UNI-T UTS3000T+ Series Spectrum Analyzer

Datasheet

Product Features

Multi-touch HD Screen for Quick Operation

10.1-inch multi-touch HD capacitive screen with quick menu settings. Supports multiple gesture operations such as dragging, expanding, and zooming on the trace. Convenient human-computer interaction operation solves the problem of cumbersome and difficult operation to the greatest extent.

Excellent Sensitivity to Test Weaker Signals

The weak signal test is easily affected by the noise floor of the spectrum analyzer itself. UTS3000T+ series has a DANL as low as -161 dBm, providing excellent sensitivity to effectively test weak signals.

Removable Dust Mesh

With a detachable dust filter, after the instrument is used for a period of time, the user can remove the dust from the air inlet. To ensure the reliability of the whole machine, it can avoid short-circuit, burn or fire caused by dust.

Scan 10,001 points

UTS3000T+ series provides up to 10,001 sweep points, offering higher frequency resolution and making it easier to capture signals that are difficult to detect.

Excellent Selectivity

It has a stronger capability to resolve signals of adjacent unequal amplitudes.

EMI pre-compliance (Option)

UTS3000T+ series includes optional components that, when used with near-field probes, assist in locating and resolving EMI defects in advance, thereby shortening the development cycle.

Advanced measurement (Option)

The advanced measurement mode provides the test items required by the transmitter test specification: Channel Power, T-power, Occupied BW, TOI, ACP, Spectrum Monitor, CNR, and Harmonics.

Analog demodulation analysis (Option)

Provides AM, FM analog signal for demodulation analysis.

Definitions and Conditions

"Specifications" describes the performance of the parameters covered by the product warranty in detail, unless otherwise noted, these specifications apply to the temperature range of 20°C to 30°C.

"Typical" refers to other product performance information not covered by the product warranty. 80% of the units can exhibit 95% confidence over the temperature range of 20 °C to 30 °C when performance is out of specification. Typical performance does not include measurement uncertainty.

"Nominal Value" means expected performance, or describes product performance that is useful in product applications but not covered by the product warranty.

The analyzer can meet its specifications under the following conditions:

Product Function and Model Comparison Table

UTS3015T+ UTS3032T+
Spectrum analysis
EMI
Analog demodulation
Advanced measurement
Tracking generator
Reflection measurement

Note: ● Standard ○ Option ◍ Not supported

Frequency and Time Specifications

Frequency

UTS3015T+ UTS3032T+
Frequency range 9 kHz to 1.5 GHz 9 kHz to 3.2 GHz
Resolution bandwidth 1 Hz

10 MHz internal frequency reference

Frequency reference 10.000000 MHz
Precision ± [time since last adjustment x aging rate) + temperature stability +calibration Precision]
Achievable initial calibration Precision < 1 ppm
Temperature stability < 1 ppm
Aging rate ≤ ±1.0 ppm/ year

Frequency readout Precision (start, stop, center, marker)

Marker resolution Span / (Sweep point-1)
Marker frequency uncertainty ± (Marker frequency x Frequency reference Precision + 1 %x Span + 10 % x RBW+ Marker resolution)
Marker Mode Normal, Delta∆, Fixed
Marker function Marker Noise, Band Power, Band Density, N dB, Counter
Counter resolution 1 Hz
Uncertainty of frequency counter ± [Marker frequency x Frequency reference precision + Counter resolution]

Frequency span (FFT and swept mode)

Sweep range 0 Hz, 100 Hz to 1.5 GHz 0 Hz, 100 Hz to 3.2 GHz
Sweep Precision Swept ±[0.25%*Span+Span / (Points-1)] FFT ±[0.10%*Span+Span / (Points-1)]

Sweep time and triggering

Sweep time 1 ms to 4,000 s (span ≠ 0)
1 μs to 4,000 s (span = 0)
Sweep Type Rule Precision, Normal
Sweep Mode Swept (1 kHz to 1 MHz), FFT (1 Hz to 30 kHz)
Sweep Rules Single, Continuous
Trigger Type Free Run, External, Video
External trigger input TTL, Rising/Falling

Resolution bandwidth (RBW)

Range (-3dB bandwidth) 1 Hz to 1 MHz, 1-3-10 steps
Selectivity (-60 dB/-3 dB) < 4.8: 1 (Nominal) 60 dB: < 3 dB
Bandwidth Precision (-3dB) < 5 % (Nominal)
Video bandwidth (VBW) 1 Hz to 1 MHz,1-3-10 steps
Uncertainty of video bandwidth < 5%

