600W Portable Power Station
Read this user manual carefully before using the product to ensure complete understanding and correct usage. Keep this manual for future reference. Improper use may cause serious injury, product damage, or property loss. By using this product, you acknowledge, approve, and accept all terms and content herein. OUPES is not liable for any loss caused by user's failure to comply with this User Manual.
OUPES reserves the right to final interpretation of this document and related materials, in compliance with laws and regulations. This document is subject to changes, updates, revisions, or termination without prior notice. Visit the official website for the latest product information.
The OUPES EXODUS 600 package includes the following items:
Category | Parameter | Value |
---|---|---|
AC Output | Rated Voltage | 100~120Vac |
Rated Power | 600W | |
Peak Power | 1200W | |
Frequency | 60Hz | |
DC 12V & Car Lighter Output | Rated Voltage | 12.8V |
Rated Current | 10A | |
USB-A Output | 5V/3A; 9V/2A; 12V/1.5A [18W Max] | |
USB-C Output | 5V/3A; 9V/2A; 12V/1.5A [18W Max] |
Category | Parameter | Value |
---|---|---|
AC Charge Input | 90-140Va.c 2.5A 50/60Hz 300W Max | |
PV Input | 15~35Vd.c MPPT:15-35V/12A 240W Max |
Parameter | Value |
---|---|
Rated Capacity | 256Wh |
Rated Voltage | 12.8 Vdc |
Battery Type | LiFePO4 |
Parameter | Value |
---|---|
IP Grade | IP21 |
Working Temperature | 0~40°C |
Dimension | 240*185*152.5mm |
Net Weight | 3.7KG |
The OUPES EXODUS 600 features various ports and controls:
The LCD screen provides real-time information about the power station's status:
The LCD battery capacity circle indicates the battery level, divided into five sections (20%-100%). When in use, the LCD display automatically wakes up. During discharge, capacity segments disappear, showing remaining capacity. When charging, the battery capacity circle flashes clockwise, indicating active charging. The number on the right displays real-time input power. Upon full charge, all segments illuminate and stabilize. Unplug the charger after charging is complete.
To turn the main power on or off, press and hold the power button for 3 seconds. When turning on, all icons will light up for a screen check. Release when 'ON' appears, and the LED light circle around the button will show a breathing light. To turn off, press and hold until 'OFF' appears, and the LCD display turns off.
With the main power button on, lightly press the switch button of each functional area (e.g., AC output, DC output). Corresponding icons on the LCD screen will light up, indicating the function is active and ready for use. Press the button again to turn off the function, and its icon will disappear from the LCD screen.
Use the standard AC charging cable to charge the device. Connect it to the AC input port and a wall outlet. The input power reading will appear on the screen, and the device will begin charging. It supports up to 300W fast charging and can fully charge in approximately 0.8 hours.
Insert and connect an optional 100W or 240W solar panel charging output port to the 7909 charging port on the product. The energy bar on the screen will rotate, input power will display, and the product will enter the charging state.
When powered on, this device supports the EPS (Emergency Power Backup) function. When the AC charging cable is connected to the power grid and the AC input port of this product, electrical appliances can use the AC output port of this product. In this mode, AC power comes from the power grid, not the battery. If the power grid suddenly cuts off, the product can automatically switch to battery power supply mode within 20ms.
This function is a non-professional UPS function and does not support 0ms switching. Do not connect it to equipment requiring uninterrupted power supply (such as data servers and workstations) without prior testing for compatibility. It is recommended to use only one device at a time. The operating power of the device should not exceed 600W (input + output). If the load and charging reach 600W, an overload report and output shutdown will occur after a one-minute delay. If it exceeds 600W, the output will shut down after a one-second delay. Avoid using multiple devices simultaneously to prevent triggering overload protection. OUPES will not bear responsibility if the device fails to operate normally or data is lost due to failure to follow instructions.
If the AC input current continuously exceeds 10A, the AC input overload protector fuse will blow to protect the device. After confirming no fault with the product, replace the fuse (found in the accessory bag) in the AC input overload protector to resume charging.
This product uses high-quality lithium iron phosphate (LiFePO4) batteries.
The AC output port has a rated power of 600W and a peak power of 1200W. It can power most household appliances. However, it is recommended to confirm the appliance's power before use and ensure the sum of all load devices' power is less than the rated power.
The LCD screen displays the battery life. For devices with stable power consumption, the runtime can be estimated based on this time.
When charging, the LCD screen displays the remaining charging time. The power indicator circle outside the battery power percentage will rotate circularly, and the input power will be displayed.
