Fieldpiece Job Link® System Flex Psychrometer Probe

OPERATOR'S MANUAL

Model JL3RH

Quick Start

  1. Install the Fieldpiece Job Link® system app on your mobile device and sign up for an account if you're a new user.
  2. Remove the single screw of the yellow battery cover and install 2 x AAA batteries.
  3. Press for 1 second to power on.
  4. Open Measurements in the Job Link® app and favorite the probe to the tool manager.
  5. Remove protective slip cover from tip.
  6. View live measurements on your mobile device up to 350 feet away.

What's Included

Description

The JL3RH Job Link® System Flex Psychrometer Probe sends air measurements directly to the Fieldpiece Job Link® app up to 350' away.

Measure %RH, dry bulb, wet bulb, dew point, and enthalpy at a register/grille, in the duct, or just walking around. Bend the flexible probe and slide the magnet to conveniently configure the JL3RH to your situation.

The rubberized protective housing is both ergonomic and rugged for daily use. Flip the switch and the app immediately knows which side of the system you're going to place your psychrometer probe.

Use the long wireless range, strong magnet, and flexible probe for quick and easy psychrometrics testing.

Image Description: A black, flexible probe with a white sensor tip, attached to a black body with a yellow battery cover. The Fieldpiece logo is visible on the body.

Maintenance

Cleaning

Clean the exterior with a damp cloth. Do not use detergents or solvents. Do not touch the sensor.

Batteries

When the LED slow blinks Red, the batteries must be replaced. Ensure the power is OFF. Remove the single screw from the yellow battery cover. Install 2 x AAA batteries. Monitor battery life in the app's tool manager.

Sensor Care

Cover the sensor with the slip cover when not in use. Extreme conditions or exposure to solvent vapor may offset the RH sensor. To re-calibrate, place the sensor in a controlled environment of 75%RH and between 68°F - 86°F (20°C - 30°C) for a period of 24 hours. To create a 75%RH environment, add wet salt to a clean open container (bottle cap). Be careful to not let the solution touch the probe. Place this container and the probe in a large sealed bag at room temperature, undisturbed for 24 hours.

Specifications

Feature Details
Minimum Device Requirement BLE 4.0 devices running iOS® 7.0 or Android™ 5.0 (Latest compatibility at www.fieldpiece.com)
Battery Type 2 x AAA, NEDA 24A, IEC LR03
Battery Life 150 hours typical alkaline. LED blinks red when battery replacement is needed.
Auto Power Off (APO) 2 hours (APO can be disabled)
Wireless Range 350 feet (107 meters) line of sight. Obstructions affect distance.
Radio Frequency 2.4 GHz
Operating Environment 32°F to 122°F (0°C to 50°C) at <75% RH
Storage Temperature -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with batteries removed)
Temperature Coefficient 0.1 x (specified accuracy) per 1.8°F (32°F to 64°F, 82°F to 122°F), per 1°C (0°C to 18°C, 28°C to 50°C)
Weight 0.33 lbs (150 g)
Flexible Probe 0.36" (9mm) diameter; 9.25" (235mm) length
US Patent www.fieldpiece.com/patents
Relative Humidity (%RH)
Sensor Type Capacitance polymer film
Hysteresis ±1%RH typical (Excursion of 10% to 90% to 10%RH)
Measurement Range 0%RH to 100%RH
Accuracy (At 73.4°F (23°C)) ±2.5% (10%RH to 90%RH); ±(5%) <10%RH, >90%RH
Response Time 60 seconds typical for 90% of total range
Temperature
Sensor Type Precision thermistor
Measurement Range -4°F to 140°F (-20°C to 60°C)
Accuracy ±(1°F) 32°F to 113°F, ±(0.5°C) 0°C to 45°C; ±(2°F) -4°F to 32°F, 113°F to 140°F, ±(1°C) -20°C to 0°C, 45°C to 60°C

Operation

Press for 1 second to power ON/OFF.

LED Color Indications

Supply or Return Side Switch

The Job Link® system app knows which side you have selected for each probe. Select Supply air or Return air and place it on the system appropriately.

Magnetic Hanger

You can slide the magnet to where you need it. Slide it to the top and reach high grilles/registers.

The magnet also holds the psychrometer in place when testing in duct air. Just bend the probe and slide into a 3/8" (10mm) hole in the duct.

Image Description: Illustration showing the flexible probe with its magnetic end being positioned on a metal surface or inside a duct.

Remote Data Logging

(Data logging will be available shortly after time of printing. Look for updates.)

