Fire Special Thermal Camera Quick Operation Manual

Introduction

Thank you for purchasing this product, please read this manual before use. After reading, please carefully store for future reference. We hope this product will meet your expectations.

IMPORTANT

This manual is a general manual for a series of products, which means that the specific model of the product you receive may be different from the manual picture; please refer to the physical receipt. This user manual is organized for the convenience of users to use and understand the company's products. We will do our best to ensure the accuracy of the content of this manual, but still cannot guarantee the completeness of the content of this manual, because our products have been continuously updated and upgraded. The company reserves the right to modify at any time without prior notice.

FCC WARNING

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

The device has been evaluated to meet general RF Exposure requirement. The device can be used in Portable Exposure condition without restriction.

Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made.

Considerations

Danger

  1. Charge the battery as instructed in the Guide and follow the charge steps and precautions. Incorrect charging can cause heating or damage of the battery or even cause personal injury.
  2. Never attempt to open or disassemble the battery; if the battery leaks and the liquid enters eyes, immediately flush the eyes with water and then take necessary medical care.

WARNING

  1. When using the equipment, please try to keep it stable and avoid violent shaking.
  2. Do not use or store the instrument in an environment beyond the permitted operating temperature or storage temperature of the equipment.
  3. Do not direct the equipment at high intensity thermal radiation sources, such as the sun, lasers, spot welders, etc.
  4. Do not plug the hole in the device.
  5. Do not knock, throw or vibrate instruments and accessories to avoid damage.
  6. Do not disassemble the machine by yourself, which may cause damage to the equipment and loss of warranty rights.
  7. Do not use dissolved or similar liquids on equipment or cables, which may cause damage to the equipment.
  8. Please do not use the equipment in an environment that exceeds the operating temperature of the equipment, which may cause damage to the equipment.
  9. Please follow the following measures when wiping the equipment:
    • Non-optical surface: When necessary, you can use a clean and soft cloth to wipe the non-optical surface of the thermal camera.
    • Optical surface: Please avoid staining the optical surface of the lens when using the thermal camera, especially avoid touching the lens with your hands, because the sweat on your hands will leave traces on the lens glass and may corrode the optical coating layer on the glass surface. When the surface of the optical lens is contaminated, use professional lens paper to carefully wipe.
  10. Do not place the battery in a high temperature environment or near high temperature objects.
  11. Do not short-circuit the positive and negative terminals of the battery.
  12. Do not place the battery in a humid environment or water.

CAUTION

  1. Do not expose the equipment to dust or damp environment. When used in an environment with water, water should be avoided on the instrument. Cover the lens when not in use.
  2. When the equipment is not in use, please place the instrument and all accessories in a special packaging box.

Storage and Transportation

Storage:

A packaged product shall be stored in a well-ventilated and clean environment with a temperature range of -40°C to 85°C, a relative humidity not exceeding 95%, and free of condensate and corrosive gas.

Transportation:

During transportation and circulation, the product shall be protected from rain and water and placed flatwise. It shall be protected from violent vibration and impact. During handling, it shall be handled with care and cannot be tossed.

Product Introduction

This product is specially designed for fire protection infrared thermal imager, mainly used for fire fighting and rescue, fire inspection, rescue and disaster relief operations. It can guide firefighters to rescue personnel under harsh smoke and high temperature fire site conditions, find the fire source, prevent firefighters from straying into high temperature dangerous areas, and ensure the property and life safety of the masses. This product is usually handheld, both detection type and rescue type. Use battery power, with infrared image display, temperature indication, temperature analysis, picture or video playback and other functions.

Introduction to Product Parts

The following are the main parts of the product:

  • 1: Power / OK button
  • 2: Clear/Right-click
  • 3: Menu/Left button
  • 4: Trigger key
  • HDMI Port
  • Type-C Port

Operation Steps (Quick Operation Guide)

  1. Place the battery in the battery compartment.
  2. Hold down the power switch for 2 seconds.
  3. Set the language (for first use).
  4. Enter the real-time preview and point the thermal camera at the target.
  5. Select the photo or video mode and press the photo button to save the image or recorded video.
  6. Press the button to perform other operations.

Interface Description

  1. Sensitivity mode: Low sensitivity temperature measurement range (0°C to 650°C, 500°C to 1200°C, 1000°C to 2000°C); High sensitivity temperature range (-20°C to 150°C).
  2. Data transmission status: Status display when connecting PC and HDMI for data transmission.
  3. Electronic magnification: In the menu bar, select [Menu Icon] and press the OK key to display the current magnification status, including: 2x, 4x, 8x.
  4. Data recording status: Displays the status of the photo or video recording mode.
  5. PLUS image mode: In non-basic fire mode, the "plus" icon is displayed on the left side of the image mode.
  6. Image mode: Display different image mode states, mainly including 6 modes: basic fire, black and white, fire, search and rescue, heat detection, standard.
  7. Internal electronic overheat flashing indicator: Visual warning indicates that the device has overheated and stopped working; it flashes red for 1 minute after shutdown. [Overheat Warning Icon]
  8. Temperature alarm: When the high temperature and low temperature alarm is triggered, the icon flashes until the alarm is over. [Temperature Alarm Icon]
  9. Battery status: Divided into green, yellow, red display; low power flashing. [Battery Status Icon]
  10. Digital temperature indicator: Open the center point in the analysis menu [Center Point Icon] and display the temperature of the center point.
  11. Temperature bar: Dynamic vertical propulsion according to the temperature change of the current center point.
  12. Color strip: Changes with the temperature measurement area and has a temperature scale.

