® GE APPLIANCES

NCHC*5S Horizontal Coils

Product Specifications

Residential Product Specifications

A diagram shows a rectangular, silver-colored metal cabinet, representing the horizontal indoor coil unit. The front panel is partially open, revealing the internal coil structure with fins and tubing.

Read Carefully. Keep These Instructions.

Model Number Guide

The model number NCHC*5S can be broken down as follows:

Component Description
BRANDN-GE
PRODUCTC-COIL
APPLICATIONH-HORIZONTAL
ENCLOSUREC-CASED
NOMINAL CAPACITY (1000 BTU/HR)18 = 1.5 TON, 24 = 2.0 TON, 30 = 2.5 TON, 36 = 3.0 TON, 42 = 3.5 TON, 48 = 4.0 TON, 60 = 5.0 TON
REFRIGERANT5 = R454B
METERING DEVICET = TXV
MATCHING CABINET WIDTHA-14.5, B-17.5, C-21, C-24.5
MAJOR/MINOR REVISIONXX
DESIGNATIONS = SPECIFIC

Approvals

Applications

Coil Construction

Total Corrosion Technology Designed Coil

Refrigerant Line Connections

Braze-Free/Press Fitting Flexibility

Anti-Microbial Drain Pans

R-454B Check/Expansion Valve

Low GWP Refrigerant Detection System

The system consists of an RDS detection sensor on the coil and an RDS control in the furnace.

Refrigerant Detection System (RDS) Coil Sensor

Optional Accessories

Refrigerant Detection System (RDS) Blower Control Board

Note: For furnaces manufactured without the RDS Blower Control Board. Connects to the RDS sensor furnished with the coil.

Non-Communicating Blower Control Board

Non-Communicating Blower Control Board and Sensor can be used with any non-communicating 24 volt furnace.

Standard Features (RDS System)

Note: Refer to the Installation Instructions for additional information.

Cabinet

Furnace Match-Up

Specifications

1.5 to 2 Ton Models

Size Nominal Tonnage Refrigerant Type Furnace Cabinet Matching Letter Width Coil & Furnace Cabinet Width (in.) Connections (Liquid line OD sweat - in.) Connections (Suction line OD sweat - in.) Connections (Condensate drain FPT - in.) Net face area (ft.²) Indoor Coil Rows Indoor Coil Fins (in.) Shipping Data (lbs.)
18A1.5R-454BA14-1/23/87/8(2) 3/43.521944
24A2R-454BA14-1/23/87/8(2) 3/43.531346
24B2R-454BB17-1/23/87/8(2) 3/44.6721950

2.5 to 3 Ton Models

Size Nominal Tonnage Refrigerant Type Furnace Cabinet Matching Letter Width Coil & Furnace Cabinet Width (in.) Connections (Liquid line OD sweat - in.) Connections (Suction line OD sweat - in.) Connections (Condensate drain FPT - in.) Net face area (ft.²) Indoor Coil Rows Indoor Coil Fins (in.) Shipping Data (lbs.)
30A2.5R-454BA14-1/23/87/8(2) 3/44.3331656
30B2.5R-454BB17-1/23/87/8(2) 3/44.6731354
36A3R-454BA14-1/23/87/8(2) 3/43.531348
36B3R-454BB17-1/23/87/8(2) 3/44.6721849
36C3R-454BC213/87/8(2) 3/45.8321856

3.5 to 4 Ton Models

Size Nominal Tonnage Refrigerant Type Furnace Cabinet Matching Letter Width Coil & Furnace Cabinet Width (in.) Connections (Liquid line OD sweat - in.) Connections (Suction line OD sweat - in.) Connections (Condensate drain FPT - in.) Net face area (ft.²) Indoor Coil Rows Indoor Coil Fins (in.) Shipping Data (lbs.)
42B3.5R-454BB17-1/23/87/8(2) 3/45.7841367
42C3.5R-454BC213/87/8(2) 3/45.8331367
48B4R-454BB17-1/23/87/8(2) 3/45.7831361
48C4R-454BC213/87/8(2) 3/45.8331360

5 Ton Models

Size Nominal Tonnage Refrigerant Type Furnace Cabinet Matching Letter Width Coil & Furnace Cabinet Width (in.) Connections (Liquid line OD sweat - in.) Connections (Suction line OD sweat - in.) Connections (Condensate drain FPT - in.) Net face area (ft.²) Indoor Coil Rows Indoor Coil Fins (in.) Shipping Data (lbs.)
60C5R-454BC213/87/8(2) 3/47.2231370
60D5R-454BD24-1/23/87/8(2) 3/47.9431379

Air Resistance

The following tables provide air resistance data for various models at different air volumes.

