OUPES EXODUS 600 PLUS 600W Portable Power Station User Manual

Disclaimer

Users must carefully read this user manual before using the product to ensure complete understanding and correct usage. After reading, keep it for future reference. Improper use may cause serious injury or product/property damage. By using this product, users are deemed to understand, approve, and accept all terms and content herein. The Company is not liable for losses caused by failure to comply with this User Manual.

In compliance with laws and regulations, the Company reserves the right to final interpretation of this document and all related documents. This document is subject to changes, updates, revisions, or termination without prior notice. Visit the official website for the latest product information.

What's in the Box

The OUPES EXODUS 600 PLUS package includes:

Product Description

Parameter Specifications

Output Technical Parameters

Value
AC OutputRated Voltage100~120Vac
Rated Power600W
Peak Power1200W
Frequency60Hz
DC 12V & Car Lighter OutputRated Voltage12.8V
Rated Current10A
USB-A Output5V/3A; 9V/2A; 12V/1.5A [18W Max]
USB-C Output5V/3A; 9V/2A; 12V/1.5A [18W Max]

Input

Value
AC Charge Input90-140Va.c 2.5A 50/60Hz 300W Max
PV Input15~35Vd.c MPPT:15-35V/12A 240W Max

Battery

Value
Rated Capacity512Wh
Rated Voltage12.8 Vdc
Battery TypeLiFePO4

Common Information

Value
IP GradeIP21
Working Temperature0~40°C
Dimension240*185*195.5mm
Net Weight5.6KG

Function Description

The OUPES EXODUS 600 PLUS features various ports and controls on its front and rear panels:

Front Panel:

  1. Main Power On/Off Switch: Controls the overall power of the unit.
  2. USB-A Output: Standard USB Type-A ports for charging devices.
  3. AC Output Power On/Off Switch: Activates/deactivates the AC output ports.
  4. AC Output Port: Standard AC outlets (100-120V/600W).
  5. LCD Screen: Displays operational information such as battery level, input/output power, and alarms.
  6. Car Charger Output Port: A 12V/30A port for car charger compatible devices.
  7. USB-C Output: USB Type-C port for charging devices.
  8. DC Output Power On/Off Switch: Activates/deactivates the DC output ports (including car charger and USB).

Rear Panel:

  1. AC Input Overcurrent Protection: A fuse for protecting against AC input overcurrent.
  2. PV Input: Port for connecting solar panels.
  3. AC Input: Port for connecting the AC charging cable from a wall outlet.

LCD Screen Description

The LCD screen provides real-time information about the power station's status:

Instructions for Use

The LCD battery capacity circle indicates the battery level, divided into five sections representing 20% increments. When in use, the LCD display automatically wakes up. During discharge, capacity segments disappear, showing remaining capacity. When charging, the battery capacity circle flashes clockwise, indicating active charging, and the real-time input power is displayed. Upon full charge, all segments illuminate and remain stable. Unplug the charger once charging is complete.

To turn the main power on or off, press and hold the main power button for 3 seconds. When turning on, all icons will light up for a screen check. Release the button when the screen shows 'ON'. A circle of LED lights around the button will illuminate with a breathing effect. When turning off, press and hold until the screen shows 'OFF', and the LCD display turns off.

With the main power button on, lightly press the switch button of each functional area (e.g., AC output, DC output). The corresponding function icons on the LCD screen will light up, indicating the function is active and ready for use. Tapping the button again will turn off the LCD icon and stop the function.

Notice:

  1. After the product is turned on, a short press of the main power button will turn off the LCD screen but the product will not shut down.
  2. If the product is not operated within 5 minutes, it will enter a sleep state, and the LCD screen will automatically turn off. The screen will light up again upon operation.
  3. When not loaded, the default standby time is 4 hours, after which the product will automatically shut down.

Recharge Methods

AC Charging

To charge the device using AC power, connect the standard AC charging cable to the AC input port on the power station and then to a wall outlet. The input power reading will appear on the screen, and the device will begin charging. The unit supports up to 300W fast charging and can be fully charged in approximately 1.8 hours.

