R27 - 2 Zone Programmer
Installation Instructions
For use in normal environments.
CAUTION!
Installation and connection should only be carried out by a qualified person and in accordance with national wiring regulations.
- Before commencing any work on the electrical connections, you must first disconnect the programmer from the mains. None of the 230V connections must be live until the installation has been completed and the housing is closed. Only qualified electricians or authorised service staff are permitted to open the programmer. Disconnect from mains supply in the event of any damage to any buttons.
- There are parts that carry mains voltage behind the cover. The programmer must not be left unsupervised when open. (Prevent non specialists and especially children from gaining access to it.)
- If the programmer is used in a way not specified by the manufacturer, its safety may be impaired.
- Prior to setting the timeswitch, it is necessary to complete all required settings described in this section.
- Never remove this product from the electrical baseplate. Do not use sharp tools to push any button.
This 2 zone programmer is designed to provide ON/OFF control for 2 zones, with the value added application of in-built frost protection.
Important: Keep this document
This programmer can be mounted in the following ways: 1. Directly wall mounted 2. Mounted to a recessed conduit box
Mounting Option 1: Directly wall mounted
Diagram showing a programmer mounted directly to a wall.
Mounting Option 2: Mounted to a recessed conduit box
Diagram showing a programmer mounted to a recessed conduit box.
1. Factory default settings
- Contacts: 230 Volt
- Program: 5/2D
- Backlight: On
- Keypad: Unlocked
- Frost Protection: Off
- Clock type: 24 Hr Clock
- Day-Light Saving: On
2. Specifications & wiring
Specifications:
- Power Supply: 230 Vac
- Ambient Temp: 0~35°C
- Contact Rating: 250 Vac 3A(1A)
- Program Memory backup: 1 year
- Battery: 3Vdc Lithium LIR 2032
- Backlight: Blue
- IP rating: IP20
- Backplate: British System Standard
- Pollution degree 2: Resistance to voltage surge 2000V as per EN 60730
- Automatic Action: Type 1.C
- Software: Class A
Wiring Diagram:
Diagram illustrating the wiring connections for the R27 programmer. It shows connections for mains power (N, L) and outputs for Zone 1 (Z1, Z1) and Zone 2 (Z2, Z2), with terminals labeled 1, 2, 3, 4. The diagram indicates power supply voltage (200-240Vac, 50Hz-60Hz) and contact rating (250Vac~/3(1)A).
3. Master reset
To perform a master reset:
- Lower the cover on the front of the programmer. There are four hinges holding the cover in place.
- Between the 3rd and 4th hinges, there is a circular hole. Insert a ballpoint pen or similar object to master reset the programmer.
After pressing the master reset button, the date and time will need to be reprogrammed.