Certificate of Conformity
Issued by SGS
Certificate Details
Certificate Number: N° 250008RECO08-A-CER
Issued To / License Holder: GoodWe Technologies Co., Ltd.
Trademark: GOODWE
Factory Location: No. 90 Zijin Rd., New District, Suzhou, 215011, China
Certified Product Type: Bidirectional converter
Models: GW3K-EHA-G20, GW3.6K-EHA-G20, GW5K-EHA-G20, GW6K-EHA-G20, GW8K-EHA-G20, GW9.999K-EHA-G20, GW10K-EHA-G20 (See page 3 for full details)
Technical Data:
- Nominal Voltage: 230 VAC
- Frequency: 50 Hz
- Firmware Version: 010101
- Number of Phases: Single-phase (L/N/PE)
- Isolation Transformer: No
- Control Device: Internal (See page 2)
Compliance Standard:
In compliance with the test standard UNE 217001:2020-10 "Tests for systems that prevent energy discharge to the distribution grid", taking into account the applicable requirements of the regulation: Annex I of ITC-BT-40 - Systems to prevent energy discharge to the grid "Low voltage electrical regulation and ITC. Updated edition of April 3, 2025".
The equipment is certified according to SGS internal procedure PE.T-ECPE-51 and the UNE-EN ISO/IEC 17065 standard.
Certificate Information includes:
- Technical information of power generators.
- Technical information of power analyzers.
- Installation scheme for power limitation and communication type.
- Maximum number of generators to be connected in parallel.
Issuance Date: August 19, 2025
Validity: Until August 19, 2030
Issued in: Madrid, August 19, 2025
Certifier: María J. González Soria
Issuing Body: SGS Tecnos, S.A.U. C/ Trespaderne, 29 - 28042 Madrid. This certificate is issued by SGS under its General Conditions for Product Certification at https://www.sgs.com/terms and conditions.
Installation Components & Schemes
Energy Meter (GMK110)
Brand: GOODWE
Model: GMK110
Manufacturer: GoodWe Technologies Co., Ltd.
Firmware Version: 00 03
Characteristics: 85~288 VAC; 120 A:40 mA; 5 Wmax; 50-60 Hz; 9600 imp/kWh; Power accuracy: 1%
Note: The GMK110 energy meter must be used in conjunction with the current sensor provided by the manufacturer for 1% total accuracy. An alternative power analyzer is admissible if it has the same connection regime, measurement tolerance, refresh time, and communication type.
Installation Schemes
Scheme for Single Inverter System
This scheme illustrates a single inverter installation. A PV string connects to a GoodWe Inverter. The inverter's DC output is linked to a GMK110 energy meter. The AC output from the inverter powers Loads and connects to the Grid. A Battery is also shown connected to the inverter.
Scheme for Multiple Inverters System
This scheme depicts a multi-inverter setup. Multiple PV strings feed into GoodWe Inverters (Master and Slave). Each inverter's DC output is connected to a GMK110 energy meter. The AC outputs of these inverters are connected to Loads and the Grid. A Battery is connected to the Master Inverter, and an "Ezlink" component is also shown.
Maximum Inverters in Parallel: Using the GMK110 energy meter, the maximum number of inverters connected in parallel is 8.
Full List of Product References and Nominal Characteristics
Model | PV Input Max. DC Voltage | MPPT Voltage Range | AC Output Rated Output Power | AC Output Rated Output Current |
---|---|---|---|---|
GW3K-EHA-G20 | 600 V | 50~560 V | 3.0 kW | 13.1 A |
GW3.6K-EHA-G20 | 3.6 kW | 15.7 A | ||
GW5K-EHA-G20 | 5.0 kW | 21.8 A | ||
GW6K-EHA-G20 | 6.0 kW | 26.1 A | ||
GW8K-EHA-G20 | 600 V | 50~560 V | 8.0 kW | 34.8 A |
GW9.999K-EHA-G20 | 9.999 kW | 43.5 A | ||
GW10K-EHA-G20 | 600 V | 50~560 V | 10.0 kW | 43.5 A |