User Manual for Hanwha Vision models including: SBP-150NBW, SBP-150NBW Cabinet, SBP-150NBW, Cabinet

Download pdf

Hanwha SBP-150NBW | Overige Producten | NetcamCenter

PDF preview unavailable. Download the PDF instead.

Manuals SBP-150NBW 240529 EN
CABINET
User Manual
SBP-150NBW

Cabinet User Manual
Copyright ©2024 Hanwha Vision Co., Ltd. All rights reserved.
Trademark Each of trademarks herein is registered. The name of this product and other trademarks mentioned in this manual are the registered trademark of their respective company.
Restriction Copyright of this document is reserved. Under no circumstances, this document shall be reproduced, distributed or changed, partially or wholly, without formal authorization.
Disclaimer Hanwha Vision makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be provided. Use of this document and the subsequent results shall be entirely on the user's own responsibility. Hanwha Vision reserves the right to change the contents of this document without prior notice.  Design and specifications are subject to change without prior notice.

PRECAUTIONS FOR INSTALLATION AND OPERATION
~ Select an installation site that can hold at least 5 times the product's weight. ~ Do not install the product in a location where chemicals or oil vapor may be present. ~ Use appropriate tools during installation: excessive force or strong impact may damage the
product. ~ Use only the accessories or camera that are compatible with this product and comply with
its technical specifications. ~ Hanwha Vision do not guarantee the quality of third-party products purchased separately. ~ When cleaning the product surface, use only a clean, soft cloth moistened lightly with
isopropyl alcohol (IPA) or water. ~ Do not install or remove the product while it rains or there is moisture remaining on the
product exterior. ~ This product must be installed by a qualified person in the electrical field.
During installation, be sure to follow local regulations of your country or region.
3

COMPONENT

As for each sales country, accessories are not the same.

Appearance

Quantity

Description

1

Main body

1

Bracket for installing the main body

1

User Manual

T20, M4 X L10

4

For camera installation

(Use the double gang)

S6, M8 X L25 4
For mount installation

4

COMPONENT

Appearance

Quantity

Description

T20, M4 X L8 20
For installation of internal accessories

1

DIN35 rail

M20 cable bushing for ø5 to 6.5 2
 Spare part Cable adapter for ø2 to 6 1  For a cable gland

2

Cable clamp for ~ ø10.6

4

Cable clamp for ~ ø6.8

2

Cable clamp for ~ ø3.3

5

OVERVIEW
Bracket for installing the main body

~ Knock-out M25 (3/4"), 3 EA M20 (1/2"), 2 EA

~ Main body installation and disassembly positions guide
~ Knock-out M25 (3/4"), 3 EA M20 (1/2"), 2 EA

~ Main body assembly guide ring, 4 EA

~ Screw holes for wall and pole mounting ø9 mm (0.36), 6 EA

6

~ Main body fixing tab M6 (0.24"), 2 EA

OVERVIEW
Front of main body

~ Door fixing screw T30, 4 EA
~ M16 cable bushing 2-hole for I/O cable
~ M20 cable bushing for LAN cable

~ M8 (0.32"), 4 EA 86 x 130mm

~ M4 (0.16"), 4 EA/EACH Double gang

7

OVERVIEW
Inside the main body

~ Door movement range 0 to 105 degrees

~ M16 cable gland 2 EA for ø4.5 to 10

~ Din35 structure ~ M25 drill-out 1 EA ~ M20 cable bushing 3 EA
for ø5 to 6.5
~ Main body fixing screw T30, 2 EA

~ Air vent ` Do not touch the air vent to prevent damage.
8

~ Cut-out M25 (3/4"), 3 EA M20 (1/2"), 2 EA

INSTALLATION
1
3-192mm (7.68")

~ Screw holes for wall and pole mounting ø9 mm (0.36"), 6 EA.

2-105mm (4.20") 2-105mm (4.20") 5-95mm (3.8")

~ Knock-out M25 (3/4"), 3 EA M20 (1/2"), 2 EA
~ Knock-out M25 (3/4"), 3 EA M20 (1/2"), 2 EA
~ Remove knock outs for floor or wall (as needed)

9

INSTALLATION
2
~ Installing on wall
~ Not included
~ Installing on pole mount
~ Included on pole mount
10

INSTALLATION
3
11

INSTALLATION
4

T30

x4

12

INSTALLATION
Cable connection
~ Electrical cables must be installed by a qualified person in the electrical field. During installation, be sure to follow local regulations of your country or region.
~ The power supply must be connected from the main supply after installation. ~ Signal or power cables must be separated and tidied up in the cabinet. Be sure
to use the provided cable clamps to organize cables. ~ To maintain the IP rating and prevent moisture ingress, unused cable glands
and bushings must be kept in factory condition. ~ M25 drill-out ~ The diameter of the cable that pass through M16 cable glands must be ø4.5 to 10 mm (0.18" to 0.4"). ~ When using the provided cable adapter , the passing cable diameter must be ø2 to 6 mm (0.08" to 0.24").
~ M20 cable bushings for ø5 to 6.5mm (0.2"to 0.26").
13

INSTALLATION
5
2.0N.m (1.4lb.ft) T30
x2
14

INSTALLATION
6
2.0N.m (1.4lb.ft) T30
x4
15

INSTALLATION
Camera installation
~ Be sure to install the camera or other items with the door closed. ~ Do not leave the door open for a long time with the camera or other items
mounted.
16

INSTALLATION
Mount installation
17

         : 7 .
Türkiye Distribütörü
EDS Elektronik Destek Sanayi ve Ticaret Ltd. ti. Meclis Mah. Teraziler Cad. Hayran Sk. (Eskisi Kiliç Sk.) No: 4 Sancaktepe / stanbul / Türkiye Tel +90.216.313.25.15
ENTES ELEKTRONK CHAZLAR MALAT VE TC. A.. Dudullu Org.San.Bölg. 1. Cad. No:23 34776 Ümraniye / stanbul / Türkiye Tel +90.216.313.01.10
TEKNOMAKS TEKNOLOJI / TEKNOMAKS BILISIM MERDVENKÖY MAH.DKYOL SOK. BUSINESS ISTANBUL No:2, Kat:7, D:B67, 34732 Kadiköy / stanbul / Türkiye Tel +90.212.217.54.22
Cihazin Ticaret Bakanliinca önerilen ortalama ömrü Cihazin EEE yönetmeliklerine uygun olduuna benzer beyan


Adobe PDF Library 17.0 Adobe InDesign 19.3 (Windows)