Instruction Manual for KONICA MINOLTA models including: 2 1417HQ, 2 1417S, 3 1417HD, 3 1417HD2, 3 1417HL, 3 1417SL, 3 1717HD, 3 1717HD2, 3 1717HL, 3 1417S, AeroDR Flate Panel Detector, AeroDR, Flate Panel Detector, Panel Detector, Detector
KONICA MINOLTA, Inc. SKR3000P9 YR7SKR3000P9 YR7SKR3000P9 skr3000p9
File Info : application/pdf, 26 Pages, 2.40MB
DocumentDocumentMaintenance and inspection items 613 Disinfection of the DR Detector 615 AeroDR Grip sheet affixing 1 and replacement IMPORTANT · Bleach and hypochlorite are corrosive, so wash the bleach Application locations 2 off well to avoid corrosion. · Be careful not to apply any chemical for disinfection onto the wired connection connectors and the LEDs IMPORTANT · If you directly apply or spray chemical for disinfection on the DR Detector, the solution will enter the instrument through exterior gaps, causing a failure · When using a tool to affix the AeroDR Grip sheet or perform replacement, be careful not to get injured by a tip or edge of the tool 3 · Please note that if you use other chemical than instructed, it may affect the quality, performance, and safety of the DR Detector · For AeroDR Grip sheet affixing or replacement, it is recommended to ask Konica Minolta technical representative · The AeroDR 1012HQ and AeroDR 3 Detector do not use · If bodily fluid or blood from a patient has contaminated the surface of the DR Detector, disinfect with the AeroDR Grip sheet · Be careful not to scratch the DR Detector 4 a soft lint-free cloth dampened with a small quantity of the following disinfectant and wrung well · Be sure to peel off the label or used AeroDR Grip sheet because it may come off. -- Ethanol for disinfection -- Isopropanol for disinfection · After removing the label or used AeroDR Grip sheet, clean off any adhesive residue on the surface using a soft cloth moistened with anhydrous ethanol 5 -- Commercial chlorine bleach, or 1 % hypochlorite (5-fold dilution of household bleach) AeroDR Grip sheet 614 Consumables 6 IMPORTANT · Refer to each device's manual for information about periodic replacement parts and consumables for the image 7 processing controller, etc · In particular, continued use of the battery may result in deg- radation and wear, and it may no longer exhibit proper func- tioning capabilities For extended, safe use, it is necessary to replace parts which have become worn or degraded AeroDR Grip sheet 8 9 10 11 12 127 Maintenance and inspection items Installation procedure 1 Remove the label from the AeroDR Grip sheet affixing position. · Insert a precision flat-blade screwdriver, etc. into the step at the AeroDR Grip sheet affixing position to slightly turn the label over, and then remove it completely Label on the AeroDR Grip sheet affixing position 3 Peel off the center piece of the release paper from the AeroDR Grip sheet, and temporarily affix the sheet to the required position on the DR Detector · Place the AeroDR Grip sheet in the correct position so that it does not overlap the DR Detector label Release paper AeroDR Grip sheet affixing position AeroDR Grip sheet 2 Remove dust and contamination from the AeroDR Grip sheet affixing position. AeroDR Grip sheet affixing position 