Ruud Endeavor® Line Achiever® Series iM Air Conditioners
Product Overview
The Ruud Endeavor® Line Achiever® Series iM Air Conditioners (Model RA14AY) offer efficient and reliable cooling solutions. These units are designed with advanced features for optimal performance and sustainability.
Key Features:
- 7mm Condenser Copper Coil: Requires less refrigerant, resulting in a smaller, lighter footprint and enhanced reliability.
- Swept Wing Fan Technology¹: Provides quieter operation and improved unit acoustics.
- PlusOne® Triple Service Access: Features industry-leading corner service access with two-fastener, removable corner and individual louver panels for easier and faster repairs.
- Designing for Sustainability with Low GWP: Utilizes R-454B refrigerant, which has a 78% lower GWP compared to previous-generation refrigerants, contributing to reduced greenhouse gas emissions.
- PlusOne® Refrigerant Detection System™³: An integrated system that automatically pauses outdoor unit operation if excess refrigerant is detected, enhancing safety and system protection.
¹Does not apply to 1.5- and 2-ton models.
²When comparing the GWP of R-454B to R-410A refrigerant.
³Factory or field installed in the furnace coil or air handler and is applicable to the complete heating and cooling system featuring Low GWP Refrigerant (A2L).
Model Identification
The model number RA14AY indicates the following:
- R: Brand (Ruud)
- A: Product Category (Air Conditioner)
- 14: SEER2 Rating (13.8/14.3 SEER2)
- A: Region (All)
- Y: Refrigerant (R-454B)
- 18, 24, 30, 36, 42, 48, 60: Capacity in thousands of BTU/HR (e.g., 18 = 18,000 BTU/HR [5.28 kW])
- A: Major Series (1st Design)
- J: Voltage (1-phase, 208-230/60)
- 1: Type (Single Stage)
- N: Controls (Non-Communicating)
- A: Minor Series (1st Design)
- LHP: Option Code (With High/Low Pressure)
Available Models:
Model Number | Description |
---|---|
RA14AY18AJ1NA | Endeavor® Line Achiever® Series 1 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY18AJ1NALHP | Endeavor® Line Achiever® Series 1 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY24AJ1NA | Endeavor® Line Achiever® Series 2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY24AJ1NALHP | Endeavor® Line Achiever® Series 2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY30AJ1NA | Endeavor® Line Achiever® Series 2 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY30AJ1NALHP | Endeavor® Line Achiever® Series 2 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY36AJ1NA | Endeavor® Line Achiever® Series 3 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY36AJ1NALHP | Endeavor® Line Achiever® Series 3 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY42AJ1NA | Endeavor® Line Achiever® Series 3 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY42AJ1NALHP | Endeavor® Line Achiever® Series 3 1/2 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY48AJ1NA | Endeavor® Line Achiever® Series 4 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY48AJ1NALHP | Endeavor® Line Achiever® Series 4 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
RA14AY60AJ1NA | Endeavor® Line Achiever® Series 5 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner-208/230/1/60 |
RA14AY60AJ1NALHP | Endeavor® Line Achiever® Series 5 ton 13.8/14.3 SEER2 Single-Stage Air Conditioner w/ High/Low Pressure-208/230/1/60 |
General Data and Electrical Data
Model | Nominal Tonnage | Liquid Line O.D. (in.) | Suction Line O.D. (in.) | Refrigerant R-454B (oz.) | Max Overcurrent Protection (amps) | Min Circuit Ampacity | Compressor Rated Load Amps | Compressor Locked Rotor Amps | Condenser Fan Motor Full Load Amps | Condenser Fan Motor Locked Rotor Amps |
---|---|---|---|---|---|---|---|---|---|---|
RA14AY18 | 1.5 | 3/8 | 3/4 | 97 | 15 | 12 | 8 | 47 | 0.8 | 1.5 |
RA14AY24 | 2.0 | 3/8 | 3/4 | 112 | 25 | 17 | 13 | 78 | 0.8 | 1.5 |
RA14AY30 | 2.5 | 3/8 | 3/4 | 112 | 25 | 17 | 13 | 78 | 0.8 | 1.5 |
RA14AY36 | 3.0 | 3/8 | 3/4 | 116 | 30 | 18 | 14 | 75 | 0.8 | 1.7 |
RA14AY42 | 3.5 | 3/8 | 7/8 | 142 | 30 | 20 | 15 | 109 | 1.0 | 2.6 |
RA14AY48 | 4.0 | 3/8 | 7/8 | 142 | 50 | 30 | 22 | 126 | 1.0 | 2.6 |
RA14AY60 | 5.0 | 3/8 | 7/8 | 192 | 50 | 31 | 24 | 157 | 1.0 | 2.6 |
Note: Refrigerant charge is sufficient for 15 ft. of refrigerant lines. For longer line set requirements, refer to installation instructions.
