User Guide for ZKTECO models including: HORUS, Second-Generation Facial Recognition Terminal, Facial Recognition Terminal, Recognition Terminal, HORUS, Terminal

HORUS Quick Start Guide V1.0 ...

foC5mjjiSfrQ82IgVozfexCx81tzUzvfn6zfBCAu

Index of /public/uploads/all/

PDF preview unavailable. Download the PDF instead.

foC5mjjiSfrQ82IgVozfexCx81tzUzvfn6zfBCAu
Quick Start Guide
HORUS
Version: 1.2 Date: November 2019

Device Overview
Front Flash Near-infrared
Camera

Side

Microphone

Speaker

5 inch Screen

Fixing hole

Fixing hole

Infrared sensors
Rear

Bottom

Type-C power interface
SIM-Card port

Power
Type-C power interface & OTG debugging interface Reset button

1

Fingerprint & RFID (Optional)

Rear

Front

Side

TCP/IP and RS485 extend port
(Horus E1-RFID, Horus E1-FP has the port)

Fingerprint Sensor & ID/MF Card read area

Bottom

Port Connection

Bottom

GND 485+ 485TX+ TXRX+ RX-

RS485 Ethernet

Type-C power interface
Reset Button

Note:

1. The port on the back is used to DM10(RS485) and TCP/IP connection; 2. Not all the devices have the function with , the real product prevails.

2

Device Installation

1. Installation Environment
a. Recommended location

Install the device indoors at least 10 feet

2M

(3m) away from window, and 6.5 feet (2m)

from light source. It is not recommended

3M

to install on the windows or in outdoor.

b. Not recommended locations

Direct Sunlight Outdoor

Direct Sunlight through window

Indirect Sunlight through window

Too close to light source

2. Installation Steps
a. Mounting on the wall Step 1: Put the mounting template sticker onto the wall, and drill holes
according to the mounting paper. Step 2: Fix the back plate onto the wall using wall mounting screws. Step 3: Insert the device into back plate. Step 4: Use security screw to fasten the device to back plate.
1
Baseline
10

1.55m 1.5m 1.5m-1.8m
1.3m 1.5m 1.8m

0.5-0.7m
3

0.5m 0.7m

2

3

4

b. Mounting on the desktop holder
Step 1: Screw the back plate to the desktop holder. Step 2: Insert the back plate into device. And use security screw to fasten
the device to back plate.

1

2

put it on the table

c. Mounting on the glass door
Step 1: Attach the double-sided tape to the back panel. Then attach the back plate to the glass door.
Step 2: Fix the device to the back plate. Use security screw to fasten the device to back plate.

1

2

Double-sided tape 4

d. Mounting on the wall through 86 box
Step 1: Install the 86 box (or Single Gang box) into the wall. Step 2: Fix the back plate to the adaptor board (86 box and Singer Gang
has different adaptor board) with two screw and nuts. Step 3: Fix the adaptor board onto the 86 box (or Single Gang box) using
four wall mounting screws. Step 4: Insert the device into back plate. Step 5: Use security screw to fasten the device to back plate.

4 3

1

2 86 box

Back plate Adaptor board

Wall

5

Power Connection

Recommended power supply: 12V ± 10%, at least 2000mA. Please use the supplied Type-C power plug.
5

Equipment Connection
1. Ethernet Connection
Connect the device and computer software over an Ethernet cable. An example is shown below:

TX+

PC

TX-

8 7 6 5 4 3 2 1

RX+

RX-

Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0

IP address: 192.168.1.130 Subnet mask: 255.255.255.0

Note:

1. In LAN, IP addresses of the server (PC) and the device must be in the same network segment.
2. It only supports Horus E1-RFID and Horus E1-FP.

2. RS485 Connection and Extend DM10

GND

GND

485+

485A

485-

485B

DC12V

DM10

Door Sensor

Lock Smoke detector

Alarm Reader Exit Button

Note:
1. DM10 needs to be powered separately. 2. The address of the DM10 DIP switch defaults to . 1 2 3 4 3. It only supports Horus E1-RFID and Horus E1-FP. 4. Not all devices support all function: Door Sensor, Lock, Smoke Detector,
Alarm, Reader and Exit Button, it's based the Horus rmware, please con rm with technical support before the sales.

6

Quick Start

User Registration User Authentication Verified View records

Network settings
Click > [System Settings] > [Netword settings] / [Cloud service settings] to enter the settings interface, and to set parameters of the ethernet, WiFi, 4G and cloud service.

User Mgt.

ATT Events

Access Settings

Attendanc e Search

Data Mgt.

System Settings Network settings Date and time ATT parameters Cloud service settings Serial port setting Display settings Sound settings Biometric parameters Auto-Testing Advanced settings About device Restart

Network settings Ethernet Ethernet settings Wi-Fi Wi-Fi Settings Mobile Network Mobile Network Switch 4G/3G/2G Comm connection Comm connection settings IP Address 0.0.0.0

Cloud service settings Server Server type

ADMS

Enable domain name Server address Server port

0.0.0.0 8081

Enable proxy server

Open

HTTPS

Restart

manually

to

complete setup

Note: Plug the SIM card into your device, turn on the 4G/3G/2G function, and you can use it directly.
7

User registration
1. Register on the device
Click > User Mgt. > to register new user. Enter user name, ID, register face, fingerprint, badge number (fingerprint and ID card are optional), and password.
User Management

User Mgt.

ATT Events

Access Settings

Attendanc e Search

Attendanc e Search

Data Mgt.

L

1.5m 1.5m-1.8m

0.5-0.7m

Note:
1. It's recommended to register multiple administrators.
2. It's recommend enroll user's face in 0.5~0.75m distance, it's good for 1.5~1.8m height person.

2. Register on the software (BioTime 8.0)
Please set the IP address and cloud service server address on the device. a. Click [Device] > [Device] > [Add] to add the device to the software.
When the device has set the server address and port, in can be added automatically.
8

b. Click [Personnel] > [Employee] > [Employee] > [Add] to register users in the software.
c. Synchronize personnel on the software to devices in the corresponding area.
d. In the personnel list, select an employee (or employees) and click [More] > [Synchronize to Device] to access the confirmation interface for synchronizing. For more details, please refer to the BioTime 8.0 User Manual.
Note: The icons or in the standby interface indicates that the network connection or the server is abnormal. Please check the network cable and network connection.
3. Register on the phone
Once BioTime 8.0 software installation, users could enroll face via broswer application on their own mobile phone. Register visible light comparison photos to verify and punch on the visible light device. a. Choose [Personnel] > [Employee] > [Bio-photo] > [QR Code] to access
the QR Code getting interface. b. Scan the QR code via broswer APP and enroll face user, user could input
the http://server_ip_address:server_port/v1Register/ on the broswer APP manually as well. The following interface is entered after successful scanning:
9

User Authentication
Terminal could detect face in 0.3m to maximum 3m distance. The device switches to face verification interface automatically once it detect bright of environment change. The verification result shows as right image.

Verify successfully! 2018-08-03 20:44:43
Tom 1

Verification is successful
View records
View records on the software
Click [Attendance] > [Report] on the software to view the records.