Prestige Ventilation Inserts & Liners Use & Care Manual

Prestige Ventilation Inserts & Liners

Use & Care Manual

Intended for Residential Cooking Only

READ AND SAVE THESE INSTRUCTIONS

Models covered: UIB, UIBTF, CMUIB, UIM

Installer: Leave this manual with homeowner. Homeowner: Use and Care information inside.

Prestige America Ltd.
25 Riverside Dr. Suite 4
Pine Brook, NJ 07058

Important Safety Instructions

PRESTIGE® INSERTS ARE FOR RESIDENTIAL USE ONLY!

CAUTION: FOR GENERAL VENTILATION USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS.

  1. Use this unit only in the manner intended by the manufacturer. For questions, contact Prestige® at 800-358-8886.
  2. Before servicing or cleaning, switch power off at the service panel and lock it to prevent accidental activation. If the panel cannot be locked, attach a prominent warning device (e.g., a tag) to it.

WARNING: TO REDUCE THE RISK OF RANGE TOP GREASE FIRE, PLEASE OBSERVE THE FOLLOWING:

  1. Never leave surface units unattended at high settings. Boil-overs can cause smoking and may ignite. Heat oils slowly on low heat.
  2. Always turn the ventilation system ON five minutes prior to cooking to begin airflow.
  3. Clean ventilation filters frequently. DO NOT ALLOW GREASE TO ACCUMULATE ON FAN OR FILTER.
  4. Use proper pan size. Always use cookware appropriate for the size of the burner or element.

WARNING - IN THE EVENT OF RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:

  1. Smother flames with a close-fitting lid, cooking sheet, or other metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
  2. NEVER PICK UP A FLAMING PAN.
  3. MAKE SURE YOUR VENTILATION SYSTEM IS COMPLETELY TURNED OFF. DO NOT TURN HOOD ON TO TRY AND EVACUATE SMOKE.
  4. DO NOT USE WATER, including wet dishcloths or towels, as a violent steam explosion may result.
  5. Use an extinguisher only if:
    • You know you have a class ABC extinguisher and how to operate it.
    • The fire is small and contained where it started.
    • The fire department is being called.
    • You can fight the fire with your back to an exit.

Handling Precautions

  • Remove all rings, watches, belt buckles, jewelry, and clothing with metal buttons or snaps to prevent damage to the Insert.
  • DO NOT REMOVE INSERT FROM ITS ORIGINAL CARTON UNTIL YOU ARE READY TO INSTALL IT.
  • When ready to install, remove the insert from its carton and place it on a clean soft blanket.
  • Inspect the insert carefully for any damage or imperfections before installation. If damage exists, re-carton the insert and call your dealer IMMEDIATELY; do not install a damaged hood.
  • It is highly recommended to use rubber gloves to prevent scratches and provide a firm grip.
  • When removing the insert from the carton, locate the filters. Filters are not pre-installed; they are in a box marked "filters" inside the insert carton.
  • Internal blower inserts can be ducted to the top or rear. Check product guide for additional transitions, wall caps, and roof caps.
  • Duct size for units ending in 600 is 6" round; an optional transition model TRC8/6 should be used to increase duct size to 8" round for optimal performance.
  • Units with model numbers ending in 1200 require transition model TR6x15/10 (NOT INCLUDED AND SOLD SEPARATELY).
  • All Prestige® ventilation inserts have a variable speed blower switch and a light dimmer switch.
  • Inserts can be set up for ductless applications. See product guide for optional ductless conversion kits.

Important Ventilation Information Before You Begin

The desired installation height of the insert is at the user's discretion, however, a height of 30" to 36" above the cooking surface is recommended. Two persons are required to install the insert.

Before installing your insert, be sure to read the following!

Prestige® inserts are designed to utilize internal, in-line, or remote blowers. Other blowers CANNOT be substituted. Select the series best suited for your application. Units labeled "NB" are for use with in-line or remote blowers. Units labeled "600" or "1200" come with pre-installed 600 or 1200 CFM motors. Before installing ANY unit, inspect and test blowers to ensure no packing or obstructions remain and that blower(s) spin freely.

The custom hood frame must be sized to the shape and total weight of the insert assembly (See hood liner/insert dimension guide). Run power cable to the installation location. Stub out a 4-foot length of electrical cable behind the custom hood. DETERMINE WHETHER OR NOT THE USE OF A WALL SWITCH IS NEEDED. A 3" to 4" recess should be provided for a proper capture area. If the cooking product contains a grill (BBQ), a minimum of 6" additional capture area should be provided. The custom hood depth should be at least 19" minimum for common gas or electric cooktops. A 24" depth is for pro-style ranges, whether dual fuel or all gas. If the cooking appliance contains a grill (BBQ) or a high output wok or griddle, the use of an in-line blower or remote blower is highly recommended.

