TÜV Rheinland Test Report

Product: Wireless charger (VÄSTMÄRKE)

Model/Type No.: E2400-P

Test Report No.: CN25BIL1 002

Client: IKEA of Sweden AB

Date of Issue: 2025-06-18

General Remarks

All equipment used during the specified testing period was calibrated according to the test laboratory calibration program. The equipment fulfills the requirements included in the relevant standards. Traceability of the test equipment is ensured by compliance with the management system regulations. Detailed information regarding test conditions, equipment, and measurement uncertainty is available in the test laboratory and can be provided upon request.

This document has been signed digitally. TÜV Rheinland has not verified, and is unable to verify, legal or other pertaining requirements applicable to this document. Verification is the responsibility of the document user. Upon request, TÜV Rheinland can confirm the validity of the digital signature via a separate document, which requires contacting their Sales department. An environmental fee applies for this additional service. For information on verifying document authenticity, visit: go.tuv.com/digital-signature.

Test clauses marked with * were subcontracted to qualified subcontractors and are described under the respective test clause in the report. Deviations from testing specifications or customer requirements are listed in specific test clauses within the report.

The decision rule for conformity statements based on numerical measurement results in this report follows the "Zero Guard Band Rule" and "Simple Acceptance" in accordance with ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified in the applied standard or requested by the customer. This implies that measurement uncertainty is not considered or declared. For details on the resulting risk, refer to ILAC G8:2019.

Test Sites

Test Facilities

TÜV Rheinland (Shenzhen) Co., Ltd.
2-3F, 101 & 102, No.2, Nuclear Power Industrial Park, Fuming Community, Fucheng Street, Longhua District, Shenzhen 518000, People's Republic of China
A2LA Certificate Number: 5162.01

List of Test and Measurement Instruments

Equip. No. Description Manufacturer Model Serial No. Cal. Date Cal. Due
9050046 Electric and Magnetic Field Analyzer Narda EHP200A 180ZX20517 22.09.2023 21.09.2025

Traceability

All measurement equipment calibrations are traceable to NIM (National Institute of Metrology) or equivalent nationally recognized standards organizations.

Calibration

Equipment requiring calibration is calibrated periodically by the manufacturer or according to manufacturer's specifications. All equipment is verified for proper performance using in-house standards or comparisons.

Measurement Uncertainty

The estimated combined standard uncertainty for radiated emissions and conducted emissions measurements is detailed below:

Parameter Uncertainty
Magnetic Field Emissions (A/m) 1.5dB
Electric Field Emissions (V/m) 1.5dB

Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Location of Original Data

Original copies of all test data were attached at Appendix A of this report and delivered to the applicant. A copy is retained by TÜV Rheinland (Shenzhen) Co., Ltd. for certification follow-up.

Status of Facility Used for Testing

The TÜV Rheinland (Shenzhen) Co., Ltd. test facility is listed on the US Federal Communications Commission list of facilities approved to perform measurements.

General Product Information

Product Function and Intended Use

The EUT is a Wireless charger that supports wireless charging (WPT) function. For details, refer to the User Manual, Technical Description, and Circuit Diagram.

Ratings and System Details

General Information of EUT Value
Kind of Equipment Wireless charger (VÄSTMÄRKE)
Type Designation E2400-P
FCC ID FHO-E2400-P
Operating Voltage 5.0V-3A, 9.0V-2.2A
Test Voltage AC 120V, 60Hz (power supply to external adapter)
Operating Temperature Range 0°C~+40 °C
Wireless output power 5.0W/7.5W/10W/15.0W Output: 15.0W Max
Technical Specification of WPT Output
Frequency Range 110.5kHz to 205kHz
Type of Modulation FSK
Antenna Type Coil antenna
Antenna Number 1
Wireless output power 110.5kHz to 205kHz: 5W, 7.5W, 10W
360kHz: 15W

Noise Generating and Noise Suppressing Parts

Refer to Circuit Diagram for further details.

