Renaissance™ Commercial F-Series™ RACCYB Packaged Air Conditioners
Friedrich Commercial Air
Capacities: 3, 4, 5, 6 Tons
Standard Features
- Convertible Airflow
- MicroChannel evaporator and condenser coils
- PlusOne® ServiceSmart features
- Qwik-Change Flex-Fit Rack
- Qwik-Slide Blower Assembly
- Qwik-Clean Drain Pan
- 3-5 Ton models include one single-stage compressor
- 6 Ton models include one two-stage compressor
- Designed for A2L refrigerant R-454B
Diagrams and Preliminary Information
The RACCYB packaged air conditioner is a self-contained unit designed for outdoor installation. The unit is rectangular in shape and features a prominent fan assembly on the top. It includes various access panels on its sides for service and maintenance, such as those for the compressor, blower, heat exchanger, and drain pan. Key dimensions are provided in a schematic, indicating overall height, width, and depth, along with connection points for supply and return air. For example, typical dimensions include a height of approximately 77 7/8 inches, a width of 44 5/8 inches, and a depth of 42 5/8 inches.
Preliminary Information
Note: Preliminary information based on preliminary estimates. Not a representation of energy use or efficiency of these models. Information provided for pre-sale purposes only. Products will not be produced or shipped until ratings are certified to the Department of Energy.
Unit | RACCYB036 | RACCYB048 | RACCYB060 | RACCYB072 |
---|---|---|---|---|
Gross Cooling Capacity | 35,600 [10.43] Btu/h [kW] | 47,200 [13.83] Btu/h [kW] | 61,000 [17.87] Btu/h [kW] | 72,000 [21.10] Btu/h [kW] |
Net Cooling Capacity | 34,200 [10.02] Btu/h [kW] | 45,500 [13.33] Btu/h [kW] | 57,000 [16.71] Btu/h [kW] | 68,500 [20.10] Btu/h [kW] |
Net Sensible Capacity | 24,000 [7.03] Btu/h [kW] | 31,800 [9.33] Btu/h [kW] | 39,500 [11.58] Btu/h [kW] | 48,000 [14.07] Btu/h [kW] |
Net Latent Capacity | 10,200 [2.99] Btu/h [kW] | 13,700 [4.02] Btu/h [kW] | 17,500 [5.13] Btu/h [kW] | 20,500 [6.01] Btu/h [kW] |
EER2 (EER) | 10.6 | 10.6 | 10.6 | (11.2) |
SEER2 (IEER) | 13.4 | 13.4 | 13.4 | (14.8) |
Stages of Heating / Cooling | 2/1 | 2/1 | 2/1 | 2/2 |
Nominal Airflow | 1,200 [566] CFM [L/s] | 1,600 [755] CFM [L/s] | 2,000 [944] CFM [L/s] | 2,400 [1,133] CFM [L/s] |
Indoor Airflow | 1,175 [555] CFM [L/s] | 1,570 [741] CFM [L/s] | 1,825 [861] CFM [L/s] | 2,400 [1,133] CFM [L/s] |
Estimated Net Weight | 557 [253] lbs. [kg] | 580 [263] lbs. [kg] | 583 [264] lbs. [kg] | 582 [264] lbs. [kg] |
Estimated Shipping Weight | 595 [270] lbs. [kg] | 618 [280] lbs. [kg] | 621 [282] lbs. [kg] | 620 [281] lbs. [kg] |
Model Number Nomenclature
The model number is constructed using a specific nomenclature that defines its features and specifications.
