1. Communication Methods
The EP600 energy storage system connects to the IOT controller. Inverter information is accessible via the mobile APP through Bluetooth or WiFi, allowing for remote control of the inverter's working mode. System working information (power generation, alarms, status) is uploaded to the server via WiFi. Users can utilize the APP to view and control the device, which requires registering an account and binding the device by scanning the EP600's QR code.
The IOT controller supports the following communication methods:
Communication Method | Remark |
---|---|
Wi-Fi | Standard |
Bluetooth | Standard |
2. Overview
Diagram of the IOT Controller. Part 1 is labeled 'User Button'.
LED Indicators:
- WiFi Indicator: Flashes when WiFi is not connected; remains solid when connected.
- Bluetooth Indicator: Flashes when Bluetooth is not connected; remains solid when connected.
Buttons:
- Menu Button: To factory reset the controller, press and hold this button until all LED indicators flash.
- Reset Button: (Function not explicitly detailed in this section, but listed as a button.)
3. Installation
[Danger] Before drilling, ensure you avoid any embedded water pipes or electrical lines within the wall to prevent hazards.
Installation Steps:
- Drill 2 pilot holes in the wall. Refer to figures 6.14.1 (recommended position) and 6.14.2 (drill hole specifications, showing dimensions of 24mm and 2-Ø50.0) for drill position and hole size. The depth of the hole should be 26mm.
- Hammer the expansion anchor into the drilled hole until it is flush with the wall. Figure 6.14.3 visually guides this step.
- Align the IOT controller bracket with the wall holes. Use a Phillips screwdriver to fasten the bracket to the wall with two self-tapping screws into the expansion anchors. Figure 6.14.4 illustrates this attachment.
- Align the controller's buckle over the bracket's U-slot and push the controller downwards until it snaps securely into place. Figures 6.14.5 and 6.14.6 show the controller being mounted onto the bracket.
4. Safety Instructions
- The IOT controller is exclusively for use with BLUETTI products.
- Do not place the device near heat sources or in environments with flammable or explosive gases and smoke.
- Do not attempt to replace any internal components; no user-replaceable parts are included in the packaging.
- [Warning] Do not insert foreign objects into any ports of the device. Use with care and keep children away from the device.
- In case of fire, use a dry powder fire extinguisher.
5. Connection and Operations
Connection Steps:
- Connect the M19 self-locking 9-pin communication cable to the EP600's Link Port 1.
- Turn on the EP600; the IOT controller will power on automatically.
- Open the BLUETTI APP to perform operations.
Download the "BLUETTI" APP from the App Store (for Apple device users) or Google Play (for Android device users). This application allows for remote control of the power system. (Refer to section 8.2 for details on downloading and installing the BLUETTI APP).
The IOT controller can be remotely controlled via Bluetooth or WiFi. To access the device remotely, launch the downloaded "BLUETTI" application, tap the "Login" icon, and proceed to "Register". Fill in your BLUETTI account and related information to complete registration. (Refer to section 8.3 for details on registering a BLUETTI account).
Diagram Descriptions:
- Figure 6.15: Image showing BLUETTI EP400 and EP600 energy storage units.
- Figure 6.16: Screenshots of the BLUETTI app sign-up interface, illustrating the process of creating an account with email and password.
- Figure 6.17: Displays an example email containing a verification code for BLUETTI account creation.
BLUETTI will send a verification code to your registered email account. Enter this code to activate your BLUETTI account.
6. Firmware Upgrade
6.11.1 Upgrade via USB Drive
The EP600 inverter supports firmware upgrades via a USB drive to maximize its performance and avoid failures caused by firmware errors.
Upgrade Steps:
- Insert the USB drive into a USB port on your computer.
- Download the upgrade file, unzip it, and store it on the USB drive.
- Insert the USB drive into the USB port on the EP600.
- Power on the EP600.
- The firmware upgrade starts automatically once the upgrade files are detected. The controller will indicate it is upgrading DSP and ARM components.
- The buzzer will beep once after the firmware is updated successfully. Please unplug the USB drive promptly; otherwise, the EP600 may report a USB Format Error.
- Pair the EP600 with the BLUETTI app to check the firmware version on your phone.
If any of the following occurs, please try the solutions provided. If the symptom persists (for 5 times), contact the BLUETTI support team; they will respond within 48 business hours.
* Please contact BLUETTI customer service.
Error Description | Solution |
---|---|
USB Upgrade Failed. | Please contact the BLUETTI support team. |
USB Format Error. |
|
Firmware version not updating or abnormal. | Please download the latest upgrade files. If the symptom persists, contact the BLUETTI support team. |
7. Compliance Information
FCC Compliance Statement:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RF Exposure Warning Statements:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment shall be installed and operated with a minimum distance of 20cm between the radiator & body.
Innovation, Science and Economic Development Canada Compliance:
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.
French Translation: L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) L' appareil ne doit pas produire de brouillage; (2) L' appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d' en compromettre le fonctionnement.
IC Radio Frequency Exposure Statement:
This equipment complies with IC exposure limits set forth for an uncontrolled environment. This equipment shall be installed and operated with minimum distance 20cm between the radiator & body.
French Translation: Cet équipement est conforme aux limites d'exposition IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et le corps.