UTS1000B/T Series Spectrum Analyzer
Datasheet V1.3 | June 2025
Product Features
- Frequency measurement range: 9 kHz to 1.5 GHz, 9 kHz to 3.2 GHz
- Display average noise level (DANL) can be as low as -161 dBm (Typical value)
- Phase noise < -98 dBc/Hz (Offset 10 kHz, typical value)
- Full amplitude Precision < 0.7 dB
- Up to 10,001 scanning points
- Minimum resolution bandwidth (RBW) 1 Hz
- Advanced function one key measurement (Option)
- EMI Pre-compliance analysis function (Option)
- Supports analog demodulation analysis (Option)
- Supports tracking generator output function (UTS1000T Only)
- 10.1-inch 1280 × 800 HD capacitive touch screen
- Provides USB/LAN interface, supports SCPI protocol
Multi-touch HD Screen for Quick Operation
The 10.1-inch multi-touch HD capacitive screen features quick menu settings and supports multiple gesture operations such as dragging, expanding, and zooming on the trace. This provides a convenient human-computer interaction experience, minimizing cumbersome and difficult operations.
Example Display: A spectrum analysis screen showing signal amplitude over frequency, with controls for center frequency, span, and resolution bandwidth.
Excellent Sensitivity to Test Weaker Signals
The UTS1000B/T series offers excellent sensitivity, with a DANL as low as -161 dBm, making it ideal for testing weak signals that are easily affected by the analyzer's noise floor.
Example Display: A spectrum analysis screen showing a very low amplitude signal, demonstrating the analyzer's sensitivity with a DANL of -161 dBm.
Removable Dust Mesh
The instrument features a detachable dust filter that can be removed from the air inlet to prevent dust accumulation. This ensures the reliability of the machine and prevents potential issues like short-circuit, burn, or fire caused by dust.
Visual Description: The rear panel of the spectrum analyzer is shown, highlighting the air inlet with a dust mesh.
Scan 10,001 points
The UTS1000B/T series supports up to 10,001 sweep points, enabling higher frequency resolution and making it easier to capture difficult-to-detect signals.
Example Displays: Two spectrum analysis screens are shown, illustrating the difference in detail when using a higher number of sweep points.
Excellent Selectivity
The spectrum analyzer demonstrates a strong capability to resolve signals with adjacent unequal amplitudes.
Example Display: A spectrum analysis screen showing two closely spaced signals with different amplitudes, highlighting the analyzer's selectivity.
EMI Pre-compliance (Option)
With optional components and near-field probes, the UTS1000B/T series assists in locating and resolving EMI defects early in the development cycle.
Example Display: An EMI scan showing signal levels against frequency, with markers indicating compliance limits and measured values.
Advanced Measurement (Option)
The advanced measurement mode supports various transmitter test specifications, including Channel Power, T-power, Occupied BW, TOI, ACP, Spectrum Monitor, CNR, and Harmonics.
Example Display: A spectrum analyzer screen configured for advanced measurements, showing parameters like Channel Power and Occupied Bandwidth.
Analog Demodulation Analysis (Option)
The analyzer provides AM and FM analog signal demodulation analysis capabilities.
Example Displays: Screens showing analog demodulation analysis, including demodulated waveforms and modulation parameters for AM and FM signals.
Definitions and Conditions
Specifications: Describe performance parameters covered by the product warranty, generally applicable within a temperature range of 20°C to 30°C unless otherwise noted.
Typical: Refers to product performance information not covered by the product warranty. 80% of units exhibit 95% confidence over the 20°C to 30°C range when performance is out of specification. Typical performance does not include measurement uncertainty.
Nominal Value: Represents expected performance or product performance useful in applications but not covered by the product warranty.
Operating Conditions: The analyzer meets specifications when within its calibration cycle and warmed up for at least 30 minutes. If stored outside the operating temperature range, it requires at least two hours of acclimatization within the allowable operating temperature range before use.
