Rohnson R-91216 Dehumidifier

Thank you for choosing Rohnson. For proper operation, please read and keep this manual carefully.

Operation Area

Notes: The dehumidifier has rollers to aid placement. Do not attempt to roll the dehumidifier on carpet or over objects. Otherwise, water may spill out from the bucket or the dehumidifier may get stuck by the objects.

Safety Precautions

WARNING: Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater). Do not pierce or burn. Be aware that refrigerants may not contain an odour. The maximum refrigerant charge amount: 55 g. When the machine malfunctions, do not repair it yourself. Please contact a professional organization or a professional trained maintenance personnel or a service organization recommended by the supplier for repair!

Caution, risk of fire

Parts Name

Front Side

Back Side

Check Before Operation

Before operation, please first check whether the float is properly placed. Below are the checking steps:

  1. Hold the handles on both sides of the water bucket and pull it out following the arrow direction.
  2. Check whether the float in the water bucket is properly placed. It might have been moved a little after long-time transportation. If it's not placed properly, move it to the correct position by hand. Please remove the handle and check it.

Operation Method

Indicator Lights

Notes:

Basic Functions of the Buttons

Power Button or Stand by

Press this button to turn the dehumidifier on/off.

Humidity Settings

Set humidity, the range is 30%-80%. In normal mode, press left or right arrows to set humidity level.

Sleep Mode

Press the Sleep button to turn on the sleep function. While the machine is still working in any mode, all lights are off except the sleep light, water full light, and child lock light. Press any key in sleep mode to perform functions and wake up.

Air Cleaner

If you choose the compressor to stop working and the unit works as an air purifier only.

Auto Swing button

Press the Auto Swing button and the corresponding indicator will light up. The louver will start to swing automatically.

Child Lock

Long press the Auto Swing button and Air clean button. Again, long press for 5 seconds to unlock.

Fan Speed Button

Pressing this button can set fan speed circularly as: High, Low. The corresponding indicator will be on for each fan speed.

Timer Button

Press this button to set Timer On or Timer Off (Timing range 01~24h).

Dehumidify Mode Button

Press this button to select different kinds of working modes. After each pressing of this button, the mode will switch among the below options:

Dry Cloths button

In this option, the unit works to dry your clothes. The fan speed is set to HIGH automatically. In this option, you cannot set the humidity; the unit works.

Other Instructions

  1. Alarm Warning: If the bucket is full or not locked into place, a buzzer will go off for 20s to remind you to empty the bucket or put it back into the correct place.
  2. Auto Stop: When the bucket is full, removed, or not placed correctly, or the humidity is 5% lower than the set humidity, the unit will automatically stop.
  3. Memory Function: If power is lost, all control settings are remembered. So when power is restored, the unit will start back up in the settings it was in when power was lost.
  4. Full of water light: This indicates that the bucket is full or removed or not placed correctly.

Drainage Option

Option 1: Emptying Manually

Notes:

  1. Hold the handles on both sides of the water bucket and pull it out following the arrow direction. (Attention: Pull out the bucket carefully in case the water may spill out from the bucket and onto the floor.)
  2. Empty the bucket by grasping the handle on the top of the bucket with one hand and grasping the bottom of the bucket with the other hand.
  3. Replace the bucket in the dehumidifier according to the arrow direction.

Option 2: Gravity Drain Hose

  1. Hose is provided, so the user shall prepare it in advance. [Size: The hose thread should have an outer diameter of 10 mm and length 1 meter]
  2. Remove the bucket from the unit as instructed.
  3. Thread the drain hose onto the nozzle and make sure it's securely locked.
  4. Replace the bucket. Make sure the drain hose goes through the bucket's drain hole and is placed downward. Lead the hose to the floor drain and then cover the hole with a lid. Note that the drain hose should not be pressed, otherwise water cannot be drained out.

Note: When you want to take off the drain hose, prepare a receptacle to collect water from the nozzle.

Set an air clean filter to a dehumidifier

Notes: The lifespan of the ionic and carbon filter is based on the environmental air, normally it replaces after 1 year. If it is dirty, clean up dust or debris with a brush and dry it in the sunshine.

Clean and Maintenance

Warning:

1. Grille and Case

To clean the case: When there is dust on the case, use a soft towel to dust it off; When the case is very dirty (greasy), use mild detergent to clean it. To clean the grille: Use a dust catcher or brush.

2. Water Bucket

Every few weeks, clean the bucket to prevent the growth of mold, mildew, and bacteria. Use a soft brush to clean the bucket and then rinse it.

Warning:

Check Before Use-season

Long-time Storage

If you will not use the dehumidifier for a long time, we suggest that you follow the steps below to maintain the unit in good condition:

Troubleshooting

Not all the following problems are malfunctions.

Problem Possible Causes
Dehumidifier is not operating. Controls can not be set.
  • Unit is operating in an area where temperature is higher than 32°C or lower than 5°C.
  • Bucket is full.
Noise suddenly rises during operation.
  • Power Noise will supplyrise problem. If compressor has just started.
  • Unit is placed on uneven floor.
Humidity does not drop.
  • Area to be dehumidified is too large. The capacity of your dehumidifier may not be adequate.
  • Doors are open.
  • There might be some device producing vapor in the room.
Little or no effect in dehumidifying
  • Room temperature is too low.
  • Humidity level may be improperly set.
  • If unit is operating in a room where temperature is from 5 to 15°C, it will start to defrost automatically. Compressor will stop for a brief period of time (fan will operate in high fan speed). When unit finishes defrosting, it will be back to normal operation.
When first operated, the air emitted has musty-odor. Due to temperature rising of heat exchanger, the air may have some strange smell at the beginning.
Unit has noises. There might be some noise if unit is operating on wooden floor.
Swooshing sound is heard. Normal. This is the sound of the flow of refrigerant.

