Instruction Manual for EPH CONTROLS models including: A17 1 Zone Timeswitch, A17, 1 Zone Timeswitch, Timeswitch
EPH CONTROLS A17 (02) PDF MANUAL Manual-Hub.com
File Info : application/pdf, 2 Pages, 1.10MB
DocumentDocumentA17 - 1 Zone Timeswitch Page 1 of 2 Installation Instructions For use in normal environments. CAUTION! Installation and connection should only be carried out by a qualified person and in accordance with national wiring regulations. Before commencing any work on the electrical connections, you must first disconnect the timeswitch from the mains. None of the 230V connections must be live until the installation has been completed and the housing is closed. Only qualified electricians or authorised service staff are permitted to open the timeswitch. Disconnect from mains supply in the event of any damage to any buttons. There are parts that carry mains voltage behind the cover. The timeswitch must not be left unsupervised when open. (Prevent non specialists and especially children from gaining access to it.) If the timeswitch is used in a way not specified by the manufacturer, its safety may be impaired. Prior to setting the timeswitch, it is neccessary to complete all required settings described in this section. Never remove this product from the electrical baseplate. Do not use sharp tools to push any button. Important: Keep this document This timeswitch is designed to provide ON/OFF control for 1 zone, with the value added application of in built frost protection. This timeswitch can be mounted in the following ways: 1. Directly wall mounted 2. Mounted to a recessed conduit box 1 2 Type 1C EN60730 IP20 EN60529 99 140 55 131 °C °F 0 32 5-95%RH 3 4 5 6 EPH Controls Ireland sales@ephcontrols.com www.ephcontrols.com EPH Controls UK sales@ephcontrols.co.uk www.ephcontrols.co.uk https://manual-hub.com/ 20180528_A17_InsIns_JW A17 - 1 Zone Timeswitch Page 2 of 2 Installation Instructions For use in normal environments. Contents 1. Factory default settings 2. Specifications & wiring 1. Factory default settings Contacts: Program: Backlight: Keypad: Clock type: Day-Light Saving Volt free contact 5/2D On Unlocked 24 Hr Clock 2. Specifications & wiring Power Supply: Ambient Temp: Contact Rating: Program Memory backup: Battery: Backlight: IP rating: Backplate: Pollution degree: Rated Impulse Voltage: Automatic Action: Software: Ball Pressure Test Temperature: 230 Vac, 50-60 Hz, 8 VA 0~35°C 250 Vac 3(1)A 3 months 3Vdc CR2032 Blue IP20 British System Standard 2 2,500V as per EN 60730 Type 1.C Class A 70°C COM OFF ON 200-240Vac 50Hz-60Hz CONTACT RATING: 250Vac~/3(1)A If mains voltage output is required, terminals L & 1 must be electrically linked. The cable link is provided with this timeswitch. EPH Controls Ireland sales@ephcontrols.com www.ephcontrols.com EPH Controls UK sales@ephcontrols.co.uk www.ephcontrols.co.uk https://manual-hub.com/ 20180528_A17_InsIns_JW