Read this user manual carefully before using the product to ensure complete understanding and correct usage. Keep this manual for future reference. Improper use may cause serious injury, product damage, or property loss. By using this product, you acknowledge, approve, and accept all terms and content herein. OUPES is not liable for any loss caused by user's failure to comply with this User Manual.

OUPES reserves the right to final interpretation of this document and related materials, in compliance with laws and regulations. This document is subject to changes, updates, revisions, or termination without prior notice. Visit the official website for the latest product information.

What's in the Box

The OUPES EXODUS 600 package includes the following items:

Product Description

Parameter Specifications

Output Technical Parameters

CategoryParameterValue
AC OutputRated Voltage100~120Vac
Rated Power600W
Peak Power1200W
Frequency60Hz
DC 12V & Car Lighter OutputRated Voltage12.8V
Rated Current10A
USB-A Output5V/3A; 9V/2A; 12V/1.5A [18W Max]
USB-C Output5V/3A; 9V/2A; 12V/1.5A [18W Max]

Input

CategoryParameterValue
AC Charge Input90-140Va.c 2.5A 50/60Hz 300W Max
PV Input15~35Vd.c MPPT:15-35V/12A 240W Max

Battery

ParameterValue
Rated Capacity256Wh
Rated Voltage12.8 Vdc
Battery TypeLiFePO4

Common Information

ParameterValue
IP GradeIP21
Working Temperature0~40°C
Dimension240*185*152.5mm
Net Weight3.7KG

Function Description

The OUPES EXODUS 600 features various ports and controls:

  1. Main Power On/Off Switch: Controls the overall power of the unit.
  2. USB-A Output: Standard USB ports for charging devices.
  3. AC Output Power On/Off Switch: Activates or deactivates the AC output ports.
  4. AC Output Port: Standard AC outlets for powering appliances.
  5. LCD Screen: Displays operational status, battery level, and other information.
  6. Car Charger Output Port: 12V DC output for car accessories.
  7. USB-C Output: USB Type-C port for charging compatible devices.
  8. DC Output Power On/Off Switch: Activates or deactivates the DC output ports (including USB and car charger).
  9. AC Input Overcurrent Protection: A fuse that protects against excessive AC input current.
  10. PV Input: Port for connecting solar panels.
  11. AC Input: Port for connecting the AC charging cable.

LCD Screen Description

The LCD screen provides real-time information about the power station's status:

Instructions for Use

The LCD battery capacity circle indicates the battery level, divided into five sections (20%-100%). When in use, the LCD display automatically wakes up. During discharge, capacity segments disappear, showing remaining capacity. When charging, the battery capacity circle flashes clockwise, indicating active charging. The number on the right displays real-time input power. Upon full charge, all segments illuminate and stabilize. Unplug the charger after charging is complete.

To turn the main power on or off, press and hold the power button for 3 seconds. When turning on, all icons will light up for a screen check. Release when 'ON' appears, and the LED light circle around the button will show a breathing light. To turn off, press and hold until 'OFF' appears, and the LCD display turns off.

With the main power button on, lightly press the switch button of each functional area (e.g., AC output, DC output). Corresponding icons on the LCD screen will light up, indicating the function is active and ready for use. Press the button again to turn off the function, and its icon will disappear from the LCD screen.

Notice:

  1. A short press of the main power button after the product is turned on will turn off the LCD screen, but the product will not shut down.
  2. If the product is not operated within 5 minutes, it will enter sleep mode, and the LCD screen will automatically turn off. The screen will light up again upon operation.
  3. When not loaded, the default standby time is 4 hours, after which the product will automatically shut down.

Recharge Methods

AC Charging

Use the standard AC charging cable to charge the device. Connect it to the AC input port and a wall outlet. The input power reading will appear on the screen, and the device will begin charging. It supports up to 300W fast charging and can fully charge in approximately 0.8 hours.

Solar Charging

Insert and connect an optional 100W or 240W solar panel charging output port to the 7909 charging port on the product. The energy bar on the screen will rotate, input power will display, and the product will enter the charging state.

Notice:

  1. Keep the solar panel at a perpendicular angle to the sun's rays as much as possible for optimal solar energy conversion efficiency.
  2. Before connecting the solar panel, confirm that its output open circuit voltage specification is within 35V to prevent damage to the product.

Other Functions

EPS Function

When powered on, this device supports the EPS (Emergency Power Backup) function. When the AC charging cable is connected to the power grid and the AC input port of this product, electrical appliances can use the AC output port of this product. In this mode, AC power comes from the power grid, not the battery. If the power grid suddenly cuts off, the product can automatically switch to battery power supply mode within 20ms.

Notice:

This function is a non-professional UPS function and does not support 0ms switching. Do not connect it to equipment requiring uninterrupted power supply (such as data servers and workstations) without prior testing for compatibility. It is recommended to use only one device at a time. The operating power of the device should not exceed 600W (input + output). If the load and charging reach 600W, an overload report and output shutdown will occur after a one-minute delay. If it exceeds 600W, the output will shut down after a one-second delay. Avoid using multiple devices simultaneously to prevent triggering overload protection. OUPES will not bear responsibility if the device fails to operate normally or data is lost due to failure to follow instructions.

AC Input Overload Protection

If the AC input current continuously exceeds 10A, the AC input overload protector fuse will blow to protect the device. After confirming no fault with the product, replace the fuse (found in the accessory bag) in the AC input overload protector to resume charging.

FAQ

  1. What type of battery does the product use?

    This product uses high-quality lithium iron phosphate (LiFePO4) batteries.

  2. What equipment can be connected to the AC output port of the product?

    The AC output port has a rated power of 600W and a peak power of 1200W. It can power most household appliances. However, it is recommended to confirm the appliance's power before use and ensure the sum of all load devices' power is less than the rated power.

