This Quick Guide is intended to help you understand the operation of the TENS unit faster, but it cannot take the place of the user manual. Be sure to read the user manual before use so you are aware of any contraindications and warnings. If you're not sure whether this device is suitable for you, consult your doctor f irst.
OPERATION STEPS
Note: Do not use it while charging.

1. Clean the application areas.

2. Connect the lead wire to a pair of pads and the device(keep the unit off).

3. Attach the pads to the skin firmly.

4. Long press the " "button to turn on the device.

M+ M- T

M+ M- T

5. Choose a mode.

6. Adjust intensity with the buttons +/-.

M+ M- T
7. Set time.

M+ M- T
8. Press to lock/ unlock the unit.

9. Long press the " "button to turn off the device after massage.

10. Remove the pads; do not pull the wire.

Pad Placement Suggestion
Notes: 1. Do not use the unit in the shower, sleeping, driving, operating machinery, or during any electrically-stimulated activity. 2. The electrode pads should not be overlapped nor placed on the artery, broken skin, or on the same side of the arm/leg.

USER MANUAL
TENS & EMS Device
Please read the product introduction carefully before using the product Model TU3236
Device name: TENS & EMS Device

TABLE OF CONTENTS
1. Explanation of TENS & EMS & Massage ........ 7 2. Standard Package............................................. 7 3. Illustration of the Device.................................... 8 4. Operating Instructions..................................... 10
4.1 Note Before Use..................................... 10 4.2 How to Use............................................. 10 4.3 After Use................................................. 15 4.4 Charge the Battery.................................. 16 5. Mode Instruction.............................................. 16 5.1 Mode & Function..................................... 17 5.2 Mode Description.................................... 17
5.3 Pad Placement Suggestion.................... 21 6. TENS Electrode Pads & Pads Holder............. 25
6.1 Features.................................................. 25 6.2 Instruction............................................... 26 6.3 Electrode Pads Care and Storage.......... 27 6.4 Electrode Pads Precautions.................... 28 7. Safety Precautions and Warnings.................. 29 7.1 Prohibited Conditions............................. 29 7.2 Prohibited Individuals............................. 30 7.3 Prohibited Areas..................................... 30 7.4 Prohibited Activities................................ 31 8. Trouble Shooting ........................................... 31 9. Features.......................................................... 34 10.. Symbols........................................................ 35 11.. Certification .................................................. 37 12.. Customer Service......................................... 37

Email support@iauvon.com
1. Explanation of TENS & EMS & Massage
Transcutaneous Electrical Nerve Stimulation (TENS) is a non-invasive, drug-free method of pain control. TENS uses tiny electrical impulses sent through the skin to nerves to modify your pain perception. TENS is used for temporary relief of pain associated with sore and aching muscles in the shoulder, waist, back, neck, upper extremities (arm), and lower extremities (leg) due to strain from exercise or normal household work activities. Electrical Muscle Stimulation (EMS) stimulates the muscles rather than the nerve cells. EMS stimulates your motor nerves, which induces muscle contractions, and mimics the way they contract during a workout. It will force the muscles to rapidly contract and relax. Massage could increase blood flow to the affected area by transmitting electrical impulses to your muscles via the pads. In addition, Massage causes your body to release endorphins, which help to reduce stress.
2. Standard Package
 AUVON TENS & EMS & Massage Device  Pin pads  Pads Holder  Pouch  Set of Lead Wires  USB-C Cable  User Manual
7

Email support@iauvon.com
3. Illustration of the Device
8

Email support@iauvon.com
 Two output connectors  A intensity adjustment (+/-)  B intensity adjustment (+/-)  Power button  Lock indicator  Main mode indicator  Battery indicator  Intensity indicator (Channel A)  Intensity indicator (Channel B)  Pulse rate indicator  Pulse width indicator  Mode increase (+)  Mode decrease (-)  Time Selection  Lock button  USB port
9

Email support@iauvon.com
4. Operation Instructions
4.1 Note Before Use 4.1.1. Do not use this device while charging. 4.1.2. The backlight of the screen will automatically come off after 15 seconds of no operation; when the device has no output and no operation, it will shut down automatically in 5 minutes. 4.1.3. You may experience tingling, trembling, or muscle pulling when using the device, so please try out all the modes and select the one that's most comfortable for you. 4.1.4. For initial use, the intensity should be set between 1-3. If you feel the intensity is weak in 1-2 minutes, gradually increase it and select the most comfortable setting. 4.1.5. It is recommended to use the device for 20-30 minutes and to stop using it when pain is relieved. 4.2 How to Use
4.2.1 Clean and dry the application area, do not attach electrode pads to the hairy and broken skin.
TIP: Use it on the hairless, no oil and no sweat part, or it will reduce the pads' adhesion.
10

