Lutron Caséta Wireless In-Wall Switch Quick-Start Guide
Welcome and thank you for purchasing a Caséta Wireless in-wall switch. In order to control your lights from an app or remote, you'll need to replace an existing switch with a Caséta Wireless in-wall switch. We hope you enjoy the convenience of Caséta Wireless!
Double Your Warranty
Love Caséta Wireless products? Have ideas for making them better? Tell us what you think and we'll extend your warranty by 1 year. Visit www.casetawireless.com/register.
Contents Supplied
- In-wall switch (PD-5WS-DV)
- LUT-MLC* load adapter
- Wire connectors (5)
- Screws (2)
Tools You'll Need
- Flat-head screwdriver
- Phillips-head screwdriver
- Pliers
*Note: A LUT-MLC may be required to ensure proper function with CFL, LED, ELV, and fluorescent lighting. Please see instructions for installing the LUT-MLC that can be found on page 2 of this install guide. The instructions can also be found by visiting www.casetawireless.com/lutmic.
Installing Your Switch: Installation for Lights with One Wall Switch (Single-Pole)
Step 1: Turn Power Off at Circuit Breaker!
⚠️ WARNING: SHOCK HAZARD May result in serious injury or death. Turn off power at circuit breaker or fuse before installing.
Diagram Description: Shows a circuit breaker panel with a switch being moved to the 'OFF' position.
Step 2: Remove Existing Switch from Wall
Remove the wallplate from the switch. Then, remove the switch and pull it away from the wall. Disconnect all three wires* from the switch.
Diagram Description: Illustrates removing the wallplate, then the old switch from the electrical box, and finally disconnecting wires from the old switch.
Step 3: Remove Side Sections (If Necessary)
Diagram Description: Shows different configurations of switches in a multi-gang electrical box, indicating where side sections might need to be removed for ganging. Options shown are 'Not Ganged', 'End of Gang', and 'Middle of Gang'.
Step 4: Connect the Switch
Important Note: Maximum wattage rating is dependent on location in ganging application. See the chart below for maximum load information.
Maximum load derating chart (120 V~ 50/60 Hz) Not Ganged End of Gang Middle of Gang LED, CFL, & Fluorescent¹ 5 A 4 A 3 A Incandescent, Halogen, & ELV 600 W 450 W 350 W MLV² 600 VA/475 W 450 VA/350 W 350 VA/275 W General Purpose Fan 3 A 3 A 3 A Maximum load derating chart (277 V~ 50/60 Hz) Not Ganged End of Gang Middle of Gang LED, CFL, & Fluorescent¹ 5 A 4 A 3 A Incandescent, Halogen, & ELV 1350 W 1100 W 800 W MLV² 1350 VA/1075 W 1100 VA/875 W 800 VA/625 W ¹The in-wall switch is UL Listed for use with all magnetic and electronic fluorescent ballasts.
²The maximum lamp wattage is determined by the efficiency of the transformer, with 70%-85% as typical. For actual transformer efficiency, contact either the fixture or transformer manufacturer. The total VA rating of the transformer(s) shall not exceed the VA rating of the in-wall switch.
Wiring Instructions:
- Connect the bare copper (or green) "ground" wire from the wallbox to the green wire on the switch using a wire connector.
- Connect the load wire from the wallbox to the red wire on the switch using a wire connector.
- Connect the hot wire from the wallbox to the black wire on the switch using a wire connector.
- Cap off the blue wire on the switch using the small wire connector.*
*Note: The blue wire is only used in 3-way installations. See www.casetawireless.com/3way for more information.
*Note: A LUT-MLC may be required to ensure proper function with CFL, LED, ELV, and fluorescent lighting. Please see instructions for installing the LUT-MLC that can be found on page 2 of this install guide. The instructions can also be found by visiting www.casetawireless.com/lutmlc.
Diagram Description: Shows the new switch with labeled wires (Green/Ground, Red/Load, Black/Hot, Blue/Cap). It illustrates connecting these wires to the corresponding wires from the wallbox.
Step 5: Mount the Switch
Use the screws provided to mount the switch into the electrical box.
Diagram Description: Shows the switch being secured into the wall box with screws.
Step 6: Attach the Wallplate
Attach the adapter to the switch using the screws provided and snap on the wallplate. (If you installed the switch next to other switches or dimmers, you'll need to install a wallplate with the correct size/number of openings to accommodate all the devices.)
Diagram Description: Illustrates attaching the adapter plate and then snapping the final wallplate into place. A 'snap' sound is indicated.
