this user manual, please keep it in a safe place for future reference. Improper use of this product may cause serious injury to yourself or others, or result in product damage and property loss. By using this product, you are deemed to have understood, recognized and accepted all the terms and contents of this document. The Company shall not be responsible for any damages caused by the user's failure to use this product in accordance with this user manual.

In accordance with laws and regulations, the company reserves the right of final interpretation of this document and all documents related to this product. This document is subject to change, update, revision or termination without notice.

Please visit our website for the latest product information.

  • The company shall not be held responsible for any damage caused by force majeure (e.g., fire, typhoon, flood, earthquake) or use under other abnormal circumstances by the customer.
  • The company bears no responsibility for loss caused by the use of non-standard connectors.
  • The company shall not be liable for any damage caused by non-compliance with the standard operation.
  • Please do not disassemble the product. Otherwise, the warranty will be voided.

Safety Instruction

Preparation Before Use

  1. 1.1 Read the User Manual
    Carefully review the user manual provided with the device to understand the power station's interface functions, rated power, supported device types, and usage methods. Pay special attention to the rated power and output voltage of each interface to ensure compatibility with connected devices.
  2. 1.2 Device Inspection
    Before use, inspect the power station and accessories to ensure they are intact, with no exposed wires or damaged interfaces. Confirm that all interfaces are dry and clean.

Device Compatibility and Precautions

  1. 2.1 Matching Power Specifications
    Verify that your device's rated power matches the power station's output. Examples include:
    • USB-C Interface: Suitable for small portable devices like smartphones and tablets (e.g., iPad).
    • Car Charger Interface: Avoid connecting sensitive devices like radios.
    • AC Socket: Designed for high-power devices like TVs or sound systems, but the power must be within the station's rated output.
  2. 2.2 Avoid Simultaneous Connection of High-Power and Sensitive Devices
    Do not connect high-power devices (e.g., refrigerators, induction cookers) and sensitive equipment (e.g., TVs) at the same time to prevent voltage fluctuations that could damage the devices. Do not use the power station to power medical equipment and precision instruments.
  3. 2.3 Special Note: List of Sensitive Devices
    Devices sensitive to voltage fluctuations include:
    • High-end TVs (OLED, 4K)
    • High-end sound systems
    • Tablets like iPads
    • Cameras and drones
    For these devices, use them individually and ensure proper interface matching.

Common Mistakes and How to Avoid Them

  1. 3.1 Using the Wrong Interface, Causing Device Damage
    Error Example: Using the car charger port for powering voltage-sensitive devices (e.g., radios).
    Precautionary Measures:
    • Check the device's power requirements (wattage, voltage).
    • Connect to the correct interface.
  2. 3.2 Damage Due to Instant Voltage Fluctuations
    Error Example: Keeping sensitive devices connected while turning the power station on or off.
    Precautionary Measures: Disconnect devices before powering the station on or off.
  3. 3.3 Overloading the Power Station
    Error Example: Powering multiple high-power devices simultaneously, exceeding the station's power limit.
    Solution: Check the station's rated power and plan device usage accordingly.

Usage Scenarios and Precautions

  1. 4.1 Charging via the car charger
    • Do not charge devices via the car charger interface when the vehicle is starting or stopping to avoid voltage spikes.
    • Ensure the device's power aligns with the station's output specifications when using the car charger interface.
  2. 4.2 Indoor Use
    For TVs, sound systems, and other devices in EPS mode, ensure the input source is grid power or a pure sine wave generator.
  3. 4.3 Outdoor Use
    • Keep the power station away from water, dust, and extreme temperatures.
    • Regularly clean interfaces and power cables after outdoor use.

APP

You can connect this product via APP to view information, control the device and personalize settings.

Scan the QR code to download our Smart Control APP.

Available On App Store

Available On Google Play

What's in the Box

  • Power Station*1
  • AC Charging Cable*1
  • Anderson to Anderson Cable*1
  • Cigarette Lighter to Anderson Cable*1
  • 7909 to Anderson Cable*1
  • MC4 to Anderson Cable*1
  • User Manual*1
  • Warranty Card*1
  • Brand card*1

Product Description

Specifications

CategoryDetails
AC Output100V~120V 50Hz/60Hz Max 3600W (Surge: 7000W) Bypass Mode: 2200W
DC 12V & Cigarette Lighter Output12V10A 120W Total
USB-A Output5V3A; 9V2A; 12V1.5A [18W Max]
USB-C Output5V3A; 9V3A; 12V3A; 15V3A; 20V5A [100W Max]
Anderson Output12V30A
AC Input100V~120V 60Hz 16A Max 1800W Max
Solar Input12V~148V MPPT: 18V~140V 15A Max 2100W Max
Cigarette Lighter Input12V~15V 8A Max
General Info
Battery Capacity3072Wh (51.2V/60Ah)
Battery TypeLiFePO4
Working Temperature32°F~104°F (0°C~40°C)
Storage Temperature-4°F~140°F (-20°C~60°C)
Dimension25.5*11.9*17.2in (641.5*304.5*437.5mm)
Net Weight83.33lb (37.8kg)