Accessories
Model No. | Compressor Crankcase Heater (with temp. thermostat) | Compressor Crankcase Heater (without temp. thermostat) | Low Ambient Control | Compressor Sound Cover | Compressor Hard Start Kit | Compressor Time Delay | Low Pressure Control | High Pressure Control | Liquid Line Solenoid | Solenoid Valve (24 VAC, 50/60 Hz) | Solenoid Coil | Solenoid Valve (120/240 VAC, 50/60 Hz) | Solenoid Coil |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RA14AY18 | 44-101884-08 | 44-17402-44 | RXAD-A08 | 68-23427-26 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | |||
RA14AY24 | 44-101884-08 | 44-17402-44 | RXAD-A08 | 68-23427-26 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | |||
RA14AY30 | 44-101884-08 | 44-17402-44 | RXAD-A08 | 68-23427-26 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | |||
RA14AY36 | 44-101884-08 | 44-17402-44 | RXAD-A08 | 68-23427-26 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | |||
RA14AY42 | 44-103663-16* | 44-17402-45 | RXAD-A08 | 68-23427-25 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | 61-AMG120/240V | ||
RA14AY48 | 44-103663-16 | 44-17402-45 | RXAD-A08 | 68-23427-25 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | 61-AMG120/240V | ||
RA14AY60 | 44-103663-16** | 44-17402-45 | RXAD-A08 | 68-23427-25 | SK-A1 | RXMD-B01 | RXAC-A10 | RXAB-A08 | 200RD2T3TVLC | 61-AMG24V | 61-AMG120/240V |
*RA14AY42 models with LG come with 44-101884-08 factory-installed.
**RA14AY60 models come with 44-103663-16 factory-installed.
Weighted Sound Power Level (dBA)
Unit Size - Voltage, Series | Standard Rating (dBA) | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | 8000 Hz |
---|---|---|---|---|---|---|---|---|
RA14AY18 | 70 | 47 | 55 | 61 | 60 | 58 | 53 | 47 |
RA14AY24 | 71 | 47 | 62 | 63 | 59 | 57 | 56 | 47 |
RA14AY30 | 71 | 47 | 62 | 63 | 59 | 57 | 56 | 47 |
RA14AY36 | 71 | 46 | 58 | 64 | 59 | 57 | 52 | 48 |
RA14AY42 | 73 | 47 | 55 | 64 | 62 | 59 | 55 | 48 |
RA14AY48 | 74 | 45 | 56 | 64 | 63 | 61 | 57 | 51 |
RA14AY60 | 76 | 43 | 60 | 67 | 66 | 63 | 59 | 53 |
Note: Tested in accordance with AHRI Standard 270-08.