Use a dry, soft, clean cloth or paper towel to wipe the product.
Turn off the product and store it in a dry, ventilated place at room temperature. Do not place it near water or fire sources. For long-term storage, charge and discharge the battery every three months (discharge to 0%, fully charge, then discharge to 60%). Products not charged or discharged for more than 6 months will not be covered by warranty.
No, it cannot.
The capacity in the user manual is the rated capacity of the battery pack. Due to efficiency loss during charging and discharging, the actual output capacity will be lower than the specified capacity.
Fault Code | Fault Information | Status | Remarks |
---|---|---|---|
E00 | AC output short circuit protection | AC icon flashing, no output | Press the AC output power on/off button for recovery. |
E01 | Output overload protection | AC icon flashing, no output | The function icon indicates the overloaded path. Overload protection requires manual recovery. UPS function is overloaded at 600W for 1 second. |
E02 | AC Battery low voltage protection | Corresponding function icon flashes, corresponding port has no output. | Battery capacity below 20%, load ≤300W. Restart the corresponding function button to restore function and charge in time. |
E03 | AC output over-voltage and low voltage protection | AC icon flashing, no output | Need to manually press the AC switch to restore. |
E04 | Abnormal AC input frequency | AC icon flashing, no output | Automatically recovers after frequency returns to normal. |
E05 | High and low bus voltage, over-current | AC icon flashing, no output at all ports | Need to manually press the AC switch to restore. |
E06 | Inverter over-temperature | AC icon with up arrow flashing, no output at all ports | Automatically resumes after temperature returns to normal. |
E07 | Inverter low temperature | AC icon with down arrow flashing, no output at all ports | Automatically resumes after temperature returns to normal. |
E08 | Cigarette lighter port overload | DC icon flashing, no output at all ports | Need to manually press the DC switch to restore. |
E09 | System overload | AC icon flashes, AC function turned off, DC output normal. AC > 600VA or AC+DC > 600W. | Need to manually press the AC power button to restore. |
E11 | Hardware bias | E11 code flashing, no output at all ports | Manually turn off the main power and then restart. |
E12 | Cigarette lighter port short circuit | DC icon flashing, no output at all ports | Need to manually press the DC power button to restore. |
N/A | Charging over-temperature protection and charging low-temperature protection | No input, white energy circle rotates normally | Automatically resumes after temperature returns to normal. |
N/A | PV input over-voltage | No input | PV charging voltage <35V, automatically resumes after voltage returns to normal. |
![]() |
OUPES Exodus 600 Portable Power Station User Manual User manual for the OUPES Exodus 600, a 600W portable power station with a 256Wh capacity. Learn about its features, specifications, operation, charging methods, and troubleshooting. |
![]() |
OUPES Exodus 600 Plus Portable Power Station User Manual Comprehensive user manual for the OUPES Exodus 600 Plus portable power station, detailing its features, specifications, operation, charging methods, troubleshooting, and maintenance for optimal use. |
![]() |
OUPES Exodus 2400 Portable Power Station User Manual - 2400W, LiFePO4 Battery, APP Control Official user manual for the OUPES Exodus 2400 Portable Power Station (PW-S024). Learn about its 2400W output, LiFePO4 battery, APP control, safety, charging, and troubleshooting. Get detailed specifications and usage instructions. |
![]() |
OUPES Exodus 1500 Portable Power Station User Manual Comprehensive user manual for the OUPES Exodus 1500 Portable Power Station, covering specifications, functions, charging methods, troubleshooting, and maintenance. |
![]() |
OUPES EXODUS 600 PLUS Portable Power Station User Manual Comprehensive user manual for the OUPES EXODUS 600 PLUS 600W Portable Power Station, covering specifications, operation, charging methods (AC, solar), EPS function, troubleshooting, and maintenance. |
![]() |
OUPES Exodus 2400 Portable Power Station User Manual Comprehensive user manual for the OUPES Exodus 2400 Portable Power Station, detailing specifications, functions, charging methods, troubleshooting, and maintenance. |
![]() |
OUPES 1200W Portable Power Station User Manual Comprehensive user manual for the OUPES 1200W Portable Power Station, detailing its features, operation, charging methods, technical specifications, and troubleshooting for reliable portable power. |
![]() |
OUPES Mega 3 Portable Power Station User Manual | 3600W 3072Wh Comprehensive user manual for the OUPES Mega 3 Home Backup & Portable Power Station. Learn how to safely operate, charge, and maintain your 3600W, 3072Wh power station for reliable backup power. |