GREE VIREO GEN 3 Single-Zone, Heat Pump System

MODELS:

Thank you for choosing our product. Please read this Installation & Owner's Manual carefully before operation and retain it for future reference.

If you lose this Manual, please contact your local distributor or visit www.greecomcomfort.com/resources to download and file the electronic version.

CAT NO: GREE_VIREO GEN3_BO_INSTALL_12282022

Explanation of Symbols

[WARNING] This symbol indicates the possibility of death or serious injury.

[CAUTION] This symbol indicates the possibility of injury or damage to property.

[NOTICE] Indicates important but not hazard-related information, used to indicate risk of property damage.

Exception Clauses

Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons:

  1. Damage the product due to improper use or misuse of the product;
  2. Altering, changing, maintaining or using the product with other equipment without following the recommendations in manufacturer's instruction manual;
  3. After verification, the product defect is directly caused by corrosive gas;
  4. After verification, the defects are due to improper operation or handling during the transportation of product;
  5. Operating, repairing or maintaining the unit without following the instruction manual or related regulations.
  6. After verification, the problem or dispute is caused by the quality or performance of parts and components produced by other manufacturers;
  7. The damage is caused by natural disasters, a hazardous environment or force majeure.

If you need to install, move or maintain this air conditioner, please use a licensed HVAC dealer to avoid serious damage or personal injury or death. When refrigerant leaks or requires discharging during installation, maintenance, or disassembly, it should be handled by certified professionals in compliance with local laws and regulations.

This equipment is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the equipment by a person responsible for their safety. Children should be supervised to ensure that they do not play with the equipment.

Safety Precautions

[WARNING] Installation

[CAUTION] Installation

[WARNING] Operation and Maintenance

[CAUTION] Operation and Maintenance

Parts Name

Outdoor Unit

Diagram of the outdoor unit showing 'air inlet' and 'air outlet'.

NOTE: Actual product may be different from above graphics, please refer to actual product.

Installation Notice

Diagram showing required clearances around the outdoor unit: Space to the wall (At least 12 in), Space to the obstruction (At least 20 in), Space to the obstruction (At least 12 in), Space to the obstruction (At least 78 in), Drainage pipe, Space to the obstruction (At least 20 in).

Safety Precautions for Installing and Relocating the Unit

To ensure safety, please be mindful of the following precautions.

[WARNING]

Tools for installation

NOTICE: Please contact the local agent for installation. Don't use unqualified power cold.

Selection of Installation Location

Basic requirement

Installing the unit in the following places may cause malfunction. If it is unavoidable, please consult the local dealer:

Outdoor unit

Safety precaution

Requirements for electric connection

Grounding requirement

Installation of Outdoor Unit

Step 1: Fix the support of outdoor unit (select it according to the actual installation situation)

  1. Select installation location according to the house structure.
  2. Fix the support of outdoor unit on the selected location with expansion screws.

Diagram showing outdoor unit support with labels 'drain vent', 'chassis', 'outdoor drain joint', 'Drain hose'.

Step 2: Install drain joint (only for some models)

  1. Connect the outdoor drain joint into the hole on the chassis, as shown in the picture below.
  2. Connect the drain hose into the drain vent.

NOTICE: As for the shape of drainage joint, please refer to the current product. Do not install the drainage joint in the severe cold area. Otherwise, it will be frosted and then cause malfunction.

Step 3: Fix outdoor unit

  1. Place the outdoor unit on the support.
  2. Fix the foot holes of outdoor unit with bolts.

Diagram showing outdoor unit placement on support with 'foot holes' labeled. The unit should be at least 3cm above the floor.

NOTICE: Take sufficient protective measures when installing the outdoor unit. Make sure the support can withstand at least four times of the unit weight. The outdoor unit should be installed at least 1-1/4 in above the floor in order to install drain joint. (For the model with heating tube, the installation height should be no less than 8 in.) For the unit with cooling capacity of 9000 - 12000 Btu, 6 expansion screws are needed; for the unit with cooling capacity of 24000~30000 Btu, 8 expansion screws are needed; for the unit with cooling capacity of 36000+ Btu, 10 expansion screws are needed.