Overview

A diagram shows the front and back of the OUPES Mega 3 power station with various ports and buttons labeled:

  • Front Panel: USB-C Output Port, Anderson Output Port, USB-A Output Port, LCD Screen, Main Power Button, IOT Button, AC Output Socket, AC Output Power Button, DC Output Power Button, DC 5521 Output Port, Cigarette Lighter Output Port.
  • Back Panel: AC Input Port, Solar/Car Input Port, Circuit Breaker, Extra Battery Port, Handle.

LCD Screen

The LCD screen displays various information:

  • Remaining discharge time display
  • Error Warning
  • Battery Capacity Percentage
  • Battery Capacity Circle
  • WiFi & Bluetooth indicator
  • Input Power Display
  • Output Power Display
  • AC Output Indicator
  • USB-A Indicator
  • USB-C Indicator
  • High temperature Indicator
  • Cooling Fan indicator
  • Low temperature Indicator
  • Cigarette Lighter Indicator
  • DC 5521 Indicator
  • Icons indicating output modes: Car, DC.

Instructions for Use

Circuit Breaker Protection

a) Flip up AC IN breaker and AC OUT breaker before using the product.

b) When AC input or AC output exceeds 40A, AC IN breaker or AC OUT breaker will flip down automatically. Please disconnect all the connections for safety reason, and ensure that the current is lower than 40A. Then flip up the AC IN or AC OUT breaker to resume using.

Power ON/OFF

Main Power:

  1. Press and hold the main power button for 3 seconds to turn the main power on or off.
  2. When the main power is on, short press the main power button to turn the screen on or off.
  3. The product will shut down after 5 minutes without operation.

AC/DC Output Power:

  1. When the main power is on, press AC/DC output power button to turn on, press them again to turn off.
  2. The product will shut down after 12 hours without any load connected, which can be adjusted on the APP.

Recharge Methods

AC Charging

Use AC charging cable to connect AC wall outlet and the power station.

Solar Charging

  1. Use MC4 to Anderson charging cable to connect solar panels and the power station.
  2. Connect 6*240W solar panels at most in series to get maximum power.
  3. Make sure the solar panels meet the following requirements: OCV:148V; Current: 15A; Max Power: 2100W

Cigarette Lighter Charging

  1. The cigarette lighter port supports 12V~15V, 8A car charging input.
  2. Please ensure that the car is started before connecting the power station in case that the car battery drains.

Extra Battery Charging

  1. Turn off the power station and the extra battery before connecting or disconnecting them.
  2. Use battery expansion cable to connect the extra battery and the power station.

EPS (Emergency Power Supply) Function

  1. EPS function is enabled by default with a 20ms switching when grid power is cut off.
  2. Flip up AC IN and AC OUT breakers.
  3. Charge the power station from power grid and connect the device to AC output port as shown in the picture, then press AC output power button on.
  4. Please do not connect the power station to equipment requiring 0ms uninterrupted power supply.
  5. The total input and output power should lower than 2200W. Otherwise, the power station will shut down in 1 minute.

Error Code & Trouble Shooting

Error CodeStatusCauseSolution
E000

! + ⚡️ 60 Hz 12V 888V Output flashing, no output

Short circuit of AC output.Press the AC output power button to restore.
E001

! + ⚡️ 60 Hz 12V 888V Output flashing, no output

Overload of AC output.Press the AC output power button to restore.
E002

! + ⚡️ 60 Hz 12V 888V Output flashing, no output

Battery voltage of inverter input is low.Charge the device in time and restart the corresponding function button to restore.
E003

! + ⚡️ 60 Hz 12V 888V Output flashing, no output

Over voltage and under voltage of AC output.Press the AC output power button to restore.
E004

! + ⚡️ 60 Hz AAA 888V Output flashing, no input

Abnormal AC input frequency.Automatically restores after frequency returning to normal.
E005

! + ⚡️ Output flashing, no output

High and low bus voltage.Press the AC output power button to restore.
E006

! + ⚡️ 60 Hz 12V 888V Output flashing, no output

Over temperature of Inverter.Turn off output power and rest the device to restore.
E008

! + ⚡️ Output Watts flashing, no output

Overload and short circuit of 12V30A output port.Press the DC output power button to restore.
E009

! + ⚡️ Output Watts flashing

Overload or short circuit of 24V auxiliary power.Reduce the loads on DC output port.
E010