Product Function and Model Comparison Table
Feature | UTS1015B | UTS1032B | UTS1015T | UTS1032T |
---|---|---|---|---|
Spectrum analysis | ● | ● | ● | ● |
EMI | ○ | ○ | ○ | ○ |
Analog demodulation | ○ | ○ | ○ | ○ |
Advanced measurement | ○ | ○ | ○ | ○ |
Tracking generator | × | × | ● | ● |
Note: ● Standard, ○ Option, × Not supported
Frequency and Time Specifications
Frequency
Model | UTS1015B/T | UTS1032B/T |
---|---|---|
Frequency range | 9 kHz to 1.5 GHz | 9 kHz to 3.2 GHz |
Resolution bandwidth | 1 Hz |
10 MHz internal frequency reference
Frequency reference | 10.000000 MHz | |
Precision | ± [(time since last adjustment x aging rate) + temperature stability +calibration Precision] | |
Achievable initial calibration Precision | < 1 ppm | |
Temperature stability | < 1 ppm |
Frequency readout Precision (start, stop, center, marker)
Marker resolution | Span / (Sweep point-1) | |
Marker frequency uncertainty | ± (Marker frequency x Frequency reference Precision + 1 %x Span + 10 % x RBW+ Marker resolution) | |
Marker Mode | Normal, Delta∆, Fixed | |
Marker function | Marker Noise, Band Power, Band Density, N dB, Counter | |
Counter resolution | 1 Hz | |
Uncertainty of frequency counter | ± [Marker frequency x Frequency reference precision + Counter resolution] |
Frequency span (FFT and swept mode)
Sweep range | 0 Hz, 100 Hz to 1.5 GHz | 0 Hz, 100 Hz to 3.2 GHz |
Sweep Precision | Swept: ±[0.25%*Span+Span / (Points-1)] | FFT: ±[0.10%*Span+Span / (Points-1)] |
Sweep time and triggering
Sweep time | 1 ms to 4,000 s (span ≠ 0) 1 μs to 4,000 s (span = 0) |
|
Sweep Type Rule | Precision, Normal | |
Sweep Mode | Swept (1 kHz to 1 MHz), FFT (1 Hz to 30 kHz) | |
Sweep Rules | Single, Continuous | |
Trigger Type | Free Run, External, Video | |
External trigger input | TTL, Rising/Falling |
Resolution bandwidth (RBW)
Range (-3dB bandwidth) | 1 Hz to 1 MHz, 1-3-10 steps | |
Selectivity (-60 dB/-3 dB) | < 4.8: 1 (Nominal) | |
Bandwidth Precision (-3dB) | < 5 % (Nominal) |
Video bandwidth (VBW)
Range | 1 Hz to 1 MHz,1-3-10 steps | |
Uncertainty of video bandwidth | < 5% |
Amplitude Precision and Range Specifications
Amplitude range
range | 10 MHz to maximum frequency: (DANL) to +30 dBm | |
Reference level | -100 dBm to+30 dBm, steps 1 dB | |
Preamp | 20 dB, Nominal, 9 kHz to 1.5 GHz (3.2 GHz) | |
Input attenuator range | 0 to 51 dB, 1 dB Step |
Maximum safe input level
DC volts | 50 V DC | max |
Maximum continuous wave RF power | < +33 dBm | 3 minutes, Input attenuation > 20 dB |
Display range
Log scale | 1 dB to 200 dB | |
Linear scale | 0 to Reference level | |
Scale units | dBm, dBmV, dBμV, V, W | |
Sweep (trace) point range | 10,001 | |
Number of traces | 4 | |
Detector | Sample, Peak, Negative, Normal, Average | |
Trace Type | Clear/Write, Average, Max Hold, Min Hold |
Frequency response
20°C to 30°C, 30% to 70% relative humidity, Input attenuation 20 dB, be relative to 50 MHz. | ||
Preamp Off | 9 kHz to 3.2 GHz | ±0.6 dB; ± 0.3 dB, Typical |
Preamp On | 100 kHz to 3.2 GHz | ±1.0 dB; ± 0.8 dB, Typical |