Email support@iauvon.com
4.2.2 Take out the pads from the sealed packaging and keep the packaging for future storage.
4.2.3 Connect one pair of electrode pads to one lead wire and connect the other end of the wire to the A or B output of the device.
11

Email support@iauvon.com
4.2.4 Grab the corner of the electrode pad and peel it off the protective film, and do not pull the wire directly. Attach one pair of electrode pads to the massage area and press the edge of the electrode pads firmly on your skin to make sure full contact. Use the second port with two additional pads on other pain areas for relief. (Make sure the unit is off when you attach the pads. )
NOTE: Each lead wire should be connected to a pair of pads (2 pads), or it won't work.
4.2.5 Turn on the device by pressing the " " button for 2 seconds.
12

Email support@iauvon.com

4.2.6 Press the M+/ M- button to choose a mode.

M+ M- T

4.2.7 To increase or decrease the intensity of the selected channel, please press the A/B intensity adjustment (+/) button. For initial use, the intensity should be set between 1-3. If you feel the intensity is insufficient in 1-2 minutes, gradually increase it and select the most comfortable setting. NOTE: The intensity will revert to the lowest setting with each mode selection.

M+ M- T

13

Email support@iauvon.com
4.2.8 Use the "T" button to set the massage time from 10-90 minutes and continuous mode (unlimited time). When the remaining time is less than 1 minute with no action, the screen will flash 3 times to remind you, and then the device will automatically turn off when the time is up.
M+ M- T
NOTE: When the device is in continuous mode and the channel has output, the unit will go on until the battery is exhausted unless it is manually turned off. If the channel has no output and no operation, the device will automatically shut down within 5 minutes.
14

Email support@iauvon.com

4.2.9 Press the " " button to lock the screen, then the intensity, mode and time can't be changed. Press the " " button again to unlock the screen. NOTE: Do not move the pads or remove the lead wires during the use, or you may be shocked.

M+ M- T

4.3 After Use 4.3.1 Turn off the device by pressing and holding the for 2 seconds. 4.3.2 Grab a corner of the electrode pad and slowly peel it away from the skin, do not pull the wire, and avoid touching the gel as much as possible. 4.3.3 Place the sticky side of the pad on the transparent film or pad holder and remove the lead wire connector from the electrode pads gently. 4.3.4 Store the electrode pads in the storage bag and reseal tightly to prevent them from dry-out. Store them at room or cool temperature (between 5-35/41-95) and keep out of direct sunlight. 4.3.5 Organize the wires with the cable tie and store all of them in the pouch for the store.
15

Email support@iauvon.com
4.4 Charge the Battery 4.4.1 When the battery icon shows " " or the massage strength decreases, it indicates that the battery needs to charge. Turn off the unit. 4.4.2 Connect the device and the charger with a USB extension cord. Plug the charger into any power outlet, the power box appears and blinks, and the time display value will update to the percentage of charge. All other icons are removed and not displayed.

Charging Parameters

Input Output

DC 5V 117V at 500 ohm Load

4.4.3 The machine does not work while charging. Normal charging will last approximately 3-4 hours. TIP: Charge the unit at least every 3 months if it is not used regularly.

5. Mode Instruction
5.1 Mode & Function

Main Mode 1: Acupuncture

Modes Suitable for relieving 1~6 joint pain in limbs.

Main Mode 2: Cupping

Modes 7~12

Suitable for back, shoulder, and neck pain relief.

16

Main Mode 3: Scraping
Main Mode 4: Tui na
Main Mode 5: EMS
Main Mode 6: Massage

Email support@iauvon.com

Modes 13~18

Suitable for upper limb muscle pain relief.

Modes 19~24

Suitable for lower limb muscle pain relief.

Modes 25~29

Auxiliary exercises, used to strengthen muscles.

Suitable for muscle

Modes 30~36

fatigue after exercise, and muscle relaxation.