  1. Make sure JL3RH is powered OFF.
  2. Open the Job Link® system mobile app.
  3. Press for 5 seconds to enter data logging mode. The LED will shine solid green.
  4. Set up the probe's data logging parameters within the app. The LED will blink green while the app is sending setup instructions. The LED will slow blink blue when waiting for programmed start time to occur.
  5. Place the JL3RH on the system.
  6. When the programmed start time is reached, the LED will very slowly blink green to indicate data logging has begun.
  7. When the programmed span has finished, the LED blinks and powers OFF.
  8. Repeat steps 1-3 and use the app to extract your data log from the JL3RH.

Auto Power Off (APO)

The probe will automatically power off after 2 hours. To disable APO until powered off, while power is on tap twice. The LED will briefly blink red. To enable APO, while power is on tap twice. The LED will briefly shine red.

Limited Warranty

This probe is warranted against defects in material and workmanship for one year from date of purchase from an authorized Fieldpiece dealer. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect.

This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument.

Any implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss.

State laws vary. The above limitations or exclusions may not apply to you.

Obtaining Service

For international customers, warranty for products purchased outside of the U.S. should be handled through local distributors. Visit our website to find your local distributor.

Fieldpiece Instruments, Inc 2019; v15

Certifications and Module IDs

CE

EN 300 328

FCC

2ALHR003

ANATEL

00263-18-10972

IC: Industry Canada

22518-BT003

Regulatory Compliance Mark

Waste Electrical and Electronic Equipment

ROHS

Restriction of Hazardous Substances Compliant

IFETEL: Federal Telecom Institute

RCPFI2A18-0235

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices).

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This device complies with Industry Canada licence-exempt RSS-247 standard. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

IC Radiation Exposure Statement: This equipment complies with IC RSS-102 radiation exposure limit set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0.5 cm between the radiator and your body.

Fieldpiece Instruments 1636 West Collins Avenue, Orange, CA 92867

IFETEL Statement

La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.

The operation of this equipment is subject to the following two conditions: (1) this device or device may not cause harmful interference, and (2) this device or device must accept any interference, including interference that may cause undesired operation.

ANATEL Statement

Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados.

This equipment is not subject to the protection from harmful interference and may not cause interference with duly authorized systems.

Models: JL3RH, Job Link System Flex Psychrometer Probe

File Info : application/pdf, 3 Pages, 588.31KB

PDF preview unavailable. Download the PDF instead.

fieldpiece-jl3rh-hl-en

References

Adobe PDF Library 15.0 Adobe InDesign 14.0 (Windows)

Related Documents

Preview Fieldpiece JL3PR Job Link® System Pressure Probe User Manual & Specifications
Comprehensive user manual and technical specifications for the Fieldpiece JL3PR Job Link® System Pressure Probe, covering setup, operation, maintenance, and compliance.
Preview Fieldpiece Job Link System Probes: Easy, Long Range, Powerful HVACR Tools
Discover the Fieldpiece Job Link System Probes (JL3KH6, JL3KR4) for HVACR professionals. These versatile, tough, and innovative tools offer easy, long-range, and powerful system measurements, connecting wirelessly to your mobile device with the Job Link app. Features include auto-calibration, 1000' wireless range, and rapid temperature accuracy.
Preview Fieldpiece JL3MN Job Link System Manometer Probe Operator's Manual
Operator's manual for the Fieldpiece JL3MN Job Link System Manometer Probe, detailing setup, operation, maintenance, and specifications for wireless pressure measurements in HVAC systems.
Preview Fieldpiece JL3MN Job Link® System Manometer Probe Operator's Manual
Operator's manual for the Fieldpiece JL3MN Job Link® System Manometer Probe. Covers quick start, description, maintenance, specifications, operation, static pressure testing, gas pressure testing, auto power off, certifications, and warranty information.
Preview Fieldpiece Job Link System Manometer Probe JL3MN Operator's Manual
Operator's manual for the Fieldpiece Job Link System Manometer Probe (Model JL3MN), detailing quick start, description, maintenance, specifications, operation, and certifications. Learn how to use the wireless manometer probe for HVAC pressure measurements.
Preview Fieldpiece JL3MN Job Link System Manometer Probe Operator's Manual
Operator's manual for the Fieldpiece JL3MN Job Link System Manometer Probe, detailing quick start, operation, static pressure testing, gas pressure testing, maintenance, specifications, and warranty information.
Preview Fieldpiece JL3PR Job Link Pressure Probe Operator's Manual
Operator's manual for the Fieldpiece JL3PR Job Link Pressure Probe, detailing quick start, operation, maintenance, specifications, and warranty information for wireless pressure measurements in HVAC systems.
Preview Fieldpiece Job Link System Premium Pipe Clamp Probe JL3PC Operator's Manual
Operator's manual for the Fieldpiece Job Link System Premium Pipe Clamp Probe (Model JL3PC), detailing quick start, description, maintenance, specifications, operation, and warranty.