Error and precision
Resolution bandwidth switching uncertainty | Relative to 10 kHz RBW logarithmic resolution ± 0.2 dB, linear resolution ± 0.01, Nominal | |
Input attenuation switching uncertainty | 20 to 30 °C, fc=50 MHz, Preamp Off, Relative to 20 dB attenuation, Input attenuation 1 to 51 dB ± 0.5 dB |
|
Absolute amplitude Precision | 20 to 30 °C, fc=50 MHz, RBW=1 kHz, VBW=1 kHz, Peak detectors, Input attenuation20 dB ± 0.4 dB, Input signal level -20 dBm, Preamp Off ± 0.5 dB, Input signal level -40 dBm, Preamp On |
|
Total absolute amplitude Precision | 20 to 30 °C, fc > 100 kHz, Input signal level -50 dBm to 0 dBm, RBW = 1 kHz, VBW = 1 kHz, Peak detectors, Input attenuation 20 dB, Preamp Off, 95% confidence ± (0.4 dB+ Frequency response) |
|
Input voltage standing wave ratio (VSWR) | 1 MHz to 1.5 GHz ≤ 1.8 (Nominal) |
1 MHz to 3.2 GHz ≤ .8 (Nominal) |
Dynamic Range Specifications
1 dB gain compression
20 to 30 °C, fc ≥ 50 MHz, Input attenuation 0 dB, Preamp off
> -5 dBm, Nominal
Displayed average noise level (DANL)
20 to 30 °C, 0dB RF attenuation, RBW=1 Hz, VBW=1 Hz, sample detector, average > 50
Frequency | UTS1015B/T | UTS1032B/T |
---|---|---|
9 kHz to 500 kHz | -130 dBm (Nominal) | -105 dBm (Nominal) |
500 kHz to 1 MHz | -143 dBm, -145 dBm (Typical) | -115 dBm, -120 dBm (Typical) |
1 MHz to 10 MHz | -142 dBm, -144 dBm (Typical) | -127 dBm, -130 dBm (Typical) |
10 MHz to 200 MHz | -142 dBm, -143 dBm (Typical) | -142 dBm, -145 dBm (Typical) |
200 MHz to 1.5 GHz | -140 dBm, -142 dBm (Typical) | -143 dBm, -146 dBm (Typical) |
1.5 GHz to 3.2 GHz | --- | -140dBm, -143dBm (Typical) |
9 kHz to 500 kHz | -145 dBm (Nominal) | -125 dBm (Nominal) |
500 kHz to 1 MHz | -155 dBm, -157 dBm (Typical) | -130 dBm, -135 dBm (Typical) |
1 MHz to 10 MHz | -155 dBm, -158 dBm (Typical) | -145 dBm, -147 dBm (Typical) |
10 MHz to 200 MHz | -158 dBm, -160 dBm (Typical) | -158 dBm, -160 dBm (Typical) |
200 MHz to 1.5 GHz | -159 dBm, -161 dBm (Typical) | -161 dBm, -164 dBm (Typical) |
1.5 GHz to 3.2 GHz | -159 dBm, -161 dBm (Typical) | -159 dBm, -161 dBm (Typical) |
Spurious responses
Second harmonic distortion (SHI): 20 to 30 °C, Preamp off, Signal input-30 dBm, 0dB RF attenuation, fc ≥ 50 MHz
-65 dBc/+35 dBm
Third-order intermodulation distortion (TOI): 20 to 30 °C, Preamp off, Signal input-20 dBm, 0 dB RF attenuation, fc ≥ 50 MHz
+10 dBm; +13 dBm Nominal
Input related spurious: 20 to 30 °C, Mixer level: -30 dBm
< -60 dBc
Residual responses: 20 to 30 °C, Input port 50 Ω, RF attenuation 0 dB
< -90 dBm
Phase noise
20 to 30 °C, fc = 1 GHz, RBW=1 kHz, VBW=10 Hz, Sampling detection, Log avg, avg> 50
Offset | UTS1015B/T | UTS1032B/T |
---|---|---|
10 kHz | -95 dBc/Hz, -98 dBc/Hz (Typical) | -95 dBc/Hz, -98 dBc/Hz (Typical) |
100 kHz | -96 dBc/Hz, -98 dBc/Hz (Typical) | -93 dBc/Hz, -98 dBc/Hz (Typical) |
1 MHz | -115 dBc/Hz, -120 dBc/Hz (Typical) |
-115 dBc/Hz, -120 dBc/Hz (Typical) |
Example Display: A phase noise plot showing noise levels at different frequency offsets from the carrier signal.