4 Peel off the left and right pieces of the re- lease paper from the AeroDR Grip sheet and affix the sheet to the required position on the DR Detector · Affix the sheet slowly from the center to the right and left sides to attach it tightly to the DR Detector · Confirm that the AeroDR Grip sheet has been securely placed AeroDR Grip sheet affixing position AeroDR Grip sheet 5 Repeat the same steps to affix the other three sheets 128 Chapter 7 Specifications 129 71 Specifications IMPORTANT · The following specifications described below are nominal values which may be different from actual values and may vary depending on environment and frequency of use (These are not to provide any guarantees) · All specification regarding battery is for a fully-charged battery. 711 DR Detector Item Product name (model name) Detection method Scintillator External dimensions AeroDR 1417HQ (AeroDR P-11) AeroDR 1417S (AeroDR P-12) AeroDR 1717HQ (AeroDR P-21) AeroDR 1012HQ (AeroDR P-31) AeroDR 2 1417HQ (AeroDR P-51) AeroDR 2 1417S (AeroDR P-52) P-61 (P-61) P-71 (P-71) P-81 (P-81) P-65 (P-65) P-75 (P-75) P-85 (P-85) P-82 (P-82) P-95 (P-95) P-53 (P-53) Indirect conversion method CsI (Cesium Iodide) AeroDR 1417HQ and AeroDR 1417S: 3837(W)×4602(D)×159(H) mm Description 4602 mm 159 mm AeroDR 1717HQ: 4598(W)×4602(D)×159(H) mm 3837 mm 4602 mm 159 mm 4598 mm AeroDR 1012HQ: 2818(W)×3330(D)×159(H) mm 159 mm 3330 mm 2818 mm AeroDR 2 1417HQ and AeroDR 2 1417S: 3837(W)×4602(D)×159(H) mm 4602 mm 159 mm 3837 mm 130 Item External dimensions Weight Pixel size Description AeroDR 3 1417HD, AeroDR 3 1417HD2, AeroDR 3 1417HL, AeroDR 3 1417SL, AeroDR 3 1417S: 384(W)×460(D)×15(H) mm 460 mm 15 mm 384 mm AeroDR 3 1717HD, AeroDR 3 1717HD2, AeroDR 3 1717HL: 460(W)×460(D)×15(H) mm 460 mm 15 mm AeroDR 3 1012HQ: 282(W)×333(D)×15(H) mm 15 mm 460 mm 333 mm 282 mm AeroDR 1417HQ : 29 kg AeroDR 1417S : 28 kg AeroDR 1717HQ : 36 kg AeroDR 1012HQ : 17 kg AeroDR 2 1417HQ : 26 kg AeroDR 2 1417S : 25 kg AeroDR 3 1417HD : 26 kg AeroDR 3 1717HD : 32 kg AeroDR 3 1012HQ : 15 kg AeroDR 3 1417HD2 : 26 kg AeroDR 3 1717HD2 : 32 kg AeroDR 3 1417HL : 19 kg AeroDR 3 1417SL : 18 kg AeroDR 3 1717HL : 23 kg AeroDR 3 1417S : 25 kg AeroDR 1417HQ : 175 um AeroDR 1417S : 175 um AeroDR 1717HQ : 175 um AeroDR 1012HQ : 175 um AeroDR 2 1417HQ : 175 um AeroDR 2 1417S : 175 um AeroDR 3 1417HD : 100 um/200 um AeroDR 3 1717HD : 100 um/200 um AeroDR 3 1012HQ : 100 um/200 um AeroDR 3 1417HD2 : 100 um/200 um AeroDR 3 1717HD2 : 100 um/200 um AeroDR 3 1417HL : 100 um/200 um AeroDR 3 1417SL : 100 um/200 um AeroDR 3 1717HL : 100 um/200 um AeroDR 3 1417S : 150 um 131 Specifications 1 2 3 4 5 6 7 8 9 10 11 12 Specifications Item Image area size AD conversion Maximum patient weight Communication Drive power WLAN encryption Patient doses Required time for wired/wireless switching Battery type Description AeroDR 1417HQ : 34895×42525 mm (1,994×2,430 pixels) AeroDR 1417S : 34895×42525 mm (1,994×2,430 pixels) AeroDR 1717HQ : 4249×4249 mm (2,428×2,428 pixels) AeroDR 1012HQ : 2457×2968 mm (1,404×1,696 pixels) AeroDR 2 1417HQ : 34895×42525 mm (1,994×2,430 pixels) AeroDR 2 1417S : 34895×42525 mm (1,994×2,430 pixels) AeroDR 3 1417HD : 3488×4256 mm (3,488×4,256 