User Guide for LANCOM Systems models including: 883 VoIP, Telephony High Speed Internet and Wi-Fi, High Speed Internet and Wi-Fi, 883 VoIP, Internet and Wi-Fi

Hardware Quick Reference Guide LANCOM 883 VoIP

LANCOM 883 VoIP Hardware Quick Reference Guide

Connectors, Ports, HWS, Initial Operation, Installation, Technical Details

LANCOM Systems GmbH

Quick reference guide

LANCOM 883 VoIP: LANCOM Systems GmbH


File Info : application/pdf, 1 Pages, 509.71KB

PDF preview unavailable. Download the PDF instead.

HWS 883-plus-VoIP EN
LANCOM 883+ VoIP Quick Reference Guide

Gigabit Ethernet 10/100/1000

VDSL

a

b

a VDSL interface Use the supplied DSL cable for the IP-based line to connect the VDSL interface and the provider's telephone socket. For more information, please contact your Internet service provider.
b Ethernet interfaces Use an Ethernet cable to connect one of the interfaces ETH 1 to ETH 4 to your PC or a LAN switch.
c Analog interfaces Connect analog terminal devices to the analog interfaces either directly via RJ11, or with the help of the enclosed TAE adapters. Further adapters are optionally available.
d Configuration interface Use a serial configuration cable to connect the serial interface (COM) to the serial interface of the device you want to use for configuring / monitoring (separately available).

TE / NT

NT

Analog 2/4 Analog 1/3

c

d

ISDN 1

ISDN 2

e

e ISDN interfaces ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. ISDN 2: Internal (NT) ISDN bus.
A 100-Ohm resistor for line termination is switchable in LCOS.
f USB interface You can use the USB interface to connect a USB printer or a USB memory stick.
g Power After connecting the cable to the device, turn the bayonet connector 90° clockwise until it clicks into place. Use only the supplied power adapter.

fg

Cloud-ready

4

Please observe the following when setting up the device A Do not rest any objects on top of the device A For devices to be operated on the desktop, please attach the
adhesive rubber footpads A In case of wall mounting, use the drilling template as supplied

A Keep the ventilation slots on the side of the device clear
LANCOM 1681V
of obstruction A Rack installation with the optional LANCOM Rack Mount
(separately available)

Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide! Operate the device only with a professionally installed power supply at a nearby power socket that is freely accessible at all times.

Power Online VDSL ISDN Status ETH 1 ETH 2 ETH 3 ETH 4 VPN
MOUNTING AND CONNECTING THE DEVICE LANCOM, LANCOM Systems, LCOS, LANcommunity and Hyper Integration are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their owners. This document contains statements relating to future products and their attributes. LANCOM Systems reserves the right to change these without notice. No liability for technical errors and / or omissions. 111906/11/21
TECHNICAL DETAILS

LANCOM 883+ VoIP

a bc d e f ghi j

a Power

Off Green, permanently*
Red / green blinking
Red blinking 1x green inverse blinking* 2x green inverse blinking* 3x green inverse blinking*
b Online
Off Green, permanently Red, permanently

Device switched off Device operational, resp. device paired / claimed and LANCOM Management Cloud (LMC) accessible Configuration password not set. Without a configuration password, the configuration data in the device is unprotected. Charge or time limit reached Connection to the LMC active, pairing OK, device not claimed Pairing error, resp. LMC activation code not available LMC not accessible, resp. communication error
WAN connection inactive WAN connection active WAN connection error

c DSL

Off Green, permanently Green, flickering Red, flickering Red / orange, blinking Orange, blinking Orange, permanently Green, blinking
d Analog

Interface deactivated DSL connection active DSL data transfer DSL transfer error DSL hardware error DSL training DSL sync DSL connecting

Off Green, permanently Orange, blinking Green, blinking

Interface deactivated Interface activated Incoming call Connection active

*) The additional power LED statuses are displayed in 5-seconds rotation if the device is configured to be managed by the LANCOM Management Cloud.

