TÜV Rheinland Test Report
Product: Wireless charger (VÄSTMÄRKE)
Model/Type No.: E2400-P
Test Report No.: CN25BIL1 002
Client: IKEA of Sweden AB
Date of Issue: 2025-06-18
General Remarks
All equipment used during the specified testing period was calibrated according to the test laboratory calibration program. The equipment fulfills the requirements included in the relevant standards. Traceability of the test equipment is ensured by compliance with the management system regulations. Detailed information regarding test conditions, equipment, and measurement uncertainty is available in the test laboratory and can be provided upon request.
This document has been signed digitally. TÜV Rheinland has not verified, and is unable to verify, legal or other pertaining requirements applicable to this document. Verification is the responsibility of the document user. Upon request, TÜV Rheinland can confirm the validity of the digital signature via a separate document, which requires contacting their Sales department. An environmental fee applies for this additional service. For information on verifying document authenticity, visit: go.tuv.com/digital-signature.
Test clauses marked with * were subcontracted to qualified subcontractors and are described under the respective test clause in the report. Deviations from testing specifications or customer requirements are listed in specific test clauses within the report.
The decision rule for conformity statements based on numerical measurement results in this report follows the "Zero Guard Band Rule" and "Simple Acceptance" in accordance with ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified in the applied standard or requested by the customer. This implies that measurement uncertainty is not considered or declared. For details on the resulting risk, refer to ILAC G8:2019.
Test Sites
Test Facilities
TÜV Rheinland (Shenzhen) Co., Ltd.
2-3F, 101 & 102, No.2, Nuclear Power Industrial Park, Fuming Community, Fucheng Street, Longhua District, Shenzhen 518000, People's Republic of China
A2LA Certificate Number: 5162.01
List of Test and Measurement Instruments
Equip. No. | Description | Manufacturer | Model | Serial No. | Cal. Date | Cal. Due |
---|---|---|---|---|---|---|
9050046 | Electric and Magnetic Field Analyzer | Narda | EHP200A | 180ZX20517 | 22.09.2023 | 21.09.2025 |
Traceability
All measurement equipment calibrations are traceable to NIM (National Institute of Metrology) or equivalent nationally recognized standards organizations.
Calibration
Equipment requiring calibration is calibrated periodically by the manufacturer or according to manufacturer's specifications. All equipment is verified for proper performance using in-house standards or comparisons.
Measurement Uncertainty
The estimated combined standard uncertainty for radiated emissions and conducted emissions measurements is detailed below:
Parameter | Uncertainty |
---|---|
Magnetic Field Emissions (A/m) | 1.5dB |
Electric Field Emissions (V/m) | 1.5dB |
Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.
Location of Original Data
Original copies of all test data were attached at Appendix A of this report and delivered to the applicant. A copy is retained by TÜV Rheinland (Shenzhen) Co., Ltd. for certification follow-up.
Status of Facility Used for Testing
The TÜV Rheinland (Shenzhen) Co., Ltd. test facility is listed on the US Federal Communications Commission list of facilities approved to perform measurements.
General Product Information
Product Function and Intended Use
The EUT is a Wireless charger that supports wireless charging (WPT) function. For details, refer to the User Manual, Technical Description, and Circuit Diagram.
Ratings and System Details
General Information of EUT | Value |
---|---|
Kind of Equipment | Wireless charger (VÄSTMÄRKE) |
Type Designation | E2400-P |
FCC ID | FHO-E2400-P |
Operating Voltage | 5.0V-3A, 9.0V-2.2A |
Test Voltage | AC 120V, 60Hz (power supply to external adapter) |
Operating Temperature Range | 0°C~+40 °C |
Wireless output power | 5.0W/7.5W/10W/15.0W Output: 15.0W Max |
Technical Specification of WPT | Output |
---|---|
Frequency Range | 110.5kHz to 205kHz |
Type of Modulation | FSK |
Antenna Type | Coil antenna |
Antenna Number | 1 |
Wireless output power | 110.5kHz to 205kHz: 5W, 7.5W, 10W 360kHz: 15W |
Noise Generating and Noise Suppressing Parts
Refer to Circuit Diagram for further details.
