TÜV Rheinland Test Report

Test Report Number: CN254C3H 002

Product Information

Client: IKEA of Sweden AB

Address: Box 702, SE-343 81, Älmhult, Sweden

Test Item: Wireless charger (VÄSTMÄRKE)

Identification / Type No.: E2400-S

FCC ID: FHO-E2400-S

Order Content: Test Report

Test Specification: CFR47 FCC Part 2.1093, KDB 680106 D01 Wireless Power Transfer v04

Date of Sample Receipt: 2024-10-30

Testing Period: 2024-10-30 - 2025-06-13

Place of Testing: TÜV Rheinland (Shenzhen) Co., Ltd.

Testing Laboratory: TÜV Rheinland (Shenzhen) Co., Ltd.

Test Result: Pass

Tested By: Lady Hardy Suo

Authorized By: Lin Lin

Issue Date: 2025-06-18

General Remarks

All equipment used during the specified testing period was calibrated according to the test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request.

This document has been signed digitally. TUV Rheinland has not verified and is unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. For information on verifying the authenticity of our documents, please visit: go.tuv.com/digital-signature.

Test clauses with remark of * are subcontracted to qualified subcontractors and described under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report.

The decision rule for statements of conformity, based on numerical measurement results, in this test report is based on the “Zero Guard Band Rule” and “Simple Acceptance” in accordance with ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified in the applied standard mentioned on Page 1 of this report or requested by the customer. This means that measurement uncertainty is not taken into account and hence also not declared in the test report. For additional information to the resulting risk based of this decision rule please refer to ILAC G8:2019.

Test Sites

Test Facilities: TÜV Rheinland (Shenzhen) Co., Ltd., 2-3F, 101 & 102, No.2, Nuclear Power Industrial Park, Fuming Community, Fucheng Street, Longhua District, Shenzhen 518000, People's Republic of China. A2LA Certificate Number: 5162.01

The TÜV Rheinland (Shenzhen) Co., Ltd. test facility is listed on the US Federal Communications Commission list of facilities approved to perform measurements.

Test and Measurement Instruments

Table 1: List of Test and Measurement Equipment

Equip. No. Description Manufacturer Model Serial No. Cal. Date Cal. Due
9050046 Electric and Magnetic Field Analyzer Narda EHP200A 180ZX20517 22.09.2023 21.09.2025

All measurement equipment calibrations are traceable to NIM (National Institute of Metrology) or to equivalent nationally recognized standards organizations.

Equipment requiring calibration is calibrated periodically by the manufacturer or according to manufacturer's specifications. All equipment is verified for proper performance on a regular basis using in-house standards or comparisons.

Measurement Uncertainty

Table 2: Measurement Uncertainty

Parameter Uncertainty
Magnetic Field Emissions (A/m) 1.5dB
Electric Field Emissions (V/m) 1.5dB

Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Location of Original Data

The original copies of all test data taken during actual testing were attached at Appendix A of this report and delivered to the applicant. A copy has been retained in the TÜV Rheinland (Shenzhen) Co., Ltd. file for certification follow-up purposes.

General Product Information

3.1 Product Function and Intended Use

The EUT is a Wireless charger, which supports wireless charging (WPT) function. For details refer to the User Manual, Technical Description and Circuit Diagram.

3.2 Ratings and System Details

Table 3: Technical Specification of EUT

General Information of EUT Value
Kind of Equipment: Wireless charger (VÄSTMÄRKE)
Type Designation: E2400-S
FCC ID: FHO-E2400-S
Operating Voltage: 5.0V-3A, 9.0V-2.2A
Test Voltage: AC 120V, 60Hz (power supply to external adapter)
Operating Temperature Range: 0°C~+40 °C
Wireless output power: 5.0W/7.5W/10W/15.0W Output: 15.0W Max

Technical Specification of WPT

Output Value
Frequency Range: 110.5kHz to 205kHz, 360kHz
Type of Modulation: FSK
Antenna Type: Coil antenna
Antenna Number: 1
Wireless output power: 110.5kHz to 205kHz: 5W, 7.5W, 10W; 360kHz: 15W

3.3 Noise Generating and Noise Suppressing Parts

Refer to Circuit Diagram for further details.