Amplitude Precision and Range Specifications

Amplitude range 10 MHz to maximum frequency: (DANL) to +30 dBm
Reference level -100 dBm to+30 dBm, steps 1 dB
Preamp 20 dB, Nominal, 9 kHz to 1.5 GHz (3.2 GHz)
Input attenuator range 0 to 51 dB, 1 dB Step
Maximum safe input level
DC volts 50 V DC
Maximum continuous wave RF power < +33 dBm 3 minutes, Input attenuation > 20 dB
Display range
Log scale 1 dB to 200 dB
Linear scale 0 to Reference level
Scale units dBm, dBmV, dBμV, V, W
Sweep (trace) point range 10,001
Number of traces 4
Detector Sample, Peak, Negative, Normal, Average
Trace Type Clear/Write, Average, Max Hold, Min Hold
Frequency response 20°C to 30°C, 30% to 70% relative humidity, Input attenuation 20 dB, be relative to 50 MHz.
Preamp Off 9 kHz to 3.2 GHz ±0.6 dB; ± 0.3 dB, Typical
Preamp On 100 kHz to 3.2 GHz ±1.0 dB; ± 0.8 dB, Typical
Error and precision
Resolution bandwidth switching uncertainty Relative to 10 kHz RBW logarithmic resolution ± 0.2 dB, linear resolution ± 0.01, Nominal
Input attenuation switching uncertainty 20 to 30 °C, fc=50 MHz, Preamp Off, Relative to 20 dB attenuation, Input attenuation 1 to 51 dB ± 0.5 dB

Dynamic Range Specifications

1 dB gain compression

20 to 30 °C, fc ≥ 50 MHz, Input attenuation 0 dB, Preamp off

> -5 dBm, Nominal

Displayed average noise level (DANL)

20 to 30 °C, 0dB RF attenuation, RBW=1 Hz, VBW=1 Hz, sample detector, average > 50

UTS3015T+ UTS3032T+
Preamp off
9 kHz to 500 kHz -130 dBm (Nominal) -105 dBm (Nominal)
500 kHz to 1 MHz -143 dBm, -145 dBm (Typical) -115 dBm, -120 dBm (Typical)
1 MHz to 10 MHz -142 dBm, -144 dBm (Typical) -127 dBm, -130 dBm (Typical)
10 MHz to 200 MHz -142 dBm, -143 dBm (Typical) -142 dBm, -145 dBm (Typical)
200 MHz to 1.5 GHz -140 dBm, -142 dBm (Typical) -143 dBm, -146 dBm (Typical)
1.5 GHz to 3.2 GHz --- -140dBm,-143dBm (Typical)
Preamp on
9 kHz to 500 kHz -145 dBm (Nominal) -125 dBm (Nominal)
500 kHz to 1 MHz -155 dBm, -157 dBm (Typical) -130 dBm, -135 dBm (Typical)
1 MHz to 10 MHz -155 dBm, -158 dBm (Typical) -145 dBm, -147 dBm (Typical)
10 MHz to 200 MHz -158 dBm, -160 dBm (Typical) -158 dBm, -160 dBm (Typical)
200 MHz to 1.5 GHz -159 dBm, -161 dBm (Typical) -161 dBm, -164 dBm (Typical)
1.5 GHz to 3.2 GHz -159 dBm, -161 dBm (Typical) -159 dBm, -161 dBm (Typical)

Spurious responses

Second harmonic distortion (SHI)

20 to 30 °C, Preamp off, Signal input-30 dBm, 0dB RF attenuation

Absolute amplitude Precision 20 to 30 °C, fc=50 MHz, RBW=1 kHz, VBW=1 kHz, Peak detectors, Input attenuation20 dB ± 0.4 dB, Input signal level -20 dBm, Preamp Off
± 0.5 dB, Input signal level -40 dBm, Preamp On
Total absolute amplitude Precision 20 to 30 °C, fc > 100 kHz, Input signal level -50 dBm to 0 dBm, RBW = 1 kHz, VBW = 1 kHz, Peak detectors, Input attenuation 20 dB, Preamp Off, 95% confidence ± (0.4 dB+ Frequency response)
Input voltage standing wave ratio (VSWR) 1 MHz to 1.5 GHz ≤ 1.8 (Nominal)
1 MHz to 3.2 GHz ≤ .8 (Nominal)

