Ruud Endeavor® Line Achiever® Series iM Air Conditioners
Model: RA14AY
Cooling Efficiencies: Up to 15.2 SEER2 / 12 EER2
Nominal Sizes: 1.5 to 5 Tons [5.28 to 17.6 kW]
Cooling Capacities: 17.1 to 55.5 kBTU [5.0 to 16.3 kW]
Refrigerant Type: R-454B
Certifications: ISO 9001:2015, AHRI Certified, ENERGY STAR®, UL Listed
A front view of a Ruud Endeavor® Line Achiever® Series iM Air Conditioner unit. It is a rectangular outdoor unit with a grey metal grille on the front and sides, a dark grey top with a fan visible, and a Ruud logo at the top center.
Features and Benefits
- 7mm Condenser Copper Coil: Requires less refrigerant, allowing for a smaller and lighter footprint while enhancing reliability.
- Swept Wing Fan Technology: Features quieter operation and improved unit acoustics.
- PlusOne® Triple Service Access: 15 in. wide, industry-leading corner service access with two fastener, removable corner and individual louver panels, making repairs easier and faster.
- Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78% lower GWP than previous-generation refrigerants, with only minimal changes to system installation. This represents a step toward reducing greenhouse gas emissions while delivering energy-efficient comfort.
- PlusOne® Refrigerant Detection System™: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration. It is compatible with any 24V thermostat application and provides system protection by automatically pausing outdoor unit operation if excess refrigerant is detected.
Model Number Identification
The model number structure for Ruud Air Conditioners (RA14AY) is as follows:
R - Ruud, A - Air Conditioners, 14 - SEER2 Rating (13.8/14.3), Y - Refrigerant (R-454B), followed by capacity, series, voltage, type, controls, and option codes.
Available Models
Model Number | Description |
---|---|
RA14AY18AJ1NA | Endeavor® Line Achiever® Series 1 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY18AJ1NALHP | Endeavor® Line Achiever® Series 1 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY24AJ1NA | Endeavor® Line Achiever® Series 2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY24AJ1NALHP | Endeavor® Line Achiever® Series 2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY24BJ1NA | Endeavor® Line Achiever® Series 2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY24BJ1NALHP | Endeavor® Line Achiever® Series 2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY30AJ1NA | Endeavor® Line Achiever® Series 2 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY30AJ1NALHP | Endeavor® Line Achiever® Series 2 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY36AJ1NA | Endeavor® Line Achiever® Series 3 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY36AJ1NALHP | Endeavor® Line Achiever® Series 3 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY36AC1NA | Endeavor® Line Achiever® Series 3 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/3/60 |
RA14AY36AD1NA | Endeavor® Line Achiever® Series 3 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-460/3/60 |
RA14AY42AJ1NA | Endeavor® Line Achiever® Series 3 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY42AJ1NALHP | Endeavor® Line Achiever® Series 3 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY42AC1NA | Endeavor® Line Achiever® Series 3 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/3/60 |
RA14AY42AD1NA | Endeavor® Line Achiever® Series 3 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-460/3/60 |