pixels) AeroDR 3 1717HD : 4248×4248 mm (4,248×4,248 pixels) AeroDR 3 1012HQ : 2456×2968 mm (2,456×2,968 pixels) AeroDR 3 1417HD2 : 3488×4256 mm (3,488×4,256 pixels) AeroDR 3 1717HD2 : 4248×4248 mm (4,248×4,248 pixels) AeroDR 3 1417HL : 3488×4256 mm (3,488×4,256 pixels) AeroDR 3 1417SL : 3488×4256 mm (3,488×4,256 pixels) AeroDR 3 1717HL : 4248×4248 mm (4,248×4,248 pixels) AeroDR 3 1417S : 3456×4200 mm (2,304×2,800 pixels) 16 bit (65,536 gradients) Point load: AeroDR 1417HQ : 150 kg@40 mm AeroDR 1417S : 150 kg@40 mm AeroDR 1717HQ : 150 kg@40 mm AeroDR 1012HQ : 150 kg@40 mm AeroDR 2 1417HQ : 150 kg@40 mm AeroDR 2 1417S : 150 kg@40 mm AeroDR 3 1417HD : 180 kg@40 mm AeroDR 3 1717HD : 180 kg@40 mm AeroDR 3 1012HQ : 180 kg@40 mm AeroDR 3 1417HD2 : 180 kg@40 mm AeroDR 3 1717HD2 : 180 kg@40 mm AeroDR 3 1417HL : 100 kg@80 mm AeroDR 3 1417SL : 100 kg@80 mm AeroDR 3 1717HL : 100 kg@80 mm AeroDR 3 1417S : 100 kg@80 mm Face load: AeroDR 1417HQ : 300 kg@effective image area overall AeroDR 1417S : 300 kg@effective image area overall AeroDR 1717HQ : 300 kg@effective image area overall AeroDR 1012HQ : 300 kg@effective image area overall AeroDR 2 1417HQ : 300 kg@effective image area overall AeroDR 2 1417S : 300 kg@effective image area overall AeroDR 3 1417HD : 400 kg@effective image area overall AeroDR 3 1717HD : 400 kg@effective image area overall AeroDR 3 1012HQ : 400 kg@effective image area overall AeroDR 3 1417HD2 : 400 kg@effective image area overall AeroDR 3 1717HD2 : 400 kg@effective image area overall AeroDR 3 1417HL : 400 kg@effective image area overall AeroDR 3 1417SL : 400 kg@effective image area overall AeroDR 3 1717HL : 400 kg@effective image area overall AeroDR 3 1417S : 400 kg@effective image area overall * Deadweight, even when loaded on the DR Detector, has no effect on images and the DR Detector The measurement method is based on KM standards AeroDR 1417HQ, AeroDR 1417S, AeroDR 1717HQ and AeroDR 1012HQ: Dedicated wired Ethernet connection / wireless LAN (IEEE80211a compliant) AeroDR 2 1417HQ, AeroDR 2 1417S, AeroDR 3 1417HD, AeroDR 3 1717HD, AeroDR 3 1012HQ, AeroDR 3 1417HD2, AeroDR 3 1717HD2, AeroDR 3 1417HL, AeroDR 3 1417SL, AeroDR 3 1717HL and AeroDR 3 1417S: Dedicated wired Ethernet connection / wireless LAN (IEEE80211a/n compliant) Dedicated power cable drive / battery drive Wireless encryption method : AES Authentication method : WPA2-PSK Patient doses are equivalent to 500-1000 speed film/screen systems. Less than 2 seconds Lithium ion capacitor 132 Specifications Item Number of exposable images Battery duration in standby status Battery expected lifetime Serial exposure Description AeroDR 1417HQ : 211 images/58 hours AeroDR 1417S : 211 images/58 hours AeroDR 1717HQ : 189 images/52 hours AeroDR 1012HQ : 146 images/40 hours AeroDR 2 1417HQ : 300 images/82 hours AeroDR 2 1417S : 150 images/41 hours AeroDR 3 1417HD : 100 [um] 251 images/69 hours 200 [um] 309 images/86 hours AeroDR 3 1717HD : 100 [um] 217 images/60 hours 200 [um] 276 images/76 hours AeroDR 3 1012HQ : 100 [um] 145 images/39 hours 200 [um] 165 images/45 hours AeroDR 3 1417HD2 : 100 [um] 251 images/69 hours (when the wireless serial exposure setting is enabled: 81 images/22 hours) 200 [um] 309 images/86 