Model No. Air Volume (cfm) Total Resistance (Dry Coil in. w.g.) Total Resistance (Wet Coil in. w.g.)
NCHC18A2000.020.02
NCHC18A4000.050.06
NCHC18A6000.090.11
NCHC18A8000.150.17
NCHC18A10000.220.25
NCHC24A4000.040.05
NCHC24A6000.090.11
NCHC24A8000.150.19
NCHC24A10000.230.29
NCHC24A12000.320.40
NCHC24A14000.500.28
NCHC24B4000.030.04
NCHC24B6000.070.09
NCHC24B8000.110.15
NCHC24B10000.170.24
NCHC24B12000.230.34
NCHC24B14000.300.45
NCHC30A4000.040.05
NCHC30A6000.090.10
NCHC30A8000.150.17
NCHC30A10000.240.27
NCHC30A12000.340.38
NCHC30A14000.450.51
NCHC30B4000.020.02
NCHC30B6000.050.06
NCHC30B8000.090.11
NCHC30B10000.140.16
NCHC30B12000.190.23
NCHC30B14000.260.30
NCHC36A8000.150.18
NCHC36A10000.220.27
NCHC36A12000.300.39
NCHC36A14000.410.48
NCHC36A16000.530.63
NCHC36B8000.080.10
NCHC36B10000.110.16
NCHC36B12000.160.21
NCHC36B14000.210.27
NCHC36B16000.270.35
NCHC36C8000.060.08
NCHC36C10000.100.13
NCHC36C12000.150.18
NCHC36C14000.190.23
NCHC36C16000.240.31
NCHC42B8000.100.10
NCHC42B10000.140.18
NCHC42B12000.200.25
NCHC42B14000.260.31
NCHC42B16000.340.36
NCHC42B18000.420.47
NCHC42C8000.060.06
NCHC42C10000.090.10
NCHC42C12000.150.16
NCHC42C14000.180.21
NCHC42C16000.260.28
NCHC42C18000.310.38
NCHC48B10000.140.16
NCHC48B12000.190.23
NCHC48B14000.250.29
NCHC48B16000.300.38
NCHC48B18000.380.42
NCHC48C12000.160.19
NCHC48C14000.210.26
NCHC48C16000.270.30
NCHC48C18000.330.39
NCHC48C20000.390.49
NCHC60C12000.150.16
NCHC60C14000.200.23
NCHC60C16000.250.29
NCHC60C18000.310.36
NCHC60C20000.400.44
NCHC60C22000.480.54
NCHC60D14000.120.16
NCHC60D16000.160.20
NCHC60D18000.200.24
NCHC60D20000.240.30
NCHC60D22000.290.36
NCHC60D24000.340.42

Unit Dimensions and Furnace/Coil Combined Dimensions

Diagrams illustrate the unit dimensions and airflow. A top view shows airflow paths. A front view details connection points (liquid line, suction line, condensate drains) and the RDS coil sensor wiring inlet, along with key dimensions. An end view shows cabinet openings.

Unit Dimensions - In. (mm)

A diagram shows a coil unit with dimensions labeled A and B. Dimension B is shown as 33 inches (838 mm).

Furnace/Coil Combined Dimensions

Coil Size A (in.) A (mm) B (in.) B (mm)
18A26-1/267359-1/21511
24A26-1/267359-1/21511
24B
30B
36A26-1/267359-1/21511
36B
36C
42C
30A31-1/288064-1/21638
42B
48B
48C
60C31-1/288064-1/21638
60D

