Fieldpiece JL3PR Job Link® System Pressure Probe User Manual & Specifications

Fieldpiece Job Link®-systeem Drukprobe Gebruikershandleiding

Model: JL3PR

Website: www.fieldpiecejoblink.com

Quick Start

  1. Install the Fieldpiece Job Link® app on your mobile device and sign up for an account if you are a new user.
  2. Remove the single screw from the yellow battery cover and install 2 x AAA batteries.
  3. Press and hold for 1 second to power on.
  4. Open "Measurements" in the Job Link app and add the probe in the tool manager.
  5. View live measurements on your mobile device from up to 300 meters away.

Scope of Delivery

  • Job Link®-system pressure probe
  • 2 x spare gaskets
  • 2 x AAA batteries
  • User Manual
  • 1-year limited warranty

WARNING: Hand-tighten the female fitting to connect and disconnect. DO NOT use the plastic housing to increase leverage. This can cause damage and leaks and void the warranty.

Do not use more than 800 psig.

Description

The JL3PR Job Link® pressure probe wirelessly transmits pressure measurements over a long range directly to the Fieldpiece Job Link® system mobile app.

Easily reach service ports in tight spaces with the angled 1/4" fitting. The rubber protective housing is both ergonomic and rugged for everyday use.

Set the switch to red or blue, and the app will immediately know which side of the system you are placing your pressure probe on.

The perfect balance of size and capability gives you exactly what you need to diagnose quickly and confidently day in and day out.

Maintenance

Cleaning

Wipe the exterior with a damp cloth. Do not use detergents or solvents.

Batteries

When the LED blinks red slowly, the batteries need to be replaced. Ensure the probe is powered off. Remove the single screw from the yellow battery cover. Install 2 x AAA batteries. You can also check battery life in the Job Link® app's tool manager.

Gasket

The black rubber gasket that seals the pressure probe to the service port can wear out over time and potentially cause a leak. This is due to overtightening or connecting to damaged service port fittings.

  1. Use needle-nose pliers or a similar tool to unscrew the Schrader valve depressor from the gasket.
  2. Remove and replace the worn gasket.
  3. Screw the depressor back into the gasket.

Schrader valve depressor

Gasket

Illustration showing the Schrader valve depressor and gasket for replacement.

Specifications

Minimum Required Device: BLE 4.0 devices with iOS® 7.0 or Android™ 5.0 (latest compatibility at www.fieldpiece.com)
Sensor Type: Relative Pressure
Connection Type: Standard 1/4" NPT female flare fitting (angled)
Measurement Range: 74 cm HgV to 0 to 4000 kPa
Accuracy: 74 cm HgV to 0 cm HgV: ±1 cm HgV
0 to 200 psig: ±1 psig;
0 to 1378 kPa: ±7 kPa
200 to 580 psig: ±2 psig;
1378 to 4000 kPa: ±14 kPa
Maximum Overload Pressure: 5500 KPa (800 psig)
Battery Type: 2 x AAA, NEDA 24A, IEC LR03
Battery Life: 150 hours, standard alkaline. LED blinks red when battery needs replacement.
Automatic Power Off (APO): 2 hours (can be disabled)
Wireless Range: 300 meters line of sight. Obstructions affect distance.
Radio Frequency: 2.4 GHz
Operating Environment: -20 °C to 50 °C at <75% RH
Storage Temperature: -20 °C to 60 °C, 0 to 80% RH (with batteries removed)
Temperature Coefficient: 0.1 x (specified accuracy) per 1 °C (-20 °C to 18 °C, 28 °C to 50 °C)
Weight: 177 g
Water Resistance: Designed to IP55
US Patent: www.fieldpiece.com/patents

Operation

Press and hold for 1 second to power on/off.

LED Color Indicators

  • Slowly blinking green: normal operation
  • Slowly blinking red: batteries need replacement

High or Low Switch

The Job Link® system app knows which side you have selected for each probe. Select suction line or liquid line and place it on the system correctly.

Suction Line (Low Side) (Blue ?)

Liquid Line (High Side) (Red ?)

Remote Data Logging

(Data logging will be available shortly after printing. Check for updates.)

Use the Job Link® system mobile app to program the JL3PR to log measurements from a specific time for up to 7 days. Automatic power off will be deactivated.

  1. Ensure JL3PR is powered off.
  2. Open the Job Link® system mobile app.
  3. Press and hold for 5 seconds to enter data logging mode. The LED will be solid green.
  4. Set the probe's data logging parameters within the app. The LED blinks green as the app sends setting instructions. The LED blinks slow blue when waiting for the programmed start time.
  5. Place the JL3PR on the system.
  6. When the programmed start time is reached, the LED blinks very slowly green to indicate logging has begun.
  7. When the programmed span has elapsed, the LED blinks and turns off.
  8. Repeat steps 1-3 and use the app to retrieve your logged data from the JL3PR.