Submitted Documents

Special Accessories and Auxiliary Equipment

Description Manufacturer Model No. Note
iPhone 14 Plus Apple MQ3D3CH/A n/a
iPhone 11 Apple MHF13CH/A n/a
AC/DC Adapter IKEA E2501-NA Input: AC 110-240V, 50/60Hz
Output:
5.0 V, 3.0 A, 15.0 W,
9.0 V, 2.22 A, 20.0 W,
12.0 V, 1.67 A, 20.0 W,
15.0 V, 1.33 A, 20.0 W

Radio Frequency Exposure Compliance

Test Procedures According to the Technical Standards

Standard Section Test Item Judgment
FCC CFR 47 part1, 1.1310
KDB 680106 D01 Wireless Power Transfer v04
Electric Field Strength (E) (V/m)
Magnetic Field Strength (H) (A/m)
PASS
PASS

Limit of Maximum Permissible Exposure

Limits for Occupational / Controlled Exposure

Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm²) Averaging Time |E|², |H|² or S (minutes)
0.3-3.0 614 1.63 (100)* 6
3.0-30 1842/f 4.89/f (900 / f)* 6
30-300 61.4 0.163 1.0 6
300-1500 F/300 6
1500-100,000 5 6

Limits for General Population / Uncontrolled Exposure

Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm²) Averaging Time |E|², |H|² or S (minutes)
0.3-1.34 614 1.63 (100)* 30
1.34-30 824/f 2.19/f (180 / f)* 30
30-300 27.5 0.073 0.2 30
300-1500 F/1500 30
1500-100,000 1 30

Note 1: f = frequency in MHz; *Plane-wave equivalent power density.

Note 2: For the applicable limit, see FCC 1.1310, KDB 680106 D01 Wireless Power Transfer v04.

Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz.

Test Result

Test Frequency E-field strength (V/m)
110kHz to 205kHz (5W) 110kHz to 205kHz (10W) 360kHz (15W)
Front 1.359 2.338 5.095
Back 1.624 1.468 3.582
Left 1.676 1.583 3.508
Right 1.312 1.748 3.902
Top 1.272 1.285 5.132
Bottom 1.282 0.981 2.795
Limits (V/m) 614 614 614
Test Frequency H-field strength (A/m)
Front 0.086 0.095 0.062
Back 0.062 0.087 0.057
Left 0.071 0.088 0.059
Right 0.093 0.133 0.062
Top 0.132 0.184 0.101
Bottom 0.198 0.279 0.181
Limits (A/m) 1.63 1.63 1.63

Test distance=10 cm

Photographs of the Test Set-Up

For photographs of the test set-up, refer to the appendix A.

List of Tables

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8479791 PDF Printer / www.bullzip.com / FPG / TUV Rheinland Service GmbH; modified using iText 4.2.2 by 1T3XT, AuthentiDate

Related Documents

Preview IKEA of Sweden AB Authorization to Act as Agent for FCC Certification
Official authorization letter from IKEA of Sweden AB appointing TÜV Rheinland as agent for equipment certification, including statements on FCC compliance and federal benefits.
Preview TUV Rheinland Test Report for IKEA Wireless Charger E2400-P
This document contains the official test report from TUV Rheinland for the IKEA E2400-P wireless charger, detailing conducted and radiated emission test results.
Preview IKEA E2400-P Wireless Charger Test Report
Official test report for the IKEA E2400-P wireless charger, detailing compliance with FCC Part 15 regulations. Includes test results for antenna requirement, 20dB bandwidth, radiated spurious emission, and conducted emission on AC mains.
Preview IKEA E2400-P Wireless Charger: Specifications, Markings, and Dimensions
Detailed technical specifications, regional compliance markings (EU, NA), FCC/IC IDs, and dimensional information for the IKEA E2400-P wireless charger.
Preview IKEA FHO-E2400-P Attestation Statement - Not Covered Equipment
Attestation statement from IKEA of Sweden AB for the FHO-E2400-P equipment, confirming it is not 'covered equipment' as per FCC Section 2.903.
Preview TÜV Rheinland Test Report for IKEA Wireless Charger E2400-S
This report details the test results for the IKEA E2400-S wireless charger, covering RF exposure compliance and technical specifications.
Preview IKEA E2400-P Wireless Charger: U.S. Agent Designation for Service of Process
Official designation of a U.S. Agent for Service of Process for IKEA of Sweden AB's E2400-P Wireless Charger (VASTMARKE), filed with the Federal Communications Commission (FCC).
Preview Confidentiality Request for FCC ID FHO-E2400-P - IKEA of Sweden AB
Confidentiality request submitted by IKEA of Sweden AB to the Federal Communications Commission for FCC ID FHO-E2400-P, detailing exhibits to be withheld from public view.