Model Number Breakdown:
RACCYB036ACT102AA0 (Example)
1 - Brand: R = Friedrich
2, 3 - Unit Type: AC = Packaged AC
4 - Cabinet Type: C = Small Commercial
5 - Refrigerant: Y = R-454B
6 - Efficiency Level: B = Standard Efficiency, C = High Efficiency
7, 8, 9 - Capacity: 036 = 3 Ton, 048 = 4 Ton, 060 = 5 Ton, 072 = 6 Ton
10 - Major Series: A = 1st Design
11 - Voltage: J = 208-230 V, 1 PH, 60 Hz; C = 208-230 V, 3 PH, 60 Hz; D = 460 V, 3 PH, 60 Hz; Y = 575V, 3 PH, 60 Hz
12 - Drive: T = Direct Drive Standard Static Constant Torque; U = Direct-Drive High Static Constant Torque
13, 14 - Heat Capacity: 00 = No Heat; 10 = 10 kW; 15 = 15 kW; 20 = 20 kW; 24 = 24 kW
15 - Heat Configuration: 0 = No stages; 1 = 1 stage; 2 = 2 stage
16 - Control: A = Core Command™ (Non-Communicating); B = Core Command™ & Phase Monitor; C = Clear Control™ (DDC) & Phase Monitor; D = Clear Control™ (DDC) & Comfort Alert®
17 - Minor Series: A = 1st Design
18, 19, 20 - Option Code: AA0 (Example)
Option Code Character Highlighted
Option Code Character | 18 | 19 | 20 |
---|---|---|---|
Meaning | 18 - Features | 19 - Features | 20 - Features |
A | None | None | None |
B | LV = Louver Protection | LF = Low Ambient & Freeze Stat | EC = Economizer |
C | HA = Hinged Access | NP = Non-Powered Convenience Outlet | SS = Supply & Return Smoke Detector |
D | LV = Louver Protection, HA = Hinged Access | LF = Low Ambient & Freeze Stat, NP = Non-Powered Convenience Outlet | RS = Return Smoke Detector |
E | LV = Louver Protection, CC = Coil Coating | ||
F | LV = Louver Protection, HA = Hinged Access, CC = Coil Coating | ||
N | RH = Reheat | ||
P | LV = Louver Protection, RH = Reheat | ||
Q | RH = Reheat, HA = Hinged Access | ||
R | LV = Louver Protection, RH = Reheat, CC = Coil Coating | ||
S | LV = Louver Protection, RH = Reheat, HA = Hinged Access | ||
T | LV = Louver Protection, RH = Reheat, HA = Hinged Access, CC = Coil Coating | ||
3 = EC = Economizer, RS = Return Smoke Detector | |||
4 = SS = Supply & Return Smoke Detector, RS = Return Smoke Detector | |||
5 = EC = Economizer, SS = Supply & Return Smoke Detector, RS = Return Smoke Detector |
Note: Not all model/option combinations are available. Refer to the product specifications sheet or rapidspec.com for specific details.
Accessories
Note: Factory installation available for highlighted models.
Accessory | Model Number | Accessory | Model Number | Accessory | Model Number |
---|---|---|---|---|---|
Comfort Alert (1 Phase) DDC | RXRX-AZ03 | Fresh Air Damper, Motorized | RXRF-ACB1 | Electric Heater Kits | RXJJ-DC10JT |
Comfort Alert (1 Phase) Non-DDC | RXRX-AZ04 | Fresh Air Damper, Motorized (DDC) | RXRF-ACC1 | Electric Heater Kits | RXJJ-DC15JT |
Comfort Alert (3 Phase) DDC | RXRX-AZ01 | Low-Ambient Control Kit | RXRZ-A04 | Electric Heater Kits | RXJJ-DC20JT |
Comfort Alert (3 Phase) Non-DDC | RXRX-AZ02 | MERV 13 Filter | RXMF-M13A21616 | Electric Heater Kits | RXJJ-DC10CP |
Communication Card, BACnet | RXRX-AY01 | MERV 8 Filter | RXMF-M08A21616 | Electric Heater Kits | RXJJ-DC15CP |