Tracking Generator Specifications (UTS1000T Only)
Frequency
100 kHz to 1.5 GHz | 10 MHz to 3.2 GHz | |
---|---|---|
Frequency range | 100 kHz to 1.5 GHz | 10 MHz to 3.2 GHz |
Counter resolution | 10 Hz |
Output power level
Range | -40 dBm to 0 dBm | |
Resolution | 0.5 dB | |
Flatness output | ± 3 dB |
Maximum safe reverse input level
Average total power | 30 dBm | |
AC coupling | ±50 VDC |
Analog Demodulation Analysis (Option)
Demodulation
2 MHz to 1.5 GHz | 2 MHz to 3.2 GHz | |
---|---|---|
Frequency range | 2 MHz to 1.5 GHz | 2 MHz to 3.2 GHz |
Carrier power Precision | ± 2 dB | |
Input power | -30 dB to +20 dBm | |
Carrier power display resolution | 0.01 dBm |
AM measurement
Modulation rate | 20 Hz to 100 kHz | Modulation rate <1 kHz |
Precision | 1 Hz (Nominal) | < 0.1%Modulation rate (Nominal) |
Depth | 5 to 95% | Modulation rate ≥1 kHz |
Precision | ± 4% (Nominal) |
FM measurement
Modulation rate | 20 Hz to 100 kHz | Modulation rate < 1 kHz |
Precision | 1 Hz (Nominal) | < 0.1% Modulation rate (Nominal) |
Frequency offset | 1 kHz to 400 kHz | Modulation rate ≥ 1 kHz |
Precision | ± 4% (Nominal) |
EMI (Option)
EMI Resolution bandwidth
Resolution bandwidth (-6dB) | 200 Hz, 9 kHz, 120 kHz, 1 MHz | |
Resolution bandwidth Precision | < 5%, (Nominal) |
EMI detector
EMI detector | Peak, Negative Peak, Quasi Peak, EMI Average, Average |
EMI Main function
Main function | EMI Standard: CISPR View: Scan table, Meter, Signal table Meter control Avg settings Limit: AS-NZS, BellCore, DEF-STAN, DO-160, EN, FCC, GB9254, MIL-461, VCCI and Custom Signal table settings Scan table settings Scan Sequence: Scan, Search, Scan-Search-Meas, Scan-Search, Search-Meas, Measure Sig Detector Output report |
Advanced measurement kit (Option)
Power Measurement
Channel power | Channel power, Power spectral density |
ACP (Adjacent Channel Power) | Main CH Power, Left channel power, Right channel power |
Occupied bandwidth | Occupied Bandwidth, Transmit Frequency Error |
Time domain power | Zero Span Integrated Power |
CNR (Carrier Noise Ratio) | C/N, Noise Power |
Non-Linear Measurement
TOI, Third-order intercept | Measure the third-order products from two tones |
Harmonic measurement | Max Harmonic number 10 |
Spectrum Monitor Measurement
Spectrogram |
Interface and display
Common interface
RF input | Type-N female, 50 Ω, nominal |
Front panel trace source output | Type-N female, 50 Ω, nominal |
10 MHz Ext Ref In | 10 MHz, > 0 dBm, BNC female, 50 Ω, nominal |
10 MHz out | 10 MHz, -5 dBm to +10 dBm, BNC female, 50 Ω, nominal |
External trigger input | TTL, BNC female |
HDMI display | HDMI 1.4 display interface |
USB-Host | USB-A |
USB-Device | USB-B |
LAN | LAN (VXI11), 10/100/1,000 Base, RJ-45 |
Headphone Jack | 3.5 mm (1/8 inch) miniature stereo audio jack |
Display screen
Display type | 10.1-inch capacitive multi-touch panel |