hours (when the wireless serial exposure setting is enabled: 83 images/23 hours) AeroDR 3 1717HD2 : 100 [um] 217 images/60 hours (when the wireless serial exposure setting is enabled: 72 images/20 hours) 200 [um] 276 images/76 hours (when the wireless serial exposure setting is enabled: 75 images/20 hours) AeroDR 3 1417HL : 100 [um] 251 images/69 hours 200 [um] 309 images/86 hours AeroDR 3 1417SL : 100 [um] 124 images/34 hours 200 [um] 147 images/41 hours AeroDR 3 1717HL : 100 [um] 217 images/60 hours 200 [um] 276 images/76 hours AeroDR 3 1417S : 150 images/41 hours * Under conditions that the interval between studies is five minutes and three images are captured in each study, assuming 20 seconds for each exposure to position a patient (when connected to the CS-7) AeroDR 1417HQ : Approx 16 hours AeroDR 1417S : Approx 16 hours AeroDR 1717HQ : Approx 15 hours AeroDR 1012HQ : Approx 76 hours AeroDR 2 1417HQ : Approx 20 hours AeroDR 2 1417S : Approx 10 hours AeroDR 3 1417HD : Approx 132 hours AeroDR 3 1717HD : Approx 122 hours AeroDR 3 1012HQ : Approx 63 hours AeroDR 3 1417HD2 : Approx 132 hours (when the wireless serial exposure setting is enabled: 24 hours) AeroDR 3 1717HD2 : Approx 122 hours (when the wireless serial exposure setting is enabled: 22 hours) AeroDR 3 1417HL : Approx 132 hours AeroDR 3 1417SL : Approx 6 hours AeroDR 3 1717HL : Approx 122 hours AeroDR 3 1417S : Approx 62 hours Above the DR Detector Service life Frame rate : 15 fps/6 fps Max acquisition time : 15 fps: 20 seconds 6 fps: 40 seconds Max number of acquisition : 15 fps: 300 6 fps: 240 Max Exposure Window : 15 fps: 13 ms 6 fps: 28 ms Pixel size : AeroDR 3 1417HD :400 um AeroDR 3 1717HD :400 um AeroDR 3 1417HD2 :400 um AeroDR 3 1717HD2 :400 um 1 2 3 4 5 6 7 8 9 10 11 12 133 Specifications 712 AeroDR Interface Unit Item Description Product name (model name) AeroDR Interface Unit (AeroDR B-1) Amount of connectable DR Detectors 2 Power requirements Power consumption AC 100/110/120/200/220/240 V ±10 %, single phase, 50/60 Hz With the DR Detector connected : Approx 160 VA (100 V-240 V) Without the DR Detector connected : Approx 33 VA (100 V-240 V) 460(W)×180(D)×285(H) mm External dimensions 285 mm Weight 115 kg 460 mm 180 mm 713 AeroDR Interface Unit2 Item Description Product name AeroDR Interface Unit2 Amount of connectable DR Detectors 2 Power requirements Power consumption AC 100/110/120/200/220/240 V ±10 %, single phase, 50/60 Hz With the DR Detector connected : Approx 160 VA (100 V-240 V) Without the DR Detector connected : Approx 33 VA (100 V-240 V) 460(W)×180(D)×285(H) mm External dimensions Weight 125 kg 460 mm 285 mm 180 mm 134 Specifications 714 Detector Interface Unit 1 Item Description Product name (model name) Detector Interface Unit (G-21) Amount of connectable DR Detectors 1 2 When the AC adapter is used: Power requirements Supplied from the DI Unit AC Adapter When the Power Supply Unit is used: Supplied from the Power Supply Unit via the Ethernet cable Power supply when cated AC adapter using the dedi- AC 100 V-240 V ±10 %, single phase, 50/60 Hz 3 Power consumption when using the dedicated AC adapter 262 A (With the DR Detector connected) 60(W)×160(D)×24(H) mm Without mounting