Automatic Power Off (APO)

The pressure probe will automatically shut off after 2 hours. To disable APO, while powered on, tap the power button twice ?️. The LED will blink red briefly. To enable APO, while powered on, tap the power button twice ?️. The LED will light red briefly.

Automatic Calibration

Automatically calibrate your JL3PR by ensuring the sensor is open to the atmosphere when you power on the probe.

Limited Warranty

This product is warranted against defects in material and workmanship for one year from the date of purchase from an authorized Fieldpiece dealer. Fieldpiece will, at its option, replace or repair the defective unit, subject to verification of the defect.

This warranty does not apply to defects resulting from misuse, neglect, accidents, unauthorized repairs, modifications, or unreasonable use of the instrument.

All implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the foregoing. Fieldpiece is not liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim for such damage, expense, or economic loss.

Laws vary by state. The above limitations or exclusions may not apply to you.

Service

For international customers, warranty for products purchased outside the U.S. must be handled through local distributors. Visit our website to find your local distributor.

Designed in USA

MADE IN TAIWAN

© Fieldpiece Instruments, Inc 2022; v20

Certificates and Module ID Numbers

CE

EN 300 328

FC

2ALHR003

UK Conformity Mark

Regulatory compliance marking

Waste Electrical and Electronic Equipment

ROHS Compliant (Restriction of Hazardous Substances)

IC: Industry Canada 22518-BT003

IFETEL: Federal Telecommunications Institute RCPFI2A18-0235

FCC Statement

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to a computer or peripheral device).

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

IC Statement Regarding Radiation Exposure

This device complies with IC RSS-102 radiation limits set forth for an uncontrolled environment. This device should be installed and operated with a minimum distance of 0.5 cm between the radiator and your body.

This device complies with Industry Canada's license-free RSS-247 standard. Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867

IFETEL Statement

La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que puede causar su operación no deseada.

The operation of this equipment is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference, including interference that may cause undesired operation.

ANATEL Statement

La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que puede causar su operación no deseada.

This equipment is not covered by protection against harmful interference and may not cause interference with authorized systems.

Models: JL3PR Wireless System Pressure Probe, JL3PR, Wireless System Pressure Probe, System Pressure Probe, Pressure Probe

File Info : application/pdf, 3 Pages, 704.18KB

PDF preview unavailable. Download the PDF instead.

fieldpiece-jl3pr-hl-nl

References

Adobe InDesign 18.3 (Windows) Adobe PDF Library 17.0

Related Documents

Preview Fieldpiece JL3PR Job Link Pressure Probe Operator's Manual
Operator's manual for the Fieldpiece JL3PR Job Link Pressure Probe, detailing quick start, operation, maintenance, specifications, and warranty information for wireless pressure measurements in HVAC systems.
Preview Fieldpiece JL3RH Job Link System Flex Psychrometer Probe Operator's Manual and Specifications
Comprehensive operator's manual for the Fieldpiece JL3RH Job Link System Flex Psychrometer Probe. Includes quick start guide, detailed description, maintenance instructions, technical specifications, operation details, warranty information, and regulatory compliance.
Preview Fieldpiece JL3PR Job Link System Pressure Probe Operator's Manual
Operator's manual for the Fieldpiece JL3PR Job Link System Pressure Probe, including quick start guide, description, maintenance, specifications, operation, limited warranty, and obtaining service information.
Preview Fieldpiece Job Link System Manometer Probe JL3MN Operator's Manual
Operator's manual for the Fieldpiece Job Link System Manometer Probe (Model JL3MN), detailing quick start, description, maintenance, specifications, operation, and certifications. Learn how to use the wireless manometer probe for HVAC pressure measurements.
Preview Fieldpiece JL3MN Job Link System Manometer Probe Operator's Manual
Operator's manual for the Fieldpiece JL3MN Job Link System Manometer Probe, detailing setup, operation, maintenance, and specifications for wireless pressure measurements in HVAC systems.
Preview Fieldpiece Job Link System Probes: Easy, Long Range, Powerful HVACR Tools
Discover the Fieldpiece Job Link System Probes (JL3KH6, JL3KR4) for HVACR professionals. These versatile, tough, and innovative tools offer easy, long-range, and powerful system measurements, connecting wirelessly to your mobile device with the Job Link app. Features include auto-calibration, 1000' wireless range, and rapid temperature accuracy.
Preview Fieldpiece JL3MN Job Link® System Manometer Probe Operator's Manual
Operator's manual for the Fieldpiece JL3MN Job Link® System Manometer Probe. Covers quick start, description, maintenance, specifications, operation, static pressure testing, gas pressure testing, auto power off, certifications, and warranty information.
Preview Fieldpiece JL3MN Job Link System Manometer Probe Operator's Manual
Operator's manual for the Fieldpiece JL3MN Job Link System Manometer Probe, detailing quick start, operation, static pressure testing, gas pressure testing, maintenance, specifications, and warranty information.