3.4 Submitted Documents

Special Accessories and Auxiliary Equipment

Description Manufacturer Model No. Note
iPhone 14 Plus Apple MQ3D3CH/A n/a
iPhone 11 Apple MHF13CH/A n/a
AC/DC Adapter IKEA E2501-NA Input: AC 110-240V, 50/60Hz
Output: 5.0V, 3.0A, 15.0W;
9.0V, 2.22A, 20.0W;
12.0V, 1.67A, 20.0W;
15.0V, 1.33A, 20.0W

Radio Frequency Exposure Compliance

4.1 Test Procedures According to the Technical Standards

Standard Section Test Item Judgment
FCC CFR 47 part1, 1.1310 KDB 680106 D01 Wireless Power Transfer v04 Electric Field Strength (E) (V/m) PASS
Magnetic Field Strength (H) (A/m) PASS

4.2 Limit of Maximum Permissible Exposure

Limits for Occupational / Controlled Exposure

Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm²) Averaging Time |E|²,|H|² or S (minutes)
0.3-3.0 614 1.63 (100)* 6
3.0-30 1842/f 4.89/f (900 / f)* 6
30-300 61.4 0.163 1.0 6
300-1500 F/300 6
1500-100,000 5 6

Limits for General Population / Uncontrolled Exposure

Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm²) Averaging Time |E|²,|H|² or S (minutes)
0.3-1.34 614 1.63 (100)* 30
1.34-30 824/f 2.19/f (180 / f)* 30
30-300 27.5 0.073 0.2 30
300-1500 F/1500 30
1500-100,000 1 30

Note 1: f = frequency in MHz; *Plane-wave equivalent power density.

Note 2: For the applicable limit, see FCC 1.1310, KDB 680106 D01 Wireless Power Transfer v04.

Test Result

E-field strength (V/m)

Test Frequency 110kHz to 205kHz (5W) 110kHz to 205kHz (10W) 360kHz (15W)
Front 1.859 1.868 3.901
Back 0.909 0.798 2.234
Left 1.686 1.526 3.782
Right 1.216 1.811 3.698
Top 0.977 1.118 3.486
Bottom 0.790 0.735 1.254
Limits (V/m) 614 614 614

H-field strength (A/m)

Test Frequency 110kHz to 205kHz (5W) 110kHz to 205kHz (10W) 360kHz (15W)
Front 0.181 0.251 0.109
Back 0.209 0.326 0.174
Left 0.115 0.148 0.075
Right 0.092 0.134 0.068
Top 0.092 0.116 0.061
Bottom 0.065 0.078 0.051
Limits (A/m) 1.63 1.63 1.63

Test distance=10 cm

Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310:614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz.

Photographs of the Test Set-Up

For photographs of the test set-up, refer to the appendix A.

List of Tables

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8479705 PDF Printer / www.bullzip.com / FPG / TUV Rheinland Service GmbH; modified using iText 4.2.2 by 1T3XT, AuthentiDate

Related Documents

Preview IKEA of Sweden AB Authorization to Act as Agent for FCC Certification
Official authorization letter from IKEA of Sweden AB appointing TÜV Rheinland as agent for equipment certification, including statements on FCC compliance and federal benefits.
Preview IKEA E2400-S Wireless Charger Test Report
This document details the test results for the IKEA E2400-S wireless charger, covering conducted and radiated emissions according to FCC and ICES standards.
Preview IKEA E2400-S Wireless Charger Test Report
This document details the test results and compliance of the IKEA E2400-S Wireless charger (VÄSTMÄRKE) with FCC Part 15 regulations, including antenna requirement, bandwidth, radiated spurious emissions, and conducted emissions.
Preview IKEA E2400-S Wireless Charger: EU and NA Compliance Markings
Detailed overview of the compliance markings, technical specifications, and dimensional information for the IKEA E2400-S wireless charger, covering both EU and North American regions.
Preview TÜV Rheinland Test Report for IKEA Wireless Charger (VÄSTMÄRKE) E2400-P
This document contains the official test report from TÜV Rheinland for the IKEA Wireless Charger, model E2400-P (VÄSTMÄRKE). It details the product's compliance with FCC regulations, including radio frequency exposure limits.
Preview TUV Rheinland Test Report for IKEA Wireless Charger E2400-P
This document contains the official test report from TUV Rheinland for the IKEA E2400-P wireless charger, detailing conducted and radiated emission test results.
Preview TÜV Rheinland Test Report: IKEA E2400-T Wireless Charger with Light (VÄSTMÄRKE)
This report details the EMC testing conducted by TÜV Rheinland for the IKEA E2400-T Wireless Charger with Light (VÄSTMÄRKE). It covers conducted and radiated emissions according to FCC and ICES standards.
Preview IKEA E2400-T Wireless Charger with Light - Product Information
Technical specifications and regulatory information for the IKEA E2400-T wireless charger with light, including input/output power, certifications, and manufacturing details.