Phase noise

20 to 30 °C, fc = 1 GHz, RBW=1 kHz, VBW=10 Hz, Sampling detection, Log avg, avg> 50

Offset UTS3015T+ UTS3032T+
10 kHz -95 dBc/Hz, -98 dBc/Hz (Typical) -95 dBc/Hz, -98 dBc/Hz (Typical)
100 kHz -96 dBc/Hz, -98 dBc/Hz (Typical) -93 dBc/Hz, -98 dBc/Hz (Typical)
1 MHz -115 dBc/Hz, -120 dBc/Hz (Typical) -115 dBc/Hz, -120 dBc/Hz (Typical)

Tracking Generator Specifications

Frequency

Frequency range 100 kHz to 1.5 GHz 10 MHz to 3.2 GHz
Counter resolution 10 Hz
Output power level -40 dBm to 0 dBm 0.5 dB
Resolution be relative to 50 MHz
Flatness output ± 3 dB
Maximum safe reverse input level
Average total power 30 dBm
AC coupling ±50 VDC

Analog Demodulation Analysis (Option)

Demodulation

Frequency range 2 MHz to 1.5 GHz 2 MHz to 3.2 GHz
Carrier power Precision ± 2 dB
Input power -30 dB to +20 dBm Automatic attenuation
Carrier power display resolution 0.01 dBm
AM measurement
Modulation rate 20 Hz to 100 kHz Modulation rate <1 kHz
Precision 1 Hz (Nominal) < 0.1%Modulation rate (Nominal) Modulation rate ≥1 kHz
Depth 5 to 95%
Precision ± 4% (Nominal)
FM measurement
Modulation rate 20 Hz to 100 kHz Modulation rate < 1 kHz
Precision 1 Hz (Nominal) < 0.1% Modulation rate (Nominal) Modulation rate ≥ 1 kHz
Frequency offset 1 kHz to 400 kHz
Precision ± 4% (Nominal)

EMI (Option)

EMI Resolution bandwidth

Resolution bandwidth (-6dB) 200 Hz, 9 kHz, 120 kHz, 1 MHz
Resolution bandwidth Precision < 5%, (Nominal)

EMI detector

EMI detector: Peak, Negative Peak, Quasi Peak, EMI Average, Average

EMI Main function

Main function: EMI Standard: CISPR; View: Scan table, Meter, Signal table; Meter control; Avg settings; Limit: AS-NZS, BellCore, DEF-STAN, DO-160, EN, FCC, GB9254, MIL-461, VCCI and Custom; Signal table settings; Scan table settings; Scan Sequence: Scan, Search, Scan-Search-Meas, Scan-Search, Search-Meas, Measure; Sig Detector; Output report

Reflection measurement

Incentive and reflex measurement

Cursor measurement VSWR, Return loss, Reflection coefficient
Calibration type Open
Excitation power -20 to 0 dBm

Advanced measurement kit (Option)

Power Measurement

Channel power Channel power, Power spectral density
ACP (Adjacent Channel Power) Main CH Power, Left channel power, Right channel power
Occupied bandwidth Occupied Bandwidth, Transmit Frequency Error
Time domain power Zero Span Integrated Power
CNR (Carrier Noise Ratio) C/N, Noise Power

Non-Linear Measurement

TOI, Third-order intercept Measure the third-order products from two tones
Harmonic measurement Max Harmonic number 10

Spectrum Monitor Measurement

Spectrogram

Interface and display

Common interface

RF input Type-N female, 50 Ω, nominal
Front panel trace source output Type-N female, 50 Ω, nominal
10 MHz Ext Ref In 10 MHz, > 0 dBm, BNC female, 50 Ω, nominal
10 MHz out 10 MHz, -5 dBm to +10 dBm, BNC female, 50 Ω, nominal
External trigger input TTL, BNC female
HDMI display HDMI 1.4 display interface
USB-Host USB-A
USB-Device USB-B
LAN LAN (VXI11), 10/100/1,000 Base, RJ-45
Headphone Jack 3.5 mm (1/8 inch) miniature stereo audio jack

Display screen

Display type 10.1-inch capacitive multi-touch panel
Display resolution 1280×800, RGB Vertical pixel