brackets: 60(W)×130(D)×22(H) mm 4 External dimensions 160 mm 24 mm 5 60 mm Weight 03 kg Product Name : SWITCHING POWER SUPPLY (Model Number SINPRO ELECTRONICS CO,LTD MPU64-108) 6 The dedicated AC adapter specifications Dimensions Weight INPUT : 76×146×43 mm (excluding cable) : 440 g : AC100 V-240 V 162 A-072 A 47 Hz-63 Hz OUTPUT : DC24 V max262 A Safety : IEC60601-1 Class I 7 715 Detector Interface Unit 2 Item Description 8 Product name (model name) Detector Interface Unit 2 (G-52) Amount of connectable DR Detectors 1 Power requirements Supplied from the Power Supply Unit via the Ethernet cable Power consumption 423 W (max) When charging DR Detector 85(W)×160(D)×24(H) mm (Excluding lugs) 9 Without mounting brackets: 85(W)×130(D)×22(H) mm External dimensions Weight 500 g 160 mm 24 mm 85 mm 10 11 12 135 Specifications 716 Power Supply Unit Item Product name (model name) Power requirements Power consumption Amount of LAN port Description Power Supply Unit (G-11) AC 100 V-240 V ±10 %, single phase, 50/60 Hz Approx 26309 VA 3 105(W)×185(D)×150(H) mm External dimensions 150 mm Weight 2 kg 185 mm 105 mm 717 AeroDR Generator Interface Unit Item Product name (model name) Power supply Description AeroDR Generator Interface Unit (AeroDR X-1) Supplied from the AeroDR Interface Unit via the Ethernet cable 460(W)×180(D)×285(H) mm External dimensions Weight 73 kg 460 mm 285 mm 180 mm 136 Specifications 718 AeroDR Generator Interface Unit2 Item Description Product name (model name) AeroDR Generator Interface Unit2 (AeroDR Generator Interface Unit2) Power requirements When the AC adapter is used: Supplied from the dedicated AC adapter When the AeroDR Interface Unit is used: Supplied from the AeroDR Interface Unit via the Ethernet cable When the Power Supply Unit is used: Supplied from the Power Supply Unit via the Ethernet cable Power supply when cated AC adapter using the dedi- AC 100 V-240 V ±10 %, single phase, 50/60 Hz Power consumption when using the dedicated AC adapter 72 VA (100 V-240 V) 210(W)×150(D)×50(H) mm External dimensions Weight The dedicated AC adapter specifications 50 mm 150 mm 210 mm 09 kg Product Name : AC Power Adapter (Model Number Power-Win Technology Corp PW-M015A-1Y050KZ) Dimensions : 78×50×35 mm (excluding wall mount & cable) Weight : 130 g INPUT : AC 100 V-240 V 06 A-03 A 50 Hz-60 Hz OUTPUT : DC 5 V 3 A Safety : IEC60601-1 Class II 719 Generator Interface Unit 3 Item Description Product name (model name) Generator Interface Unit 3 (G-51) Power requirements When the AC adapter is used: Supplied from the dedicated AC adapter When the Power Supply Unit is used: Supplied from the Power Supply Unit via the Ethernet cable Power supply when cated AC adapter using the dedi- AC 100 V-240 V ±10 %, single phase, 50/60 Hz Power consumption when using the dedicated AC adapter 72 VA (100 V-240 V) 195(W)×150(D)×43(H) mm External dimensions Weight The dedicated AC adapter specifications 43 mm 150 mm 195 mm 10 kg Product Name : AC Power Adapter (Model Number: Power-Win Technology Corp PW-M015A-1Y050KZ) Dimensions : 78×50×35 mm (excluding wall mount & cable) Weight : 180 g INPUT : AC 100 V-240 V 06 A-03 A 50 Hz-60 Hz OUTPUT : DC 5 V 3 A Safety : IEC60601-1 Class II 