e ISDN

Off Green, permanently Green, flickering Red, flickering Red / orange, blinking

Interface deactivated D-channel active ISDN data transfer ISDN transfer error ISDN hardware error

f ETH
Off Green, permanently
Green, flickering

No networking device attached
Connection to network device operational, no data traffic
Data transmission

g WLAN
Off
Green, permanently
Green, blinking

No Wi-Fi network defined or Wi-Fi module deactivated. The Wi-Fi module is not transmitting beacons.
At least one Wi-Fi network is defined and Wi-Fi module activated. The Wi-Fi module is transmitting beacons.
DFS scanning or other scan procedure

h VoIP
Off Green, permanently
Red, permanently
Red or green, inverse flashing

No SIP accounts defined or VCM is off
All defined and active SIP accounts (outgoing) were successfully registered
Not all defined and active SIP accounts were registered (possibly still in process)
Number of currently used lines (connecting or connected)

i VPN
Off Green, permanently Green, flashing

VPN connection inactive VPN connection active VPN connecting

j Reset
Reset button

Operated e.g. with a paper clip a short press: Restart the device a long press: Reset the device

Hardware

Power supply Power consumption Environment Housing
Number of fans

12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection Max. ca. 18 W Temperature range 0­40 °C; humidity 0­95 %; non-condensing Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; measures 210 x 45 x 140 mm (W x H x D) One quiet fan

Interfaces

WAN: VDSL2
Wi-Fi
ETH USB ISDN 1 / ISDN 2 Analog 1 / Analog 2 Analog 3 / Analog 4 Config (Com) / V.24

a VDSL2 as per ITU G.993.2; profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a, 35b a VDSL2 vectoring as per ITU G.993.5 (G.vector) a Compatible to VDSL2 from Deutsche Telekom a VDSL Supervectoring as per ITU G.993.2 (Annex Q) a Compatible to U-R2 from Deutsche Telekom (1TR112) a ADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO, ITU G.992.3, and ITU G.992.1 a Supports just one virtual connection at a time in ATM (VPI-VCI pair)
a Frequency band: 2400-2483.5 MHz (ISM) or 5150-5825 MHz (restrictions vary between countries)
a Radio channels 2.4 GHz: Up to 13 channels, max. 3 non-overlapping (2.4-GHz band) a Radio channels 5 GHz: Up to 26 non-overlapping channels (channels available vary
according to country regulations; DFS for automatic dynamic channel selection required)
4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode. Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically disabled in the LCOS configuration.
USB 2.0 hi-speed host port for connecting USB printers (USB print server), serial devices (COM-port server) or USB drives (FAT file system)
ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. ISDN 2: Internal (NT) ISDN bus.
Use the cable of your analog devices to connect them with the analog interfaces. If necessary use the adapters from the LANCOM Analog Adapter Set.
Serial configuration interface/COM-port (8-pin mini-DIN): 9,600 - 115,200 baud, suitable for optional connection of analog/GPRS modems. Supports internal COM-port server and provides transparent asynchronous serial-data transfer via TCP.

WAN protocols

VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without DHCP), RIP-1, RIP-2, VLAN

ISDN

DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD

Declaration of Conformity

Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance with Directives 2014/30/EU, 2014/53/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc

Package content

Manual Cable Adapters

Quick Reference Guide (DE/EN); Installation Guide (DE/EN) 1 DSL cable for an IP-based line, 4.25 m 2 TAE adapters (RJ11 - TAE)

Power adapter

External power supply adapter (230 V); NEST 12 V / 2 A DC/S; barrel / bayonet (EU), LANCOM item no. 111303

This product contains separate open-source software components which are subject to their own licenses, in particular the General Public License (GPL). The license information for the device firmware (LCOS) is available on the device`s WEBconfig interface under "Extras > License information". If the respective license demands, the source files for the corresponding software components will be made available on a download server upon request.



References

Adobe PDF Library 15.0 Adobe InDesign 16.3 (Windows)