RA14AY48AJ1NA | Endeavor® Line Achiever® Series 4 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY48AJ1NALHP | Endeavor® Line Achiever® Series 4 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY48AC1NA | Endeavor® Line Achiever® Series 4 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner -208/230/3/60 |
RA14AY48AD1NA | Endeavor® Line Achiever® Series 4 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-460/3/60 |
RA14AY60AJ1NA | Endeavor® Line Achiever® Series 5 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY60AJ1NALHP | Endeavor® Line Achiever® Series 5 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY60AC1NA | Endeavor® Line Achiever® Series 5 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/3/60 |
RA14AY60AD1NA | Endeavor® Line Achiever® Series 5 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-460/3/60 |
Standard Equipment
- R-454B Refrigerant
- Scroll Compressor
- Field Installed Filter Drier
- Front Seating Service Valves
- Internal Pressure Relief Valve
- Internal Thermal Overload
- Long Line capability
- Low Ambient capability with Kit
- 3-4-5 Expanded Valve Space
- Composite Basepan
- 2 Screw Control Box Access
- 15" Access to Internal Components
- Quick release louver panel design
- No fasteners to remove along bottom
- Optimized Venturi Airflow
- Powder coated paint
- Rust resistant screws
- QR code
- External gauge ports
- Service trays
General Data and Electrical Data
General Data
Model No. | Nominal Tonnage | Valve Connections (Liquid Line O.D. - in.) | Valve Connections (Suction Line O.D. - in.) | Refrigerant R-454B furnished oz. | Compressor Type | Outdoor Coil (Net face area - Outer Coil) | Outdoor Coil (Net face area - Inner Coil) | Outdoor Coil (Tube diameter - in.) | Outdoor Coil (Number of rows) | Outdoor Coil (Fins per inch) | Outdoor Fan (Diameter - in.) | Outdoor Fan (Number of blades) | Outdoor Fan (Motor hp) | Outdoor Fan (CFM) | Outdoor Fan (RPM) | Outdoor Fan (Watts) | Shipping weight - lbs. | Operating weight - lbs. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RA14AY18 | 1.5 | 3/8 | 3/4 | 97 | Scroll | 10.9 | -- | 0.276 | 1 | 24 | 20 | 2 | 1/7 | 1765 | 1075 | 154 | 148 | 141 |
RA14AY24A | 2.0 | 3/8 | 3/4 | 112 | Scroll | 13.3 | -- | 0.276 | 1 | 24 | 24 | 3 | 1/6 | 3146 | 825 | 197 | 170 | 163 |
RA14AY24B | 2.0 | 3/8 | 3/4 | 82 | Scroll | 13.3 | -- | 0.276 | 1 | 24 | 24 | 3 | 1/6 | 3439 | 825 | 197 | 170 | 163 |
RA14AY30 | 2.5 | 3/8 | 3/4 | 112 | Scroll | 13.3 | -- | 0.276 | 1 | 24 | 24 | 3 | 1/6 | 3146 | 825 | 197 | 170 | 163 |
RA14AY36 | 3.0 | 3/8 | 3/4 | 116 | Scroll | 13.3 | 12.9 | 0.276 | 2 | 24 | 24 | 3 | 1/5 | 2760 | 825 | 188 | 193 | 186 |
RA14AY42 | 3.5 | 3/8 | 7/8 | 142 | Scroll | 19.5 | 18.8 | 0.276 | 2 | 24 | 24 | 3 | 1/5 | 3431 | 850 | 225 | 259 | 252 |
RA14AY48 | 4.0 | 3/8 | 7/8 | 142 | Scroll | 19.5 | 18.8 | 0.276 | 2 | 24 | 24 | 3 | 1/5 | 3606 | 850 | 251 | 250 | 243 |
RA14AY60 | 5.0 | 3/8 | 7/8 | 192 | Scroll | 27.9 | 27.1 | 0.276 | 2 | 24 | 26 | 3 | 1/5 | 4169 | 850 | 245 | 273 | 266 |
Electrical Data
Line Voltage Data (Volts-Phase-Hz): 208/230-1-60
Model | Max Overcurrent Protection (amps) | Min Circuit Ampacity | Compressor Rated Load Amps | Compressor Locked Rotor Amps | Condenser Fan Motor Full Load Amps | Condenser Fan Motor Locked Rotor Amps |
---|---|---|---|---|---|---|
RA14AY18 | 15 | 12 | 8.3 | 45 | 0.75 | 1.50 |
RA14AY24A | 25 | 17 | 12.7 | 67 | 0.8 | 1.7 |
RA14AY24B | 20 | 14 | 10 | 60 | 0.8 | 1.7 |
RA14AY30 | 25 | 17 | 12.7 | 67 | 0.8 | 1.7 |
RA14AY36 | 30 | 18 | 13.5 | 75 | 0.8 | 1.7 |
RA14AY42 | 30 | 20 | 14.7 | 109 | 1.0 | 2.6 |
RA14AY48 | 50 | 30 | 22.4 | 126 | 1.0 | 2.6 |
RA14AY60 | 50 | 31 | 23.7 | 157 | 1.0 | 2.6 |
Line Voltage Data (Volts-Phase-Hz): 208/230-3-60
