This Comelit product is designed and developed for use in the realization of audio and video communication systems in residential buildings, shops, businesses, and public spaces or areas.
Installation
All activities related to the installation of Comelit products must be carried out by qualified technical personnel, following the instructions in the manuals/instructions of the respective products. The product must be installed correctly and professionally.
Conductors
- Disconnect the power supply before performing maintenance work.
- Use cables with a suitable cross-section, depending on the distances, following the instructions in the installation manual.
- It is advisable not to place the cables in the same conduit as power cables (230V or higher) before installation.
Safe Use
For safe use of Comelit products, the following is necessary:
- carefully follow the instructions in the manual/instructions,
- ensure that the installation carried out with Comelit products has not been sabotaged / damaged.
Maintenance
Comelit products do not require maintenance except for normal cleaning activities, which must be carried out as indicated in the manuals/instructions.
Any repairs must be carried out:
- for the products, exclusively by Comelit Group S.p.A.,
- for the installations, by qualified technical personnel.
Do not use alcohol or aggressive agents for cleaning.
Disclaimer
Comelit Group S.p.A. is not responsible for:
- applications other than the intended use,
- failure to observe the instructions and warnings in this manual/instructions.
Comelit Group S.p.A. reserves the right to make changes to this Manual/Instructions at any time, without prior notice.
Directives
The manufacturer, Comelit Group S.p.A., declares that this equipment complies with the applicable Directives. The full text of the EU declaration of conformity is available on the product's web page.
Pursuant to art. 26 of Legislative Decree of March 14, 2014, no. 49 “Implementation of Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)”. The symbol of the crossed-out waste bin on the equipment or packaging indicates that the product must be collected separately from other waste at the end of its life. The user must therefore take the discarded equipment to special municipal centers for separate collection of electrical and electronic waste. Instead of disposing of the equipment yourself, it can also be returned to the point of sale when purchasing a new item of a similar type. In electronics stores with a sales area of at least 400 m², it is also possible to return discarded electronic products smaller than 25 cm free of charge, without any obligation to purchase. The correct separate collection of discarded electronic equipment for recycling, treatment, and environmentally sound disposal helps to prevent possible negative consequences for the environment and health and promotes the reuse and/or recycling of the materials from which the equipment is made.
Description
Article 4681 is a color audio-video module compatible with Comelit's “Building Kit” video-door intercom systems (pure 2-wire), to be used exclusively in combination with the main line power supply unit art. 1210.
It can be installed on door stations of the Ikall, Ikall Metal, Vandalcom, Roma, and “N” series and can be expanded with additional modules that meet the most diverse system requirements.
Art. 4681 - Compatibility Table
Ikall | Ikall Metal | Vandalcom | Roma | "N"-series |
33410 | 33410M | 3268S/0 | 30xxNV | |
33411 | 33411A | 33411M | 3268S/1 | |
33412 | 33412A | 33412M | 3268S/2 |
Article 1621VC is an audio module for connecting an external PAL color camera. It is compatible with Comelit's “Building Kit” video-door intercom systems (pure 2-wire), to be used exclusively in combination with the main line power supply unit art. 1210.
It can be installed on door stations of the Ikall, Ikall Metal, Vandalcom, Roma, and “N” series and can be expanded with additional modules that meet the most diverse system requirements.
Art. 1621VC - Compatibility Table
Ikall | Ikall Metal | Vandalcom | Roma | "N"-series |
33400 | 33400M | 3262S/0 | 30xx/RI | 30xxNA |
33401 | 33401A | 33401M | 3262S/1 | |
33402 | 33402A | 33402M | 3262S/2 |
To use the signaling LEDs (busy, call sent, door open, audio active), the IKALL series front panels from kit 33400K are available, which can be purchased separately.
Installation of the Door Station
Install the camera not facing bright light sources or in positions where the person being recorded has their back to the light.
It is advisable to install an additional light source in dimly lit environments.
Connect the module frame to the earth wire.
Art. 4681
Diagram showing the installation of the Art. 4681 module.
Art. 1621VC
Diagram showing the installation of the Art. 1621VC module.
Connections
Connections 4681, 1621VC
Diagram illustrating the connections for modules 4681 and 1621VC.
- Local door opener button.
- Active input upon closing for DOOR OPEN signaling.
Connections 4681, 1621VC with separate power supply
Diagram illustrating connections for modules 4681 and 1621VC with a separate power supply.
- Local door opener button.
- Active input upon closing for DOOR OPEN signaling.
External Camera Connection (only for art. 1621VC)
Diagram showing how to connect an external camera to the 1621VC module.
- Use cable A for powering the camera from the door station (12V-150mA MAX).
- Use cable B if the camera is powered separately.
Variants
Variant for using the door station relay
Diagram showing the variant for using the door station relay.
"Relay C.NC.NO activation on relay control: 2 sec"
Set the dipswitches permanently as shown in the image (dipswitch ON 8, dipswitch OFF 1,2,3,4,5,6,7)
Variant for using a safety lock
Diagram showing the variant for using a safety lock.