Step 4: Connect indoor and outdoor pipes

  1. Remove the screw on the right handle of outdoor unit and then remove the handle.
  2. Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe.
  3. Pretighten the union nut with hand.

Diagram showing connection of pipes to valves with labels 'liquid valve', 'gas valve', 'liquid pipe', 'gas pipe', 'pipe joint', 'union nut'.

Step 5: Connect outdoor electric wire

  1. Remove the wire clip; connect the power connection wire and signal control wire (only for cooling and heating unit) to the wiring terminal according to the color; fix them with screws.

Wiring diagrams for 09K/12K and 18K/24K units showing indoor unit connection and power terminals with color codes (e.g., green/yellow-green for ground, black/brown for L1, white/blue for N, red for L2).

NOTICE: The wiring board is for reference only, please refer to the actual one.

  1. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit).

NOTICE: After tightening the screw, pull the power cord slightly to check if it is firm. Never cut the power connection wire to prolong or shorten the distance.

Step 6: Pipe Neatly

  1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Minimum semi-diameter of bending the pipe is 4 in.
  2. If the outdoor unit is higher than the wall hole, you must set a U-shaped curve in the pipe before the pipe goes into the room, in order to prevent rain from getting into the room.

Diagram showing a U-shaped curve in the pipe for drainage.

NOTICE: The through-wall height of drain hose should not be higher than the outlet pipe hole of the indoor unit. The water outlet can't be placed in water in order to drain smoothly. Slant the drain hose slightly downwards. The drain hose can't be curved, raised and fluctuant, etc.

Test and Operation

Use vacuum pump

  1. Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging vent.
  2. Connect the charging hose of gauges to the refrigerant charging vent of gas valve and then connect the other charging hose to the vacuum pump.
  3. Open the gauges completely and operate for 10-15 min to check if the pressure gauge remains in -15 psi.
  4. Close the vacuum pump and maintain this status for 1-2 min to check if the pressure of gauge remains in -15 psi. If the pressure decreases, there may be a leak.
  5. Remove the gauges, open the valve core of liquid valve and gas valve completely with inner hexagon spanner.
  6. Tighten the screw caps of valves and refrigerant charging vent.
  7. Reinstall the handle.

Diagram showing vacuum pump setup with labels 'liquid valve', 'gas valve', 'refrigerant charging vent', 'nut of refrigerant charging vent', 'gauges', 'valve cap', 'vacuum pump', 'inner hexagon spanner'.

Leak detection

  1. With a leak detector: Check if there is a leak.
  2. With soap water: If leak detector is not available, please use soapy water for leak detection. Apply soap water at the suspected position and keep the soap water for more than 3 min. If there are air bubbles coming out of this position, there's a leak.

Check after installation

Check according to the following requirements after finishing installation.

Items to be checked Possible malfunction
Has the unit been installed firmly? The unit may drop, shake or emit noise.
Have you done the refrigerant leak test? It may cause insufficient cooling(heating) capacity.
Is heat insulation of pipeline sufficient? It may cause condensation and water dripping.
Is water drained well? It may cause condensation and water dripping.
Is the voltage of power supply according to the voltage marked on the nameplate? It may cause malfunction or damage the parts.
Is electric wiring and pipeline installed correctly? It may cause malfunction or damage the parts.
Is the unit grounded securely? It may cause electric leakage.
Does the power cord follow the specification? It may cause malfunction or damage the parts.
Is there any obstruction in the air inlet and outlet? It may cause insufficient cooling(heating) capacity.
The dust and sundries caused during installation are removed? It may cause malfunction or damage the parts.
The gas valve and liquid valve of connection pipe are open completely? It may cause insufficient cooling (heating) capacity.
Is the inlet and outlet of piping hole been covered? It may cause insufficient cooling (heating) capacity or waste electricity.

Test operation

  1. Preparation of test operation
    • The client approves the air conditioner.
    • Specify the important notes for air conditioner to the client.
  2. Method of test operation
    • Put through the power, press ON/OFF button on the remote controller to start operation.
    • Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check whether the operation is normal or not.
    • If the ambient temperature is lower than 16°C (61°F), the air conditioner can't start cooling.