Step 7: Turn Power On at Circuit Breaker
Diagram Description: Shows a circuit breaker panel with a switch being moved to the 'ON' position.
CAUTION Use only with permanently installed lighting loads or with general purpose fan loads.
Codes
Install in accordance with all national and local electrical codes.
Grounding
When no "grounding means" exist in wallbox, the National Electrical Code (NEC®) allows a control to be installed as a replacement if 1) a nonmetallic, noncombustible faceplate is used with nonmetallic attachment screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI). When installing a control according to these methods, cap or remove green wire before screwing control into wallbox.
FCC/IC Information
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user's authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warranty
For warranty information, please visit www.casetawireless.com/warranty.
Supported Loads
120 V~ Loads
- LED: up to 5 A
- CFL: up to 5 A
- Incandescent/Halogen: up to 600 W
- MLV: up to 600 VA/475 W
- ELV: up to 600 W
- Fluorescent: up to 5 A
- General Purpose Fan: up to 3 A
277 V~ Loads
- LED: up to 5 A
- CFL: up to 5 A
- Incandescent/Halogen: up to 1350 W
- MLV: up to 1350 VA/1075 W
- ELV: up to 1350 W
- Fluorescent: up to 5 A
Using Your Caséta Wireless Kit (Sold Separately)
With a Smartphone or Tablet (Smart Bridge Required, Sold Separately)
The Caséta Wireless switch can be controlled from a smartphone when used with the Lutron Smart Bridge. If you are using the switch and remote control with the Lutron Smart Bridge, follow the instructions below.
Note: If you are using the switch and remote control with another manufacturer's bridge, please refer to that manufacturer's instructions for set-up.
Download the Lutron® App
Search for "Lutron Caseta" on Google Play or the App Store.
Diagram Description: Shows icons for Google Play and Apple App Store, and the Lutron logo.
Launch the Lutron® App
The Lutron app will walk you through setting up your devices.
Use the Lutron App to Complete ALL Remaining Steps
Add devices (Pico remote controls, Dimmers, Shades), Control three ways, Schedule your lights, Connect while away.
Diagram Description: Shows icons representing adding devices, controlling in different ways, scheduling, and remote connection.
Without a Smartphone or Tablet (Smart Bridge Not Required)
Pairing the Switch and Pico Remote Control
Step 1: Press and Hold "Off" Button on the Switch
Hold for 6 seconds until the LED starts blinking.
Diagram Description: Shows the in-wall switch with an 'OFF' button being pressed and held. An indicator light is shown blinking.
Step 2: Press and Hold "Off" Button on Remote
Hold for 6 seconds until lights flash 3 times.
Diagram Description: Shows a Pico remote control with an 'OFF' button being pressed and held. Indicator lights are shown flashing.
Repeat steps to pair other Pico remote controls.
Using Your Controls
Diagram Description: Shows basic operation of the in-wall switch (ON/OFF) and the Pico remote control (ON/OFF). It also labels the FASS (Front Accessible Service Switch).
Replacing Light Bulbs Using FASS
Pull the FASS out on the in-wall switch to remove power at the light socket.
Diagram Description: Illustrates pulling out the FASS switch to disconnect power to the light fixture.
Important notes:
- For indoor use only.
- Operate between 32 °F (0 °C) and 104 °F (40 °C).
For advanced features, tips for using Caséta Wireless products with CFLs and LEDs, the complete Caséta Wireless product line, and more, please visit www.casetawireless.com/features.
Troubleshooting
Symptoms | Probable Cause and Action |
---|---|
Light does not turn on or in-wall switch LED does not light up. |
|
Light does not respond to Pico remote control. |
|
Light stays on when the switch is turned off. |
|
Proper bulb operation requires a LUT-MLC (included in the package with the switch). Please visit www.casetawireless.com/lutmlc for installation instructions.
Go to www.casetawireless.com/support for additional troubleshooting suggestions.
Installing the LUT-MLC in a Load Fixture or Junction Box
Diagram Description: Shows a junction box with wires labeled 'Load' and 'LUT-MLC'. It illustrates connecting one lead of the LUT-MLC to the neutral (white) wire and the other lead to the switched hot (black) wire.
- Connect one lead of the LUT-MLC to the neutral (white) wire.
- Connect the other lead of the LUT-MLC to the switched hot (black) wire.
Device Ratings
In-wall switch
PD-5WS-DV
120/277 V~ 50/60 Hz