Diagrams illustrating different contact configurations: Nos contactos C. NO., Nos contactos C. NC., Exclusão: contacto limpo.
Module Connections
For systems with art. 4681/1621VC and power supply unit art. 1210, the available current for the door station modules is a maximum of 100 mA.
Calculate the total consumption of the modules based on the configuration of your installation using the Consumption Table.
If the total consumption of the modules exceeds 100mA, connect an additional power supply unit (art. 1595) to the V+ V- terminals of the door station, as shown in the following image (see "Connections 4681, 1621VC with separate power supply"). In any case, the total consumption must be less than 500mA.
Consumption Table of Door Station Modules
Code | Consumption | |
Ikall and Ikall Metal Modules | ||
33433/33434/33436 | 20mA | |
33433M/33434M/33436M | 20mA | |
3336/3336M | 20mA | |
3339M | 30mA | |
3348B | with 1 activated bistable relay | 60mA |
3348BM | with 2 activated bistable relays | 80mA |
3360B | 45mA | |
3060BM | ||
3332/3332M | 20mA | |
Vandalcom Modules | ||
3262S/1/2 / 3268S/1/2 (with Art. 1172B) | 8 mA | |
3064S (with Art. 1172B) | 16 mA | |
3070S | only with 1595 | |
3072S | only with 1595 | |
Modules for Monopaneel Door Station | ||
3063D | 8mA | |
1172B led lamp | 8mA | |
Simplekey Modules | ||
SK90001 | 50mA | |
SK90011 | 50mA | |
ACM/R | 60mA | |
ACM/500-2 | 60mA |
Ikall/ Ikall Metal Modules
Connecting Button Modules 33433, 33434, 33436, 33433M, 33434M, 33436M
Diagram showing the connection of button modules.
Max. 5 modules (max. 17 modules with extra power supply).
Connecting Art. 3348B, 3348BM
Diagram showing the connection of art. 3348B, 3348BM.
Max. 2 modules (max. 17 modules with extra power supply).
Connecting Art. 3360B, 3360BM
Diagram showing the connection of art. 3360B, 3360BM.
Vandalcom Modules
Connecting Art. 3064S and Art. 1172B
Diagram showing the connection of art. 3064S and art. 1172B.
- Use the supplied cable for art. 3262S and 3268S.
- Insulate the cables after they are cut.
- Max. 6 art. 3064S plus a maximum of 6 art. 1172B.
- Use the art. 1172B lamp for lighting the nameplates. The lamp is polarized.
Connecting Art. 3064S and Art. 1172B with extra power supply
Diagram showing the connection of art. 3064S and art. 1172B with an extra power supply.
- Use the supplied cable for art. 3262S and 3268S.
- Insulate the cables after they are cut.
- Max. 30 art. 3064S plus a maximum of 30 art. 1172B.
- Use the art. 1172B lamp for lighting the nameplates. The lamp is polarized.
Modules for Monopaneel Door Station
Connecting Art. 3063D
Diagram showing the connection of art. 3063D.
- Use the cable supplied with art. 1250IV and 12501A.
- Insulate the cables after they are cut.
- Max. 6 art. 3063D plus a maximum of 6 art. 1172B.
- Use the art. 1172B lamp for lighting the nameplates. The lamp is polarized.
Connecting Art. 3063D with extra power supply
Diagram showing the connection of art. 3063D with an extra power supply.
- Use the cable supplied with art. 1250IV and 12501A.
- Insulate the cables after they are cut.
- Max. 30 art. 3063D plus a maximum of 30 art. 1172B.
- Use the art. 1172B lamp for lighting the nameplates. The lamp is polarized.
Simplekey Modules
Connecting Art. SK9015 for connecting readers Art. SK90001, Art. SK90011
Diagram showing the connection of art. SK9015 for connecting readers.
Max. 5 modules
Button Programming
Diagrams illustrating the steps for programming buttons.
# Set the user code via the dipswitches, see the addressing table.
Information about the installation
- The art. 4681/1621VC module functions as a main door station by default (busy signal for a set time). To set it as a secondary door station (busy signal active as long as the main line is in use), all dipswitches of the switch must be set to ON.
- If a call is made from the door station and a busy tone is heard instead of the doorbell, it means that a call to another door station is active.
System Performance and Schematics
For more information on system performance and to view installation schematics, click on the system type that best suits your needs:
- Audio/Video System Building Kit for creating audio-video systems for apartment buildings.