General Technical Specifications

Specifications

Supply voltage 100 to 240 VAC (Fluctuations ± 10%) 100 to 120 VAC (Fluctuations ± 10%)
Frequency 50/60 Hz 400 Hz
Environment
Temperature range operation: 0°C to +40°C
Non-operating: -20°C to +70°C
Cooling method Fan forced cooling
Humidity range Operation: Below + 35 °C ≤ 90% relative humidity; Non-operating: + 35 °C to +40 °C ≤ 60% relative humidity
Altitude Operation: Below 3,000 m; Non-operating: Below 15,000 m
Pollution degree 2
Operating environment Indoor use
Mechanical specifications
Dimensions 378mm×218mm×120mm (Width x Height x Length)
Net weight 4.55 kg
Calibration period The recommended calibration period is one year

Regulatory standards

EMC

Compliance with EMC directives(2014/30/EU), Conform to or better than IEC 61326-1:2021/EN61326-1:2021, IEC 61326-2-1:2021/EN61326-2-1:2021

Conductive disturbance CISPR 11/EN 55011 CLASS B group 1, 150kHz-30MHz
Radiation disturbance CISPR 11/EN 55011 CLASS B group 1, 30MHz-1GHz
(ESD)Electrostatic discharge (ESD) IEC 61000-4-2/EN 61000-4-2 ±4.0 kV (Contact), ±8.0 kV (air)
Radio frequency electromagnetic field immunity IEC 61000-4-3/EN 61000-4-3 3 V/m (80 MHz to 1 GHz) ; 0 V/m (1.4 GHz to 6 GHz)
(EFT)Electrical fast transient burst (EFT) IEC 61000-4-4/EN 61000-4-4 ±1 kV (AC input port)
Surge IEC 61000-4-5/EN 61000-4-5 ±0.5 kV (Live line to zero line) ±1 kV (Fire/zero line to ground)
Immunity to RF continuous conduction IEC 61000-4-6/EN 61000-4-6 3 V, 0.15-80 MHz
Voltage dips and short interruptions IEC 61000-4-11/EN 61000-4-11 Voltage dip: 0% UT during 0.5 cycle; 0% UT during 1 cycle; 70% UT during 25/30 cycles Short Interruption: 0% UT during 250/300 cycles

Safety regulations

EN 61010-1:2010+A1:2019

EN IEC61010-2-030:2021+A11:2021

UL 61010-1:2012 Ed.3+ R:19 Jul2019

UL 61010-2-030:2018 Ed.2

CSA C22.2#61010-1:2012 Ed.3+U1;U2;A1

CSA C22.2#61010-2-030:2018 Ed.2

Order Information

Description Order No.
Spectrum analyzer, 9 kHz to 1.5 GHz UTS3015T+
Spectrum analyzer, 9 kHz to 3.2 GHz UTS3032T+
Standard accessories Power cord ×1 USB cable x1 UT-D14

Recommended options & accessories

Options Advanced measurement kit UTS3000-AMK
EMI measurement option UTS3000-EMI
Analog demodulation analysis option UTS3000-AMA
UT-CK01 accessories kit SMAJ-NJ-0.7M DC-6G cable x1 UT-W02-6GHz
NJ-NJ-0.7M DC-6G cable x1 UT-W01-6GHz
Adapter SMA-N-KJ-T DC-6GHz x2 UT-C01-6GHz
Adapter N-BNC-JK DC-4GHz x2 UT-C02-4GHz
Antenna 2400 MHz-2500 MHz x2 UTS-T01
Antenna 824-960 MHz/1710-1990 MHz x2 UTS-T02
50Ω-SMA-SMB cable x1 UT-W03
UTS-EMI01 Adapter SMA-N-KJ-T DC-6 GHz x1 UT-C01
Near field probe, frequency range 30 MHz-3 GHz, Detection range 10 cm x1 NFP-3G-P1
Near field probe, frequency range 30 MHz-3 GHz, Detection range 3 cm x1 NFP-3G-P2
Near-field probes kit Near field probe, frequency range 30 MHz-2 GHz, resolving power 5 mm x1 NFP-2G-P3
Near field probe, frequency range 30 MHz-3 GHz, resolving power 2 mm x1 NFP-3G-P4
Reflection Measurement VSWR bridge UT-RB60

Options ordering and installation

  1. Purchase options: Based on your requirements, please purchase the specified function options from Uni-t Sales Personnel and provide the serial number of the instrument that needs the option installed.
  2. Receive certificate: You will receive the license certificate based on the address provided in the order.
  3. Register and obtain license: Visit the Uni-t official website license activation session for registration. Use the license key and instrument serial number provided in the certificate to obtain the option license code and license file.
  4. Install the option: Download the option license file to the root directory of a USB storage device, and connect the USB storage device to the instrument. Once the USB storage device is recognized, the Option Install menu will be activated. Press this menu key to begin installing the option.