Problem of Water Leakage.

Problem Possible Causes Solution
When using drain hose, there is water in the bucket.
  • Examine the drainage joint.
  • Drain hose is not correctly installed.
  • Drain hose is not correctly installed.
  • Connect the drainage joint well.
  • Clear the obstacle from the drain hose.
  • Remove the drain hose and replace it. Be sure that the hose is correctly installed.

Dehumidifier does not start.

Problem Possible Causes Solution
Bucket full indicator is lit up.
  • Bucket is not properly placed.
  • Water is full in the bucket.
  • Bucket has been removed.
  • Humidity is set too high.
  • Empty the bucket and replace it.
  • If you want the air drier, press the - button to lower the for unit to dehumidify continuously.

Unit's Malfunction Codes

Display Code "E2": Temperature and Humidifier Sensor is damaged

Defrost procedure

Please note if the ROOM temperature is less than 24°C, the unit will start defrost function!

Dehumidifier does not dry air as intended.

Problem Possible Causes Solution
Bad dehumidifying performance
  • Check whether there is any obstacle around the unit.
  • Air filter is dusty and blocked.
  • Doors and windows are left open.
  • Room temperature is too low.
  • Make sure there is no curtain, shutter or furniture that blocks the dehumidifier.
  • Clean the filter.
  • Make sure all doors and windows and other openings to the outside have been closed.
  • Warm temperature is good for dehumidification. Low temperature will reduce the unit's working effect. This unit should be working in a place where temperature is above 5°C.

Disposal Information

IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002/96/EC.

At the end of its working life, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection centre or to a dealer providing this service.

Disposing of a household appliance separately avoids possible negative consequences for the environment and health, deriving from inappropriate disposal and enables the constituent materials to be recovered to obtain significant savings in energy and resources. As a reminder of the need to dispose of household appliances separately, the product is marked with a crossed-out wheeled dustbin.

Models: R-91216 Dehumidifier True Lon And Health Clean, R-91216, Dehumidifier True Lon And Health Clean, True Lon And Health Clean, Lon And Health Clean, And Health Clean, Health Clean

File Info : application/pdf, 14 Pages, 509.58KB

PDF preview unavailable. Download the PDF instead.

R-91216-True-Ion-Health-Clean-IM-EN-06.03.2023

References

Microsoft Word για το Microsoft 365

Related Documents

Preview Rohnson R-9916W Genius 16 Wi-Fi ION & UV-C Dehumidifier User Manual
Comprehensive user manual for the Rohnson R-9916W Genius 16 Wi-Fi ION & UV-C dehumidifier, covering safety instructions, operation, features, maintenance, troubleshooting, and technical specifications.
Preview Rohnson R-9920 Genius 20 Wi-Fi ION & UV-C Dehumidifier User Manual
Comprehensive user manual for the Rohnson R-9920 Genius 20 Wi-Fi ION & UV-C dehumidifier, covering safety instructions, operation, maintenance, troubleshooting, and technical specifications.
Preview Rohnson R-9916W Genius 16 Ion & UV-C Dehumidifier Instruction Manual
Instruction manual for the Rohnson R-9916W Genius 16 Ion & UV-C dehumidifier, covering operation, safety precautions, maintenance, troubleshooting, and technical specifications.
Preview Rohnson R-9920 Genius Wi-Fi Health & Clean Dehumidifier Instruction Manual
This instruction manual provides detailed information on operating, maintaining, and troubleshooting the Rohnson R-9920 Genius Wi-Fi Health & Clean dehumidifier. It covers safety precautions, parts identification, operational methods, drainage options, cleaning, and technical specifications.
Preview Rohnson R-9920 Genius 20 Ion & UV-C Dehumidifier Instruction Manual
Comprehensive instruction manual for the Rohnson R-9920 Genius 20 Ion & UV-C dehumidifier, covering operation, safety, maintenance, and troubleshooting. Learn how to use, care for, and resolve issues with your dehumidifier.
Preview Rohnson R-9920 Genius Wi-Fi Health & Clean Dehumidifier User Manual
Comprehensive user manual for the Rohnson R-9920 Genius Wi-Fi Health & Clean dehumidifier, covering safety instructions, device operation, features, maintenance, troubleshooting, and technical specifications.
Preview Rohnson R-9920 Genius Wi-Fi Health & Clean Dehumidifier User Manual
Comprehensive user manual for the Rohnson R-9920 Genius Wi-Fi Health & Clean dehumidifier, covering safety instructions, operation, maintenance, troubleshooting, and specifications.
Preview Rohnson R-9920 Genius Wi-Fi Health & Clean Dehumidifier User Manual
Comprehensive user manual for the Rohnson R-9920 Genius Wi-Fi Health & Clean dehumidifier, covering safety instructions, operation, features, maintenance, and troubleshooting.