NOTE TO INSTALLER: To avoid damage not covered under warranty, ensure blowers are free from obstructions (packing and debris) prior to running. Test run blowers before finalizing installation. Check with the manufacturer before attempting to use other than Prestige® blower systems. Contact 800.358.8886 for technical information.

Cleaning and Maintenance

Ensure lights are cool before cleaning. The insert will not function properly if not cleaned and maintained regularly. Clean filters at least twice a month or every 24 hours of use by soaking them in soapy water and rinsing them in the dishwasher on a normal cycle. With filters removed, the interior can be cleaned of grease using soap and water. Burned-out halogen light bulbs are replaced like normal light bulbs; use the same type and wattage (replacement bulbs: Par 16, 60 watt, halogen 115 volt). Make it a habit to turn on the insert on low speed even when boiling water. Do not use abrasive or aggressive chemicals!

Check the outside end of the duct at least once a year. Ensure the back draft damper (sold separately) hinges are free of grease and move easily. If an insect screen is installed at the duct termination, ensure it is not broken or dislocated. Filters are dishwasher safe or can be hand-washed with warm soapy water.

Cleaning Steps:

  1. Turn the fan and lights off.
  2. Push the filters towards the top and extract downward.
  3. When placing filters into the dishwasher, ensure they are angled.
  4. Drain water and let each filter dry before replacing.

Diagram Description: A visual shows a range hood with arrows pointing to two filter locations, labeled "Filter".

Accessories Sold Separately

  • In-line blowers: IL600, IL1200, IL1600
  • Remote blowers: RB1000, RB1200, RB1600, RB2000
  • Transitions: TR6x15/8, TR6x15/10 (for 1200 blower system), TRC8/6 transition collar (for 600 blower)
  • Wall Caps: WC6HD, WC8HD, WC10HD. WC6x15/HD is for the 1200 blower system with rear ducting.
  • Roof Caps: RC6 and RC10 accommodate 6" to 10" round duct sizes.
  • Backdraft damper: BD8 or BD10 (in-line 8" or 10" section duct with backdraft damper installed).
  • Wall switch kit: UIBWSK controls both lights and fan(s) instead of unit switches.

IMPORTANT: INSPECT ALL MOLDED PACKING AND BOXES FOR PARTS BEFORE DISCARDING. ANY DAMAGE MUST BE REPORTED BEFORE INSTALLING THE HOOD. ONCE THE HOOD HAS BEEN INSTALLED, NO RETURN WILL BE ACCEPTED.

Packing List for UIB Insert

UIB20-600, UIB26-600, UIB30-600, UIB28-600

  • Blower Pre-Installed in Unit
  • One (1) Stainless Steel Baffle Filter
  • Two (2) Pre-Installed Lights
  • Lid for Electrical Box

UIB34-600

  • Blower Pre-Installed in Unit
  • Two (2) Stainless Steel Baffle Filters
  • Two (2) Pre-Installed Lights
  • Lid for Electrical Box

UIB34-1200, UIB40-1200

  • Two (2) Blowers Pre-Installed in Unit
  • Two (2) Stainless Steel Baffle Filters
  • Two (2) Pre-Installed Lights
  • Lid for Electrical Box
  • Transition required and NOT supplied (sold separately)

UIB46-1200, UIB52-1200, UIB58-1200

  • Two (2) Blowers Pre-Installed in Unit
  • Three (3) Stainless Steel Baffle Filters
  • Three (3) Pre-Installed Lights
  • Lid for Electrical Box
  • Transition required and NOT supplied (sold separately)
  • UIB58S2 includes two (2) Filter Spacers

Packing List for UIB Hood Liner

UIB28-NB

  • One (1) Stainless Steel Baffle Filters
  • Two (2) Pre-Installed Lights
  • Lid for Electrical Box
  • Starter Collar Included

UIB34-NB, UIB40-NB

  • Two (2) Stainless Steel Baffle Filters
  • Two (2) Pre-Installed Lights
  • Lid for Electrical Box
  • Starter Collar Included

UIB46-NB, UIB52-NB, UIB58-NB

  • Three (3) Stainless Steel Baffle Filters
  • Three (3) Pre-Installed Lights
  • Lid for Electrical Box
  • Starter Collar Included
  • UIB58-NB includes two (2) Filter Spacers