Configuration of Connection Pipe

  1. Standard length of connection pipe: 5m, 7.5m, 8m.
  2. Min. length of connection pipe is 3m.
  3. Max. length of connection pipe is shown as below.
Cooling capacity Max. length of connection pipe(ft)
9000Btu/h (2637W) 50
12000Btu/h (3516W) 66
18000Btu/h (5274W) 82
24000Btu/h (7032W) 82

4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe.

Additional refrigerant charging amount for R410A

Piping size Outdoor unit throttle
Liquid pipe Gas pipe Clg and htg (oz/ft)
1/4" 3/8" or 1/2" .215
1/4" or 3/8" 5/8" or 3/4" .54
1/2" 3/4" or 7/8" 1.29
5/8" 1" or 1 1/4" 1.29
3/4" - 2.7
7/8" - 3.76

Pipe Expanding Method

NOTICE: Improper pipe expanding is the main cause of refrigerant leaks. Please expand the pipe according to the following steps:

A: Cut the pipe

Confirm the pipe length according to the distance of indoor unit and outdoor unit. Cut the required pipe with pipe cutter.

Diagram showing pipe cutting with labels 'pipe', 'pipe cutter' and examples of good (90°) and bad (leaning, uneven, burr) cuts.

B: Remove the burrs

Remove the burrs with shaper and prevent the burrs from getting into the pipe.

Diagram showing burr removal with labels 'pipe', 'shaper', 'downwards' and examples of good (smooth surface) and bad (improper expanding, leaning, damaged, crack, uneven thickness) surfaces.

C: Put on suitable insulating pipe

D: Put on the union nut

Remove the union nut on the indoor connection pipe and outdoor valve; install the union nut on the pipe.

Diagram showing union nut installation with labels 'pipe', 'union pipe'.

E: Expand the port

Expand the port with expander.

Diagram showing pipe expansion with 'expander', 'hard mold', 'pipe' and examples of good (smooth surface, length equal) and bad (improper expanding, leaning, damaged, crack, uneven thickness) expansion.

Outer diameter (mm) A(mm)
Max Min
Φ6 - 6.35(1/4") 1.3 0.7
Φ9 - 9.52(3/8") 1.6 1.0
Φ12-12.7(1/2") 1.8 1.0
Φ15.8-16(5/8") 2.4 2.2

F: Inspection

Check the quality of expanding port. If there is any blemish, expand the port again according to the steps above.

Working Temperature Range

3VIR09HP230V1AO, 3VIR12HP230V1AO, 3VIR18HP230V1AO, 3VIR24HP230V1AO

Indoor side Outdoor side
DB/WB(°C / °F) DB/WB(°C / °F)
Maximum cooling 26.7/19.4 (80/67) 50/24 (122/75)
Maximum heating 26.7/-(80/-) 30/18 (86/65)

NOTE: The operating temperature range (outdoor temperature) for cooling is -29°C(-20°F)~50°C(122°F); for heating is -30°C(-22°F)~30°C(86°F).

3VIR09HP115V1AO,3VIR12HP115V1AO

NOTE: The operating temperature range (outdoor temperature) for cooling is -25°C(-13°F)~50°C(122°F); for heating is -30°C(-22°F)~30°C(86°F).

LIMITED WARRANTY STATEMENT

FOR WARRANTY SERVICE OR REPAIR:

Contact your installing contractor. You may find the installer's name on the equipment or in your Owner's packet. Complete product registration below and keep on file for future reference. Warranty registration: Register your unit(s) on www.greecomfort.com, follow links to "Warranty Registration".

PRODUCT REGISTRATION

Model No.:

Serial No.:

Owner Name:

Address of Installation:

Installing Contractor:

Address:

Phone No. / E-mail:

Date of Installation:

GREE distributor (hereinafter "Company") warrants this product against failure due to defect in materials or workmanship under normal use and maintenance as follows. All warranty periods begin on the date of original installation. If the date cannot be verified, the warranty period begins one hundred twenty (120) days from date of manufacture. If a part fails due to defect during the applicable warranty period, Company will provide a new or remanufactured part, at Company's option, to replace the failed defective part at no charge for the part. This limited warranty is subject to all provisions, conditions, limitations and exclusions listed below.