Model | Max Overcurrent Protection (amps) | Min Circuit Ampacity | Compressor Rated Load Amps | Compressor Locked Rotor Amps | Condenser Fan Motor Full Load Amps | Condenser Fan Motor Locked Rotor Amps |
---|---|---|---|---|---|---|
RA14AY36 | -- | -- | -- | -- | -- | -- |
RA14AY42 | 20.0 | 14.4 | 9.0 | 70.0 | 0.8 | 1.7 |
RA14AY48 | 25.0 | 20.0 | 12.2 | 102.8 | 1.0 | 2.6 |
RA14AY60 | 35.0 | 22.0 | 16.0 | 156.4 | 1.0 | 2.6 |
Line Voltage Data (Volts-Phase-Hz): 460-3-60
Model | Max Overcurrent Protection (amps) | Min Circuit Ampacity | Compressor Rated Load Amps | Compressor Locked Rotor Amps | Condenser Fan Motor Full Load Amps | Condenser Fan Motor Locked Rotor Amps |
---|---|---|---|---|---|---|
RA14AY36 | -- | -- | -- | -- | -- | -- |
RA14AY42 | 20.0 | 12.0 | 9.0 | 70.0 | 0.50 | 0.90 |
RA14AY48 | 15.0 | 9.0 | 5.8 | 50.0 | 0.80 | 1.40 |
RA14AY60 | 15.0 | 10.0 | 7.1 | 69.0 | 0.80 | 1.40 |
Accessories
Model No. | Compressor Crankcase Heater (with temp. thermostat) | Compressor Crankcase Heater (without temp. thermostat) | Low Ambient Control | Compressor Sound Cover | Compressor Hard Start Kit | Compressor Time Delay | Low Pressure Control | High Pressure Control | Liquid Line Solenoid Valve (24 VAC, 50/60 Hz) | Liquid Line Solenoid Coil (24 VAC, 50/60 Hz) | Liquid Line Solenoid Valve (120/240 VAC, 50/60 Hz) | Liquid Line Solenoid Coil (120/240 VAC, 50/60 Hz) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
RA14AY18 | 44-101884-08 | 44-17402-44 | RXAD-A08 | 68-23427-26 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | 200RD2T3TVLC | 61-AMG120/240V |
RA14AY24 | 44-101884-08 | 44-17402-44 | RXAD-A08 | 68-23427-26 | SK-A1 | RXMD-B02 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | 200RD2T3TVLC | 61-AMG120/240V |
RA14AY30 | 44-101884-08 | 44-17402-44 | RXAD-A08 | 68-23427-26 | SK-A1 | RXMD-B03 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | 200RD2T3TVLC | 61-AMG120/240V |
RA14AY36 | 44-101884-08 | 44-17402-44 | RXAD-A08 | 68-23427-26 | SK-A1 | RXMD-B04 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | 200RD2T3TVLC | 61-AMG120/240V |
RA14AY42 | 208/230V: 44-101884-08 460V: 44-101884-09 | 208/230V: 44-17402-44 460V: 442040 | RXAD-A08 | 68-23427-26 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | 200RD2T3TVLC | 61-AMG120/240V |
RA14AY48 | 208/230V: 44-103663-161 460V: 44-101884-061 | 208/230V: 44-17402-45 460V: 44-17402-46 | RXAD-A08 | 68-23427-25 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | 200RD2T3TVLC | 61-AMG120/240V |
RA14AY60 | 208/230V: 44-103663-162 460V: 44-101884-062 | 208/230V: 44-17402-45 460V: 44-17402-46 | RXAD-A08 | 68-23427-25 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | 200RD2T3TVLC | 61-AMG120/240V |
Maximum System Charge Values
Model No. | Charge Limit Without Crankcase (Copeland) | Charge Limit Without Crankcase (LG) |
---|---|---|
RA14AY18 | 9.6 lbs [4.4kg] | 8.4 lbs [3.8 kg] |
RA14AY24, RA14AY30 | 12 lbs [5.4kg] | 11.9 lbs [5.4 kg] |
RA14AY36, RA14AY42, RA14AY48, RA14AY60 | 12 lbs [5.4kg] | 11.9 lbs [5.4 kg] |
Weighted Sound Power Level (dBA)
Unit Size - Voltage, Series | Standard Rating (dBA) | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | 8000 Hz |
---|---|---|---|---|---|---|---|---|
RA14AY18 | 70 | 47 | 55 | 61 | 60 | 58 | 53 | 47 |
RA14AY24 | 71 | 47 | 62 | 63 | 59 | 57 | 56 | 47 |
RA14AY30 | 71 | 47 | 62 | 63 | 59 | 57 | 56 | 47 |
RA14AY36 | 71 | 46 | 58 | 64 | 59 | 57 | 52 | 48 |
RA14AY42 | 73 | 47 | 55 | 64 | 62 | 59 | 55 | 48 |
RA14AY48 | 74 | 45 | 56 | 64 | 63 | 61 | 57 | 51 |
RA14AY60 | 76 | 43 | 60 | 67 | 66 | 63 | 59 | 53 |
Unit Dimensions
Dimensions are provided in inches and millimeters [mm].