Packing List for UIBTF or CMUIBTF Hood Liner

UIBTF34-NB, UIBTF40-NB

  • Four (4) Stainless Steel Baffle Filters
  • Two (2) Pre-Installed Lights
  • Lid for Electrical Box

UIBTF48-NB, UIBTF58-NB

  • Six (6) Stainless Steel Baffle Filters
  • Three (3) Pre-Installed Lights
  • Lid for Electrical Box
  • UIBTF580WC15 includes two (2) Filter Spacers

CMUIBTF34-NB, CMUIBTF40-NB

  • Four (4) Stainless Steel Baffle Filters
  • Two (2) Pre-Installed Lights
  • Lid for Electrical Box

CMUIBTF48-NB, CMUIBTF58-NB

  • Six (6) Stainless Steel Baffle Filters
  • Three (3) Pre-Installed Lights
  • Lid for Electrical Box
  • CMUIBTF580WC15 includes two (2) Filter Spacers

Rear Ducting Instructions

In some cases, you will not be able to duct the unit to the top. In that case, rear ducting is necessary.

  1. Lay insert on its face on top of a soft, non-abrasive blanket.
  2. Remove the screws from the L-bracket on the blower assembly. DO NOT LOSE SCREWS.
  3. Disconnect motor wires from the terminal block.
  4. Flip the unit so the exit hole is facing the back of the unit.
  5. Re-apply the screws to the L-bracket on the blower assembly.
  6. Ensure your unit is secure and in place for ducting through the back.

Instructions for Connection of Optional Wall Switch Kit (UIBWSK)

  1. Disconnect wires from Fan and Light switches from the wiring harness supplied with your insert.
  2. Connect Fan and Light switches to the harness supplied with the Prestige® wall switch kit.
  3. Make all electrical connections between the supplied harness and wires for the wall switch inside the insert's electrical box.
  4. Before hanging your hood and wall switch kit, ensure the connections made are fully operational.

IMPORTANT: Be sure to have a licensed electrician make all connections to prevent electric shock. By using a Wall Switch Kit, you will render the on-board controls on your ventilation hood non-operational.

Installation Guide

NOTE: During installation, protect countertop and/or cooking appliances.

  1. Choose an installation height that is comfortable for the user. IMPORTANT: Most building codes require a 30" minimum clearance from the top of a surface burner to the underside of any combustible material.
  2. Choose the appropriate cutout dimension from the cutout dimension section (page 14). Mark the underside of the wood hood, alcove, or hearth, ensuring adequate clearance for the stainless steel trim overlay and body of the hood liner. Cut along your marked line.
  3. Caution: SWITCH POWER OFF AT SERVICE PANEL. Insert 115-volt line through the 7/8" hole punched through the back of the unit and attach with the appropriate ROMEX or BX connector.
  4. Attach the metal duct to the unit either directly to the collar provided or by using a duct transition. See chart B. NOTE: USE RIGID METAL DUCTWORK ONLY. DO NOT ATTEMPT TO USE FLEXIBLE DUCT OR PLASTIC DUCT, AS FLOW RESTRICTIONS AND GREASE BUILD UP WILL OCCUR.
  5. Lift hood liner into position. Fasten to the underside of the wood hood, alcove, or hearth with appropriate fasteners. Ensure the unit is fastened securely to prevent vibration.

A licensed electrician should make all electrical connections.

  1. Complete the electrical connection in the junction box inside the insert. If equipped with an internal fan, check that the fan blade turns freely by hand and that there are no packing materials or other obstructions in the motor housing. Also, ensure light bulbs are tightly screwed into sockets.
  2. Install stainless steel filters by sliding filters into the top channel, then down into the lower channel.
  3. Turn power on at the service panel.

