SpaNET SV-3T Quick Reference Guide

Controller Overview

This guide provides a quick reference for the SpaNET SV-3T spa controller, covering its display, indicators, and button functions.

Display Mode Icons

Menu Icons

Status Icons

Indicator LEDs

AUTOMATIC INDICATOR LED: Illuminates when the filtration pump is in automatic mode.

HEATER INDICATOR LED: Illuminates when the heater or heat pump is operating.

SANITISER INDICATOR LED: Illuminates when the ozone or UV sanitiser unit is operating.

SLEEP TIMER INDICATOR LED: Illuminates when the controller is in sleep mode.

Button Functions

The controller features several buttons for operation:

Pump (A,B,C) Buttons

Used to toggle filtration pump and/or additional jet pump(s) on/off.

Blower Button

Press to toggle blower on/off. A single press turns the blower on in vari-speed mode; use [UP Button]/[DOWN Button] to vary speed. A double press activates the ramping mode.

Sanitise Button

Press once to activate a 20-minute sanitisation and clean-up cycle to refresh water quality after spa use. A second press will cancel the cycle if already running.

Invert Screen Button

Press to flip the screen 180° for easy viewing when the spa is in use. Also known as the [PUMP B Button] in some contexts.

Light (ON/OFF) Button

Used to toggle spa lights on/off.

Light (MODE) Button

Press to activate the light mode menu and use [UP Button]/[DOWN Button] to select one of five different lighting effect modes.

OK Button

Used to confirm and save setting adjustments or to enter setting adjustment menus.

Light Speed / Colour Button

Press to activate light speed or user colour selection menus. Use [UP Button]/[DOWN Button] to adjust.

UP Button

Short single presses toggle through the three display modes: Water Temperature (W.TMP), Set Temperature (S.TMP), and Clock (TIME). Holding the button will force the controller to begin adjusting the set temperature and will raise the set temperature point. Also used for adjusting settings.

DOWN Button

Short single presses toggle through the three display modes: Water Temperature (W.TMP), Set Temperature (S.TMP), and Clock (TIME). Holding the button will force the controller to begin adjusting the set temperature and will lower the set temperature point. Also used for adjusting settings.

Keylock Functions

Full Keylock

Press and hold the [UP Button], [DOWN Button], and [PUMP A Button] simultaneously until 'LOCK' appears on the display. Repeat the combination to unlock. Note: Once locked, only pumps, blower, light, and sanitise buttons can be used. Access to all other buttons is disabled.

Partial Keylock

Press and hold the [UP Button], [DOWN Button], and [PUMP B Button] simultaneously until 'LOCK' appears on the display. Repeat the combination to unlock. Note: Once locked, only pumps, blower, light, and sanitise buttons can be used. Access to all other buttons is disabled.

Setup Menu

The setup menu allows customisation of the adjustable controller settings. Access and item adjustments are carried out as follows:

To enter the setup menu, press and hold the [MODE Button] and [OK Button] together until [MODE] is displayed. Use the [UP Button] or [DOWN Button] to navigate through setup menu items. Press the [OK Button] to enter item adjustment, and use the [UP Button] or [DOWN Button] to adjust the setting. Press the [OK Button] to confirm the setting and exit.

All setup menu items follow the same adjustment procedure. Menu items that can be adjusted include:

[MODE] OPERATING MODES

Operating modes affect heating and filtration behaviour. The choices are:

[FILT] DAILY FILTRATION TIME

Adjust the hours of filtration per day. Filtration limits differ for pump types:

Note: Once P.SAV mode is selected, the begin and end times of the PEAK power tariffs must be set so the control knows NOT to operate during those peak hours.

[F.CYC] FILTRATION CYCLES

This setting defines how often filtration cycles occur. Filtration can be set to run every 1, 2, 3, 4, 6, 8, 12, or 24 hours.

[SNZE] SLEEP TIMERS

Used to disable automatic heating and filtration during certain times of day or night. Upon entering the SNZE menu, there are four choices:

Only one sleep timer needs to be set, however, two timers are provided to facilitate different sleep settings on different days. Each sleep timer setting consists of a week day setting, start time, and stop time. Use the [UP Button], [DOWN Button], and [OK Button] to adjust and confirm each setting.

[P.SAV] POWER SAVE (off peak)

Reduce operating costs by limiting filtration and heating to occur during cheaper off-peak power periods. There are three P.SAV modes:

[W.CLN] AUTOMATIC SANITISE

Adjust the start time of the 10-minute automatic daily sanitise cycle. Setting can be adjusted from 0:00 to 23:59.

[D.DIS] DEFAULT DISPLAY MODE

Used to adjust the default display mode shown on the keypad. Setting choices:

[T.OUT] LOAD TIME OUTS

All accessory loads (pumps & blowers) automatically turn off after a time-out period has elapsed. Adjust the time-out period from 10-60 minutes.

[H.PMP] HEAT PUMP MODE

Defines heat pump operating mode:

[H.ELE] ELEMENT BOOST

Enables/disables SV electric element to boost heat pump heating if the water temperature is 2°C or more below the set temperature point OR the heat pump has been operating for more than 1 hour.

Other Functions

Changing Light Modes

Press the [Light (mode) Button] to display the current light mode in use. Press the [UP Button] or [DOWN Button] to step through the choice of light modes:

Changing Light Speed or Light Colour

Dependent on the light mode selected, the [Light (spd/clr) Button] will activate one of three light mode option screens:

Press the [UP Button] or [DOWN Button] to adjust each setting. Press the [OK Button] to save each setting and move to the next setting. Note: All light settings are saved for future ON/OFF use.

Models: SV-3T, SV3 Spa Pool Controller, SV3, Spa Pool Controller, Pool Controller, Controller

PDF preview unavailable. Download the PDF instead.

SV3 quickref web24 Corel PDF Engine Version 25.1.0.269 CorelDRAW 2024

Related Documents

Preview SpaNET SV2 Quick Reference Guide
A concise guide to the SpaNET SV2 spa control system, detailing button functions, indicator lights, and menu options for easy operation and setup.
Preview SpaNET SV4 Quick Reference Guide
A concise guide to the SpaNET SV4 control system, detailing display and menu icons, status indicators, button functions, and advanced settings for spa operation.
Preview SpaNET Eco Cube Heat Pump Installation and User Manual
Comprehensive guide for SpaNET SV Series Eco Cube heat pumps (CHP-33, CHP-55). Learn about efficient spa heating, installation, operation, and maintenance for optimal performance and energy savings.
Preview SpaNet SV Series Spa Controls: User Manual & System Overview
A comprehensive guide to SpaNet SV Series spa controls (SV2.T, SV3.T, SV4.T), covering operation, PowerSMART features, keypad functions, heating, lighting, sanitisation, setup, and troubleshooting for optimal spa management.
Preview Spanet Eco Cube Heat Pump Installation Guide: Water Pipe Connections and Plumbing
Detailed installation guide for the Spanet Eco Cube Heat Pump, covering water pipe connections, fittings, spa plumbing integration, and essential plumbing diagrams. Ensure correct setup for optimal performance and safety.
Preview SmartLink V3 WiFi Controller Quick Install Guide
A quick installation guide for the SmartLink V3 WiFi Controller by Spanet, detailing steps for setup, app connection, and module placement.