! + ⚡️ O Car DC flashing, no output

Overload or short circuit of the cigarette lighter output port.Press the DC output power button to restore.
E011

! + ⚡️ -USB-A Output flashing, no output

Overload or short circuit of the USB-A port.Press the DC output power button to restore.
E012

! + ⚡️ +USB-C Output flashing, no output

Overload of the USB-C port.Press the DC output button to restore.
E020

! + ⚡️ Output Watts flashing

BMS communication failure.Contact after sales service team for further support.
E021

! + ⚡️ Output Watts flashing

Over voltage of single battery cellStop charging and discharge until the battery voltage returns to normal.
E022

! + ⚡️ Output Watts flashing, no ouput

Low Voltage of single battery cell.Charge the device until the voltage returns to normal.
E023

! + ⚡️ Output flashing

Battery total voltage too highStop charging and start discharging until the battery voltage returns to normal.
E024

! + ⚡️ Output Watts flashing

Battery total voltage too lowCharge the device until the voltage returns to normal.
E025

! + ⚡️ ++ flashing, no output

High temperature of battery.The device will automatically return to normal when the temperature returns to normal.
E026

! + ⚡️ Output flashing, no output

Low temperature of battery.The device will automatically return to normal when the temperature returns to normal.
E027

! + ⚡️ 60 Hz 12V 888V Output flashing, no AC output. DC output is normal.

System overload, AC output is over 3600VA or the total AC and DC output is over 3600W.Reduce AC loads and press the AC power button to restore.
E028

! + ⚡️ Output flashing, no input

Charge over temperature.Charge the device after the temperature returning to normal.
E029

! + ⚡️ Output flashing, no intput

Over temperature of MOSFET.The device will automatically return to normal when the temperature returns to normal.
E030

! + ⚡️ Output flashing

Connect the wrong expansion battery.Connect correct extra battery to restore.

FAQ

Scan QC code for FAQ.

Certification and Compliance

FCC Warning

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Contact Information

Customer Service Hours (EST):

  • Call Us: +1 (209) 400-9909 (9:00 AM – 5:00 PM, Mon. - Fri.)
  • Email Us: 9:00 PM – 5:00 AM, Mon. - Fri.

Customer Support: support@oupes.com

Amazon Support: aftersale@oupes.com

Website: https://oupes.com

Models: SG-Mega3 240 3, Mega 3 3600W Solar Generator Plus, Mega 3, 3600W Solar Generator Plus, Solar Generator Plus, Generator Plus, Plus

File Info : application/pdf, 20 Pages, 6.15MB

PDF preview unavailable. Download the PDF instead.

48f5aecf-5632-4751-835e-40f522ffeaee

References

Adobe PDF library 17.00 Adobe Illustrator 28.4 (Windows)

Related Documents

Preview OUPES Mega 3 Portable Power Station User Manual | 3600W 3072Wh
Comprehensive user manual for the OUPES Mega 3 Home Backup & Portable Power Station. Learn how to safely operate, charge, and maintain your 3600W, 3072Wh power station for reliable backup power.
Preview OUPES Titan 3 3600W Smart Generator User Manual
Comprehensive user manual for the OUPES Titan 3 3600W Smart Generator, covering specifications, operation, charging methods, troubleshooting, and maintenance. Learn how to use your generator safely and effectively.
Preview OUPES Mega 2 2500W Portable Power Station User Manual
Comprehensive user manual for the OUPES Mega 2 2500W portable power station, covering setup, operation, charging methods, troubleshooting, and maintenance.
Preview OUPES 2000W Outdoor Power Station MEGA 1 User Manual
Comprehensive user manual for the OUPES 2000W Outdoor Power Station MEGA 1, detailing specifications, operation, charging methods, troubleshooting, and maintenance for optimal use.
Preview OUPES Mega 5 4000W Portable Power Station User Manual
User manual for the OUPES Mega 5 portable power station, detailing its 4000W output, 5040Wh LiFePO4 battery, various charging methods, functions, troubleshooting, and maintenance. Optimized for accessibility and SEO.
Preview OUPES 2000W LiFePO4 Power Station & 240W Solar Panel Kit - Portable Generator
Explore the OUPES 2000W portable power station, featuring a 4500W peak output and a long-lasting LiFePO4 battery. This generator kit includes a 240W solar panel for renewable charging, offering reliable power for camping, emergencies, and off-grid use. Key specifications and features detailed.
Preview OUPES Exodus 2400 Portable Power Station User Manual
Comprehensive user manual for the OUPES Exodus 2400 Portable Power Station, detailing specifications, functions, charging methods, troubleshooting, and maintenance.
Preview OUPES MEGA 5 4000W Portable Power Station User Manual
Comprehensive user manual for the OUPES MEGA 5 4000W Portable Power Station, covering setup, operation, charging methods, troubleshooting, and maintenance.