Unit Dimensions
Model No. | OPERATING (INCHES) | SHIPPING (INCHES) | ||||
---|---|---|---|---|---|---|
H (Height) | L (Length) | W (Width) | H (Height) | L (Length) | W (Width) | |
RA14AY18 | 25.00 | 29.75 | 29.75 | 26.50 | 32.38 | 32.38 |
RA14AY24 | 25.00 | 33.75 | 33.75 | 26.50 | 36.38 | 36.38 |
RA14AY30 | 25.00 | 33.75 | 33.75 | 26.50 | 36.38 | 36.38 |
RA14AY36 | 25.00 | 33.75 | 33.75 | 26.50 | 36.38 | 36.38 |
RA14AY42 | 35.00 | 33.75 | 33.75 | 36.50 | 36.38 | 36.38 |
RA14AY48 | 35.00 | 33.75 | 33.75 | 36.50 | 36.38 | 36.38 |
RA14AY60 | 45.00 | 35.75 | 35.75 | 46.50 | 38.38 | 38.38 |
Diagram: Unit Dimensions and Clearances
The diagram shows a rectangular outdoor unit with labels for Height (H), Length (L), and Width (W). Arrows indicate airflow discharge from the top and intake through the sides.
Clearance requirements:
- Allow 60" [1524 mm] of clearance around the unit.
- Air inlet louvers require a minimum of 6" [152 mm] of clearance on all sides, with 12" [305 mm] recommended.
- Service panels, inlet connections, and high/low voltage access require 24" [610 mm] of clearance.
Clearances
Proper clearances are essential for optimal performance and serviceability. The following diagrams illustrate recommended clearances from walls and other obstructions.
Diagram: Clearance Requirements
The diagrams show side views of an air conditioner unit next to a wall, illustrating required clearances for service and airflow. Dimensions are provided in inches and millimeters.
Configuration 1:
- 24" (609.6 mm) Service
- 6" (152.4 mm)
- 12" (304.8 mm)
- 6" (152.4 mm)
Configuration 2:
- 24" (609.6 mm) Service
- 24" (609.6 mm)
- 24" recommended, 6" minimum
- 24" (609.6 mm) Service
- 12" (304.8 mm)
- 24" (609.6 mm) Service
- 24" recommended, 6" minimum
Note: Numbers in () are in millimeters.
Important: Ensure adequate ventilation in alcoves, roof wells, or partially enclosed areas to prevent re-circulation of discharge air.
Refrigerant Line Size Information
This section provides guidelines for selecting appropriate refrigerant line sizes based on unit size, equivalent length, and vertical rise. The tables detail maximum allowable liquid and suction line sizes and corresponding capacity multipliers.
14.3 SEER2 AC R-454B
Unit Size | Allowable Liquid Line Size | Allowable Suction Line Size | Equivalent Length (Feet) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
0-25 | 26-50 | 51-75 | 76-100 | 101-125 | 126-150 | 151-175 | 176-200 | 201-225 | 226-250 | |||
1.5 Ton | 1/4" | 5/8" | 25/1 | 50/0.99 | 61/0.99 | 41/0.98 | 21/0.98 | 1/0.98 | 0/0.98 | 0/0.97 | 0/0.97 | |