5.2 Mode Description

Mode Type

Mode Num- Frequency

ber

(Hz)

Pulse Width (uS)

1

8~21.65 240

2 TENS
3

8~23.89 240

20.4

240

4

30.38

240

17

Email support@iauvon.com

Mode Type

Mode Num- Frequency

ber

(Hz)

Pulse Width (uS)

5

32~23~32 240

6

0-5

0-300

7

32~23~32 240

8

0~25.15 240

32~23~32

9

240

2

2

10 TENS

21.62 240
32~23~32
2

11

10-55

80

75

12

80

11-98

13

2. 7-30

240

14

1.6-13. 7 240

15

41.6

240

16

85

200

17

100

150

18

18

19

20

TENS

21

22

23

24

25

26

EMS

27

28

29

30

MASSAGE 31

Email support@iauvon.com

75 80
11-98

43

240

8

240

1.42

240

42

240

47

80

67 80
90

5

240

7

240

4~20

240

50

240

15

240

43

240

63

98

80

1.6

19

Email support@iauvon.com

32
33 MASSAGE
34 35 36

92

92 80
98

1.6

2.7-32

40

240

42

2

11-98

80

90

67 80
90

2.6-1.1 80
80

20

Email support@iauvon.com
5.3 Pad Placement Suggestion

Neck Pain

Shoulder Pain

Modes: 7, 8, 9, 10, 19, 20, 22

Modes: 11, 12, 19, 20, 21, 22, 32, 35, 36

Tennis Elbow

Carpal Tunnel Syndrome

Modes: 1, 2, 3, 4, 27, 34 Back Pain

Modes: 1, 2, 3, 4, 5, 6, 17
Sciatica

Modes: 16, 17, 18, 30, 31, 32, 33, 34

Modes: 19, 20, 22, 31, 32
21

Email support@iauvon.com Hip/Thigh Pain

Period Pain

Modes: 19, 20, 22, 25, 28, 31, 32
Knee Pain

Modes: 9, 35, 36 Claf Pain

Modes: 1, 6, 28, 30 Ankle Pain

Modes: 14, 15, 19, 20, 21, 22, 23, 24, 25, 26
Plantar Fasciitis

Modes: 1, 13, 25, 26, 29

Modes: 19, 20, 21, 22

22

Biceps

Email support@iauvon.com Abs

Modes: 25, 26, 27, 29, 32, 35, 36
Glutes

Modes: 28, 35, 36 Hamstrings

Modes: 25, 26, 27, 28, 29, 31, 32
Quadriceps

Modes: 30, 31, 32, 33, 34
Calves

Modes: 25, 26, 27, 28, 29, 31, 32
23

Modes: 25, 26

Email support@iauvon.com
6. TENS Electrode Pads & Pads Holder
6.1 Features
High-quality ABS material to make sure you use it safely.
Widely compatible for patches in different sizes.
The salient points are specially for lessening damage to the pads.
24

6.2 Instruction

Email support@iauvon.com

Step 1 Stick the electrode pads on the holder to avoid getting dust.

Step 2

Wind the thread around the holder for easy use as shown.
25

Email support@iauvon.com
Step 3 Store the electrodes in the storage bag and reseal the bag tightly.
6.3 Electrode Pads Care and Storage  Do not cover the sticky side of the electrode pads with subjects like dry paper or dust, but if you do, please drop a few drops of water and clean with finger pulp to remove dirt.  To extend the electrode pads' lifespan, drop a few drops of water on the sticky side and dry it naturally on the pad holder with the sticky side facing up, and then it will become sticky again. (Excessive water will decrease the stickiness.)  Cover the sticky side of the electrode pads with the transparent film, and store them in the sealed bag. (Dust on the gel will decrease the stickiness of the
26

Email support@iauvon.com
electrode pads.)  Please store the electrode pads in a cool (between 5-35/41-95) and dry place. Do not expose the electrode pads to sunlight or any extreme temperatures to prolong the lifespan of the electrode pads.  When the electrode pad has the following conditions, please do not use it and promptly replace it: gel melting; gel get damaged; electrode pads not sticking; electrode pads deformed.
6.4 Electrode Pads Precautions
 Do not use it when driving a motor vehicle, bathing, showering, swimming, or exercising.  Do not use the following areas: heart, spine, eyes, mouth, carotid artery, or throat; broken, excessively swollen and red, infected and inflamed, or rash skin (e.g. phlebitis, thrombophlebitis, varicose veins).  Do not apply ointment or solvent to the electrode pads or the area where to be used.  The electrode pads should not touch metal objects like belt buckles, necklaces, or other metal worn under clothes.  Please refer to the following principles when using:
* During use, please ensure your hands and application area are clean and dry to avoid electric shock when inserting and removing electrode pads and wires.
* Please attach electrode pads to a flat area to ensure the electrode does not warp. Avoid placing the electrode pads on joints such as the knee, elbow,
27