1 2 3 4 5 6 7 8 9 10 11 12 137 Specifications 7110 GIU SZ Item Description Product name (model name) Power requirements GIU SZ (G-59) Supplied from the dedicated AC adapter Power supply when cated AC adapter using the dedi- AC 100 V-240 V ±10 %, single phase, 50/60 Hz Power consumption when using the dedicated AC adapter 40 W (max) When charging DR Detector 320(W)×63(L)×162(H) mm (Excluding lugs) 63 mm External dimensions 162 mm 320 mm Weight The dedicated AC adapter specifications 15 kg Product Name : SWITCHING POWER SUPPLY (Model Number SINPRO ELECTRONICS CO,LTD MPU64-108) Dimensions : 76×146×43 mm (excluding cable) Weight : 440 g INPUT : AC100 V-240 V 162 A-072 A 47 Hz-63 Hz OUTPUT : DC24 V max262 A Safety : IEC60601-1 Class I 7111 AeroDR Battery Charger Item Product name (model name) Battery charging system Power requirements Power consumption Description AeroDR Battery Charger (AeroDR D-1) Automatic charging AC 100 V-240 V ±10 %, single phase, 50/60 Hz Charging : Approx 180 VA (100 V-240 V) Standby : Approx 25 VA (100 V-240 V) 560(W)×250(D)×153(H) mm External dimensions Weight 72 kg 250 mm 153 mm 560 mm 138 Specifications 7112 AeroDR Battery Charger2 1 Item Description Product name AeroDR Battery Charger2 Battery charging system Automatic charging 2 Power requirements AC 100 V-240 V ±10 %, single phase, 50/60 Hz Power consumption Charging : 180 VA (100 V-240 V) Standby : 30 VA (100 V-240 V) 4742(W)×200(D)×2067(H) mm 3 External dimensions 2067 mm 4 4742 mm 5 120 mm Weight 6 kg 200 mm 6 7113 AeroDR Access Point 7 Item Description Product name (model name) AeroDR Access Point (AeroDR C-1) 536(W)×135(H)×105(D) mm (without antenna) 8 External dimensions 1985 mm Weight 850 g 135 mm 105 mm 536 mm 9 10 11 12 139 Specifications 7114 I/F Cable Item Product name Cable length Description AeroDR I/F Cable AeroDR I/F Cable2 I/F Cable3 067mU(G-33) I/F Cable3 1mU(G-57) I/F Cable3 8mD(G-31) I/F Cable3 8mU(G-32) I/F Cable4 15mD(G-58) I/F Cable4 8mD(G-53) I/F Cable4 8mU(G-54) I/F Cable4 2mU(G-60) AeroDR I/F Cable : 10 m/20 m AeroDR I/F Cable2 : 10 m/20 m I/F Cable3 067mU(G-33) : 067 m I/F Cable3 1mU(G-57) :1 m I/F Cable3 8mD(G-31) : 8 m I/F Cable3 8mU(G-32) : 8 m I/F Cable4 15mD(G-58) :15 m I/F Cable4 8mD(G-53) : 8 m I/F Cable4 8mU(G-54) : 8 m I/F Cable4 2mU(G-60) :2 m AeroDR I/F Cable, AeroDR I/F Cable2, I/F Cable3 8mD(G-31), I/F Cable4 15mD(G-58), I/F Cable4 8mD(G-53): 79(W)×42(D)×14(H) mm External dimensions 42 mm 14 mm 79 mm I/F Cable3 067mU(G-33), I/F Cable3 1mU(G-57), I/F Cable3 8mU(G-32), I/F Cable4 8mU(G-54), I/F Cable4 2mU(G-60): 79(W)×42(D)×14(H) mm 79 mm 42 mm 14 mm 140 Specifications 7115 AeroDR UF Cable 1 Item Product name Cable length External dimensions Description AeroDR UF Cable 2 m/5 m Wired connection connector (UIF) side: 100(W)×43(D)×14(H) mm 2 43 mm 14 mm 3 Spring connector (PIF) side: 79(W)×42(D)×14(H) mm 100 mm 79 mm 4 42 mm 14 mm 5 6 7 8 9 10 11 12 141 Specifications 7116 Cables and minor components Item Description S-SRM AC adapter AeroDR XG Cable AeroDR Collimator Cable AeroDR S-SRM Cable Serial I/F AeroDR S-SRM KIT AeroDR S-SRM KIT 2 AeroDR AC Adapter KIT DI Unit AC Adapter GIU3 AC Adapter AeroDR XG Cable Set 100V AeroDR XG Cable Set 120V AeroDR