User Manual: Air Abrasion System with Spray (CA-1)

Brand: COXO

Model: CA-1

1. Introduction

The Air Abrasion System with spray is a safe and reliable instrument designed to provide a very small abrasive flow, using water mist to restrain sand powder from scattering. It utilizes the power of compressed air to spray fine abrasive particles at high speed for quickly removing stubborn adhesions.

2. Safety

3. Intended Use

This product is intended for use by qualified dentists during dental treatment for:

4. Contraindications

This instrument cannot be used in the human oral cavity.

5. Choice of Powder

The powder should be dry and loose. Wet powder can be baked at 120°C for half an hour.

6. Product List

7. Device Overview

The device includes a Connector, Cap, Bottle for powders, Start/Stop button, Spray head, and a MAX/MIN indicator on the bottle.

8. Technical Specifications

Recommend working pressure 0.4MPa
Input water pressure 0.2MPa
Working pressure 0.3~0.6MPa
Spray nozzle diameter 1.0mm
Effective distance for spray 2mm~10mm
Powder spray <9g/min
Water spray > 20ml/min

9. Instruction and Operation

  1. Connect the connector to the pipe of the dental chair.
  2. Ensure the powder level does not exceed the "MAX" mark (approximately 6ml per mark).
  3. Adjust air and water pressure to the required range. Press the foot pedal and hold the start/stop button to begin operation.
  4. Release the foot pedal and start/stop button to stop operation.
  5. Turn off the water supply when not in use.

10. Maintenance

  1. After connecting the air source, run the instrument several times to remove residual powder and prevent blockage. Ensure the powder bottle is empty.
  2. Disconnect the connector from the dental chair pipe. Use a three-way syringe to blow air through the connector pipe to drain any remaining water.
  3. When not in use, store the instrument and powder in a dry place.

11. Cleaning, Disinfection and Sterilization

  1. Unscrew the bottle. Use a three-way syringe to empty any remaining powder and water from the instrument.
  2. Wipe the surface with a damp cloth.
  3. Remove the spray head and clean it with water. Use a three-way syringe to flush out any remaining powder, then dry the head with air.
  4. Use a three-way syringe to clean any remaining powder from the cap and connector.

12. Troubleshooting

Problem Solution
Spray head is blocked Unscrew the spray nozzle and flush it with water.
The hole of the main rod is blocked First unscrew the spray head. Use a tip to loosen the blockage, then press down the foot pedal and hold the start/stop button to discharge the blockage.
Air or water leaks Unscrew the spray head to check the sealing condition of the connection. If the O-ring is damaged, replace it.
The hole of the spray head is blocked Use a tip to clear the blockage.

13. Operating Environment, Storage and Transportation Conditions

Operating environment

Storage and Transportation conditions

14. Symbols

15. Guarantee

The Air Abrasion System with spray is guaranteed for 12 months from the date of purchase. The guarantee is valid for normal usage conditions. Any modification or accidental damage will void the guarantee.

Manufacturer: Foshan COXO Medical Instrument Co., Ltd.
No. 17, Guangming Ave., New Light Source Industrial Base, Nanhai National High-tech Zone, Foshan 528226, Guangdong P.R. China

EC REP: Lotus NL B.V.
Koningin Julianaplein 10, 1e Verd, 2595AA, The Hague, Netherlands.
E-mail: peter@lotusnl.com

Models: CA-1 Air Abrasion System With Spray, CA-1, Air Abrasion System With Spray, Abrasion System With Spray, System With Spray, Spray

PDF preview unavailable. Download the PDF instead.

Air-Abrasion-Unit-User-Manual Corel PDF Engine Version 16.1.0.843

Related Documents

Preview COXO PT Master Airflow Dental Scaler and Air Polisher User Guide
Comprehensive user guide for the COXO PT Master Airflow Dental Scaler and Air Polisher, detailing operation, maintenance, and safety features for dental professionals. Learn about its heated water function and optimal usage for dental hygiene.
Preview COXO CX235 Series Contra Angle Operation Manual
Comprehensive operation manual for COXO CX235 Series Contra Angle dental handpieces. Includes technical specifications, usage instructions, maintenance, lubrication, sterilization, and troubleshooting.
Preview COXO Scaler Tips User Manual: Installation, Use, and Sterilization Guide
Comprehensive user manual for COXO Scaler Tips, detailing model types, intended use, contraindications, installation, cleaning, disinfection, sterilization, and maintenance for dental professionals.
Preview COXO C-Smart Nova Endo Motor User Manual - Dental Equipment Guide
Comprehensive user manual for the COXO C-Smart Nova dental endo motor. Learn about safety, operation, maintenance, troubleshooting, and EMC compliance for this professional dental instrument.
Preview COXO C-SMART-I PILOT Endo Motors User Manual
User manual for the COXO C-SMART-I PILOT Endo Motors, detailing its features, operation, safety precautions, and technical specifications for dental professionals.
Preview COXO CX235 Contra Angle Operation Manual - Dental Handpiece Guide
Comprehensive operation manual for the COXO CX235 Contra Angle dental handpiece, covering specifications, usage, maintenance, sterilization, and troubleshooting.
Preview COXO SC-Pro Dental Endo Motor and Apex Locator User Manual
Comprehensive user manual for the COXO SC-Pro dental endodontic motor and apex locator, detailing its features, operation, and maintenance. Covers file selection, apex locator functions, multi-function mode, battery management, and troubleshooting.
Preview COXO CX207 High-Speed Dental Turbine Handpiece User Manual
This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of the COXO CX207 series high-speed dental turbine handpiece. It covers technical specifications, assembly, usage guidelines, and warranty information.