Technical Specifications
Art. 4681
KEY FEATURES | |
Simplebus Top system | No |
Compatible with Building Kit system | Yes |
Vip system | No |
Audiosystem | No |
Audio/Videosystem | Yes |
Color Camera | Color |
Video coding | Mpeg |
Type sensor | 1/3" CCD |
Horizontal resolution (TVL) | 540TVL |
Minimum illuminance (lux) | 0.35lux |
Lens size | 3.6mm |
Adjustable camera | Yes |
Terminals LL V+ V- RTE DO GND SE- SE+ COM NC NO | |
Microphone | Yes |
Microphone volume control | No |
Loudspeaker | Yes |
Loudspeaker volume control | Yes |
Relative humidity | 25%-75% |
Art. 1621VC
KEY FEATURES | |
Simplebus Top system | No |
Compatible with Building Kit system | Yes |
Vip system | No |
Audiosystem | No |
Audio/Videosystem | Yes |
Terminals LL V+ V- RTE DO GND SE- SE+ COM NC NO | |
Microphone | Yes |
Microphone volume control | No |
Loudspeaker | Yes |
Loudspeaker volume control | Yes |
Relative humidity | 25%-75% |
Programming Button Functions
DIPSWITCH ON
CODE | DIPSWITCH ON | FUNCTIONS |
Anti-fogging | ||
212 | 3,5,7,8 | OFF (standard) |
213 | 1,3,5,7,8 | ON |
Audiovisual messages | ||
195 | 1,2,7,8 | Hebrew |
196 | 3,7,8 | Polish |
197 | 1,3,7,8 | Catalan |
198 | 2,3,7,8 | Galician |
199 | 1,2,3,7,8 | Basque |
206 | 2,3,4,7,8 | Danish |
207 | 1,2,3,4,7,8 | Norwegian |
211 | 1,2,5,7,8 | Swedish |
215 | 1,2,3,5,7,8 | Italian |
216 | 4,5,7,8 | French |
217 | 1,4,5,7,8 | Spanish |
218 | 2,4,5,7,8 | Dutch |
219 | 1,2,4,5,7,8 | Greek |
220 | 3,4,5,7,8 | English |
221 | 1,3,4,5,7,8 | German |
222 | 2,3,4,5,7,8 | Portuguese |
Voice messages (for door open warning) | ||
202 | 2,4,7,8 | Activates the voice message (for door open warning) when the RTE contact is closed. |
203 | 1,2,4,7,8 | Deactivates the voice message (for door open warning) when the RTE contact is closed (standard). |
210 | 2,5,7,8 | visual messages only |
214 | 2,3,5,7,8 | OFF (standard) |
Relay Control Management | ||
N.B. art. 1256 must not be present in the general relay control mode on the installation. | ||
227 | 1,2,6,7,8 | Relay control on serial line S: enabled. |
228 | 3,6,7,8 | Relay control on serial line S: disabled (standard). |
229 | 1,3,6,7,8 | Activation of relay C.NC.NO on relay control: 2 sec. |
230 | 2,3,6,7,8 | Activation of relay C.NC.NO on relay control: 4 sec. |
231 | 1,2,3,6,7,8 | Activation of relay C.NC.NO on relay control: 8 sec. |
Door Lock | ||
245 | 1,3,5,6,7,8 | Door lock time: 2 sec. + tone off (standard) |
246 | 2,3,5,6,7,8 | Door lock time: 4 sec. |
247 | 1,2,3,5,6,7,8 | Door lock time: 8 sec. |
248 | 4,5,6,7,8 | Door lock confirmation tone: enabled. |
251 | 1,2,4,5,6,7,8 | Relay C.NC.NO in parallel connection with SE (standard). |
252 | 3,4,5,6,7,8 | Door lock operation always enabled (standard). |
253 | 1,3,4,5,6,7,8 | Door lock operation enabled only for the called user. |
Installation Functions | ||
232 | 4,6,7,8 | Answer time: 60 sec. (standard). |
233 | 1,4,6,7,8 | Answer time: 120 sec. |
234 | 2,4,6,7,8 | Answer time: 30 sec. |
235 | 1,2,4,6,7,8 | Talk time: 90 sec. (standard). |
236 | 3,4,6,7,8 | Talk time: 180 sec. |
237 | 1,3,4,6,7,8 | Visual call: enabled (standard). |
238 | 2,3,4,6,7,8 | Visual call: disabled. |
239 | 1,2,3,4,6,7,8 | Confirmation tone on user call: enabled (standard). |
240 | 5,6,7,8 | Confirmation tone on user call: disabled. |
243 | 1,2,5,6,7,8 | Reset time: 10 sec. (standard). |
244 | 3,5,6,7,8 | Reset time: 1 sec. |
208 | 5,7,8 | Activates the "Wait for reset" for door lock operation (standard). |
209 | 1,5,7,8 | Deactivates the "Wait for reset" for door lock operation (the answer time or talk time is applied). |
249 | 1,4,5,6,7,8 | Send call: single (standard). |
250 | 2,4,5,6,7,8 | Send call: triple. |
Installation Mode | ||
0 | Simplebus (standard). | |
255 | 1,2,3,4,5,6,7,8 | Simplebus Top (NO Art. 4681/4). |
254 | 2,3,4,5,6,7,8 | Reset default. |
Information about the installation
- The art. 4681/1621VC module functions as a main door station by default (busy signal for a set time). To set it as a secondary door station (busy signal active as long as the main line is in use), all dipswitches of the switch must be set to ON.
- If a call is made from the door station and a busy tone is heard instead of the doorbell, it means that a call to another door station is active.
System Performance and Schematics
For more information on system performance and to view installation schematics, click on the system type that best suits your needs:
- Audio/Video System Building Kit for creating audio-video systems for apartment buildings.