XG Cable Set 220V AeroDR XG Cable Set 230V AeroDR XG Cable Set 240V AeroDR XG Cable Set DC24V AeroDR XG Cable Set DC24V T AeroDR XG Cable Set DC G AeroDR XG Cable Set DC AeroDR XG Cable Set2 AeroDR Collimator Cable Set AeroDR S-SRM Hand S/W 5m Cable AeroDR S-SRM Cable ARX1 AeroDR S-SRM Cable ARX2 AeroDR S-SRM Cable CPX1 AeroDR S-SRM Cable CTX1 AeroDR S-SRM Cable DEX1 AeroDR S-SRM Cable DEX2 AeroDR S-SRM Cable ECX1 AeroDR S-SRM Cable ECX2 AeroDR S-SRM Cable EMX1 AeroDR S-SRM Cable GEX1 AeroDR S-SRM Cable GEX2 AeroDR S-SRM Cable GEX3 AeroDR S-SRM Cable GEX4 AeroDR S-SRM Cable GEX5 AeroDR S-SRM Cable GEX6 AeroDR S-SRM Cable GEX7 AeroDR S-SRM Cable GEX8 AeroDR S-SRM Cable GEX9 AeroDR S-SRM Cable GEX10 AeroDR S-SRM Cable HIX2 GIU3 Serial I/F Kit AeroDR S-SRM Cable ISX1 AeroDR S-SRM Cable KSX1 AeroDR S-SRM Cable KSX2 AeroDR S-SRM Cable MCX1 AeroDR S-SRM Cable NC AeroDR S-SRM Cable PHX1 AeroDR S-SRM Cable PHX2 AeroDR S-SRM Cable PHX3 AeroDR S-SRM Cable PKX1 AeroDR S-SRM Cable POX1 AeroDR S-SRM Cable SIX1 AeroDR S-SRM Cable SIX2 AeroDR S-SRM Cable SIX4 AeroDR S-SRM Cable SIX5 AeroDR S-SRM Cable SMX1 AeroDR S-SRM Cable SMX3 AeroDR S-SRM Cable SUX1 AeroDR S-SRM Cable TOX1 AeroDR S-SRM Cable TOX3 AeroDR S-SRM Cable TOX4 · AeroDR S-SRM Cables is subject to change without notice · Other AeroDR S-SRM Cables may be added without notice · Some AeroDR S-SRM Cables may not be confirmed to comply with EC Directive 93/42/EEC. 142 Specifications 7117 AeroDR SYSTEM Item Description Temperature When oper- 10 °C to 30 °C ating 10 °C Humidity Atmospheric pressure 30 °C 35 %RH to 80 %RH (ensure no water condensation) 80 %RH 700 hPa to 1060 hPa 35 %RH 1060 hPa 700 hPa Recommended storage and usage environment conditions When not operating *Limit continuous use in a hot and humid environment (35 °C to 37 °C/95 % or lower) of an incubator to within 25 minutes Temperature 10 °C to 40 °C 10 °C Humidity Atmospheric pressure 40 °C 20 %RH to 90 %RH (ensure no water condensation) 90 %RH 700 hPa to 1060 hPa 20 %RH 1060 hPa 700 hPa In storage/ transport Temperature 20 °C to 50 °C*1 -20 °C Humidity Atmospheric pressure 50 °C 20 %RH to 90 %RH (ensure no water condensation) 90 %RH 700 hPa to 1060 hPa 20 %RH 1060 hPa 700 hPa *1 However, performance warranty period when storing at 50 °C is 6 months after packing Classification Operation mode Safety IEC60601-1 Class I Continuous operation 7118 AeroDR SYSTEM 2 Item Description When operating Temperature 10 °C to 30 °C 10 °C Humidity Atmospheric pressure 30 °C 35 %RH to 80 %RH (ensure no water condensation) 80 %RH 700 hPa to 1060 hPa 35 %RH 1060 hPa 700 hPa Recommended storage and usage environment conditions When not operating Temperature 10 °C to 40 °C 10 °C Humidity Atmospheric pressure 40 °C 20 %RH to 90 %RH (ensure no water condensation) 90 %RH 700 hPa to 1060 hPa 20 %RH 1060 hPa 700 hPa In storage/ transport Temperature 20 °C to 50 °C*1 -20 °C Humidity Atmospheric pressure 50 °C 20 %RH to 90 %RH (ensure no water condensation) 90 %RH 700 hPa to 1060 hPa 20 %RH 1060 hPa 700 hPa *1 However, performance warranty period when storing at 50 °C is 6 months after packing Classification Operation mode Safety IEC60601-1 Class I Continuous operation 1 2 3 4 5 6 