ClimateMaster Tranquility® (SD) Console Series
The ClimateMaster Tranquility® (SD) Console Series offers a high-efficiency Water Source Heat Pump (WSHP) ductless solution, ideal for spaces requiring individual and quiet control of heating and cooling. This series is particularly well-suited for areas with limited ceiling height and space. The Tranquility SD units exceed ASHRAE 90.1 efficiency standards and utilize R-454B refrigerant, which has a low Global Warming Potential (GWP), making it an environmentally friendly choice for space conditioning.
The SD Series Advantage
Standard Features
- All sizes from 09 (3½ ton, 2.64 kW) to 18 (1½ ton, 5.3 kW) exceed ASHRAE 90.1 efficiencies.
- High-efficiency rotary compressors.
- Galvanized steel cabinet with durable Polar Ice or Bright White powder coat finish.
- Slope top with an aluminum rigid bar supply air grille.
- TXV metering device.
- Microprocessor controls with 8 standard safeties.
- Right or left-hand piping arrangement (field-convertible).
- Front or bottom return air configuration.
- Unit Performance Sentinel™ performance monitoring system.
- Communicating CXM2 controls for reduced start-up, commissioning, and service time, including remote access and diagnosis.
Configurable Options
- Unit sub-base available in black or Bright White matte finish, with or without a fresh air motorized damper.
- UltraQuiet sound attenuation package.
- Refrigerant Detection System (RDS) available for all sizes.
- BACnet, Modbus, and Johnson Controls N2 compatibility options for Building Management Systems (BMS).
- Unit integrated power disconnect.
- High efficiency Constant Torque (CT) EC motors (standard on size 18).
- Extended range insulation for geothermal applications.
- vFlow® unit-integrated modulating water valve for maximum water-flow control.
- 115/60/1 voltage option, with or without a 20 AMP plug and cord.
Technical Specifications and Dimensional Data
Model | Motor Type | Water Loop Heat Pump | Ground Water Heat Pump | Ground Loop Heat Pump | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling 86°F Capacity (Btuh) | Cooling 86°F EER (Btuh/W) | Heating 68°F Capacity (Btuh) | Heating 68°F COP | Cooling 59°F Capacity (Btuh) | Cooling 59°F EER (Btuh/W) | Heating 50°F Capacity (Btuh) | Heating 50°F COP | Full Cooling 77°F Capacity (Btuh) | Full Cooling 77°F EER (Btuh/W) | Full Heating 32°F Capacity (Btuh) | Full Heating 32°F COP | ||
SD09 | PSC | 8,500 | 13.3 | 11,400 | 4.5 | 9,500 | 21.5 | 9,500 | 3.8 | 8,800 | 15.0 | 7,300 | 3.2 |
SD09 | EC | 8,600 | 14.0 | 11,300 | 4.6 | 9,600 | 23.0 | 9,400 | 4.0 | 8,900 | 16.5 | 7,200 | 3.3 |
SD12 | PSC | 11,300 | 13.0 | 14,300 | 4.5 | 13,000 | 19.0 | 11,800 | 3.9 | 11,800 | 15.0 | 9,200 | 3.3 |
SD12 | EC | 11,600 | 13.5 | 14,500 | 4.5 | 13,100 | 20.0 | 11,900 | 3.9 | 12,200 | 15.5 | 9,200 | 3.3 |
SD15 | PSC | 13,700 | 12.9 | 17,500 | 4.7 | 15,700 | 18.9 | 14,600 | 4.0 | 14,500 | 14.8 | 11,400 | 3.3 |
SD15 | EC | 13,800 | 13.2 | 18,000 | 4.8 | 16,000 | 19.4 | 14,700 | 4.0 | 14,700 | 15.0 | 11,500 | 3.3 |
SD18 | EC | 17,000 | 13.0 | 23,000 | 4.2 | 20,000 | 20.0 | 19,000 | 3.8 | 18,000 | 15.0 | 15,000 | 3.3 |
Notes:
- Where dual voltages are available, ratings are based on the lower voltage setting.
- Cooling capacities are based upon 80.6°F DB, 66.2°F WB entering air temperature.
- Heating capacities are based upon 68°F DB, 59°F WB entering air temperature.
- Ground Loop Heat Pump ratings are based on 15% antifreeze solution.
Dimensional Data
Overall Cabinet (inches)
Size | Model | Depth (D) | Width (W) | Height (H) |
---|---|---|---|---|
SD009-SD015 | No Subbase | 12 | 48 | 21 |
3" Subbase | 12 | 48 | 24 | |
5" Subbase | 12 | 48 | 26 | |
Extended Cabinet/No Subbase | 12 | 54 | 21 | |
Extended Cabinet/3" Subbase | 12 | 54 | 24 | |
Extended Cabinet/5" Subbase | 12 | 54 | 26 | |
SD018 | No Subbase | 12 | 54 | 21 |
5" Subbase | 12 | 54 | 26 | |
SD018 | Extended Cabinet/No Subbase | 12 | 60 | 21 |
Extended Cabinet/5" Subbase | 12 | 60 | 26 |
Note: All dimensions shown in inches.
Bottom Return (Left-Hand Piping)
Discharge air grille
Control access door
Front
Optional OA Damper
W
Front Return (Right-Hand Piping)
Discharge air grille
Control access door
Rear
8.4-13.3
15.2
1.6
Bottom access for piping and electric (note 2)
H
E
Notes:
- All dimensions are in inches. See the dimensional tables for measurements in cm.
- Access is reduced if the optional disconnect box is selected.
- The optional autoflow regulator, motorized water valve, and disconnect box are not shown.
- Filter is 1-inch (25 mm) thick fiberglass throwaway.
- Water piping is connected to associated options such as water valves, pumps, and auto-flow regulators via stainless steel braided hose kits (not shown).
- See Product Catalog or Revit files for more dimensional details.
Part#: LC3051 | Created: June 18, 2025
ClimateMaster
7300 SW 44th St
Oklahoma City, OK 73179
Phone: 800.299.9747
www.climatemaster.com
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact Climate Master's Customer Service Department at 800-299-9747 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at www.climatemaster.com.