LIMITATIONS OF WARRANTIES

ALL IMPLIED WARRANTIES AND/OR CONDITIONS (INCLUDING IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE OR PURPOSE) ARE LIMITED TO THE DURATION OF THIS LIMITED WARRANTY. SOME STATES OR PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER.

THIS WARRANTY DOES NOT COVER:

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. In jurisdictions where warranty benefits conditioned on registration are prohibited by law, registration is not required, and the STANDARD warranty period shown above will apply.

WS0003102021 DLSWARR-HP

66129937224

U.S. CONTACT INFORMATION TRADEWINDS, LLC

E-mail: info@twclimate.com

Contractor Support: 888-850-7928 | Mon-Fri 8 AM - 5 PM EDT

GREECOMFORT.COM

CAT NO: GREE_VIREO GEN3_BO_INSTALL_12282022

PDF preview unavailable. Download the PDF instead.

958-VIR18HP230V1BO installation Adobe Illustrator CS6 (Windows) Adobe PDF library 10.01

Related Documents

Preview GREE Vireo Gen3 Single-Zone Heat Pump System Installation Manual
This installation manual provides detailed instructions for the GREE Vireo Gen3 Single-Zone Heat Pump System. It covers safety precautions, installation procedures for indoor and outdoor units, pipe and electrical connections, testing, operation, refrigerant charging, and the limited warranty statement.
Preview Gree 12000 BTU Vireo Gen 3 Wall Mounted Heat Pump System - 3VIR12HP115V1A Specifications
Comprehensive submittal data and specifications for the Gree 12000 BTU/H Vireo Gen 3 wall-mounted heat pump system (3VIR12HP115V1A). Includes detailed performance ratings, features, dimensions, and electrical requirements for cooling and heating.
Preview GREE Vireo Gen 3 9000 BTU/H Heat Pump Submittal Data
Detailed submittal data for the GREE Vireo Gen 3 9000 BTU/H wall-mounted heat pump system, including specifications, features, dimensions, and installation clearances.
Preview AHRI Certified Product Ratings: Gree Vireo GEN3 Mini-Split Heat Pump
Official AHRI Certified product rating certificate for the Gree Vireo GEN3 Mini-Split Heat Pump (Model: 3VIR09HP230V1BO/3VIR09HP230V1BH). Details cooling capacity, SEER2, EER2, heating capacity, and HSPF2 ratings. Includes disclaimer and terms.
Preview GREE Vireo GEN3 Mini-Split Heat Pump Owner's Manual
Comprehensive owner's manual for the GREE Vireo GEN3 (3VIR) series mini-split heat pump system. Covers installation, operation, maintenance, troubleshooting, and energy-saving tips.
Preview GREE 24000 BTU/H Floor/Ceiling Heat Pump System Submittal Data
Comprehensive submittal data for the GREE VIREO GEN 3 24000 BTU/H Floor/Ceiling Heat Pump System. Details specifications, features, functions, and dimensions for models FLR24HP230V1BF and 3VIR24HP230V1AO, highlighting DC Inverter technology and wide operating temperature range.
Preview AHRI Certified Product Ratings Certificate for GREE Mini-Split Heat Pump
Official certificate detailing the performance ratings for a GREE Mini-Split Heat Pump (Model: HRCU-A-CB-O, Outdoor: 3VIR24HP230V1BO, Indoor: CAS24HP230V1BC) as certified by AHRI, including cooling and heating capacities, SEER2, EER2, and HSPF2 ratings.
Preview GREE GWHD(36)ND3MO Multi-Zone Heat Pump System: Specifications and Capabilities
Detailed specifications, features, and allowable indoor/outdoor unit combinations for the GREE GWHD(36)ND3MO 36000 BTU/H Multi-Zone Heat Pump System, including performance data, dimensions, and clearances.