Email support@iauvon.com
ankle, etc. * Do not overlap or bend the electrode pads when
applying to the skin, or the device may stop working, and the gel may be damaged when separating. The electrode pads should be at least one inch apart from each other. Changing the distance between the electrode pads or the orientation of the electrode pads can change the electrical sensation.
* Ensure each connection port is well connected before use, or the current may be unstable. Do not move the electrode pads or unplug the lead wires by hand during the usage, or you will be shocked.
* It is recommended to use the electrode pads for 20-30 minutes per part, 1-2 times a day, with the intensity based on personal feeling. Attaching the pads to one area for a long time will make the skin unbreathable and lead to redness or itching. If your skin is irritated during the use, stop using the electrode pads and consult your doctor.
* Please turn off the unit first and remove the pads from your skin, or you will be shocked.
* When removing the electrode pads, grab the corner of the electrode pad with your finger pulp and peel it off, do not touch the gel with your nail, and do not pull the wire, or the electrode pad and lead wire will be damaged.  Keep electrode pads out of the reach of children or pets.
7. Safety Precautions & Warnings
7.1 Prohibited Conditions The wire is broken.
28

Email support@iauvon.com
The electrode pads are not sticky, deformed or damaged. The lead wire connection port is broken. 7.2 Prohibited Individuals  Pregnant women, infants, and children.  People who are unable to express their thoughts or intentions.  People who are incapable of operating the device by themselves.  People who tend to bleed internally after an injury or fracture.  Patients with suspected or confirmed heart disease or epilepsy. 7.3 Prohibited Areas  Any part of the head or face.  Any part of the throat and its vicinity, can cause severe muscle spasms and lead to choking.  The heart and its vicinity or genital area.  Open wounds or rash areas.  Swollen, red, infected or inflamed areas.  Areas of skin erosion (caused by varicose veins, phlebitis, thrombophlebitis, and thrombosis).  Sites on or near cancerous lesions.  Skin that lacks normal sensation.  Do not use the electrode pads in the following two areas at the same time, because the current may cause heart rhythm disorders, or even cause death. a. Both sides of the chest (left and right or front and back) or through the chest. b.Calves of both legs. c. Bottom of both legs.
7.4 Prohibited Activities
29

Email support@iauvon.com
 Shower or bath.  Sleeping.  Driving or operating machines.  Exercising.  Any activities that cannot be interfered with.

8. Trouble Shooting
If your device is not operating properly, please check below for common problems and suggested solutions. If the recommended action does not solve the problem, please contact customer service.

Problem

Possible Cause

Have you increased the intensity for the right channel?

Solution
Try to increase the intensity for the right channel and wait for 1 minute to feel the pulse.

The unit is on while no pulse is felt in the pads.

Only apply 1 pad Attach a pair of pads (of

on the massage the same channel) to the

area?

massage area.

Poor connection between the pads and the device?

Connect both ends of the lead wires to the pads and the device tightly or change a new lead wire.

Poor contact between the pads and massage area.

Attach pads to the skin (no hair, unbroken and flat) firmly.

30

Email support@iauvon.com

Problem

Possible Cause

One pad feels stronger than the other.

Different body areas react differently.
Poor wire connection.

The device can't turn on.

Low battery.
The device is charging.

Solution
Try to change the position of the pads.
Plug the wire into the output port completely. If it does not work, replace the wire and try again. Charge the battery and a full charge may need 3-4 hours.
Unplug the charging cable and then turn it on again.

Can't adjust the intensity/ mode/ time.

Adjust the intensity for the wrong channel.

The screen is locked.

If you want to adjust the intensity for channel A, press "+/-" on the left side to select channel A and adjust its intensity, while press "+/-" on the right side to select channel B and adjust its intensity. (The selected channel will blink.) If there's a lock icon on the top right side of the screen, please press the key button to unlock it.

31

Email support@iauvon.com

Problem

Possible Cause

Solution

Pads are not attached to the body firmly. The intensity The intensity is felt is very too low. weak.
Low battery.

Attach both pads firmly to the flat skin.
Increase the intensity level and wait for 1 minute to feel the pulse.
Charge the battery and a full charge may need 3-4 hours.

Power cuts off during use.

Low battery.

Charge the battery and a full charge may need 3-4 hours.

The countdown is finished.

Set the time for your device with the "T" button from 1090 minutes and the continuous mode (infinite time).