7 8 9 10 11 12 143 Specifications 7119 SKR 3000 Item Description Temperature 10 °C to 35 °C 10 °C Humidity Atmospheric pressure 35 °C 35 %RH to 85 %RH (ensure no water condensation) 85 %RH 700 hPa to 1060 hPa 35 %RH 1060 hPa 700 hPa Recommended storage and usage environment conditions *The temperature and humidity when operating the optional components, except Detector Interface When oper- Unit and Power Supply Unit, are: 10 °C to 30 °C and 35 % to 80 %, respectively ating *For serial exposure, temperature: 10 °C to 30 °C, humidity 35 % to 85 % *The temperature and humidity when operating the Detector Interface Unit 2, Generator Interface Unit 3, I/F Cable4 15mD, I/F Cable4 8mD and I/F Cable4 8mU, are: 10 °C to 30 °C and 35 % to 85 %, respectively *Limit continuous use in a hot and humid environment (35 °C to 37 °C/95 % or lower) of an incuba- tor to within 25 minutes When not operating Temperature 10 °C to 40 °C 10 °C Humidity Atmospheric pressure 40 °C 20 %RH to 90 %RH (ensure no water condensation) 90 %RH 700 hPa to 1060 hPa 20 %RH 1060 hPa 700 hPa Classification Operation mode Temperature Humidity Atmospheric pressure In storage/ transport 20 °C to 50 °C*1 -20 °C 50 °C 20 %RH to 90 %RH (ensure no water condensation) 90 %RH 700 hPa to 1060 hPa 20 %RH 1060 hPa 700 hPa *1 However, performance warranty period when storing at 50 °C is 6 months after packing * For GIU SZ and I/F Cable4 2mU, the temperature and humidity in storage/transport are: 20 °C to 60 °C and 20 % to 90 %, respectively Safety IEC60601-1 Class I Continuous operation 144 7120 Label DR Detector AeroDR 1417HQ/AeroDR 1417S AeroDR 1717HQ AeroDR 1012HQ AeroDR 2 Detector 145 Specifications 1 2 3 4 5 6 7 8 9 10 11 12 Specifications AeroDR 3 1417HD/AeroDR 3 1717HD AeroDR 3 1012HQ AeroDR 3 1417HD2/AeroDR 3 1717HD2 AeroDR 3 1417HL/AeroDR 3 1417SL/AeroDR 3 1717HL 146 AeroDR 3 1417S AeroDR Interface Unit FCC ID:YR7SKR3000P9 IC:1048H-SKR3000P9 AeroDR Interface Unit2 Detector Interface Unit # G-21 REF A9G5 UDI A9G550014 147 Specifications 1 2 3 4 5 6 7 8 9 10 11 12 Specifications Detector Interface Unit 2 # REF Power Supply Unit # G-11 UDI AC6050012 REF A9G4 UDI AeroDR Generator Interface Unit A9G450014 AeroDR Generator Interface Unit2 UDI REF A7RM50013 148 Generator Interface Unit 3 # REF GIU SZ UDI AAUN50012 AeroDR Battery Charger 149 Specifications 1 2 3 4 5 6 7 8 9 10 11 12 AeroDR Battery Charger2 REF A5TJ UDI A5TJ50014 AeroDR Access Point 150 US Konica Minolta Healthcare Americas, Inc 411 Newark-Pompton Turnpike, Wayne, NJ 07470, USA TEL 973-633-1500 NL Konica Minolta Business Solutions Europe GmbH Capellalaan 65,2132 JL, Hoofddorp, The Netherlands TEL +31-20-658-4100 IN Konica Minolta Healthcare India Private Ltd Office No201, 2nd Floor, Atrium 2, Next to Courtyard Marriott Hotel, Andheri Kurla Road, Chakala, Andheri (East), Mumbai - 400093, India TEL +91-22-61916900 CA Konica Minolta Business Solutions (Canada) Ltd 5875 Explorer Drive, Mississauga, Ontario, L4W 0E1, Canada TEL 905-890-6600 CN KONICA MINOLTA MEDICAL TECHNOLOGY (SHANGHAI) CO,LTD Room1602, Tower B, Hongwell International Plaza, 1602 West Zhongshan Road, Xuhui District, Shanghai 200235 China TEL 021-6422-2626 A45YBA01EN38 2024-03-19 (MA)