Schneider Electric Homeline Load Centers
Indoor, 1Ø, Main Lugs and Main Circuit Breaker
Class 1170 / Refer to Catalog 1100CT0501
Table 1.41 Homeline Load Center Accessories (cont'd.)
Service Entrance Barriers | Description | Cat. No. | Schedule |
For use on "S2" and "S3" Series NEMA 3R QOM2 load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150-225 A) with a Homeline 2P (15-125 A) branch circuit breaker. | HOMRBGK2C | DE3D | |
QO/Homeline 1Ø 100-125 A QOM1 convertible main load centers | PKSB1LA | DE3A | |
QO/Homeline 1Ø 150-225 A QOM2 convertible main load centers | PKSB1HA | DE3A | |
Homeline back-fed main breaker applications | PKSB1HOMBF | DE3A |
Surge Protective Devices
Table 1.42: Load Center and CSED Surge Protection Devices
Description | Cat. No. | Description | Surge Current per Phase [kA] | Schedule |
Surge Protective Device | QO2175SB | QO Surgebreaker | 22.5 | DE1B |
HOM2175SB | Homeline Surgebreaker 120/240 V, 1-phase, 3-wire | 22.5 | DE1B | |
SDSA1175 | 200 kA Surgebreaker 120/240 V, 1-phase, 3-wire | 36 | DE1B | |
SDSA3650 | 600Y/347 V, 3-phase, 4-wire | 40 | DE1B | |
Surge Protective Devices | QO250PSPD | Plug on Neutral QO™ Surgebreaker | 50 kA | DE1B |
HOM250PSPD | Plug on Neutral Homeline™ Surgebreaker | 50 kA | DE1B | |
HEPD50 | 50 kA Home Electronic Protective Device | 50 kA | DE1B | |
HEPD80 | 80 kA Home Electronic Protective Device | 80 kA | DE3A | |
Surge Protective Device Mounting Kits | QOSAMK | Mounting bracket for SDSA1175 | — | DE1B |
HEPD80MKF | Flush Mount Kit for HEPD80 | — | DE1B |
Table 1.43: Convertible Main Load Centers (Accepts Only HOM Plug-On Circuit Breakers)
Mains Rating | Spaces | Max. Single Pole Circuits [1] | Max. Tandem Circuit Breakers | Load Center Box, Interior and Cover [2] | Main Wire Size AWG/kcmil | Equipment Ground Bar Kit (Order Separately) | Bus. No. [3] | ||
Al | Cu | ||||||||
Main Lugs – 10 kA Short Circuit Current Rating Order HOM Circuit Breakers (See Homeline™ Circuit Breakers, page 1-22) Factory-installed Fixed Main Lugs | |||||||||
70 A | 10 | 12 | 6 | HOM24L70F/S [4] [5] | 12-3 | 14-4 | PK3GTA1 | 2 | |
100 A | 16 | 24 | 12 | HOM612L100F/S [4] [6] | 12-3/0 | 14-2/0 | PK7GTA | 4 | |
125 A | 24 | 32 | 16 | HOM48L125GC | PK7GTA included | 21 | |||
Convertible Mains – Factory-installed Main Lugs | |||||||||
QOM1 Main Frame Size – Convertible to Main Circuit Breaker (See 103W-120/240 Vac-UL Listed, page 1-21) | |||||||||
125 A | 8 | 16 | 8 | HOM816L125PC | 12-2/0 | 6-1 | PK9GTA | 6 | |
12 | 24 | 12 | HOM1224L125PC | 12-2/0 | 6-1 | PK15GTA | 6 | ||
16 | 32 | 16 | HOM1632L125PC | 12-2/0 | 6-1/0 | PK15GTA | 8 |
[1] Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
[2] C at end of catalog number indicates combination flush/surface cover included with device.
[3] See Indoor Knockout Information and Enclosure Dimensions, page 1-25
[4] F/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door.
[5] HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire.
[6] 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker.