Technical manual for single-family KIT Art. 8461V - Door Entry ...

Wall-mounted external unit for Quadra series door entry monitor. Die-cast aluminium front panel, wide-angle colour camera and single LED for lighting at night.

[PDF] Technical manual for single-family KIT Art. 8461V - Door Entry Direct

Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force.

PDF preview unavailable. Download the PDF instead.

Quadra Mini HF 8461V Technical Manual ?srsltid=AfmBOop3L 7vXBQRnNI2ydiucQpPA Tyykedykz4eGyGsGKG9uINyJAV
EN
TECHNICAL MANUAL

Technical manual for single-family KIT Art. 8461V

Passion.Technology. Design.

Warning
· Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force. Do not tamper with the internal elements offering protection against short circuits and overcurrents.
· All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. declines any responsibility for improper use of the apparatus, for any alterations made by others for any reason or for the use of non-original accessories or materials.
· All the products comply with the requirements of the 2014/30/UE, 2014/35/UE directives, as certified by the CE mark they carry.
· Do not route the riser wires in proximity to power supply cables (230/400V). · Do not insert objects or pour liquids into the device. · Installation, mounting and assistance procedures for electrical devices must only be performed by specialised
electricians. · Cut off the power supply before carrying out any maintenance work. · The camera must not be installed opposite bright light sources, or in places where the filmed subject is against the
light. To resolve the aforementioned problem, we recommend changing the installation height of the camera. · Cameras with colour sensor have poorer sensitivity in low light conditions than black/white cameras. We therefore
recommend, in dimly lit environments, to install an additional light source. · IMPORTANT: to prevent a malfunction of the device, make sure that the metal fascia of Art. 4893 does not rub against
any other metal parts and damage their insulation.
2

Table of contents

Warning............................................................................................. 2 Package Contents............................................................................ 4 Operating distances......................................................................... 5 Power supply unit Art. 1209............................................................. 6
Description................................................................................................ 6 External unit Art. 4893...................................................................... 7
Description................................................................................................ 7 Installation................................................................................................. 8 External unit settings..............................................................................10 Call address programming for 2-4 users and additional external unit....................................................................11 Programming a generic call address....................................................12 Riser addresses.......................................................................................13 Description of Monitor Art. 6721W............................................... 14 Soft-touch key description.....................................................................15 Indicator LED description......................................................................15 Installation....................................................................................... 16 Removing / Fitting the terminal.............................................................17 Fitting upgrade KIT Art. 6734W..............................................................17 Operation......................................................................................... 18 Answer incoming call.............................................................................18 Activation/deactivation automatic answer mode................................18 Monitor configuration.................................................................... 18 Standard configuration for soft-touch keys.........................................18 Advanced monitor configuration...........................................................19
Warning.............................................................................................. 19 Programming for intercom call...........................................................19
Programming/deleting intercom address...................................19 Programming buttons for intercom call......................................20 Direct programming of intercom call..........................................21 Programming keys for generic or coded actuator.............................22 Programming buttons for other functions..........................................23 Programming range...........................................................................24 Monitor ringtone selection.................................................................24 Programming reset............................................................................25 Operation......................................................................................... 26 To make a call from an external unit.....................................................26 Self-ignition.............................................................................................. 26 Operation with additional internal units................................................26 Operation with additional external units...............................................26 Additional door-entry phones Art. 2638....................................... 27 Installation of door-entry phone Art. 2638............................................28 Programming of door-entry phone Art. 2638.......................................28

Wiring diagrams............................................................................. 29 KIT 8461V: standard single-family system. Switching on/voltage check with system in standby..........................29 KIT 8461V: expansion for two-family system.......................................30 KIT 8461V: expansion for 4-user system..............................................31 KIT 8461V: expansion with second external unit 4893 and switching device Art. 1405..............................................................32 KIT 8461V: expansion with 3 external units 4893 and switching device Art. 1404..............................................................33 Wiring diagram for system with 2 single-family KITS KIT 8461V and main external unit Art. 4893............................................................34 KIT 8461V: additional actuator relay Art. 1256.....................................35 KIT 8461V: additional remote camera module Art. 1409.....................36 KIT 8461V: additional 2 secondary monitors in cascade connection............................................................................37 Connection diagram for two-family system with one main monitor and 2 secondary monitors (cascade connection)................................37 Connection diagram for system with maximum expansion in branch connection for single call address.......................................38 Connection diagram for cascade connection from internal video unit of additional door-entry phones Art. 2610 and Art. 6228(B)(W).................................................................38 Connection diagram for branch connection from internal video unit of additional door-entry phones Art. 2610 and Art. 6228(B)(W).................................................................38 Connection diagram for branch connection from riser of additional door-entry phones Art. 2628/2638 and Art. 6228(B)(W).......................39 Door open indication use variant..........................................................39 Variant with security door lock and additional power supply.............40 Floor door call connection variant........................................................40 Using the RC network for door lock filter on relay contacts..............40

3

Package Contents
The KIT components are supplied preconfigured for use with the basic version; this manual also includes information for any system configuration and customisation perceived as necessary by the installer.

8461V (/BM)

4893

6721W(/BM)

1209

4893 External unit

×1

×1

×1

×1

Replaceable nameplates
for 1 user for 2 users for 3 users
6721W(/BM) - Monitor

×3

×3

×1

×1

×1

×4

×4

1209 - Power supply unit

×2 ×2 ×1

L

N

L2 L1

×1

4

1214-2C

Technical manual

IT
MANUALE TECNICO

EN
TECHNICAL MANUAL

FR
MANUEL TECHNIQUE

NL
TECHNISCHE HANDLEIDING

DE
TECHNISCHES HANDBUCH

ES
MANUAL TÉCNICO

PT
MANUAL TÉCNICO

Manuale tecnico KIT monofamiliare Art. 8461V Technical manual for single-family KIT Art. 8461V Manuel technique KIT un appel Art. 8461V Technische handleiding enkelvoudige installatieKIT Art. 8461V Technisches Handbuch KIT Einteilnehmerinstallation Art. 8461V Manual técnico del KIT unifamiliar Art. 8461V Manual técnico KIT monofamiliar Art. 8461V

Passion.Technology. Design.

IT Avvertenze

électriques sont réservées à des électriciens spécialisés.

· Effettuare l'installazione seguendo scrupolosamente le istruzioni fornite dal

· Couper l'alimentation avant d'effectuer toute opération d'entretien.

costruttore ed in conformità alle norme vigenti. Non manomettere le protezioni

· Installeer de camera niet tegenover felle lichtbronnen of op plaatsen waar de

interne contro cortocircuiti e sovracorrenti.

opgenomen persoon met de rug naar het licht staat. Om het hierboven beschreven

· Tutti gli apparecchi devono essere destinati esclusivamente all'uso per cui sono

probleem op te lossen, is het raadzaam de installatiehoogte van de camera aan

stati concepiti. Comelit Group S.p.A. declina ogni responsabilità per un utilizzo

te passen.

improprio degli apparecchi, per modifiche effettuate da altri a qualunque titolo e

· Camera's met kleurensensor hebben in schaars verlichte omstandigheden een

scopo, per l'uso di accessori e materiali non originali.

lagere gevoeligheid dan zwart-witcamera's. Het is daarom raadzaam om in

· Tutti i prodotti sono conformi alle prescrizioni delle direttive 2014/30/UE, 2014/35/

schaars verlichte omgevingen een extra lichtbron te plaatsen.

UE e ciò è attestato dalla presenza della marcatura CE sugli stessi.

· IMPORTANT : pour ne pas compromettre le fonctionnement du dispositif,

· Evitare di porre i fili di montante in prossimità di cavi di alimentazione (230/400V).

s'assurer que la façade en métal de l'article 4893 n'entre pas en contact avec

· Non inserire oggetti né versare liquidi all'interno del dispositivo.

d'autres parties métalliques, ce qui risquerait d'endommager son revêtement

· Gli interventi di installazione, montaggio e assistenza agli apparecchi elettrici

isolant.

devono essere eseguiti esclusivamente da elettricisti specializzati.

· Togliere l'alimentazione prima di effettuare qualsiasi manutenzione.

· La telecamera non deve essere installata di fronte a grandi sorgenti luminose,

oppure in luoghi dove il soggetto ripreso rimanga molto in controluce. Per risolvere NL Waarschuwingen

il problema precedentemente descritto, si consiglia di modificare l'altezza di

· Voer de installatiewerkzaamheden zorgvuldig uit volgens de door de fabrikant

installazione della telecamera.

geleverde instructies en met inachtneming van de geldende normen. De interne

· Le telecamere con sensore a colori, presentano in condizioni di scarsa luminosità,

beveiligingen tegen kortsluiting en overstroom niet forceren.

una sensibilità inferiore rispetto alle telecamere in bianco e nero. Si consiglia

· Alle apparaten mogen alleen gebruikt worden voor het beoogde doel waarvoor

pertanto, in ambienti poco illuminati di prevedere una fonte di illuminazione

ze zijn ontworpen. Comelit Group S.p.A. is niet verantwoordelijk voor oneigenlijk

aggiuntiva.

gebruik van de apparatuur, voor wijzigingen die om welke reden dan ook door

· IMPORTANTE: per non compromettere il funzionamento del dispositivo assicurarsi

derden zijn aangebracht, en voor het gebruik van accessoires en materialen die

che il frontale in metallo dell'articolo 4893 non sfreghi su altre parti metalliche

niet door de fabrikant zijn aangeleverd.

danneggiando il proprio rivestimento isolante.

· Alle producten voldoen aan de eisen van de richtlijn 2014/30/UE, 2014/35/UE. Dit

wordt bevestigd door het CE-label op de producten.

· Monteer de draden van de stamleiding niet in de buurt van voedingskabels

(230/400V).

EN Warning

· Voorkom het binnendringen van vreemde voorwerpen of vloeistoffen in het toestel.

· Install the equipment by carefully following the instructions given by the

· De installatie-, montage- en servicewerkzaamheden aan de elektrische apparaten

manufacturer and in compliance with the standards in force. Do not tamper with

mogen uitsluitend door gespecialiseerde elektriciens worden verricht.

the internal elements offering protection against short circuits and overcurrents.

· Sluit de voeding af voordat u onderhoudswerkzaamheden uitvoert.

· All the equipment must only be used for the purpose it was designed for. Comelit

· Installeer de camera niet tegenover felle lichtbronnen of op plaatsen waar de

Group S.p.A. declines any responsibility for improper use of the apparatus,

opgenomen persoon met de rug naar het licht staat. Om het hierboven beschreven

for any alterations made by others for any reason or for the use of non-original

probleem op te lossen, is het raadzaam de installatiehoogte van de camera aan

accessories or materials.

te passen.

· All the products comply with the requirements of the 2014/30/UE, 2014/35/UE

· Camera's met kleurensensor hebben in schaars verlichte omstandigheden een

directives, as certified by the CE mark they carry.

lagere gevoeligheid dan zwart-witcamera's. Het is daarom raadzaam om in

· Do not route the riser wires in proximity to power supply cables (230/400V).

schaars verlichte omgevingen een extra lichtbron te plaatsen.

· Do not insert objects or pour liquids into the device.

· BELANGRIJK: om de werking van het toestel niet in gevaar te brengen, dient

· Installation, mounting and assistance procedures for electrical devices must only

u ervoor te zorgen dat het metalen frontpaneel, Art. 4893, niet over de andere

be performed by specialised electricians.

metalen onderdelen schuurt en daarmee de isolerende bekleding beschadigt.

· Cut off the power supply before carrying out any maintenance work.

· The camera must not be installed opposite bright light sources, or in places where

the filmed subject is against the light. To resolve the aforementioned problem, we

· ·

recommend changing the installation height of the camera. Cameras with colour sensor have poorer sensitivity in low light conditions than black/white cameras. We therefore recommend, in dimly lit environments, to install an additional light source. IMPORTANT: to prevent a malfunction of the device, make sure that the metal fascia of Art. 4893 does not rub against any other metal parts and damage their insulation.

DE

Hinweise · Der Einbau muss strikt nach Herstelleranweisungen und unter Einhaltung
der einschlägigen Vorschriften erfolgen. Nicht den internen Kurzschluss- und Überlastungsschutz verändern. · Alle Geräte dürfen nur für den Zweck eingesetzt werden, für den sie entwickelt worden sind. Comelit Group S.p.A. übernimmt keine Haftung für unsachgemäßen Gebrauch der Geräte, für durch Dritte vorgenommene Änderungen oder die

Verwendung von Nicht-Original-Zubehör und -Ersatzteilen.

· Alle unsere Produkte erfüllen die Anforderungen der Richtlinie 2014/30/UE,

FR Avertissements · Effectuer l'installation en suivant scrupuleusement les instructions fournies par le constructeur et conformément aux normes en vigueur. Ne pas toucher les protections internes contre les courts-circuits et les surcharges. · Tous les appareils doivent être strictement destinés à l'emploi pour lequel ils ont été conçus. La société Comelit Group S.p.A. décline toute responsabilité en cas de mauvais usage des appareils, pour des modifications effectuées par d'autres personnes pour n'importe quelle raison et pour l'utilisation d'accessoires et matériaux non d'origine. · Tous les produits sont conformes aux prescriptions des directives 2014/30/UE, 2014/35/UE. L'application du marquage CE atteste cette conformité. · Éviter de placer les fils de montant à proximité des câbles d'alimentation (230/400V). · Ne jamais introduire d'objets ni verser de liquides à l'intérieur du dispositif. · Les interventions d'installation, de montage et d'assistance aux appareils

2014/35/UE, was durch die CE-Kennzeichnung bestätigt wird. · Die Kabel der Steigleitung nicht in Nähe der Stromkabel (230/400 V) verlegen. · Keine spitzen Gegenstände in das Gerät einführen und dieses gegen das
Eindringen von Flüssigkeiten schützen. · Installation, Einbau und Wartung der elektrischen Geräte dürfen nur von einem
Elektrofachmann ausgeführt werden. · Vor Wartungseingriffen immer die Stromversorgung unterbrechen. · Die Kamera darf nicht vor großen Lichtquellen oder an Stellen installiert werden,
an denen das Motiv zu sehr im Gegenlicht steht. Zur Lösung des Problems ist es angebracht, die Installationshöhe der Kamera zu ändern. · Die Kameras mit Farbsensor haben bei schlechten Lichtverhältnissen eine geringere Empfindlichkeit als Schwarz/Weiß-Kameras. In schlecht beleuchteter Umgebung wird daher empfohlen, für eine zusätzliche Lichtquelle zu sorgen · WICHTIG: Um die Funktionsweise des Gerätes nicht zu beeinträchtigen, sicherstellen, dass die Metallfrontblende des Artikels 4893 nicht gegen andere Metallteile reibt und dadurch die eigene Isolierung beschädigt.

Operating distances
The total number of internal units with the same user code and call repetition devices (additional ringtone Art. 1229A) connected to these internal units cannot exceed 4 (with a maximum of 1 main internal unit and 3 secondary internal units). Connect only one call repetition device for each internal unit.

B

6721W

1216 1214/2C

6721W

A

1209

4893

1214/2C
A
1209
4893

Comelit Art. 4577/4579 1 mm2 (Ø 1,2 mm AWG 17)
UTP5 cat. 5 0,2 mm2 (Ø 0,5 mm AWG 24)
0,28 mm2 (Ø 0,6 mm AWG 23)
0,5 mm2 (Ø 0,8 mm AWG 20)
1 mm2 (Ø 1,2 mm AWG 17)
1 mm2 (Ø 1,2 mm AWG 17)
1,5 mm2 (Ø 1,4 mm AWG 15)
*UTP5 cat. 5 0,2 mm2 (Ø 0,5 mm AWG 24) MULTI PAIR CABLE
GREEN GREEN / WHITE ORANGE / WHITE
ORANGE BLU
BLU / WHITE BROWN / WHITE
BROWN

A MAX 200 m (655 feet) 100 m (330 feet) 100 m (330 feet) 100 m (330 feet) 100 m (330 feet)
80 m (260 feet)
100 m (330 feet)
120 m (390 feet)

6721W
B MAX 100 m (330 feet) 60 m (195 feet) 60 m (195 feet) 60 m (195 feet) 60 m (195 feet) 40 m (130 feet) 60 m (195 feet)
70 m (230 feet)

UTP cable with multi-cable connection: FOLLOW THE COLOURS SHOWN IN THE DIAGRAM! 5

Power supply unit Art. 1209
Description
31 Vdc power supply unit for 2-wire KIT, for direct connection to the external unit and internal unit. Equipped with overload and short circuit protection. Input voltage 110-240 VAC. Dimensions: 108x90x62 mm (6 DIN modules).

Dopo un cortocircuito,per ripristinare l'apparecchio, interrompere l'alimentazione per circa 1 minuto. To reset the operation after a short circuit,cut o mains voltage for about 1 minute. Apres un court circuit, pour remettre en fonction l'appareil, interrompre l'alimentation pendant environs une minute.

INPUT/D'ENTREE 110V-240V

L

N

800mA 50-60Hz ta=40°C

R

C

US

257258

Ar t.1209
OUTPUT/SORTIE 31V 0.5A 1.2A 1'on/5'o
L1 L1 L2 L2

12

34

1. L N mains power input 110-240 V~ 2. Terminal protection 3. L1 L1 main bus line input (31 V ) 4. L2 L2 riser bus line output (31 V )
The electrical system of the building must be fitted with an (easily accessible) omnipolar mains switch with a contact opening of at least 3 mm, which is capable of cutting off the power supply of the device.

6

External unit Art. 4893
Description
Wall-mounted external unit for Quadra series door entry monitor. Die-cast aluminium front panel, wide-angle colour camera and single LED for lighting at night. Capacitive buttons with the option of setting 1 to 4 call buttons via dip switch. Indicator LED for call sent, lock-release activated, audio activated and system busy. Loudspeaker volume adjustment and audio balancing. Bus line power supply. External unit dimensions: 95x195x23 mm.

1 2 3
4
1

5

1

2
6

1 2 3 4

JP1 NC NO
8

9

10 11 12

NO C

NC

JP1 NC
13

14

NO

15

NO C

NC

16 7

1
1. Die-cast aluminium cover
2. Camera lighting LED set by default to activate in response to a call (can be disabled by setting DIP 7 to ON, see page 10)
3. Wide-angle colour camera
4. Loudspeaker
5. Indicator LED call sent lock-release enabled audio enabled system engaged
6. Transparent front panel with label-holder in 1 / 2 / 4 button versions (default 1 button)
ff To send the call, touch the button corresponding to the user you want to contact
7. Microphone

2
8. Terminal block M1 LL bus line connection RTE timed local lock-release input COM common input for RTE and DO contacts DO door open indication input
9. Terminal block M2 SE- SE+ connection for electric door lock NC relay normally closed contact NO relay normally open contact C relay common contact
10. Loudspeaker volume control
11. Audio balance
12. JP1 enable RC network for door lock filter on relay contacts (see page 40)
13. CNF programming confirmation switch
14. PR programming input/output switch
15. DIP SWITCH for function programming
16. Microphone volume control

7

Installation
1

1
2

2
3

2
OPEN
1

163 cm 130 cm

1
4

CAUTION! Tighten properly to avoid leaks
2
5

L L RTCEOM

6

7

optional

8

You can download the free software (Art. 1235A) from the website www.comelitgroup.com to print the entrance panel name tags, using the adhesive pre-cut sheets available in our catalogue (Art. 1217)

REMOVE

Replaceable nameplates

for 1 user

for 2 users for 3 users

JOHN SMITH PETER WHIT

MAKE SURE THE POSITIONING IS CORRECT BEFORE GLUEING THE NAMES IN PLACE

AVAILABLE NAMEPLATES

8

9

Labels must be made of non-conductive material so as not to compromise the operation of the soft-touch buttons

1 2

10

11

12

1 1

1

Leakage

risk

1

2
13

2

CLOSE

MINIMUM 8

FULL

14

TURNS

Before fixing the screw, make sure that you do not need to programme the external unit and make sure that the metal front panel does not rub against other metal parts, with consequent risk of damage to its insulating coating

CAUTION!: To ensure that the product remains water-tight: make sure that the fixing procedure is carried out correctly

9

External unit settings

ff Set the DIP-switches of S1 corresponding to the function that you want to programme as shown in the table below

DIP 1

DIP 2

DIP 3

DIP 4

DIP 5

DIP 6

DIP 7

DIP 8

ON

ON

ON

ON

ON

ON

ON

ON

The lock- lock-release relay activation reset wait time:

Call

release relay activation time: time: 8 sec.

1 sec.

transmission:

and the

8 sec.

triple

second relay

are controlled

by 2 separate

buttons (e.g.

lock-release

button and

actuator

button)

confirmation tones (call, lock-release, relay, audio enabled):
disabled

Camera lighting LED:
disabled

LED lighting of nameholder front panels:
OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

The lock- lock-release relay activation reset wait time:

Call

release relay activation time: time: 2 sec.

10 sec. transmission:

and the

2 sec.

single

second relay

are controlled

by a single

button (e.g.

lock-release

button)

confirmation tones (call, lock-release, relay, audio enabled):
enabled

Camera lighting LED:
enabled

LED lighting of nameholder front panels:
ON

10

Call address programming for 2-4 users and additional external unit

1

2

 Take note of the DIP-switch settings.

example:

3

4

NOTE Fig. 3 - On the DIP-switch, set the code corresponding to the function you want to program as shown in the table on page 11.

5

6

Reset the configuration of the DIP-switches of S1

Code 1 2 4 8 16 32
254

Dip-Switch ON 1 2 3 4 5 6
2,3,4,5,6,7,8

Function button 1 enabled with call address 1 (default) buttons 1-2 enabled with call addresses 1-2 buttons 1-2-3-4 enabled with call addresses 1-2-3-4
Porter with switching (secondary) Secondary porter Main porter Restore default
11

Programming a generic call address

1

2

 Take note of the DIP-switch settings.

example:

3

4

NOTE Fig. 3 - Set the user code on Dip Switches S1 (see table A on page 13).

1

3

2

4B

5

Reset the configuration of the DIP-switches of S1

12

Riser addresses

TAB. A

Code

Dip switch ON

Code

Dip switch ON

Code

Dip switch ON

Code

Dip switch ON

Code

Dip switch ON

Code

Dip switch ON

Code

Dip switch ON

Code

Dip switch ON

1

1

31

1,2,3,4,5

61

1,3,4,5,6

91

1,2,4,5,7

121

1,4,5,6,7

151

1,2,3,5,8

181

1,3,5,6,8

211 1,2,5,7,8

2

2

32

6

62

2,3,4,5,6

92

3,4,5,7

122

2,4,5,6,7

152

4,5,8

182

2,3,5,6,8

212

3,5,7,8

3

1,2

33

1,6

63 1,2,3,4,5,6 93

1,3,4,5,7

123 1,2,4,5,6,7 153

1,4,5,8

183 1,2,3,5,6,8 213 1,3,5,7,8

4

3

34

2,6

64

7

94

2,3,4,5,7

124

3,4,5,6,7

154

2,4,5,8

184

4,5,6,8

214 2,3,5,7,8

5

1,3

35

1,2,6

65

1,7

95

1,2,3,4,5,7 125 1,3,4,5,6,7 155

1,2,4,5,8

185

1,4,5,6,8

215 1,2,3,5,7,8

6

2,3

36

3,6

66

2,7

96

6,7

126 2,3,4,5,6,7 156

3,4,5,8

186

2,4,5,6,8

216

4,5,7,8

7

1,2,3

37

1,3,6

67

1,2,7

97

1,6,7

127 1,2,3,4,5,6,7 157

1,3,4,5,8

187 1,2,4,5,6,8 217 1,4,5,7,8

8

4

38

2,3,6

68

3,7

98

2,6,7

128

8

158

2,3,4,5,8

188

3,4,5,6,8

218 2,4,5,7,8

9

1,4

39

1,2,3,6

69

1,3,7

99

1,2,6,7

129

1,8

159 1,2,3,4,5,8 189 1,3,4,5,6,8 219 1,2,4,5,7,8

10

2,4

40

4,6

70

2,3,7

100

3,6,7

130

2,8

160

6,8

190 2,3,4,5,6,8 220 3,4,5,7,8

11

1,2,4

41

1,4,6

71

1,2,3,7

101

1,3,6,7

131

1,2,8

161

1,6,8

191 1,2,3,4,5,6,8 221 1,3,4,5,7,8

12

3,4

42

2,4,6

72

4,7

102

2,3,6,7

132

3,8

162

2,6,8

192

7,8

222 2,3,4,5,7,8

13

1,3,4

43

1,2,4,6

73

1,4,7

103

1,2,3,6,7

133

1,3,8

163

1,2,6,8

193

1,7,8

223 1,2,3,4,5,7,8

14

2,3,4

44

3,4,6

74

2,4,7

104

4,6,7

134

2,3,8

164

3,6,8

194

2,7,8

224

6,7,8

15

1,2,3,4

45

1,3,4,6

75

1,2,4,7

105

1,4,6,7

135

1,2,3,8

165

1,3,6,8

195

1,2,7,8

225

1,6,7,8

16

5

46

2,3,4,6

76

3,4,7

106

2,4,6,7

136

4,8

166

2,3,6,8

196

3,7,8

226

2,6,7,8

17

1,5

47

1,2,3,4,6

77

1,3,4,7

107

1,2,4,6,7

137

1,4,8

167

1,2,3,6,8

197

1,3,7,8

227 1,2,6,7,8

18

2,5

48

5,6

78

2,3,4,7

108

3,4,6,7

138

2,4,8

168

4,6,8

198

2,3,7,8

228

3,6,7,8

19

1,2,5

49

1,5,6

79

1,2,3,4,7

109

1,3,4,6,7

139

1,2,4,8

169

1,4,6,8

199

1,2,3,7,8

229 1,3,6,7,8

20

3,5

50

2,5,6

80

5,7

110

2,3,4,6,7

140

3,4,8

170

2,4,6,8

200

4,7,8

230 2,3,6,7,8

21

1,3,5

51

1,2,5,6

81

1,5,7

111 1,2,3,4,6,7 141

1,3,4,8

171

1,2,4,6,8

201

1,4,7,8

231 1,2,3,6,7,8

22

2,3,5

52

3,5,6

82

2,5,7

112

5,67

142

2,3,4,8

172

3,4,6,8

202

2,4,7,8

232

4,6,7,8

23

1,2,3,5

53

1,3,5,6

83

1,2,5,7

113

1,5,6,7

143

1,2,3,4,8

173

1,3,4,6,8

203

1,2,4,7,8

233 1,4,6,7,8

24

4,5

54

2,3,5,6

84

3,5,7

114

2,5,6,7

144

5,8

174

2,3,4,6,8

204

3,4,7,8

234 2,4,6,7,8

25

1,4,5

55

1,2,3,5,6

85

1,3,5,7

115

1,2,5,6,7

145

1,5,8

175 1,2,3,4,6,8 205

1,3,4,7,8

235 1,2,4,6,7,8

26

2,4,5

56

4,5,6

86

2,3,5,7

116

3,5,6,7

146

2,5,8

176

5,6,8

206

2,3,4,7,8

236 3,4,6,7,8

27

1,2,4,5

57

1,4,5,6

87

1,2,3,5,7

117

1,3,5,6,7

147

1,2,5,8

177

1,5,6,8

207 1,2,3,4,7,8 237 1,3,4,6,7,8

28

3,4,5

58

2,4,5,6

88

4,5,7

118

2,3,5,6,7

148

3,5,8

178

2,5,6,8

208

5,7,8

238 2,3,4,6,7,8

29

1,3,4,5

59

1,2,4,5,6

89

1,4,5,7

119 1,2,3,5,6,7 149

1,3,5,8

179

1,2,5,6,8

209

1,5,7,8

239 1,2,3,4,6,7,8

30

2,3,4,5

60

3,4,5,6

90

2,4,5,7

120

4,5,6,7

150

2,3,5,8

180

3,5,6,8

210

2,5,7,8

240

5,6,7,8

13

Description of Monitor Art. 6721W

7 8

2

1

9

3

10

4

11 12 6

13

5

1

2

1. Brightness control ff To increase the value, turn clockwise
2. Loudspeaker volume control ff To increase the value, turn clockwise
3. 4.3''LCD colour screen 4. Call volume adjustment (high - medium - low) 5. Soft-touch keys 6. Speaker and audio activation key 7. S1 Micro-switches for user code setting (see table on page 13) 8. S2 Micro-switches for programming keys and functions
DIP 1-2-3-4 for key function programming DIP 5-6 access to programming DIP 7 for power supply voltage management (see diagrams and variants on page 29) default = ON DIP 8: ON secondary monitor OFF main monitor (default)

A maximum of 1 main monitor can be set

9. Factory setting - DO NOT CHANGE! 10. Factory setting - DO NOT CHANGE! 11. CV 5 Video closing jumper 12. Pin for securing terminal block 13. Space for housing additional keys (Art. 6734W)

Terminal block for system connection LL Bus line connection terminals CFP1 CFP2 Outside door call input

14

Soft-touch key description
ff Press the desired key once to activate the function associated with it Wait for approximately 1 sec. before pressing the same key again. Pressing the same key several times in quick succession will cancel the command.
Lock-release key Key 1 Actuator function (programmable) Key 2 Self-ignition function (programmable)
Privacy key Additional keys (programmable)
KIT with additional keysi Art. 6734W sold separately Audio activation key
Indicator LED description
Lock-release LED slow flashing: door open; 1 flash after pressing: door opening confirmation continuous flashing: call in progress.
Privacy LED (red) steady: privacy function enabled 3 flashes (every 5 sec.): doctor function enabled continuous flashing: device in programming mode 4 flashes: system engaged
LED AUDIO (6) steady (with call): audio activated steady (idle): automatic answer activated continuous flashing: incoming call
15

Installation
115 mm

optional fixing

160 mm

1A

1B

1C

2

3

4

1

5

2

6

16

Removing / Fitting the terminal

2

1

1

3

Fitting upgrade KIT Art. 6734W

2 1
3
1

2

,-.' ,-.$ +
+

1 1
2

2

4

5

1

2
CFP1 CFP2 L L
3
(to remove)
3
2 2 1
6

7

2

8

17

Operation
Answer incoming call

Press the soft-touch audio activation key to answer incoming call.

Activation/deactivation automatic answer mode

ff Press on the audio activation key for 10 sec

»» (ACTIVATION)

+ audio LED with FIXED ILLUMINATION

»» (DEACTIVATION) + audio LED OFF

Monitor configuration

Standard configuration for soft-touch keys

DIP 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
1

DIP S2

DIP 2 DIP 3

0

0

0

0

1

0

1

0

0

1

0

1

1

1

1

1

0

0

0

0

1

0

1

0

0

1

0

1

1

1

1

1

DIP 4 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1
1

P1
ACT NULL
INT ACT ACT INT
AI INTb NULL
K NULL NULL INTb
INT NULL

P2
AI AI AI NULL ACT ACT D INT NULL NULL K NULL AI INT NULL

ACT NULL

P3
NULL INT INTb
NULL ACT NULL
K AI D NULL NULL NULL INT INT NULL

Art. 6721W(/BM) + Art. 6734
P4
D INTb ACT NULL ACT NULL NULL INT
AI NULL ACT
K ACT INT NULL

P5
NULL D
NULL K
ACT INTb NULL NULL INTb
AI INT ACT D INT NULL

PROG

Standard configuration for DIP switches 1-2-3-4

ACT AI K D INT
INTb NULL
PROG
18

Legend
Lock- release
Actuator Self-ignition Guardian door-entry phone call Doctor General or selective programmable intercom - singlefamily call standard for KIT 8461 General or selective programmable intercom - two-family call standard for KIT 8461 No function or DO NOT use Programmed functions, see pages 19-23. In this Dip switch setting, the buttons control the programmed functions; the NON-programmed buttons control functions referred to on line 0000 (default).

Advanced monitor configuration
Warning
If the default settings (see table on page 18) do not reflect requirements, the keys can be programmed differently by carrying out the steps below. At the end, set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting in the configuration tables on pages 19-23). In this dip switch setting, the keys control the programmed functions; the NON-programmed keys control functions referred to on line 0000 (see table on page 18). Restore the user code setting on S1, see table A on page 13.
Programming for intercom call
General intercom: function allowing calls to one or more internal units identified by the same call address as used by the external unit. Selective intercom: function allowing calls to one or more internal units identified by a dedicated call address (see table B, page 19) which is different from the one used by the external unit. General and selective intercoms CANNOT be used together on the same riser. Programming/deleting intercom address
Take note of the S2, S1 setting and restore it when programming is complete

1)

2)

3)

ProTgADrBaIm.PBmoiOnngp;FasgeFet c1o9de,
S1

S2 DIP S2 123456 000111

Cancellation
DIP ON
S1

S2 DIP S2 123456 111111

Selective intercom addresses
You must set the intercom address on all the riser's internal units. You can assign the same intercom address to a maximum of 3 internal units. For group calls, select the desired intercom codes simultaneously (max. 3).

TAB. B

Code

Dip switch ON

S1

Code

Dip switch ON

S1

1

1

5

5

2

2

6

6

3

3

7

7

4

4

8

8

19

Programming buttons for intercom call

DIP S2

DIP 1 DIP 2 DIP 3 DIP 4 P1

P2

0

0

0

0

1

0

0

0

0

1

0

0

INT

1

1

0

0

0

0

1

0

1

0

1

0

INT

0

1

1

0

1

1

1

0

INTb

INT

0

0

0

1

1

0

0

1

0

1

0

1

1

1

0

1

0

0

1

1

INTb

1

0

1

1

INT

INT

0

1

1

1

1

1

1

1

Art. 6721W(/BM) + Art. 6734

P3

P4

P5

INT INTb

INTb

DIP S1

INT

INT

INT

INT

PROG

INTb

ADDRESS

INTb

INT

INT

Example 1 - General intercom on a monitor with user code 5, P3 programming = general internal call, P4 = general intercom with address 9
Example 2 - Selective intercom on a monitor with user code 1 and intercom address 1, P3 programming = selective intercom with address 2, P4 = selective intercom with address 3
1. Set S2 DIP switch 6 to the combination 01.
»» the privacy LED flashes.
S2 DIP 1 2 3 4 5 6 S2 000001
2. Refer to the table on page 20 and select a combination in which the intercom function (either INT or INTb) is listed for the keys you wish to program. E.g. 1: for P3= general internal call, set S2 DIP switches 1-2-3-4 to the combination 1000 or 0011 or 1011 (P3=INT), set S1 with address 5 in accordance with table A on page 13, go to point 3. E.g. 1: for P4= general intercom, set S2 DIP switches 1-2-3-4 to the combination 1110 or 1011 (P4=INT), set S1 with address 9 in accordance with table A on page 13, go to point 3. E.g. 2: for P3= single-family intercom, set S2 DIP switches 1-2-3-4 to the combination 1000 or 0011 or 1011 (P3=INT), set S1 with address 2 in accordance with table B on page 19, go to point 3. E.g. 2: for P4= selective intercom, set S2 DIP switches 1-2-3-4 to the combination 1110 or 1011 (P4=INT), set S1 with address 3 in accordance with table B on page 19, go to point 3.
3. Press and release the key to be associated with the function
»» the lock-release LED lights up.
»» a confirmation tone will sound.
4. To exit programming mode, set S2 DIP switches 5-6 to the combination 00
ff the privacy LED switches off
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the combination 1111. Restore the user code setting on S1, see table A on page 13.
20

Direct programming of intercom call Allows direct programming of intercom call via the internal units.  Requires 2 operators Step 1: enter programming mode Operator 1 and Operator 2 carry out the following procedures on 2 internal units: 1. Set S2 DIP switches 1-2 -3-4 to the combination 1111 2. Press the audio key 3. Press and hold the privacy and lock-release keys for 3 sec.
»» The internal unit emits 1 tone. »» The privacy LED flashes. »» The internal unit enters audio mode. »» At this point the 2 operators will be communicating with each other. Step 2: intercom call programming Operator 1: ff Press the key you want to program to call operator 2 (e.g. 2). »» The internal unit manned by operator 1 emits a confirmation tone. Operator 2: ff Press the key you want to program to call operator 1 (e.g. 1). »» The internal unit manned by operator 2 emits a confirmation tone. Operator 1/ Operator 2: ff Press the audio key. »» The internal unit emits 1 tone. »» Programming of the 2 internal units is now complete. To program another internal unit, move on to STEP 3. Step 3: programming other internal units Operator 1/ Operator 2: 1. Once the new station has been reached, carry out step 1 to begin communication 2. Repeat step 2
NOTE If a call is received during programming, it must be answered and the programming procedure resumed afterwards.
21

Programming keys for generic or coded actuator

DIP S2

DIP 1 DIP 2 DIP 3 DIP 4

0

0

0

0

1

0

0

0

0

1

0

0

1

1

0

0

0

0

1

0

1

0

1

0

0

1

1

0

1

1

1

0

0

0

0

1

1

0

0

1

0

1

0

1

1

1

0

1

0

0

1

1

1

0

1

1

0

1

1

1

1

1

1

1

P1 ACT
ACT ACT

P2

ACT ACT

ACT

Art. 6721W(/BM) + Art. 6734

P3

P4

P5

ACT

ACT ACT

ACT

ACT ACT

ACT

PROG

DIP S1 ADDRESS

Example: on a monitor with user code 5, P1 programming = generic actuator, P2 = coded actuator (code 125)
Take note of the DIP-switch settings
1. Set S2 DIP switch 6 to the combination 01. »» the privacy LED flashes.
S2 DIP 1 2 3 4 5 6 S2 000001
2. Refer to the table on page 22 and select a combination in which the actuator function (ACT) is listed for the keys you wish to program. E.g.: for P1= generic actuator, set S2 DIP switches 1-2-3-4 to the combination 0000 or 1100 or 0010 (P1=ACT), set S1 DIP switches to the combination 11111111, go to point 3. E.g.: for P2= coded actuator (code 125), set S2 DIP switches 1-2-3-4 to the combination 0010 or 1010 (P2=ACT), set S1 with address 125 in accordance with table A on page 13, go to point 3.
3. Press and release the key to be associated with the function. »» the lock-release LED lights up. »» a confirmation tone will sound.
4. To exit programming mode, set S2 DIP switches 5-6 to the combination 00. »» the privacy LED switches off.
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the combination 1111. Restore the user code setting on S1, see table A on page 13.

22

Programming buttons for other functions

DIP S2

DIP 1 DIP 2 DIP 3 DIP 4 P1

P2

0

0

0

0

AI

1

0

0

0

AI

0

1

0

0

AI

1

1

0

0

0

0

1

0

1

0

1

0

0

1

1

0

AI

D

1

1

1

0

0

0

0

1

1

0

0

1

K

0

1

0

1

K

1

1

0

1

0

0

1

1

AI

1

0

1

1

0

1

1

1

1

1

1

1

Art. 6721W(/BM) + Art. 6734

P3

P4

P5

D D

K

K

AI

D

AI

AI

K D

PROG

AI K D PROG

Legend Lock- release Self-ignition Guardian doorentry phone call Doctor Programmed functions

Example: on a monitor with user code 5, P1 programming = self-ignition, P2= Doctor. 1. Set S2 DIP switch 6 to the combination 01.
»» the privacy LED flashes. S2 DIP
1 2 3 4 5 6 S2 000001
2. Refer to the table on page 23 and select a combination in which the desired/necessary functions are listed for the keys you wish to program. E.g. 1: for P1= self-ignition, P2= Doctor, set S2 DIP switches 1-2-3-4 to the combination 0110 (P1=AI,P2=D).
3. Press and release the keys to which you wish to assign the functions »» the lock-release LED lights up. »» une tonalité de confirmation retentit.
4. To exit programming mode, set S2 DIP switches 5-6 to the combination 00 »» the privacy LED switches off.
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the combination 1111.
23

Programming range

Take note of the S2, S1 setting and restore it when programming is complete

Carry out steps 1 to 4

1)

2)

3)

Range minimum address
Range maximum address

S1
set code, TAB. A on page 13

S2 DIP 123456 000010
S2

Enable range Disable range

DIP OFF

Deleting the range

DIP ON
S1

S2 DIP 123456 111110
S2

2 sec

4) S2

Monitor ringtone selection
1. Press and hold for 6 sec. »» a confirmation tone will sound »» the privacy LED will flash to indicate "programming" mode.
 The procedure can only take place while the system is in standby; otherwise the privacy LED will flash 4 times to inform the user that the system is engaged
2. Press and release Once (1 confirmation tone is emitted) to change the ringtone for calls from the external unit. Twice (2 confirmation tones are emitted) to change the ringtone for calls from the switchboard. 3 times (3 confirmation tones are emitted) to change the ringtone for intercom calls made from the internal unit. 4 times (4 confirmation tones are emitted) to change the floor door call ringtone. Any further pressing of the key repeats the sequence described above.
3. Press and release to scroll through the various available ringtones in sequence. 4. Press to confirm selection of the last ringtone heard and to exit (at any time) change monitor ringtone mode.
»» one confirmation tone is emitted »» the privacy LED switches off 5. Repeat steps 1 to 4 to change the other ringtones.

24

Programming reset Factory settings: · Button functions for the S2 DIP switch 1-2-3-4 combination; · Intercom address absent; · Range function and min./max. addresses absent;
· RingtonDe rIePset.OFF
Take note of the S2, S1 setting and restore it when programming is complete

1)

2)

3)

DIP ON
S1

S2 DIP S2 123456 111111

5 sec

25

Operation
To make a call from an external unit
ff To send the call from an external unit, touch the button corresponding to the user you want to contact. If the system is not busy: on the external unit the caller illumination LED will light up, the LED will flash and the confirmation tone will sound. The video image from the external unit will appear automatically on the main internal monitor/s. The video image can be displayed on secondary monitors (without answering the call) by pressing button 2 (programmed by default for the self-ignition function). »» If the user responds to the call: the LED will illuminate on the external unit. »» If the user presses the lock-release control: the LED will illuminate on the external unit. If the system is busy: the led will flash and the external unit will emit the system busy tone.
When a call is made from the external unit, the monitor switched on will be the main door entry monitor. Any other secondary monitors in the same family unit will remain off. When responding to a call from the external unit using a secondary door entry monitor, the image is automatically displayed on the monitor (and the main door entry monitor is switched off). To display the image without activating audio communication with the external unit, press button 2 -self-ignition/video request.
Self-ignition
 Self-ignition is possible only when the system is in standby ff Press the self-ignition button (button 2 by default) to display on the monitor the image transmitted from the external unit.
Operation with additional internal units
GENERAL INTERNAL CALL General intercom: function allowing calls to one or more internal units identified by the same call address as used by the external unit. ff Press the programmed button to send the call
If the system is not busy: The receiver of the call can press the audio key (or pick up the handset) to communicate with the caller. Press the audio button again (or hang up the handset) to terminate the call. If the system is busy: the LED indicator light will flash for a few seconds (on Mini monitors the privacy LED will flash 4 times). A call from the external unit always takes priority over an intercom communication. In this case, users who are already speaking will hear a tone similar to the ringtone, if the call is addressed to them, or otherwise a triple signalling tone will sound and the video image from the external unit from which the call was made will appear (in the case of a main monitor). ff Press the audio button twice (or hang up the handset and pick it up again) to terminate the call in progress or establish a communication with the external unit. SELECTIVE INTERCOM Selective intercom: function allowing calls to one or more internal units identified by a dedicated call address (see table B, page 19), which is different to the call address used for external unit calls. MAIN/SECONDARY MONITORS The KIT can manage up to a maximum of 4 door entry monitors or door-entry phones for each call button, including a maximum of 1 main door entry monitor.
Operation with additional external units
Consult page 11 onwards for programming information. · External unit (Porter) with switching (secondary): default function to be used also in systems with switching device Art.
1404 (for installations with 3 or more entrances) (see diagrams MNVK/017QC, MNVK/017CQC). · Secondary external unit (Porter): function to be used in systems with switching device Art. 1405 and 2 external units (see
diagram MNVK/017AQC). · Main external unit (Porter): function to be used in systems with switching device Art. 1405 and 2 external units (see
diagram MNVK/017AQC).
26

OPERATION WITH SWITCHING DEVICE ART. 1404 (DEFAULT) In the configuration of Art. 1404, the MIN and MAX Dip switches define respectively the lowest and highest user codes which can be connected to the riser. For information on setting the desired values, refer to the table on page 13. Separate switching devices for different risers must manage code ranges which are not overlapping. The self-ignition function is only available for systems as depicted in diagram MNVK/017CQC (for each internal unit, it is possible to toggle between the external unit of the KIT and the main external unit). OPERATION WITH SWITCHING DEVICE ART. 1405
With the switching device Art. 1405 it is possible to install only 1 main external unit and 1 secondary external unit.
In "Main external unit" mode, lock release (or actuator) commands are only executed if the external unit is in call or self-ignition mode. The "door-open" function is always deactivated. In "Secondary external unit" mode, lock release (or actuator) commands are executed if the system is in standby mode or if the external unit is active. If the system is in standby mode the first self-ignition command will activate the camera of the secondary external unit. Further commands will toggle between the external units, activating alternately the main external unit and the secondary external unit.
Additional door-entry phones Art. 2638

1

4

5

2

6

7

3

8

9

1

2

1. Privacy function indicator
2. Key button
3. Button P1 generic actuator / button for various uses present on terminal block (P1 C1)
4. 3-position ringtone/Privacy service selector: High position: Maximum ringtone volume. Middle position: Medium ringtone volume. Low position: Privacy service activation. (Privacy service means exclusion of the call ringtone from the external unit and switchboard; activation of the Privacy function is signalled by a red indicator appearing at the top righthand side).

5. Trimmer for adjusting the microphone volume
6. U2 DIP switch for setting user code
7. System connection terminals: L L bus line connection. CFP CFP Floor door call input. P1 C1 terminals for pushbutton P1 C.NO. 24V 100mA dedicated to various services (remove CV1 and CV2). S+ S- terminals for call repetition device
8. JP2 jumper for selecting the Switchboard call (position C) / Generic actuator (position A) function of button P1
9. CV1 CV2 jumpers to be removed in order to obtain a voltage free C. NO contact on button P1

27

Installation of door-entry phone Art. 2638

1

2

3

140-145 cm 115-125 cm

4

5

6

7

8

9

Programming of door-entry phone Art. 2638
Set the user code on Dip Switches U2 as indicated in the table on page 13.

28

Wiring diagrams
KIT 8461V: standard single-family system. Switching on/voltage check with system in standby

6721W 6721W/BM

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

L 110-240V
N
L2 L2 L1 L1
1209

30 Vdc 30 Vdc

*

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

* Local lock release button.
MNVK/039QC

29

KIT 8461V: expansion for two-family system

1216
LL

6721W 6721W/BM +6710

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

1214/2C

LL LM OUT OUT
LM L L IN IN

6721W 6721W/BM

1214/2C
LL OUT OUT LM
L L LM IN IN

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

L 110-240V
N
L2 L2 L1 L1
1209

SE
-

SE +

NC

NO

C

L

L

R T E

C O M

D O

4893

8461V

Additional monitors Art. 6721W/BM do not include a backplate. # To program the special function "buttons 1-2 enabled with call addresses 1-2" see page 11.
* Local lock release button.
30

MNVK/040QC

KIT 8461V: expansion for 4-user system

6721W 6721W/BM +6710

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

6721W 6721W/BM +6710

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

1216
LL

1214/2C

LL LM OUT OUT
LM L L IN IN

6721W 6721W/BM +6710

1214/2C
LL OUT OUT LM
L L LM IN IN

1214/2C
LL LM OUT OUT LM L L
IN IN
6721W 6721W/BM

1214/2C
LL OUT OUT LM
L L LM IN IN

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

Additional monitors Art. 6721W/BM do not include a backplate.
# To program the special function "buttons 1-2-3-4 enabled with call addresses 1-2-3-4" see page 11.
* Local lock release button.

L 110-240V
N
L2 L2 L1 L1
1209

*

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

#

8461V

MNVK/041QC 31

KIT 8461V: expansion with second external unit 4893 and switching device Art. 1405

6721W 6721W/BM

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

L1 L1 L2 L2 L

1209
N

110-240V

LL MM

1405
LLLL SSP P

SE
-

SE +

NC NO

C

4893

L

L

R T E

C O M

D O

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

SLAVE

MAIN
8461V

# To program the special functions "Main external unit (Porter)" and "Secondary external unit (Porter)", see page 11. For further information regarding operating modes, please refer to Operation section, page 26.
* Local lock release button. ** N.C. contact for door open indication. *** Door open indication not available.

MNVK/017AQC 32

KIT 8461V: expansion with 3 external units 4893 and switching device Art. 1404

6721W 6721W/BM

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

MIN MAX

ON

ON

12345678 12345678

1404

L L L L LP LP M M S S IN OUT

JP1

A

B

MIN MAX

ON

ON

12345678 12345678

1404

L L L L LP LP M M S S IN OUT

JP1

A

B

L 110-240V
N
L2 L2 L1 L1
1209

L 110-240V
N
L2 L2 L1 L1
1209

L 110-240V
N
L2 L2 L1 L1
1209

*

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

*

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

*

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

8461V

* Local lock release button.
The function "External unit (Porter) with switching (secondary)" is active by default (see Operation section, page 26). The self-ignition and door open indication functions are not available.
MNVK/017QC 33

Wiring diagram for system with 2 single-family KITS KIT 8461V and main external unit Art. 4893

1216
LL
6721W 6721W/BM

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

1216
LL
6721W 6721W/BM

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

1214/2C
LL OUT OUT LM
L L LM IN IN

1214/2C
LL OUT OUT LM
L L LM IN IN

MIN MAX

ON

ON

12345678 12345678

1404

L L L L LP LP M M S S IN OUT

JP1

A

B

MIN MAX

ON

ON

12345678 12345678

1404

L L L L LP LP M M S S IN OUT

JP1

A

B

L 110-240V
N
L2 L2 L1 L1
1209

L 110-240V
N
L2 L2 L1 L1
1209

L 110-240V
N
L2 L2 L1 L1
1209

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

8461V

8461V

# To program the special function "buttons 1-2 enabled with call addresses 1-2" see page 11.
## To program the call address, see page 12 - 13.
* Local lock release button.
The function "External unit (Porter) with switching (secondary)" is active by default (see page 26). The door open indication function is not available. The self-ignition function is available (with toggle function between 2 external units)