Limited Warranty and Liability

UNI-T guarantees that the Instrument product is free from any defect in material and workmanship within three years from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination, or improper handling. If you need a warranty service within the warranty period, please contact your seller directly. UNI-T will not be responsible for any special, indirect, incidental, or subsequent damage or loss caused by using this device. For the probes and accessories, the warranty period is one year. Visit instrument.uni-trend.com for full warranty information.

Learn more at: www.uni-trend.com

Register your product to confirm your ownership. You will also get product notifications, update alerts, exclusive offers and all the latest information you need to know.

UNI-T is the licensed trademark of UNI-TREND TECHNOLOGY (CHINA) CO., Ltd. UNI-T products are protected under patent laws in China and internationally, covering both granted and pending patents. Licensed software products are the properties of UNI-Trend and its subsidiaries or suppliers, all rights reserved. This manual contains information that replaces all earlier published versions. The product information in this document subject to update without notice. For more information on UNI-T Test & Measure Instrument products, applications, or service, please contact UNI-T instrument for support, the support center is available on www.uni-trend.com ->instruments.uni-trend.com https://instruments.uni-trend.com/ContactForm/

Headquarter

UNI-TREND TECHNOLOGY (CHINA) CO., Ltd.

Address: No.6, Industrial North 1st Road, Songshan Lake Park, Dongguan City, Guangdong Province, China

Tel: (86-769) 8572 3888

Europe

UNI-TREND TECHNOLOGY EU GmbH

Address: Steinerne Furt 62, 86167 Augsburg, Germany

Tel: +49 (0)821 8879980

North America

UNI-TREND TECHNOLOGY US INC.

Address: 2692 Gravel Drive, Building 5, Fort Worth, Texas 76118

Tel: +1-888-668-8648

Copyright © 2025 by UNI-Trend Technology (China) Co., Ltd. All rights reserved.

PDF preview unavailable. Download the PDF instead.

085605fafbb152ac30c4b4ee01406 WPS 文字

Related Documents

Preview UTS3000T+ Series Spectrum Analyzer Data Sheet
Comprehensive data sheet for the UNI-T UTS3000T+ Series Spectrum Analyzer, detailing product features, specifications, and ordering information for models UTS3036T+ and UTS3084T+.
Preview UTS1000B/T Series Spectrum Analyzer Datasheet
Datasheet for the UNI-T UTS1000B/T Series Spectrum Analyzer, detailing its features, specifications, and options. Covers frequency and time specifications, amplitude precision, dynamic range, phase noise, and regulatory standards.
Preview UTS3000B Series Spectrum Analyzer User's Manual
User's manual for the UNI-T UTS3000B Series Spectrum Analyzer, detailing its functions, features, front and rear panel operations, and safety precautions.
Preview MSO3000HD Series High-Resolution Oscilloscope Datasheet
Datasheet for the UNI-T MSO3000HD Series High-Resolution Oscilloscope, detailing its features, specifications, and applications including digital oscilloscope, logic analyzer, and power analyzer functions.
Preview UNI-T MSO3000HD Series High-Resolution Oscilloscope Datasheet
Explore the UNI-T MSO3000HD Series High-Resolution Oscilloscope Datasheet. Discover its advanced features, including a 500 MHz bandwidth, 2.5 GSa/s sampling rate, 12-bit resolution, and a 10.1-inch capacitive touch screen. Learn about its multiple instrument functions, such as digital oscilloscope, logic analyzer, and spectrum analyzer, designed for efficient and versatile operation.
Preview UNI-T MSO1000HD Series High-Resolution Oscilloscopes Datasheet
Comprehensive datasheet for the UNI-T MSO1000HD Series High-Resolution Oscilloscopes, detailing features, specifications, performance characteristics, application scopes, and accessories.
Preview UNI-T MSO1000HD Series High-Resolution Oscilloscopes Data Sheet
Data sheet for the UNI-T MSO1000HD Series High-Resolution Oscilloscopes, detailing features, specifications, performance characteristics, and accessories.
Preview UNI-T MSO1000HD Series High-Resolution Oscilloscopes Data Sheet
Comprehensive data sheet for the UNI-T MSO1000HD Series High-Resolution Oscilloscopes, detailing features, specifications, performance characteristics, probes, accessories, and order information.