Model No. | OPERATING | SHIPPING | ||||
---|---|---|---|---|---|---|
H (Height) | L (Length) | W (Width) | H (Height) | L (Length) | W (Width) | |
INCHES (mm) | INCHES (mm) | INCHES (mm) | INCHES (mm) | INCHES (mm) | INCHES (mm) | |
RA14AY18 | 25.00 (635) | 29.75 (756) | 29.75 (756) | 26.50 (673) | 32.38 (822) | 32.38 (822) |
RA14AY24 | 25.00 (635) | 33.75 (857) | 33.75 (857) | 26.50 (673) | 36.38 (924) | 36.38 (924) |
RA14AY30 | 25.00 (635) | 33.75 (857) | 33.75 (857) | 26.50 (673) | 36.38 (924) | 36.38 (924) |
RA14AY36 | 25.00 (635) | 33.75 (857) | 33.75 (857) | 26.50 (673) | 36.38 (924) | 36.38 (924) |
RA14AY42 | 35.00 (889) | 33.75 (857) | 33.75 (857) | 36.50 (927) | 36.38 (924) | 36.38 (924) |
RA14AY48 | 35.00 (889) | 33.75 (857) | 33.75 (857) | 36.50 (927) | 36.38 (924) | 36.38 (924) |
RA14AY60 | 45.00 (1143) | 35.75 (908) | 35.75 (908) | 46.50 (1181) | 38.38 (975) | 38.38 (975) |
Clearance Requirements:
- Allow 60" [1524 mm] of clearance around the unit.
- Air inlet louvers require a minimum of 6" [152 mm] of clearance on all sides; 12" [305 mm] is recommended.
- Service panels/inlet connections/high & low voltage access require 24" [610 mm] of clearance.
Clearances
Diagrams illustrate required clearances for unit installation. Numbers in parentheses indicate millimeters (mm).
Configuration 1 (Single Unit):
- Service Clearance: 24" (609.6)
- Side Clearance: 6" (152.4)
- Front/Rear Clearance: 12" (304.8)
Configuration 2 (Multiple Units or Alcove):
- Service Clearance: 24" (609.6)
- Recommended Clearance: 24" (609.6)
- Minimum Clearance: 6" (152.4)
- Side Clearance (from wall): 18" (457.2)
- Front/Rear Clearance: 12" (304.8)
Important Note: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure adequate ventilation to prevent re-circulation of discharge air.
Refrigerant Line Size Information
Tables provide allowable liquid and suction line sizes based on unit size and equivalent length (feet and meters), along with maximum vertical rise and capacity multipliers for 14.3 SEER2 AC R-454B.
(Refer to original document for detailed tables of refrigerant line sizing.)