Display resolution | 1280×800, RGB Vertical pixel |
General Technical Specifications
Supply voltage | 100 to 240 VAC (Fluctuations ± 10%) | 100 to 120 VAC (Fluctuations ± 10%) |
Frequency | 50/60 Hz | 400 Hz |
Temperature range | operation: 0°C to +40°C Non-operating: -20°C to +60°C |
|
Cooling method | Fan forced cooling | |
Humidity range | Operation: Below + 35 °C ≤ 90% relative humidity; Non-operating: + 35 °C to +40 °C ≤ 60% relative humidity |
|
Altitude | Operation: Below 3,000 m; Non-operating: Below 15,000 m | |
Pollution degree | 2 | |
Operating environment | Indoor use |
Mechanical specifications
Dimensions | 378mm×218mm×120mm (Width x Height x Length) | |
Net weight | 4.55 kg | |
Calibration period | The recommended calibration period is one year |
Regulatory standards
EMC
Compliance with EMC directives (2014/30/EU), conform to or better than IEC 61326-1:2021/EN61326-1:2021, IEC 61326-2-1:2021/EN61326-2-1:2021 | ||
Conductive disturbance | CISPR 11/EN 55011 | CLASS B group 1, 150 kHz-30 MHz |
Radiation disturbance | CISPR 11/EN 55011 | CLASS B group 1, 30 MHz-1 GHz |
Electrostatic discharge (ESD) | IEC 61000-4-2/EN 61000-4-2 | ±4.0 kV (Contact), ±8.0 kV (air) |
Radio frequency electromagnetic field immunity | IEC 61000-4-3/EN 61000-4-3 | 3 V/m (80 MHz to 1 GHz) ; 1 V/m (1.4 GHz to 6 GHz) |
Electrical fast transient burst (EFT) | IEC 61000-4-4/EN 61000-4-4 | ±1 kV (AC input port) |
Surge | IEC 61000-4-5/EN 61000-4-5 | ±0.5 kV (Live line to zero line) ±1 kV (Fire/zero line to ground) |
Immunity to RF continuous conduction | IEC 61000-4-6/EN 61000-4-6 | 3V, 0.15-80 MHz |
Voltage dips and short interruptions | IEC 61000-4-11/EN 61000-4-11 | Voltage dip: 0% UT during 0.5 cycle; 0% UT during 1 cycle; 70% UT during 25/30 cycles Short Interruption: 0% UT during 250/300 cycles |
Safety regulations
EN 61010-1:2010+A1:2019 | |
EN IEC61010-2-030:2021+A11:2021 | |
UL 61010-1:2012 Ed.3+ R:19 Jul2019 | |
UL 61010-2-030:2018 Ed.2 | |
CSA C22.2#61010-1:2012 Ed.3+U1;U2;A1 | |
CSA C22.2#61010-2-030:2018 Ed.2 |
Order Information
Model
Description | Order No. |
---|---|
Spectrum analyzer, 9 kHz to 1.5 GHz | UTS1015B |
Spectrum analyzer, 9 kHz to 3.2 GHz | UTS1032B |
Spectrum analyzer, 9 kHz to 1.5 GHz, TG | UTS1015T |
Spectrum analyzer, 9 kHz to 3.2 GHz, TG | UTS1032T |
Standard accessories
Power cord ×1 | |
USB cable x1 | UT-D14 |
Recommended options & accessories
Options
Advanced measurement kit | UTS1000-AMK |
EMI measurement option | UTS1000-EMI |
Analog demodulation analysis option | UTS1000-AMA |
UT-CK01 accessories kit
SMAJ-NJ-0.7M DC-6G cable x1 | UT-W02-6GHz |
NJ-NJ-0.7M DC-6G cable x1 | UT-W01-6GHz |
Adapter SMA-N-KJ-T DC-6GHz x2 | UT-C01-6GHz |
Adapter N-BNC-JK DC-4GHz x2 | UT-C02-4GHz |
Antenna 2400 MHz-2500 MHz x2 | UTS-T01 |
Antenna 824-960 MHz/1710-1990 MHz x2 | UTS-T02 |
50Ω-SMA-SMB cable x1 | UT-W03 |