Considerations

  1. Avoid direct sunlight on the object to be observed.
  2. Do not directly expose the device to high-intensity thermal radiation sources, such as the sun, lasers, and spot welders.
  3. During the observation, make sure the target is clear; otherwise, you may get wrong measurement results.
  4. Proper analysis of IR images requires technical knowledge of the application.

Guide for Common Faults and Troubleshooting

PhenomenonCausesMeasures
Unable to power on the deviceInsufficient batteryUse the battery after recharging.
Bad contact of the batteryRemove the battery, put it back in the battery compartment, and install it in place.
The external power supply is not plugged in properlyUnplug the power plug, plug it back in, and push it into place.
The displayed battery power differs greatly from the actual usageBattery deadReplace with a fully charged battery.
Battery life is upReplace the battery.
Image is not clearThe lens is dehydrated or contaminatedUse professional equipment to clean the lens.
Inaccurate temperature measurementParameters related to temperature measurement are incorrectly setChange parameter settings or restore default parameter values.
Non-uniformity correction was not performed for a long timeIn the expert menu, press the shutter once in the temperature measurement and debugging interface, hear the shutter sound, and perform a non-uniformity correction.
Power on immediately measure the temperatureIn order to ensure the accuracy of temperature measurement, we recommend that you turn on the thermal camera and wait 5-10 minutes to start the temperature measurement.
File cannot be storedNo calibration for a long timeFor accurate temperature measurements, we recommend that you send the camera back for calibration once a year.
File cannot be storedThe internal memory card is abnormal. ProcedureDelete pictures and video files from your gallery. Shut down and restart the storage card. Format the storage card on the device or replace it with a new storage card.
Models: 2AKU5-ZC17, 2AKU5ZC17, ZC17 Fire Special Thermal Camera, ZC17, Fire Special Thermal Camera, Special Thermal Camera, Thermal Camera, Camera

File Info : application/pdf, 17 Pages, 230.77KB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8305360 WPS 文字

Related Documents

Preview Wuhan Guide Sensmart ZC08 HD Thermal Camera Quick Start Guide
This guide provides essential information for operating the Wuhan Guide Sensmart ZC08 HD high-performance thermal camera. It covers product features, detailed operation steps, interface descriptions, safety warnings, storage, transportation, and troubleshooting for professional infrared thermometry applications.
Preview Guide Sensmart T120 Series: Entry-Level Portable Thermal Camera
Discover the Guide Sensmart T120 Series, an entry-level portable thermal camera designed for efficient building diagnostics, HVAC, and electrical system inspections. It features a 120x90 IR module, 10,800 pixels, a 2.4-inch display, and a rugged, ergonomic design for professional use.
Preview Guide Sensmart ZG14 Thermal Imager Quick Start Guide
Concise guide to operating and configuring the Guide Sensmart ZG14 thermal imager, covering button functions, menu settings, charging, and video output. Includes FCC warnings and usage notices.
Preview Guide Sensmart ZG38 Vision Enhancement Imager Quickstart Guide
Get started quickly with the Guide Sensmart ZG38 Vision Enhancement Imager. This guide covers product features, operation, and safety, supporting multiple languages for global users.
Preview Guide TD Delphinus Series: High-Performance Thermal Imaging Monocular
Explore the Guide TD Delphinus Series, a cost-effective handheld thermal imaging monocular for outdoor exploration, law enforcement, and search & rescue. Features high sensitivity, 1280x960 LCOS display, 8-hour battery, and IP66 rating.
Preview Guide Sensmart TD Delphinus Series: Handheld Thermal Imaging Monocular
Explore the Guide Sensmart TD Delphinus Series handheld thermal imaging monocular. Featuring high-resolution displays, long battery life, and rugged IP66 encapsulation, these devices are ideal for outdoor, security, and professional applications. Discover detailed specifications and detection ranges for models TD210, TD410, TD420, and TD430.
Preview Vision Enhancement Imager Quick Start Guide
Quick start guide for the Vision Enhancement Imager, detailing its appearance, functions, and basic operations. Includes setup and usage information.
Preview Guide Sensmart TD Delphinus Series Handheld Thermal Imaging Monocular
Explore the night with the Guide Sensmart TD Delphinus Series, a series of cost-effective handheld thermal imaging monoculars. Featuring clear imaging, comfortable observation, and rugged IP66 encapsulation, these devices are ideal for outdoor enthusiasts, law enforcement, and search and rescue operations. Available in multiple models (TD210, TD410, TD420, TD430) with varying specifications for detection and recognition ranges.