Communication Card, LonWorks | RXRX-AY02 | Outdoor Coil Louver Kit | RXRX-ADD04C | Electric Heater Kits | RXJJ-DC20CP |
Concentric Adapter 3-4 Ton Drop | RXMC-DC01 | Power Exhaust (230V) Vertical | RXRX-CCF02C | Electric Heater Kits | RXJJ-DC24CP |
Concentric Adapter 5-6 Ton Drop | RXMC-DC02 | Power Exhaust (460V) Vertical | RXRX-CCF02D | Electric Heater Kits | RXJJ-DC10DNV |
Concentric Diffuser 3-4 Ton Drop | RXRN-AED1800 | Power Exhaust (230V) Horizontal | RXRX-CCF03C | Electric Heater Kits | RXJJ-DC15DNV |
Concentric Diffuser 3-4 Ton Flush | RXRN-AEF1800 | Power Exhaust (460V) Horizontal | RXRX-CCF03D | Electric Heater Kits | RXJJ-DC20DNV |
Concentric Diffuser 5-6 Ton Drop | RXRN-AED2000 | Power Exhaust (230V) Vertical RRS | RXRX-RCF02C | Electric Heater Kits | RXJJ-DC24DNV |
Concentric Diffuser 5-6 Ton Flush | RXRN-AEF2000 | Power Exhaust (460V) Vertical RRS | RXRX-RCF02D | ||
Convenience Outlet, Non-powered | RXRX-BN01 | Power Exhaust (230V) Horizontal RRS | RXRX-RCF03C | ||
Dual Enthalpy Kit, Honeywell | RXRX-BV01 | Power Exhaust (460V) Horizontal RRS | RXRX-RCF03D | ||
Dual Enthalpy Kit DDC, Honeywell | RXRX-BV02 | Return Smoke Detector (Field kit) | RXRX-BS01 | ||
Dual Enthalpy Optional Sensor, Siemens | PD555460 | Return/ Supply Smoke Detector (Field kit) | RXRX-BS02 | ||
Dual Enthalpy Optional Sensor, RRS Basic | PD555463 | Roofcurb Adapter | RXRX-DCCAE | ||
Economizer w/ Single Enthalpy (Downflow/Vertical) Honeywell | RXRD-01MCDAM3 | Roofcurb, 14" | RXKG-DCC14 | ||
Economizer w/ Single Enthalpy (Horizontal) Honeywell | RXRD-01MCHAM3 | Roofcurb, 24" | RXKG-DCC24 | ||
Economizer w/ Single Enthalpy (Downflow/Vertical) DDC, Honeywell | RXRD-01MCDBM3 | Room Humidity Sensor | RHC-ZNS4 | ||
Economizer w/ Single Enthalpy (Horizontal) DDC, Honeywell | RXRD-01MCH-BM3 | Room Temperature and Relative Humidity Sensor | RHC-ZNS5 | ||
Economizer w/ Single Enthalpy (Downflow/Vertical) Siemens | RXRD-11MCDAM3 | Wall Mounted Carbon Dioxide Sensor | RXRX-AR02 | ||
Economizer w/ Single Enthalpy (Horizontal) Siemens | RXRD-11MCHAM3 | Unfused Service Disconnect | RXRX-BP01 | ||
Economizer w/ Single Enthalpy (Downflow/Vertical) RRS Basic | RXRD-41MCDAM3 | UV-C Light Kit for 208/230V | RXRX-UVC22C | ||
Economizer w/ Single Enthalpy (Horizontal) RRS Basic | RXRD-41MCHAM3 | UV-C Transformer Kit for 460V/230V | RXRX-UVCTC | ||
Economizer w/ Single Enthalpy (Downflow/Vertical) No Controls | RXRD-31MCDAM3 | Single Point Wiring Kits, Single Phase | RXJX-AJ0601 | ||
Freeze Stat Kit | RXRX-AM05 | Single Point Wiring Kits, Three Phase | RXJX-AZ0601 | ||
Fresh Air Damper, Manual | RXRF-ACA1 |
Friedrich is a part of the Rheem family of brands. In keeping with its policy of continuous progress & program improvement, Friedrich reserves the right to make changes without notice.
© 2023 Rheem Manufacturing Company, all rights reserved. Friedrich trademarks are owned by Friedrich Air Conditioning LLC. Rheem trademarks owned by Rheem Manufacturing Company.
Form No. MFR-1128