5/16" | 5/8" | 25/1 | 50/0.99 | 75/0.99 | 100/0.98 | 98/0.98 | 93/0.98 | 87/0.98 | 82/0.98 | 78/0.97 | 75/0.97 | |
3/8" | 5/8" | 25/1 | 50/0.99 | 75/0.99 | 100/0.98 | 117/0.98 | 115/0.98 | 114/0.98 | 112/0.98 | 111/0.97 | 110/0.97 | |
1/4" | 3/4" | 25/1 | 50/1 | 75/1 | 100/0.99 | 98/0.99 | 93/0.99 | 87/0.99 | 82/0.99 | 78/0.99 | 75/0.98 | |
5/16" | 3/4" | 25/1 | 50/1 | 75/1 | 100/0.99 | 117/0.99 | 115/0.99 | 114/0.99 | 112/0.99 | 111/0.98 | 110/0.98 | |
3/8" | 3/4" | 25/1 | 50/1 | 75/1 | 100/0.99 | 117/0.99 | 115/0.99 | 114/0.99 | 112/0.99 | 111/0.98 | 110/0.98 | |
2 Ton | 1/4" | 5/8" | 25/0.99 | 50/0.98 | 61/1 | 41/0.99 | 21/0.99 | 1/0.99 | 0/0.99 | 0/0.99 | 0/0.98 | 0/0.97 |
5/16" | 5/8" | 25/1 | 50/0.99 | 75/0.98 | 88/0.98 | 79/0.98 | 70/0.97 | 62/0.96 | 53/0.97 | 46/0.96 | 40/0.95 | |
3/8" | 5/8" | 25/1 | 50/0.99 | 75/0.98 | 100/0.98 | 109/0.98 | 106/0.97 | 103/0.96 | 100/0.97 | 97/0.96 | 94/0.95 | |
1/4" | 3/4" | 25/1 | 50/1 | 75/0.98 | 100/0.97 | 101/0.98 | 96/0.96 | 92/0.94 | 87/0.93 | 83/0.92 | 78/0.93 | |
5/16" | 3/4" | 25/1 | 50/1 | 75/0.99 | 100/0.99 | 109/0.99 | 106/0.98 | 103/0.98 | 100/0.99 | 97/0.99 | 94/0.98 | |
3/8" | 3/4" | 25/1 | 50/1 | 75/0.99 | 100/0.99 | 109/0.99 | 106/0.98 | 103/0.98 | 100/0.99 | 97/0.99 | 94/0.98 | |
2.5 Ton | 5/16" | 5/8" | 25/0.99 | 50/0.98 | 61/0.98 | 56/0.98 | 43/0.96 | 30/0.94 | 17/0.93 | 6/0.92 | 0/0.93 | |
3/8" | 5/8" | 25/0.99 | 50/0.98 | 75/0.98 | 97/0.98 | 91/0.94 | 85/0.93 | 78/0.92 | 72/0.91 | 66/0.9 | 60/0.9 | |
5/16" | 3/4" | 25/1 | 50/0.99 | 75/0.99 | 69/0.98 | 56/0.98 | 43/0.99 | 30/0.98 | 17/0.98 | 6/0.97 | 0/0.97 | |
3/8" | 3/4" | 25/1 | 50/0.99 | 75/0.99 | 100/0.99 | 101/0.98 | 96/0.99 | 92/0.98 | 87/0.98 | 83/0.97 | 78/0.97 | |
3 Ton | 1/2" | 3/4" | 25/1 | 50/1 | 75/0.98 | 100/0.98 | 101/0.98 | 96/0.96 | 92/0.94 | 87/0.93 | 83/0.92 | 78/0.93 |
5/16" | 7/8" | 25/1 | 50/1 | 75/0.98 | 100/0.99 | 118/0.98 | 117/0.98 | 115/0.97 | 115/0.96 | 114/0.96 | 112/0.98 | |
3/8" | 7/8" | 25/1 | 50/1 | 75/0.98 | 100/0.99 | 118/0.99 | 117/0.98 | 115/0.98 | 115/0.99 | 114/0.99 | 112/0.99 | |
1/2" | 7/8" | 25/1 | 50/1 | 75/0.98 | 100/0.99 | 118/0.99 | 117/0.98 | 115/0.98 | 115/0.99 | 114/0.99 | 112/0.99 | |
3.5 Ton | 3/8" | 3/4" | 25/0.99 | 50/0.99 | 75/0.99 | 88/0.98 | 80/0.97 | 72/0.96 | 64/0.98 | 55/0.96 | 47/0.95 | 39/0.95 |
1/2" | 3/4" | 25/0.99 | 50/0.99 | 75/0.99 | 100/0.98 | 116/0.97 | 114/0.96 | 112/0.98 | 111/0.96 | 109/0.95 | 108/0.95 | |
3/8" | 7/8" | 25/1 | 50/0.99 | 75/0.99 | 88/0.99 | 80/0.98 | 72/0.99 | 64/0.99 | 55/0.98 | 47/0.98 | 39/0.98 | |
