Installation Overview
This guide provides essential steps for installing the HUUM UKU Glass/Mirror control panel. Ensure proper preparation and follow all instructions carefully for safe and effective operation of your sauna heater.
Key Specifications:
- Model: UKU Glass/Mirror control panel
- Compatibility: Electrical heaters up to 18 kW
- Power Options: 400 V 3N; 230 V 1N
Installation Steps
- Prepare the wall by creating a recess of 65 x 105 mm.
- Remove the protective film and detach the glass panel (attached with magnets).
- Connect the wires according to the numbering. Refer to the main UKU manual for detailed wiring information.
- Secure the control panel to the wall using appropriate fasteners for your wall material.
- Carefully attach the glass panel back onto the control panel housing.
- Reinstall the control knob.
Important Safety Notes
Electrical Hazard Warning: If the installation wall contains conductive materials (e.g., metal insulation) that could contact the wire screws on the back of the control panel, cover the screw heads with insulating tape to prevent short circuits.
Further Information
For the latest updates and comprehensive documentation, please visit the official HUUM website.