Diagram description: A power station is shown connected via its AC input port to an AC charging cable, which is then plugged into a wall outlet.

Solar Charging

Insert and connect an optional 100W or 240W solar panel charging output port to the 7909 charging port on the product. The energy bar on the screen will start to rotate, the input power will be displayed, and the product will enter the charging state.

Diagram description: A power station is shown with its PV input port connected to a solar panel.

Notice:

  1. For highest solar energy conversion efficiency, keep the solar panel at a perpendicular angle to the sun's rays as much as possible.
  2. Before connecting a solar panel, confirm that its output open circuit voltage specification is within 35V to avoid product damage.

Other Functions

EPS Function

When powered on, this device supports the EPS (Emergency Power Backup) function. When the AC charging cable is connected to the power grid and the AC input port of this product, the electrical appliance can use the AC output port of this product. In this mode, the AC power comes from the power grid instead of the battery. If the power grid suddenly cuts off, this product can automatically switch to battery power supply mode within 20ms.

Diagram description: Three devices are shown: a power station, a power grid connection, and an external monitor. The power station is connected to both the power grid and the monitor, illustrating the power flow.

Notice:

This function is a non-professional UPS function and does not support 0ms switching. Do not connect it to equipment requiring uninterrupted power supply (such as data servers and workstations). Test compatibility multiple times before use. It is recommended to use only one device at a time. The operating power of the device should not exceed 600W (input + output). If the load and charging reach 600W, there will be a one-minute delay before an overload report and output shutdown. If it exceeds 600W, the output will shut down after a 1-second delay. Do not use multiple devices simultaneously to avoid triggering overload protection. The company will not bear responsibility if the device fails to operate normally or data is lost due to failure to follow instructions.

AC Input Overload Protection

If the AC input current abnormally exceeds 10A, the AC input overload protector fuse will blow to protect the device. After confirming no fault with the product, replace the fuse in the AC input overload protector (found in the accessory bag) to resume charging.

Diagram description: A power station's rear panel showing the AC input port with an overcurrent protector, pointing to a circular fuse.

FAQ

  1. What type of battery does the product use?

    This product uses high-quality lithium iron phosphate batteries (LiFePO4).

  2. What equipment can be connected to the AC output port of the product?

    The AC output port has a rated power of 600W and a peak power of 1200W. It can power most household appliances. However, it is recommended to confirm the appliance's power before use and ensure the sum of all load devices' power is less than the rated power.

  3. How to know how long the product can provide power?

    The LCD screen displays the battery life. For devices with stable power consumption, the remaining time can be estimated based on this display.

  4. How to tell if the product is charging?

    When charging, the LCD screen displays the remaining charging time. The power indicator circle outside the battery power percentage rotates in a circular motion, and the input power is displayed.

  5. How to clean this product?

    Use a dry, soft, clean cloth or paper towel to wipe this product.

  6. How to store the product?

    When storing, turn off the product and store it in a dry, ventilated place at room temperature. Do not place it near water or fire sources. For long-term storage, charge and discharge the battery every three months (first discharge to 0%, then fully charge, then discharge to 60% for long-term storage). Products not charged or discharged for more than 6 months will not be covered by warranty.

  7. Can this product be brought on board a plane?

    No, it cannot.

  8. Is the actual output capacity of the product consistent with the capacity specified in the user manual?

    The capacity indicated in the user manual is the rated capacity of the battery pack. Due to efficiency loss during charging and discharging, the actual output capacity will be lower than the specified capacity.