1/2" | 7/8" | 25/1 | 50/0.99 | 75/0.99 | 100/0.99 | 116/0.98 | 114/0.99 | 112/0.99 | 111/0.98 | 109/0.98 | 108/0.98 | |
4 Ton | 3/8" | 3/4" | 25/0.99 | 50/0.98 | 75/0.98 | 78/0.97 | 68/0.96 | 57/0.97 | 46/0.95 | 36/0.94 | 25/0.93 | 15/0.93 |
1/2" | 3/4" | 25/0.99 | 50/0.98 | 75/0.97 | 100/0.97 | 107/0.94 | 104/0.93 | 101/0.92 | 97/0.9 | 95/0.89 | 93/0.89 | |
3/8" | 7/8" | 25/1 | 50/0.99 | 75/0.99 | 78/0.98 | 68/0.99 | 57/0.98 | 46/0.98 | 36/0.98 | 25/0.97 | 15/0.97 | |
1/2" | 7/8" | 25/0.99 | 50/0.99 | 75/0.99 | 100/0.98 | 107/0.98 | 104/0.97 | 101/0.96 | 97/0.98 | 95/0.97 | 93/0.96 | |
5 Ton | 3/8" | 3/4" | 25/0.99 | 50/0.98 | 70/0.97 | 54/0.97 | 38/0.94 | 22/0.93 | 6/0.92 | 0/0.9 | 0/0.89 | 0/0.89 |
1/2" | 3/4" | 25/0.99 | 50/0.98 | 75/0.97 | 100/0.97 | 107/0.94 | 104/0.93 | 101/0.92 | 97/0.9 | 95/0.89 | 93/0.89 | |
3/8" | 7/8" | 25/0.99 | 50/0.99 | 70/0.98 | 54/0.98 | 38/0.98 | 22/0.97 | 6/0.96 | 0/0.98 | 0/0.97 | 0/0.96 | |
1/2" | 7/8" | 25/0.99 | 50/0.99 | 75/0.98 | 100/0.98 | 107/0.98 | 104/0.97 | 101/0.96 | 97/0.98 | 95/0.97 | 93/0.96 | |
3/8" | 1-1/8" | 25/1 | 50/1 | 70/1 | 54/0.99 | 38/0.99 | 22/0.99 | 6/0.99 | 0/0.99 | 0/0.99 | 0/0.98 | |
1/2" | 1-1/8" | 25/1 | 50/1 | 75/1 | 100/0.99 | 107/0.99 | 104/0.99 | 101/0.99 | 97/0.99 | 95/0.99 | 93/0.98 |
Notes: 1) Maximum Equivalent Line Length may not exceed 250'. 2) Maximum Actual Line Length may not exceed 200'. 3) Light Grey shaded areas indicate long line conditions requiring accessories. 4) Do not use suction line traps.
Performance Data @ AHRI Standard Conditions – Cooling
Outdoor Unit | Indoor Coil | Total Capacity BTU/H [KW] | Net Sensible BTU/H [KW] | Net Latent BTU/H [KW] | SEER2 | EER2 | Indoor CFM [L/s] |
---|---|---|---|---|---|---|---|
RA14AY18AJ1 | RCFY2421HTAN | 17,100 [5.0] | 13,100 [3.8] | 4,000 [1.2] | 14.3 | 11.7 | 600 [283.2] |
RA14AY24AJ1 | RCFY3621HTAA | 22,800 [6.7] | 17,500 [5.1] | 5,300 [1.6] | 14.3 | 11.7 | 735 [346.9] |
RA14AY30AJ1 | RCFY3621HTAA | 28,600 [8.4] | 21,800 [6.4] | 6,800 [2.0] | 14.3 | 11.7 | 910 [429.5] |
RA14AY36AJ1 | RCFY3621HTAA | 33,600 [9.8] | 25,200 [7.4] | 8,400 [2.5] | 14.3 | 11.7 | 1,030 [486.1] |
RA14AY42AJ1 | RCFY4221HTAA | 40,000 [11.7] | 29,500 [8.6] | 9,000 [2.6] | 14.3 | 11.7 | 1,300 [613.5] |
RA14AY48AJ1 | RCFY4821HTAA | 45,500 [13.3] | 34,500 [10.1] | 10,500 [3.1] | 13.8 | 11.7 | 1,425 [672.5] |
RA14AY60AJ1 | RCFY6024HTAN | 56,000 [16.4] | 42,900 [12.6] | 13,100 [3.8] | 13.8 | 11.7 | 1,575 [743.3] |
Note: Data includes DTC ratings. For full AHRI listings and system match-ups, visit www.ahridirectory.org.