Adapter SMA-N-KJ-T DC-6 GHz x1 | UT-C01 |
UTS-EMI01 Near-field probes kit
Near field probe, frequency range 30 MHz-3 GHz, Detection range 10 cm x1 | NFP-3G-P1 |
Near field probe, frequency range 30 MHz-3 GHz, Detection range 3 cm x1 | NFP-3G-P2 |
Near field probe, frequency range 30 MHz-2 GHz, resolving power 5 mm x1 | NFP-2G-P3 |
Near field probe, frequency range 30 MHz-3 GHz, resolving power 2 mm x1 | NFP-3G-P4 |
Options ordering and installation
- Purchase options: Based on your requirements, purchase specified function options from Uni-t Sales Personnel and provide the instrument's serial number for installation.
- Receive certificate: You will receive a license certificate based on the provided address.
- Register and obtain license: Visit the Uni-t official website for license activation. Use the license key and instrument serial number from the certificate to obtain the option license code and license file.
- Install the option: Download the option license file to the root directory of a USB storage device and connect it to the instrument. Once recognized, the Option Install menu will be activated. Press this menu key to begin installation.
Limited Warranty and Liability
UNI-T guarantees the Instrument product is free from defects in material and workmanship for three years from the purchase date. This warranty does not cover damages caused by accident, negligence, misuse, modification, contamination, or improper handling. For warranty service, contact your seller directly. UNI-T is not responsible for any special, indirect, incidental, or subsequent damage or loss caused by using this device. The warranty period for probes and accessories is one year. Visit instrument.uni-trend.com for full warranty information.
Product Registration: Register your product to confirm ownership, receive product notifications, update alerts, exclusive offers, and the latest information.
UNI-T is a licensed trademark of UNI-TREND TECHNOLOGY (CHINA) CO., Ltd. UNI-T products are protected by patent laws. Licensed software products are the properties of UNI-Trend and its subsidiaries. This document may be updated without notice.
For more information on UNI-T Test & Measure Instrument products, applications, or service, contact UNI-T instrument support via www.uni-trend.com -> instruments.uni-trend.com.
Contact Information:
Headquarter
UNI-TREND TECHNOLOGY (CHINA) CO., Ltd.
Address: No.6, Industrial North 1st Road, Songshan Lake Park, Dongguan City, Guangdong Province, China
Tel: (86-769) 8572 3888
Europe
UNI-TREND TECHNOLOGY EU GmbH
Address: Steinerne Furt 62, 86167 Augsburg, Germany
Tel: +49 (0)821 8879980
North America
UNI-TREND TECHNOLOGY US INC.
Address: 2692 Gravel Drive, Building 5, Fort Worth, Texas 76118
Tel: +1-888-668-8648
Copyright © 2025 by UNI-Trend Technology (China) Co., Ltd. All rights reserved.