Industrial L3 Multi-Gigabit/10Gigabit Managed Ethernet Switch
IGS-6325-4T2X/IGS-6325-4UP2X/IGS-6325-5X1T
Quick Installation Guide
1. Package Contents
Thank you for purchasing PLANET L3 Multi-Gigabit/10Gigabit Industrial Managed Switch, IGS-6325-4T2X/IGS-6325-4UP2X/IGS-6325-5X1T. "Industrial Managed Switch" mentioned in this Quick Installation Guide refers to the above models.
IGS-6325-4T2X
Industrial L3 4-Port 2.5GBASE-T + 2-Port 10G SFP+ Managed Ethernet Switch
IGS-6325-4UP2X
Industrial L3 4-Port 2.5GBASE-T 802.3bt PoE + 2-Port 10G SFP+ Managed Ethernet Switch
IGS-6325-5X1T
Industrial L3 5-Port 10GBASE-X SFP+ + 1-Port 10GBASE-T Managed Ethernet Switch
Open the box of the Industrial Managed Switch and carefully unpack it. The box should contain the following items:
Item | IGS-6325-4T2X | IGS-6325-4UP2X | IGS-6325-5X1T |
---|---|---|---|
The Industrial Managed Switch | ● | ● | ● |
DB9 to RJ45 Interface RS232 Console Cable | ● | ● | ● |
Quick Installation Guide sheet | ● | ● | ● |
Wall Mounting Kit | ● | ● | ● |
RJ45 Dust Cap | 5 | 5 | 2 |
SFP Dust Cap | 2 | 2 | 5 |
If any of these are missing or damaged, please contact your dealer immediately. If possible, retain the carton including the original packing materials to enable you to repack the product in case there is a need to return it to us for repair.
2. Requirements
The Industrial Managed Switch provides remote login interface for management purposes. The following equipment is necessary for further management:
- Workstations running Windows XP/2003/2008/Vista/7/8/10/11, MAC OS X or later, Linux, UNIX, or other platforms compatible with TCP/IP Protocols.
- Workstations installed with Ethernet NIC (Network Interface Card).
- Serial Port Connection (Terminal): Workstations with COM Port (DB9) or USB-to-RS232 converter, and installed with a terminal emulator (e.g., Hyper Terminal, PuTTY, Tera Term).
- Serial cable: Connects the PC's RS232 serial port to the Industrial Managed Switch's console port.
- Ethernet Port Connection: Standard network (UTP) cables with RJ45 connectors.
- PC installed with a Web browser.
? It is recommended to use Chrome 98.0.xxx or above to access the Industrial Managed Switch.
3. Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch indicates an inlet power socket and consists of one green terminal block connector with 6 contacts. Please follow the steps below to insert the power wire.
1. Insert power wires
DC 9-48V, AC 24V (IGS-6325-4T2X & IGS-6325-5X1T)
[Diagram: Terminal block with contacts 1-6 labeled V1+, V1-, PWR1, Alarm, V2+, V2-, PWR2. Shows DC Input 9-48V, 4A max. and AC Input 24V, 2A max. Also shows Max. Fault Alarm Loading: 24V, 1A.]
IGS-6325-4T2X | IGS-6325-5X1T | |
---|---|---|
DC Input Voltage | 9-48V DC | 9-48V DC |
Max. DC Input Current | 3A | 4A |
AC Input Voltage | 24V AC | 24V AC |
Max. AC Input Current | 1.5A | 2A |
2. Insert power wires for IGS-6325-4UP2X
DC 48-54V (IGS-6325-4UP2X)
Dual power input is required for maximum PoE loading. Refer to user's manual for more details.
[Diagram: Terminal block with contacts 1-6 labeled V1+, V1-, PWR1, Alarm, V2+, V2-, PWR2. Shows DC Input 48-54V, 8.3A max. Also shows Max. Fault Alarm Loading: 24V, 1A.]
IGS-6325-4UP2X | |
---|---|
DC Input Voltage | 48-54VDC |
Max. DC Input Current | 8.3A |
⚠️ PWR1 and PWR2 must provide exactly the same DC voltage for power load balance while operating with dual power input.
3. Tighten wire-clamp screws
[Diagram: Terminal block pins labeled 1 (V1+), 2 (V1-), 3 (Power 1), 4 (V2+), 5 (V2-), 6 (Power 2).]
3.1 Grounding the Device
? The wire gauge for the terminal block should be in the range from 12 to 24 AWG.
? Please check the AWG Ampere specification before connecting PLANET Industrial Managed Switch.
Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device.
[Diagram: Terminal block showing "Earth Ground" connected to the GND pins (contacts 4 and 5). Shows DC Input 9-48V, 4A max. and AC Input 24V, 2A max. Also shows Max. Fault Alarm Loading: 24V, 1A.]
? LIGHTNING DAMAGE IS NOT COVERED UNDER WARRANTY.
4. Terminal Setup
To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Industrial Managed Switch.
[Diagram: IGS Industrial Managed Switch connected via RJ45 to DB9 RS232 Cable to a PC/Workstation with Terminal Emulation Software, showing Console Port and Serial Port.]
A terminal program is required to make the software connected to the Industrial Managed Switch.
1. Run terminal program
2. Configure COM port settings
- Baud: 115200
- Parity: None
- Data bits: 8
- Stop bits: 1
- Flow control: None
[Screenshot: COM1 Properties window showing Port Settings with Baud rate 115200, Data bits 8, Parity None, Stop bits 1, Flow control None.]
4.1 Logging on to the Console
Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display "running testing procedures". Then, the following message asks to log in user name and password. The factory default user name and password are shown as follows as the login screen in Figure 4-1 appears.