Submitted Documents
- Application Form
- Block Diagram
- ID Label and Location Info
- User Manual
- Schematics
- Operation Description
Special Accessories and Auxiliary Equipment
Description | Manufacturer | Model No. | Note |
---|---|---|---|
iPhone 14 Plus | Apple | MQ3D3CH/A | n/a |
iPhone 11 | Apple | MHF13CH/A | n/a |
AC/DC Adapter | IKEA | E2501-NA | Input: AC 110-240V, 50/60Hz Output: 5.0 V, 3.0 A, 15.0 W, 9.0 V, 2.22 A, 20.0 W, 12.0 V, 1.67 A, 20.0 W, 15.0 V, 1.33 A, 20.0 W |
Radio Frequency Exposure Compliance
Test Procedures According to the Technical Standards
Standard Section | Test Item | Judgment |
---|---|---|
FCC CFR 47 part1, 1.1310 KDB 680106 D01 Wireless Power Transfer v04 |
Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) |
PASS PASS |
Limit of Maximum Permissible Exposure
Limits for Occupational / Controlled Exposure
Frequency Range (MHz) | Electric Field Strength (E) (V/m) | Magnetic Field Strength (H) (A/m) | Power Density (S) (mW/cm²) | Averaging Time |E|², |H|² or S (minutes) |
---|---|---|---|---|
0.3-3.0 | 614 | 1.63 | (100)* | 6 |
3.0-30 | 1842/f | 4.89/f | (900 / f)* | 6 |
30-300 | 61.4 | 0.163 | 1.0 | 6 |
300-1500 | F/300 | 6 | ||
1500-100,000 | 5 | 6 |
Limits for General Population / Uncontrolled Exposure
Frequency Range (MHz) | Electric Field Strength (E) (V/m) | Magnetic Field Strength (H) (A/m) | Power Density (S) (mW/cm²) | Averaging Time |E|², |H|² or S (minutes) |
---|---|---|---|---|
0.3-1.34 | 614 | 1.63 | (100)* | 30 |
1.34-30 | 824/f | 2.19/f | (180 / f)* | 30 |
30-300 | 27.5 | 0.073 | 0.2 | 30 |
300-1500 | F/1500 | 30 | ||
1500-100,000 | 1 | 30 |
Note 1: f = frequency in MHz; *Plane-wave equivalent power density.
Note 2: For the applicable limit, see FCC 1.1310, KDB 680106 D01 Wireless Power Transfer v04.
Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz.
Test Result
Test Frequency | E-field strength (V/m) | ||
---|---|---|---|
110kHz to 205kHz (5W) | 110kHz to 205kHz (10W) | 360kHz (15W) | |
Front | 1.359 | 2.338 | 5.095 |
Back | 1.624 | 1.468 | 3.582 |
Left | 1.676 | 1.583 | 3.508 |
Right | 1.312 | 1.748 | 3.902 |
Top | 1.272 | 1.285 | 5.132 |
Bottom | 1.282 | 0.981 | 2.795 |
Limits (V/m) | 614 | 614 | 614 |
Test Frequency | H-field strength (A/m) | ||
---|---|---|---|
Front | 0.086 | 0.095 | 0.062 |
Back | 0.062 | 0.087 | 0.057 |
Left | 0.071 | 0.088 | 0.059 |
Right | 0.093 | 0.133 | 0.062 |
Top | 0.132 | 0.184 | 0.101 |
Bottom | 0.198 | 0.279 | 0.181 |
Limits (A/m) | 1.63 | 1.63 | 1.63 |
Test distance=10 cm
Photographs of the Test Set-Up
For photographs of the test set-up, refer to the appendix A.
List of Tables
- Table 1: List of Test and Measurement Equipment
- Table 2: Measurement Uncertainty
- Table 3: Technical Specification of EUT
Related Documents
![]() |
IKEA of Sweden AB Authorization to Act as Agent for FCC Certification Official authorization letter from IKEA of Sweden AB appointing TÜV Rheinland as agent for equipment certification, including statements on FCC compliance and federal benefits. |
![]() |
TUV Rheinland Test Report for IKEA Wireless Charger E2400-P This document contains the official test report from TUV Rheinland for the IKEA E2400-P wireless charger, detailing conducted and radiated emission test results. |
![]() |
IKEA E2400-P Wireless Charger Test Report Official test report for the IKEA E2400-P wireless charger, detailing compliance with FCC Part 15 regulations. Includes test results for antenna requirement, 20dB bandwidth, radiated spurious emission, and conducted emission on AC mains. |
![]() |
IKEA E2400-P Wireless Charger: Specifications, Markings, and Dimensions Detailed technical specifications, regional compliance markings (EU, NA), FCC/IC IDs, and dimensional information for the IKEA E2400-P wireless charger. |
![]() |
IKEA FHO-E2400-P Attestation Statement - Not Covered Equipment Attestation statement from IKEA of Sweden AB for the FHO-E2400-P equipment, confirming it is not 'covered equipment' as per FCC Section 2.903. |
![]() |
TÜV Rheinland Test Report for IKEA Wireless Charger E2400-S This report details the test results for the IKEA E2400-S wireless charger, covering RF exposure compliance and technical specifications. |
![]() |
IKEA E2400-P Wireless Charger: U.S. Agent Designation for Service of Process Official designation of a U.S. Agent for Service of Process for IKEA of Sweden AB's E2400-P Wireless Charger (VASTMARKE), filed with the Federal Communications Commission (FCC). |
![]() |
Confidentiality Request for FCC ID FHO-E2400-P - IKEA of Sweden AB Confidentiality request submitted by IKEA of Sweden AB to the Federal Communications Commission for FCC ID FHO-E2400-P, detailing exhibits to be withheld from public view. |