General Terms of Limited Warranty
Ruud provides a replacement for any part of this product that fails under normal use and service within the applicable period, according to the terms of the limited warranty.
Conditional Parts (Registration Required): Ten (10) Years
*For complete details of Limited and Conditional Warranties, contact your local contractor or the Manufacturer.
Before proceeding with installation, refer to installation instructions packaged with each model and comply with all Federal, State, Provincial, and Local codes, regulations, and practices.
©2024 Rheem Manufacturing Company. Ruud trademarks owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.
Contact Information:
Ruud Manufacturing Company
5600 Old Greenwood Road
Fort Smith, Arkansas 72908
www.ruud.com
Rheem Canada Ltd.
125 Edgeware Road, Unit 1
Brampton, Ontario L6Y OP5
ruud-canada.ca
File Info : application/pdf, 12 Pages, 643.54KB
DocumentDocumentReferences
Reliable Water Heaters, Tankless Water Heaters, and HVAC Systems for your home and business in Canada. - Ruud-Canada.ca
Homepage | ENERGY STAR
Reliable Water Heaters, Tankless Water Heaters, and HVAC Systems - Ruud
Related Documents
![]() |
Ruud Endeavor® Line Achiever® Series iM Air Conditioners RA14AY Product Overview Detailed specifications, features, performance data, and installation clearances for the Ruud Endeavor® Line Achiever® Series iM Air Conditioners, model RA14AY, featuring R-454B refrigerant. |
![]() |
Ruud Endeavor Line Achiever Plus Series iM Air Conditioners: RA15AZ Technical Specifications and Features Explore the Ruud Endeavor Line Achiever Plus Series iM Air Conditioners (RA15AZ models) with 15.2 SEER2 efficiency. This document provides detailed features, specifications, dimensions, control wiring, performance data, and EcoNet Smart Thermostat integration for 2 to 5 ton units. |
![]() |
RUUD Endeavor Line Achiever Plus Series iR Residential Packaged Air Conditioners This document provides detailed specifications, features, benefits, installation information, and performance data for the RUUD Endeavor Line Achiever Plus Series iR Residential Packaged Air Conditioners, models RAC(A/X)YC. |
![]() |
Ruud RA14AZ Endeavor Achiever Series iM Air Conditioner: High Efficiency Cooling Explore the Ruud RA14AZ Endeavor Achiever Series iM Air Conditioner, featuring up to 14.3 SEER2 efficiency, robust design, and enhanced serviceability for optimal home comfort. Discover key specifications and benefits. |
![]() |
Ruud Endeavor Line Achiever Series iM Heat Pumps RP14AY - Product Specifications and Features Detailed specifications, features, and performance data for the Ruud Endeavor Line Achiever Series iM Heat Pumps, model RP14AY. Includes information on cooling and heating efficiencies, capacities, refrigerant type, unit dimensions, and warranty. |
![]() |
Ruud Endeavor Line RB2TY Air Handler Specifications Detailed specifications and performance data for the Ruud Endeavor Line RB2TY air handler, featuring Constant Torque Motor (ECM), two-stage airflow, and R-454B refrigerant. |
![]() |
Ruud Endeavor Line Achiever Plus Series Side-Discharge Heat Pump RD16AY Detailed specifications and features of the Ruud RD16AY Endeavor Line Achiever Plus Series Side-Discharge Heat Pump, including cooling and heating efficiencies, capacities, refrigerant type, unit dimensions, clearances, and warranty information. |
![]() |
Ruud Endeavor Line Ultra Series Side-Discharge Universal Heat Pump RD18AY Detailed specifications and features of the Ruud Endeavor Line Ultra Series Side-Discharge Universal Heat Pump, model RD18AY. Includes information on efficiency, capacities, dimensions, clearances, refrigerant line sizing, performance data, and limited warranty. |