Lennox Mini-Split Systems Wireless Indoor Unit Controller

Operation Instructions

Model: MOSTAT60Q-1

Control Number: 507560-03

Date: 11/2020 (Supersedes 5/2019)

? This manual must be left with the owner for future reference.

Shipping and Packing List

Package 1 of 1 contains:

Important Safety Information

❗ Frequent changes to operating mode may cause system malfunction. Allow at least one minute between mode changes to allow the system to stabilize.

General

The MOSTAT60Q-1 mini-split wireless controller is a wireless local controller for Lennox mini-split indoor units.

Requirements

Using the Remote Controller

Using the Remote Control Holder

Specifications

? Table 1. Specifications

ParameterValue
Rated voltage3.0 VDC (2 AAA batteries)
Min voltage for sending signal to CPU2.4 VDC
Effective transmitting distance26 feet (8 meters)
Operation conditions23°F to 140°F (-5 to 60°C)

Function Buttons

Remote Control Layout Description: The remote control is a white, rectangular device featuring an LCD screen at the top and various buttons below. The buttons include:

Display Indicators

Description of LCD Display: The remote control's LCD screen displays various icons and information:

Operation Instructions

Batteries

  1. Remove the battery cover from the back of the remote.
  2. Insert batteries into the battery compartment.
  3. Replace the cover on the controller.

NOTE: ON/OFF, Timer, setpoint, fan speed, and all other functions will have to be reset whenever the batteries are completely discharged or are replaced.

WARNING:

Start/Stop Operation

Press the LED power button.

Select Fahrenheit or Celsius

Press and hold the Up and Down buttons at the same time for three seconds to toggle between Fahrenheit and Celsius.

To Set the Operation Mode

Press the Mode button to scroll through the mode selections.

To Set (or Change) the Room Temperature Setting (Setpoint)

Press the Up and Down arrow buttons to adjust the setpoint.

Auto Mode Operation

  1. Press the Power button; an LED light on the indoor unit displays.
  2. Press the Mode button until the display shows AUTO.
  3. Adjust temperature setpoint using Up and Down arrow buttons (range 62°F – 86°F). Fan speed is auto and is not adjustable in this mode.

Cool/Heat/Fan Mode Operation

  1. Press the Mode button to select Cool, Heat, or Fan.
  2. Adjust the temperature setpoint using Up and Down arrow buttons (range 62°F - 86°F).
  3. Press the Fan Speed button to select Auto, Low, Med, or High fan speed. Temperature set point is not displayed in Fan mode.

Dry Mode Operation

  1. Press the Power button. An LED light on the indoor unit displays.
  2. Press the Mode button to select Dry.
  3. Adjust the temperature setpoint using Up and Down arrow buttons. Fan speed is not adjustable in this mode.

Timer Operation

Timer ON and Timer OFF are used to turn on and turn off the indoor unit at selected intervals.

Timer ON Operation

  1. Press the Timer ON button. The Timer ON icon, the last auto-on time, and "h" will display.
  2. Press the Timer ON button again to set the amount of time before the indoor unit begins operation. Each press will increase the time in half-hour increments until 10 hours, then the increment becomes 1 hour.

Timer OFF Operation

  1. Press the Timer OFF button. The Timer OFF icon, the last auto-off time, and "h" will display.
  2. Press the Timer OFF button again to set the amount of time before the indoor unit stops operation. Each press will increase the time in half-hour increments until 10 hours, then the increment becomes 1 hour.

Modify Timer ON/OFF Settings

  1. Press either the Timer ON button or the Timer OFF button to modify that setting.
  2. Use the Up arrow and Down arrow buttons to change the timed operation intervals.
  3. Set the timer to 0.0 to turn off timed operation.

Troubleshooting

Fault Codes (indoor unit)

? Table 2. Fault Codes

CodeDescription
E0Indoor unit EEPROM error
E1Communication error between indoor unit and outdoor unit
E3Indoor fan speed error
E4Indoor return air temperature sensor error
E5Indoor coil temperature sensor error
ECLow refrigerant
EEHigh water level alarm
F0Outdoor current overload sensed
F1Outdoor ambient temperature sensor error
F2Outdoor coil temperature sensor error
F3Compressor discharge temperature sensor error
F4Outdoor unit EEPROM error
F5Outdoor unit fan speed error
P0Inverter module IPM error
P1High or low voltage protection
P3Outdoor unit low temperature lockout
P4Compressor drive error
--Mode conflict
P6Compressor high-pressure or low-pressure switch open
SCIndoor unit is running a self clean operation.

FCC Compliance Statement — PART 15.19

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Self Clean Sequence of Operations

The following sequence of operations is applicable to all listed indoor units (MWMA, MWMB, MMDB, MFMA, M22, M33 and MCF).

General: The Self Clean function enables drying the indoor coil after Cool or Dry mode to avoid mold. Press the CLEAN button in Cool (including cooling in auto mode and forced cooling mode) or Dry mode to enable the self-clean function. "SC" will show in the indoor display.

Heating Pump Model Sequence:

Cooling Only Model Sequence:

PDF preview unavailable. Download the PDF instead.

Lennox-Minisplit-Wireless-Remote-M0STAT60Q-1-User-Manual Adobe PDF Library 15.0

Related Documents

Preview Lennox Mini-Split Systems Wireless Indoor Unit Controller User Guide
User guide for the Lennox Mini-Split Systems Wireless Indoor Unit Controller (Model RG10L-WM, 22U49), detailing button functions, screen indicators, and operation modes for optimal use.
Preview Lennox Mini-Split Systems Wireless Indoor Unit Controller User Guide
User guide for the Lennox RG10A-CSWHB Wireless Indoor Unit Controller for Mini-Split Systems, detailing button functions, screen indicators, and operation modes.
Preview Lennox MLB/MPC Outdoor Units with M22A/M33C Indoor Units Installation Instructions
Comprehensive installation guide for Lennox MLB/MPC outdoor units and M22A/M33C indoor cassette units, covering system setup, wiring, safety, and troubleshooting for single-zone mini-split systems.
Preview Lennox M0STAT120L-1 Installation and User Guide
Comprehensive guide for installing and operating the Lennox M0STAT120L-1 wired non-programmable indoor controller, including features, compatibility, and user information.
Preview Lennox CORE Control System (M4 Unit Controller) Application Guide
This application guide provides detailed information on the Lennox CORE Control System, also known as the M4 Unit Controller, covering its features, installation, operation, and troubleshooting for commercial HVAC applications.
Preview Float Switch Kit Installation Instructions for Lennox Rooftop Units
Comprehensive installation guide for the Float Switch Kit (602799-08; 21Z07) designed for Lennox LG/LC/LH/LD/SG/SC 024-360 series rooftop units. Covers application, parts, installation steps, and unit controller configuration for M2, M3, and M4 controllers.
Preview Lennox Mini-Split Systems Service Manual: Indoor and Outdoor Unit Information
Comprehensive service manual detailing Lennox mini-split systems, covering indoor and outdoor unit specifications, dimensions, clearances, control board configurations, and installation requirements. Includes information on M22A, M33C, MMDB, MFMA, MLB, and MPC series.
Preview Lennox MMA Mini-Split Ducted Air Handler: Features, Specs & Positioning
Discover the Lennox MMA Mini-Split Multi-Position Ducted Air Handler. Learn about its high-efficiency performance, features, optional heat kits, compatible controllers, and product positioning within the Lennox lineup.