MNVK/017CQC

34

KIT 8461V: additional actuator relay Art. 1256

6721W 6721W/BM

LL

CC F1F2 PP

ON

ON

12345678 12345678

S1

A S2

P

1 JP4
2

1256

JP3 21

N C

C

N O

L

JP2 21

L

~-

~
+

230V~

1200
12V~

1214/2C
LL OUT OUT LM
L L LM IN IN

12/24V AC/DC

L 110-240V
N
L2 L2 L1 L1
1209

# For further information see the respective manual.
* Local lock release button.

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

8461V

MNVK/EQC 35

KIT 8461V: additional remote camera module Art. 1409

6721W 6721W/BM

LL

CC F1F2 PP
ON

ON

12345678 12345678

S1

A S2

P

L 110-240V
N
L2 L2 L1 L1
1209

~ ~ L L L L

- OUT OUT IN IN

+

1409

I N A

G N D

V 1

S 1

V 2

S 2

V 3

S 3

ON 12345678

1200
230V~ 12V~

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

8461V
# To be powered separately. For the setting and operation of Art.1409 see the respective manual.
* Local lock release button.
36

MNVK/015QC

KIT 8461V: additional 2 secondary monitors in cascade connection

6721W 6721W/BM
1209

LL

CC F1F2 PP
ON

CV5 ON

12345678 12345678

S1

A S2

P

P

6721W 6721W/BM +6710

LL

CC F1F2 PP
ON

CV5 ON

12345678 12345678

S1

A S2

P

S

6721W 6721W/BM +6710

LL

CC F1F2 PP
ON

ON

12345678 12345678

S1

A S2

P

S

Additional monitors Art. 6721W/BM do not include a backplate.

MNVK/Q23

Connection diagram for two-family system with one main monitor and 2 secondary monitors (cascade connection)

1216
LL

6721W 6721W/BM

1214/2C
LL OUT OUT LM
L L LM IN IN

LL

CC F1F2 PP

CV5

ON

ON

12345678 12345678

S1

A S2

P

P

6721W 6721W/BM +6710

LL

CC F1F2 PP

CV5

ON

ON

12345678 12345678

S1

A S2

P

S

6721W 6721W/BM +6710

LL

CC F1F2 PP
ON

ON

12345678 12345678

S1

A S2

P

S

6721W 6721W/BM
1214/2C
LL OUT OUT LM L L LM IN IN

LL

CC F1F2 PP

CV5

ON

ON

12345678 12345678

S1

A S2

P

P

6721W 6721W/BM +6710

LL

CC F1F2 PP

CV5

ON

ON

12345678 12345678

S1

A S2

P

S

6721W 6721W/BM +6710

LL

CC F1F2 PP
ON

ON

12345678 12345678

S1

A S2

P

S

1209

Additional monitors Art. 6721W/BM do not include a backplate.

MNVK/Q21 37

Connection diagram for system with maximum expansion in branch connection for single call address

1216
LL

6721W 6721W/BM +6710

1214/2C
LL OUT OUT LM L L LM IN IN
6721W 6721W/BM

1214/2C
LL OUT OUT LM
L L LM IN IN

LL

CC F1F2 PP
ON

CV5 ON

12345678 12345678

S1

A S2

P

S

6721W 6721W/BM +6710

LL

CC F1F2 PP
ON

ON

12345678 12345678

S1

A S2

P

S

LL

CC F1F2 PP
ON

CV5 ON

12345678 12345678

S1

A S2

P

P

6721W 6721W/BM +6710

LL

CC F1F2 PP
ON

ON

12345678 12345678

S1

A S2

P

S

1209
Additional monitors Art. 6721W/BM do not include a backplate.

MNVK/Q22

Connection diagram for cascade connection from internal video unit of additional doorentry phones Art. 2610 and Art. 6228(B)(W)

CV5

CV5

6721W 6721W/BM

ON

ON

P

12345678 12345678

S1

A S2

P

1214/2C 1209

LL

CC F1F2 PP

6721W 6721W/BM +6710

ON

ON

S

12345678 12345678

S1

A S2

P

LL

CC F1F2 PP

L L 1216
LL OUT OUT LM
L L LM IN IN
1214/2C

Additional monitors Art. 6721W/BM do not include a backplate.

- L

L

C F P

C F P

PCSS 3 3+

ON
12345678 S1

2610
SW3 S2 S1

- L

L

C F P

C F P

SS +

ON
12345678 S1

6228B 6228W
SW1
S2 S1

MNVK/AAD

Connection diagram for branch connection from internal video unit of additional doorentry phones Art. 2610 and Art. 6228(B)(W)

6721W 6721W/BM

LL

CC F1F2 PP

ON 12345678

ON 12345678

S1

A S2

P

1214/2C 1209
38

LL OUT OUT LM
L L LM IN IN
1214/2C

- L

L

C F P

C F P

PCSS 3 3+

SW3

S2 S1

2610

- L

L

C F P

C F P

SS +

SW1

S2 S1

6228B 6228W

MNVK/AAE

Connection diagram for branch connection from riser of additional door-entry phones Art. 2628/2638 and Art. 6228(B)(W)
6721W 6721W/BM 1214/2C

1214/2C L L
OUT OUT LM
L L LM IN IN

- L

L

C F P

C F P

PCSS 3 3+

2628/ 2638

1214/2C L L
OUT OUT LM
L L LM IN IN

- L

L

C F P

C F P

SS +

6228B 6228W
SW1
S2 S1

1214/2C L L
OUT OUT LM L L LM IN IN
1209

- L

L

C F P

C F P

PCSS 2 2+

2610
SW3
S2 S1

MNVK/FC

Door open indication use variant

L 110-240V
N
L2 L2 L1 L1
1209

#

SE
-

SE +

NC NO

C

L

L

R T E

C O M

D O

4893

# active input closed for DOOR OPEN signal.

In systems with Art. 1405 the "door open indication" function can only be used on the secondary external unit. In systems with Art. 1404 the "door open indication" function cannot be used.
MNVK/DO
39

Variant with security door lock and additional power supply

12/24V AC/DC

* Local lock release button.

*

SE SE
-+

NC NO

C

L

L

R T E

C O M

D O

4893

SB2/SNPQ
Floor door call connection variant
If there are a number of door-entry phones or monitor brackets with the same user code, connect the CFP button to one only; all the devices will ring simultaneously.

L L CFP CFP

* 20 m MAX - Use screened cable for the connection and do not run cables near heavy inductive loads or power supply cables (230V / 400V).

Using the RC network for door lock filter on relay contacts

On contacts C. NO.
JP1 NC NO

On contacts C. NC.

JP1 NC NO

Disabled: clean contact

JP1 NC NO

NO C

NC

40

NO C

NC

NO

C NC

41

2nd edition 04/2016 code 2G40001601

www.comelitgroup.com
Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy


Adobe PDF Library 15.0 Adobe InDesign CC 2015 (Macintosh)