Danfoss VLT MCAD A2 IP20 AC - Technical Dimensions
Brand: Danfoss
Specifications
Type | VLT MCAD A2 IP20 AC |
Max Weight | 4.9 kg / 10.8 lb |
IP Class | IP20 AC |
Nema Class | CHASSIS |
Dimensional Views and Details
This document provides dimensional information for the Danfoss VLT MCAD A2 IP20 AC product. It displays various views of the unit, including front, side, top, and detail views, along with critical dimensions and clearance requirements.
Front View
The front view illustrates the unit's control panel, featuring a display and multiple buttons. It shows mounting holes and provides key dimensions: height of 374 mm [14.7 in] and width of 70 mm [2.8 in].
Cooling clearance requirements are specified as MIN 100 mm [3.9 in] for both top and bottom.
The unit has an "AIR INLET" at the top and an "AIR OUTLET" at the bottom.
Side Views
The side views present the unit's profile. The left side view indicates the "AIR INLET" at the top and "AIR OUTLET" at the bottom, with overall dimensions for depth of 219 mm [8.6 in] and height of 374 mm [14.7 in].
The right side view also shows the unit's depth and height, with a reference to "SIDE VIEW 3". A "MOUNTING BASE" is depicted at the bottom.
Additional side dimensions are provided: 257 mm [10.1 in] and 268 mm [10.6 in].
Top View
The top view displays the fan assembly, which serves as the air intake. It shows the unit's width of 70 mm [2.8 in] and includes a callout for "DETAIL B".
A dimension of 90 mm [3.5 in] is indicated, likely related to the fan or enclosure width.
Detail Views
Detail A (Scale 1:1): This view shows a specific feature with dimensions 5.5 mm [0.22 in] and 6.5 mm [0.26 in]. An additional dimension of 11 mm [0.43 in] is also present, likely for a mounting or connection point.
Detail B (Scale 1:1): This view presents a feature with dimensions 4.5 mm [0.18 in] and 5.5 mm [0.22 in], also likely related to mounting or connection points.
General Notes
General Tolerance: Unless otherwise specified, the tolerance is ±1 mm [0.4 inch]. All dimensions are in millimeters [inch].
Drawing Information: This drawing shows the most common version of this product variant. Small differences may occur depending on the final product configuration.
Center of Gravity: Provided for reference only; the product configuration may influence the center of gravity in all three axes.
Drawing Origin: Property of Danfoss A/S Nordborg, Denmark. Two or three dimensional reproduction of contents to be authorized by Danfoss A/S.
Drawing Number: MCAD-A2-IP20-AC
Revision: 001
Sheet: 1 of 1