Cutout Dimensions

Use the below dimensions to make the cutout for your Prestige®

Model# Width Depth
UIB28-60025 1/8"13 5/8"
UIB34-60031 1/8"13 5/8"
UIB34-120031 1/8"13 5/8"
UIB40-120037 1/8"13 5/8"
UIB46-120044 5/8"16 5/8"
UIB52-120050 5/8"16 5/8"
UIB58-120056 5/8"16 5/8"
UIB28-NB25 1/8"13 5/8"
UIB34-NB31 1/8"13 5/8"
UIB40-NB37 1/8"13 5/8"
UIB46-NB44 5/8"16 5/8"
UIB52-NB50 5/8"16 5/8"
UIB58-NB56 5/8"16 5/8"
UIBTF3432 3/4"21 1/4"
UIBTF4038 3/4"21 1/4"
UIBTF4644 3/4"21 1/4"
UIBTF5250 3/4"21 1/4"
UIBTF5856 3/4"21 1/4"
CMUIBTF3432 3/4"21 1/4"
CMUIBTF4038 3/4"21 1/4"
CMUIBTF4644 3/4"21 1/4"
CMUIBTF5250 3/4"21 1/4"
CMUIBTF5856 3/4"21 1/4"

Installation of In-Line or Remote Blower

Using the harness supplied with your Prestige® in-line or remote blower, plug into the connector located near the insert finger guard. Make all connections between the supplied harness and wiring connected to the blower using wire nuts (not included) inside the insert electrical box.

Hood Operating Instructions

The blower should be turned on for about 5 minutes BEFORE cooking to establish air currents upward through the insert. Use low speeds for normal use and higher speeds for strong odors or fumes. Minimize drafts across the range or cooktop, as they will reduce the effectiveness of the insert.

Warranty Information

Prestige® warrants all parts and related labor to replace them for a term of one (1) year. This one-year warranty period applies to actual parts and NORMAL labor, excluding all other costs, removal, and re-installation. Prestige® will, at its option, repair or replace, without charge, any product or part found to be defective under normal use and service during the first year from the original date of purchase.

Who is covered? Prestige® warrants to the ORIGINAL CONSUMER PURCHASER of its products that such products will be free from defects in materials and workmanship for a period of one (1) year from the original date of purchase. There are no other warranties, express or implied, including, but not limited to, implied warranties of merchantability or fitness for a particular purpose or application.

What is NOT covered? Items NOT covered in the warranty include: light bulbs, items fabricated to customer design, consequential damage, removal and re-installation, abnormal travel outside the service area (including but not limited to: remote area transport, ferries, or excessive mileage). If any of these situations apply, the customer will be responsible for full payment.

For any questions or concerns, please contact:

Prestige America Ltd.
25 Riverside Dr. Suite 4
Pine Brook, NJ 07058
800-358-8886

PDF preview unavailable. Download the PDF instead.

428463 Mac OS X 10.7.5 Quartz PDFContext Word

Related Documents

Preview Prestige Ventilation Inserts & Liners: Installation, Operation, and Maintenance Guide
Comprehensive guide for Prestige Ventilation Inserts and Liners (UIB, UIBTF, CMUIB, UIM series). Includes safety instructions, installation procedures, operating tips, cleaning advice, parts lists, and warranty information.
Preview Prestige Power Pack Hood Liner Installation, Operation, and Specifications
Detailed installation guide, safety warnings, operating instructions, cleaning procedures, and model specifications for Prestige Power Pack Hood Liners. Includes warranty information.
Preview Prestige Pro Line Hoods (PL) Installation Guide and Manual
This official installation guide provides comprehensive instructions for Prestige Pro Line (PL) model range hoods. It covers safety, handling, ventilation, cleaning, maintenance, installation steps, wiring diagrams, and warranty information for domestic kitchen use.
Preview Prestige Remote Blower 900 CFM / 1200 CFM Installation Guide
Comprehensive installation, use, and care instructions for Prestige RB900-F and RB1200-F remote blowers. Covers safety, venting, roof, flat roof, and wall installation methods, electrical connections, and warranty information.
Preview PRESTIGE 400 Owner's Manual
Comprehensive owner's manual for the PRESTIGE 400 boat, detailing safety procedures, technical specifications, operational guidance, maintenance tips, and winter storage instructions.
Preview Prestige APSRS1Z 1 Channel Remote Car Starter Owner's Manual
Owner's manual for the Prestige APSRS1Z 1 Channel Remote Car Starter, detailing features, operation, and programming for enhanced vehicle convenience and security.
Preview PRESTIGE 440S Owner's Manual - Guide and Specifications
Explore the PRESTIGE 440S owner's manual. Find detailed specifications, safety instructions, operational guidance, and maintenance tips for your PRESTIGE yacht. Learn about hull, deck, engine, electrical systems, and more.
Preview Prestige APS-997E 2-Way LCD Long Range Vehicle Security & Remote Start System Owner's Guide
Comprehensive owner's guide for the Prestige APS-997E 2-Way LCD Long Range Vehicle Security & Remote Start System, detailing features, operation, programming, and troubleshooting for enhanced vehicle security and convenience.