Detailed Dimensions Table

SIZE A (Height) B (Width) C D E F G H
in.mmin.mmin.mmin.mmin.mmin.mmin.mmin.mm
NCHC18A26-1/267314-1/23681333013-3/83403-1/4831-3/4443-3/8864-3/8111
NCHC24A26-1/267314-1/23681333013-3/83403-1/4831-3/4443-3/8864-3/8111
NCHC24B26-1/267317-1/24441640616-3/84163-1/4831-3/4443-3/8864-3/8111
NCHC30A31-1/280014-1/23681333013-3/83403-1/4831-3/4443-3/8864-3/8111
NCHC30B26-1/267317-1/24441640616-3/84163-1/4831-3/4443-3/8864-3/8111
NCHC36A26-1/267314-1/23681333013-3/83403-1/4831-3/4443-3/8864-3/8111
NCHC36B26-1/267317-1/24441640616-3/84163-1/4831-3/4443-3/8864-3/8111
NCHC36C26-1/26732153319-1/249519-7/85053-1/4831-3/4443-3/8864-3/8111
NCHC42B31-1/280017-1/24441640616-3/84163-1/4831-3/4443-3/8864-3/8111
NCHC42C26-1/26732153319-1/249519-7/85053-1/4831-3/4443-3/8864-3/8111
NCHC48B31-1/280017-1/24441640616-3/84163-1/4831-3/4443-3/8864-3/8111
NCHC48C26-1/26732153319-1/249519-7/85053-1/4831-3/4443-3/8864-3/8111
NCHC60C31-1/28002153319-1/249519-7/85053-1/4831-3/4443-3/8864-3/8111
NCHC60D31-1/280024-1/26222358423-3/85943-1/4831-3/4443-3/8864-3/8111

Note on Airflow: 1 Optional right-hand airflow requires a field fabricated 6 in. (152 mm) spacer in-between the furnace and coil.

All specifications and illustrations are subject to change without notice and without incurring obligations. Printed in the U.S.A.

Models: NCHC24AT5S, NCHC30AT5S, NCHC36AT5S, NCHC5S Horizontal Coils, NCHC5S, Horizontal Coils, Coils

File Info : application/pdf, 10 Pages, 116.25KB

PDF preview unavailable. Download the PDF instead.

sp0crsyk5ym32ttmai10

References

Adobe InDesign 20.0 (Windows) Acrobat Distiller 24.0 (Windows)

Related Documents

Preview GE Appliances NAM*P1*5S Multi-Position Air Handler Installation Instructions
Comprehensive installation guide for the GE Appliances NAM*P1*5S Multi-Position Air Handler. This manual provides detailed instructions on wiring, installation clearances, condensate drain setup, duct system integration, refrigerant line brazing, electrical connections, and start-up procedures. It includes safety warnings and important information for both professional installers and homeowners.
Preview GE Appliances NS15A Installation Instructions
Comprehensive installation instructions for the GE Appliances NS15A Single Stage Air Conditioner, covering safety, electrical, refrigerant piping, and start-up procedures.
Preview GE Appliances NS16A*5 Single Stage Air Conditioner Installation Instructions
Comprehensive installation instructions for the GE Appliances NS16A*5 Single Stage Air Conditioner. This guide covers safety precautions, installation steps, refrigerant piping, electrical wiring, start-up procedures, and maintenance recommendations.
Preview GE Appliances NS15A*5 Single Stage Split System Air Conditioner Product Specifications
Detailed product specifications for the GE Appliances NS15A*5 single stage split system air conditioner, including model number guide, approvals, applications, refrigerant system details, compressor information, cabinet specifications, electrical data, and expanded sound data. This document provides technical information for installation and operation.
Preview GE Appliances NS16A*5 Single Stage Split System Air Conditioner Product Specifications
Detailed product specifications, features, and model number guide for the GE Appliances NS16A*5 single-stage split system air conditioner, featuring R454B refrigerant.
Preview GE Appliances NS16H Single Stage Heat Pump Installation Instructions
Comprehensive installation guide for the GE Appliances NS16H Single Stage Heat Pump, covering safety precautions, unit placement, refrigerant piping, electrical wiring, start-up procedures, and maintenance.
Preview GE Appliances Air Conditioners: Features and Specifications
Explore the features and specifications of GE Appliances' air conditioners, including inverter, two-stage, and single-stage models. Learn about R454B refrigerant, durable service valves, quiet operation, and corrosion-resistant coils.
Preview Up to $500 GE Consumer Rebate - BrandSource Exclusive Offer
Details on the BrandSource exclusive offer for up to $500 back on select GE appliances purchased between November 10, 2019, and December 5, 2019. Includes rebate tiers, qualifying appliance lists for refrigeration, ranges, wall ovens, cooktops, microwaves, dishwashers, washers, dryers, and warming drawers.