? IGS-6325-5X1T is used as a representative in all the following console screens.
Username: admin
Password: admin
[Screenshot: PuTTY terminal window showing login prompt for Username and Password, followed by "IGS-6325-5X1T#".]
The user can now enter commands to manage the Industrial Managed Switch. For a detailed description of the commands, please refer to the following chapters.
? 1. For security reason, please change and memorize the new password after this first setup.
? 2. Only accept command in lowercase letter under console interface.
4.2 Configuring IP Address via Console
IP Address: 192.168.0.100
Subnet Mask: 255.255.255.0
To check the current IP address or assign a new IP address to the Switch, please use the commands as follows
Display of the Current IP Address
1. At the "#" prompt, enter "show ip interface brief".
IGS-6325-Series # show ip interface brief
2. The screen displays the current IP address.
[Screenshot: PuTTY terminal window showing "show ip interface brief" command output, displaying VLAN 1 with IP Address 192.168.0.100/24, Method Manual UP.]
Configuration of the IP Address
3. At the "#" prompt, enter the following commands:
IGS-6325-Series# configure terminal
IGS-6325-Series(config)# interface vlan 1
IGS-6325-Series(config-if-vlan)# ip address 192.168.1.100 255.255.255.0
The previous command would apply the following settings for the Industrial Managed Switch.
IP Address: 192.168.1.100
Subnet Mask: 255.255.255.0
[Screenshot: PuTTY terminal window showing the commands entered to configure the IP address.]
4. Enter "exit" command twice to return to the global configuration mode.
5. Repeat step 1 to check if the IP address has changed.
4.3 Storing the current switch configuration
1. At the "#" prompt, enter the following command and press .
# copy running-config startup-config
[Screenshot: PuTTY terminal window showing "copy running-config startup-config" command execution and confirmation of saving.]
If the IP is successfully configured, the Industrial Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the Industrial Managed Switch through the new IP address.
? If you are not familiar with the console command or the related parameter, enter “help" anytime in console to get the help description.
5. Starting Web Management
The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address.
For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
[Diagram: PC with IP Address 192.168.0.x connected via RJ45/UTP Cable to IGS Industrial Managed Switch with IP Address 192.168.0.100.]
5.1 Logging in to the Industrial Managed Switch
1. Use Chrome 98.0.xxx or above for Web browser and enter IP address https://192.168.0.100 to access the Web interface.
2. Enter the default user name "admin" and password “admin” (or the changed password) as shown in Figure 5-2.
Default IP Address: 192.168.0.100
Default Username: admin
Default Password: admin
[Screenshot: Authentication required dialog box for https://192.168.0.100 with Username and Password fields, and Login/Cancel buttons.]
3. After entering the password, the main screen appears.
[Screenshot: PLANET Web interface showing the main screen with a Switch-Menu and Sub-menu. The main content area displays "Welcome to PLANET IGS-6325-5X1T Industrial L3 5-Port 10GBASE-X SFP+ + 1-Port 10GBASE-T Managed Ethernet Switch". Company contact information is also displayed.]
The Switch Menu on the top of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides. The Switch Menu always contains one or more buttons, such as "System", "Switching", "Routing", "QoS", "Security", "Ring" and "Maintenance".
[Image: Switch Menu bar with buttons: System, Switching, Routing, QoS, Security, Ring, Maintenance.]
[Image: Detailed menu structure showing categories like Management, Port Management, VLANs, IP Configuration, IP Status, etc.]
[Image: Detailed menu structure showing categories like Access Security, AAA, Port Authentication, Ring Wizard, ERPS, Switch Maintenance, Diagnostics.]
In addition to the menu items that IGS-6325-4T2X/IGS-6325-5X1T presents above, the IGS-6325-4UP2X which supports IEEE 802.3bt PoE also provides a specific menu item for related PoE functional settings.
[Image: Sub-menu items for PoE (PoE System Configuration, Port Configuration, etc.) and ONVIF (ONVIF Device Search, etc.).]
? If you are not familiar with Switch functions or the related parameter, press “Help icon” anytime on the Web page to get the help description.
5.2 Saving Configuration via Web
To save the current configuration as a startup configuration, click the "Save" icon, and then the startup configuration file will be loaded automatically across a system reboot.
1. Click the Save icon on the top Switch Menu bar.
[Image: Part of the Switch Menu bar showing a "Save Configuration" button with a floppy disk icon.]
2. Press the “Save Configuration” button.
[Button: Save Configuration]
[Text: Save Running Configuration to startup-config]
3. Alternatively, click Maintenance, and then select Save Startup Config.
[Image: Dropdown menu under "Switch Maintenance" showing options like Web Firmware Upgrade, Save Startup Config, Configuration Download, etc.]
6. Restoring Default Configuration
IP address has been changed or admin password has been forgotten
To reset the IP address to the default IP address "192.168.0.100" and the user password to factory default (default password is admin), press the recessed reset button on the front panel for about 10 seconds. After the device reboots, you can log in the management Web interface within the same subnet of 192.168.0.xxx with default password. Please note that all the previous settings will disappear after resetting the switch to factory default.
[Diagram: Front panel of IGS-6325-5X1T showing ports and a recessed "Reset Button".]
[Diagram: Front panel of IGS-6325-4T2X showing ports and a recessed "Reset Button".]
[Diagram: Front panel of IGS-6325-4UP2X showing ports, PoE status indicators, and a recessed "Reset Button".]
7. Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
PLANET online FAQs:
https://www.planet.com.tw/en/support/faq
Switch support team mail address:
Industrial User's Manual:
https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=IGS-6325&view=3#list
(Please select your switch model name from the Product Model drop-down menu)
Copyright © PLANET Technology Corp. 2023. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.