9. Features

Mechanism

Technical Description

Wave Form Symmetrical Bi-Phasic Square
32

Email support@iauvon.com
Pulse Voltage 0- 100V (Load: 500 ohm)

Power source 300mAh lithium battery

Size

12.7cm(L)x6.4cm(W)x1.3cm(H)

Weight
Operating Condition

101grams.
Atmosphere Pressure: 700 Hpa~1060 Hpa.

Remark

There may be a +/-5% tolerance of all parameters and +/-20%tolerance of amplitude & voltage.

10. Symbols
Symbol

Meaning

Attention, consult accompanying documents

BF Isolated Applied Part

Class II equipment

33

Email support@iauvon.com

Symbol

Meaning

Disposal in accordance with Directive 2002/96/EC

MANUFACTURER
Date when the medical device was manufactured.
AUTHORIZED REPRESENTATIVE IN THE EUROPEAN COMMUNITY

Please read the user manual before use.

CE Mark meets compliance of applicable directives and regulations in EU

34

Email support@iauvon.com

Symbol

Meaning

IP22

IIIP Classification: The first number 2: Protected against access to hazardous parts with a finger, and the jointed test finger of 12 mm , 80 mm length, shall have ad- equate clearance from hazardous parts, and protected against solid foreign objects of 12.5 mm  and greater. The second number: Protected against vertically falling water drops when the enclosure is tilted up to 15º. Vertically falling drops shall have no harmful effects when the enclosure is tilted at any angle up to 15'' on either side of the vertical.

11. Certification
The device complies with following normative documents: ANSI/AAMI/ES 60601-1, IEC60601-1-2, IEC60601-1-11, IEC 60601-2-10, ISO 10993-5, ISO 10993-10.
12. Customer Service
24-Month Limited Warranty
Lifetime Technical Support
+1(678)829-7256
support@iauvon.com

35


Adobe PDF Library 16.0.3 Adobe InDesign 17.0 (Windows)

Related Documents

Preview AUVON TENS & EMS Device User Manual and Quick Guide
Explore the AUVON TENS & EMS Device (Model TUP429) with this quick guide and user manual. Learn about pain relief, muscle stimulation, operation, and safety for effective use.
Preview AUVON TU2224-A User Manual: TENS and Powered Muscle Stimulator Guide
Comprehensive user manual for the AUVON TU2224-A TENS and Powered Muscle Stimulator. Learn about its features, operating instructions, electrode placement, troubleshooting, and maintenance for effective pain relief and muscle stimulation.
Preview AUVON TENS & EMS Unit Quick Guide and User Manual - Model AS8016
Comprehensive quick guide and user manual for the AUVON TENS and Powered Muscle Stimulator Model AS8016. Learn how to operate the device, understand TENS and EMS therapies, proper pad placement for various body areas, battery charging, troubleshooting, and safety precautions for effective pain relief and muscle stimulation.
Preview AUVON TENS & EMS Device User Manual AS8016 for Pain Relief and Muscle Stimulation
Comprehensive user manual for the AUVON AS8016 TENS and EMS device, providing detailed operating instructions, pad placement suggestions for various body parts, safety precautions, troubleshooting, and product specifications for effective pain relief and muscle stimulation.
Preview AUVON TU3424-F TENS & EMS Device User Manual and Quick Guide
Comprehensive user manual and quick guide for the AUVON TU3424-F TENS & EMS Device, detailing operation, modes, pad placement, safety precautions, and troubleshooting.
Preview AUVON AS1080 TENS and Muscle Stimulator User Manual
Discover the AUVON AS1080 TENS and Muscle Stimulator, a dual-channel device for effective pain relief and muscle stimulation. This comprehensive user manual guides you through operation, safety, and troubleshooting for optimal results.
Preview AUVON AS8012C TENS and Muscle Stimulator User Manual | Pain Relief Guide
Comprehensive user manual for the AUVON AS8012C TENS and Muscle Stimulator. Learn about its features, operating instructions, safety precautions, and troubleshooting for effective pain relief and muscle stimulation.
Preview AUVON TENS & EMS Device Quick Guide and User Manual - Model AS1080
This AUVON TENS & EMS Device Quick Guide and User Manual (Model AS1080) provides comprehensive instructions for safe and effective pain relief. Learn how to operate, maintain, and troubleshoot your Transcutaneous Electrical Nerve Stimulation (TENS) and Electrical Muscle Stimulation (EMS) unit for temporary relief of sore and aching muscles.