Fault Code and Trouble Shooting

Fault codeFault InformationStatusRemarks
E00AC output short circuit protectionAC icon flashing, no outputPress the AC output power on/off button for recovery.
E01Output overload protectionAC icon flashing, no outputThe function icon indicates the overloaded path. Overload protection requires manual recovery. The UPS function is overloaded at 600W for 1 second.
E02AC Battery low voltage protectionCorresponding function icon flashes, corresponding port has no output.Battery capacity below 20%, load ≤300W. Restart the corresponding function button to restore the function and charge in time.
E03AC output over-voltage and low voltage protectionAC icon flashing, no outputNeed to manually press the AC switch to restore.
E04Abnormal AC input frequencyAC icon flashing, no outputAutomatically recovers after frequency returns to normal.
E05High and low bus voltage, over-currentAC icon flashing, no output at all portsNeed to manually press the AC switch to restore.
E06Inverter over-temperatureAC icon with '+' and temperature symbol flashing, no output at all portsAutomatically resumes after temperature returns to normal.
E07Inverter low temperatureAC icon with '+' and snowflake symbol flashing, no output at all portsAutomatically resumes after temperature returns to normal.
E08Cigarette lighter port overloadDC icon flashing, no output at all portsNeed to manually press the DC switch to restore.
E09System overloadAC icon flashes, AC function is turned off, DC output is normal, AC is >600VA or AC+DC is >600WNeed to manually press the AC power button to restore.
E11Hardware biasE11 code flashing, no output at all portsManually turn off the main power and then restart.
E12Cigarette lighter port short circuitDC icon flashing, no output at all portsNeed to manually press the DC power button to restore.
Charging over-temperature protection and charging low-temperature protectionNo input, white energy circle rotates normallyAutomatically resumes after temperature returns to normal.
PV input over-voltageNo inputPV charging voltage <35V, automatically resumes after voltage returns to normal.

Maintenance

  1. Store the product away from water sources, heat sources, and metal objects.
  2. To extend battery service life, use or store this product in an environment of 20°C to 30°C.
  3. For long-term storage, charge and discharge the product every 3 months (first discharge to 0%, then fully charge, then discharge to 60% for long-term storage). Products not charged or discharged for more than 6 months will not be covered by warranty.
  4. For safety reasons, do not store this product in an environment above 45°C or below -10°C for a long time.
  5. If the product is seriously low on power and idle for too long, it will enter deep sleep mode and must be charged before use again.

PDF preview unavailable. Download the PDF instead.

Exodus 600 Plus ?v=1714103280 Adobe PDF library 15.00 Adobe Illustrator CC 23.0 (Windows)

Related Documents

Preview OUPES Exodus 600 Plus Portable Power Station User Manual
Comprehensive user manual for the OUPES Exodus 600 Plus portable power station, detailing its features, specifications, operation, charging methods, troubleshooting, and maintenance for optimal use.
Preview OUPES Exodus 1200 Portable Power Station User Manual
Comprehensive user manual for the OUPES Exodus 1200 Portable Power Station, detailing specifications, functions, charging methods, troubleshooting, and maintenance.
Preview OUPES Mega 2 2500W Portable Power Station User Manual
Comprehensive user manual for the OUPES Mega 2 2500W Portable Power Station, covering safety instructions, product specifications, usage guidance, recharge methods, troubleshooting, and compliance information.
Preview OUPES Mega 1 2000W Portable Power Station User Manual
User manual for the OUPES Mega 1 2000W Portable Power Station, covering specifications, safety instructions, usage, charging methods, troubleshooting, and compliance.
Preview OUPES MEGA 1 2000W Outdoor Power Station User Manual
Comprehensive user manual for the OUPES MEGA 1 2000W Outdoor Power Station, covering product specifications, functions, various charging methods (AC, solar, car, power pack, generator), emergency power supply (EPS), frequency switching, troubleshooting, and maintenance.
Preview OUPES Mega 5 4000W Portable Power Station User Manual
User manual for the OUPES Mega 5 portable power station, detailing its 4000W output, 5040Wh LiFePO4 battery, various charging methods, functions, troubleshooting, and maintenance. Optimized for accessibility and SEO.
Preview OUPES Titan 3 3600W Smart Generator User Manual
Comprehensive user manual for the OUPES Titan 3 3600W Smart Generator, covering specifications, operation, charging methods, troubleshooting, and maintenance. Learn how to use your generator safely and effectively.
Preview OUPES Mega 3 Portable Power Station User Manual
Comprehensive user manual for the OUPES Mega 3 3600W Portable Power Station, covering setup, operation, charging methods, troubleshooting, and maintenance.