Performance Data @ AHRI Standard Conditions – Cooling
Outdoor Unit | Indoor Coil | Total Capacity BTU/H [KW] | Net Sensible BTU/H [KW] | Net Latent BTU/H [KW] | SEER2 | EER2 | Indoor CFM [L/s] |
---|---|---|---|---|---|---|---|
RA14AY18AJ1 | RCFY2421HTANM | 17,100 [5.0] | 13,100 [3.8] | 4,000 [1.2] | 14.3 | 11.7 | 600 [283.2] |
RA14AY24AJ1 | RCFY3621HTAAM | 22,800 [6.7] | 17,500 [5.1] | 5,300 [1.6] | 14.3 | 11.7 | 735 [346.9] |
RA14AY24BJ1 | RCFY2421HTANM | 22,800 [6.7] | 17,500 [5.1] | 5,300 [1.6] | 14.3 | 11.7 | 750 [354.0] |
RA14AY30AJ1 | RCFY3621HTAAM | 28,600 [8.4] | 21,800 [6.4] | 6,800 [2.0] | 14.3 | 11.7 | 910 [429.5] |
RA14AY36AJ1 | RCFY3621HTAAM | 33,600 [9.8] | 25,200 [7.4] | 8,400 [2.5] | 14.3 | 11.7 | 1,030 [486.1] |
RA14AY42AJ1 | RCFY4221HTAAM | 40,000 [11.7] | 29,500 [8.6] | 9,000 [2.6] | 14.3 | 11.7 | 1,300 [613.5] |
RA14AY48AJ1 | RCFY4821HTAAM | 45,500 [13.3] | 34,500 [10.1] | 10,500 [3.1] | 13.8 | 11.7 | 1,425 [672.5] |
RA14AY60AJ1 | RCFY6024HTANM | 56,000 [16.4] | 42,900 [12.6] | 13,100 [3.8] | 13.8 | 11.7 | 1,575 [743.3] |
RA14AY36AC1 | RCFY3621HTAAM | 33,600 [9.8] | 25,200 [7.4] | 8,400 [2.5] | 14.3 | 11.7 | 1,030 [486.1] |
RA14AY42AC1 | RCFY4221HTAAM | 40,000 [11.7] | 29,500 [8.6] | 9,000 [2.6] | 14.3 | 11.7 | 1,300 [613.5] |
RA14AY48AC1 | RCFY4821HTAAM | 45,500 [13.3] | 34,500 [10.1] | 10,500 [3.1] | 13.8 | 11.7 | 1,425 [672.5] |
RA14AY60AC1 | RCFY6024HTANM | 56,000 [16.4] | 42,900 [12.6] | 13,100 [3.8] | 13.8 | 11.7 | 1,575 [743.3] |
RA14AY36AD1 | RCFY3621HTAAM | 33,600 [9.8] | 25,200 [7.4] | 8,400 [2.5] | 14.3 | 11.7 | 1,030 [486.1] |
RA14AY42AD1 | RCFY4221HTAAM | 40,000 [11.7] | 29,500 [8.6] | 9,000 [2.6] | 14.3 | 11.7 | 1,300 [613.5] |
RA14AY48AD1 | RCFY4821HTAAM | 45,500 [13.3] | 34,500 [10.1] | 10,500 [3.1] | 13.8 | 11.7 | 1,425 [672.5] |
RA14AY60AD1 | RCFY6024HTANM | 56,000 [16.4] | 42,900 [12.6] | 13,100 [3.8] | 13.8 | 11.7 | 1,575 [743.3] |
Note: Data includes DTC ratings for reference. For official ratings and system match-ups, visit the AHRI website: www.ahridirectory.org.
General Terms of Limited Warranty
Ruud will furnish a replacement for any part of this product that fails in normal use and service within the applicable period, in accordance with the terms of the limited warranty.
Conditional Parts (Registration Required): Ten (10) Years.
For complete details of Limited and Conditional Warranties, contact your local contractor or the Manufacturer for a product warranty certificate.
Before proceeding with installation, refer to installation instructions packaged with each model and comply with all Federal, State, Provincial, and Local codes, regulations, and practices.
©2024 Rheem Manufacturing Company. Ruud trademarks owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.
Contact Information:
- 5600 Old Greenwood Road, Fort Smith, Arkansas 72908, www.ruud.com
- 125 Edgeware Road, Unit 1, Brampton, Ontario L6Y 0P5, ruud-canada.ca