  3. How to know how long the product can provide power?

    The LCD screen displays the battery life. For devices with stable power consumption, the runtime can be estimated based on this time.

  4. How to tell if the product is charging?

    When charging, the LCD screen displays the remaining charging time. The power indicator circle outside the battery power percentage will rotate circularly, and the input power will be displayed.

  5. How to clean this product?

    Use a dry, soft, clean cloth or paper towel to wipe the product.

  6. How to store the product?

    Turn off the product and store it in a dry, ventilated place at room temperature. Do not place it near water or fire sources. For long-term storage, charge and discharge the battery every three months (discharge to 0%, fully charge, then discharge to 60%). Products not charged or discharged for more than 6 months will not be covered by warranty.

  7. Can this product be brought on board a plane?

    No, it cannot.

  8. Is the actual output capacity of the product consistent with the capacity specified in the user manual?

    The capacity in the user manual is the rated capacity of the battery pack. Due to efficiency loss during charging and discharging, the actual output capacity will be lower than the specified capacity.

Fault Code and Trouble Shooting

Fault CodeFault InformationStatusRemarks
E00AC output short circuit protectionAC icon flashing, no outputPress the AC output power on/off button for recovery.
E01Output overload protectionAC icon flashing, no outputThe function icon indicates the overloaded path. Overload protection requires manual recovery. UPS function is overloaded at 600W for 1 second.
E02AC Battery low voltage protectionCorresponding function icon flashes, corresponding port has no output.Battery capacity below 20%, load ≤300W. Restart the corresponding function button to restore function and charge in time.
E03AC output over-voltage and low voltage protectionAC icon flashing, no outputNeed to manually press the AC switch to restore.
E04Abnormal AC input frequencyAC icon flashing, no outputAutomatically recovers after frequency returns to normal.
E05High and low bus voltage, over-currentAC icon flashing, no output at all portsNeed to manually press the AC switch to restore.
E06Inverter over-temperatureAC icon with up arrow flashing, no output at all portsAutomatically resumes after temperature returns to normal.
E07Inverter low temperatureAC icon with down arrow flashing, no output at all portsAutomatically resumes after temperature returns to normal.
E08Cigarette lighter port overloadDC icon flashing, no output at all portsNeed to manually press the DC switch to restore.
E09System overloadAC icon flashes, AC function turned off, DC output normal. AC > 600VA or AC+DC > 600W.Need to manually press the AC power button to restore.
E11Hardware biasE11 code flashing, no output at all portsManually turn off the main power and then restart.
E12Cigarette lighter port short circuitDC icon flashing, no output at all portsNeed to manually press the DC power button to restore.
N/ACharging over-temperature protection and charging low-temperature protectionNo input, white energy circle rotates normallyAutomatically resumes after temperature returns to normal.
N/APV input over-voltageNo inputPV charging voltage <35V, automatically resumes after voltage returns to normal.

Storage and Maintenance

  1. Store the product away from water sources, heat sources, and metal objects.
  2. To extend battery service life, use or store the product in an environment of 20°C to 30°C.
  3. For long-term storage, charge and discharge the product once every 3 months (first discharge to 0%, then fully charge, then discharge to 60% for long-term storage). Products not charged or discharged for more than 6 months will not be covered by warranty.
  4. For safety, do not store this product in an environment above 45°C or below -10°C for a long time.
  5. If the product is seriously low on power and idle for too long, it will enter deep sleep mode and must be charged before reuse.

PDF preview unavailable. Download the PDF instead.

Exodus 600 ?v=1714103280 Adobe PDF library 10.01 Adobe Illustrator CC 23.0 (Windows)

Related Documents

Preview OUPES Exodus 600 Portable Power Station User Manual
User manual for the OUPES Exodus 600, a 600W portable power station with a 256Wh capacity. Learn about its features, specifications, operation, charging methods, and troubleshooting.
Preview OUPES Exodus 600 Plus Portable Power Station User Manual
Comprehensive user manual for the OUPES Exodus 600 Plus portable power station, detailing its features, specifications, operation, charging methods, troubleshooting, and maintenance for optimal use.
Preview OUPES Exodus 2400 Portable Power Station User Manual - 2400W, LiFePO4 Battery, APP Control
Official user manual for the OUPES Exodus 2400 Portable Power Station (PW-S024). Learn about its 2400W output, LiFePO4 battery, APP control, safety, charging, and troubleshooting. Get detailed specifications and usage instructions.
Preview OUPES Exodus 1500 Portable Power Station User Manual
Comprehensive user manual for the OUPES Exodus 1500 Portable Power Station, covering specifications, functions, charging methods, troubleshooting, and maintenance.
Preview OUPES EXODUS 600 PLUS Portable Power Station User Manual
Comprehensive user manual for the OUPES EXODUS 600 PLUS 600W Portable Power Station, covering specifications, operation, charging methods (AC, solar), EPS function, troubleshooting, and maintenance.
Preview OUPES Exodus 2400 Portable Power Station User Manual
Comprehensive user manual for the OUPES Exodus 2400 Portable Power Station, detailing specifications, functions, charging methods, troubleshooting, and maintenance.
Preview OUPES 1200W Portable Power Station User Manual
Comprehensive user manual for the OUPES 1200W Portable Power Station, detailing its features, operation, charging methods, technical specifications, and troubleshooting for reliable portable power.
Preview OUPES Mega 3 Portable Power Station User Manual | 3600W 3072Wh
Comprehensive user manual for the OUPES Mega 3 Home Backup & Portable Power Station. Learn how to safely operate, charge, and maintain your 3600W, 3072Wh power station for reliable backup power.