Features
Sealed IP67, IP68, and IP69K lighting for use with Vision Systems in washdown environments To view or download the latest technical information about this product, including specifications, dimensions, accessories, and wiring, go to www.bannerengineering.com.
· Four high-intensity, visible wavelengths, plus IR and UV · Oil, chemical, and water resistant with IP67, JIS C IP68G, and IP69K per DIN
40050-9 · Available in 340 mm and 640 mm lengths · Highly resistant to vibration and shock · High-power, solid-state LED array; continuous or strobed operation · PNP and NPN strobe operation · Black e-coated aluminum housing

Model Key

Family BL60

Color W
W = Daylight white (5000K) R = Red G = Green B = Blue
I = Infrared UV365 = 365 nm Ultraviolet UV395 = 395 nm Ultraviolet

Length (mm) 340 340 640

Window

Lensing

Control

L14

A

Blank = Clear polycarbonate
D = Diffused polycarbonate
G = Borosilicate glass

Visible and IR Models: L14 = 14-
degree FWHM narrow lenses
UV Models: L30 = 30degree FWHM wide
lenses

A = Adjustable PWM/Strobe and 1 V to 10 V dimming

Sealed S
S = Sealed

Connection
Q
Q = Integral 5-pin M12 male quickdisconnect connector

The following caution applies to white LED models and blue LED models:

CAUTION: Risk Group 2: Possibly hazardous optical radiation emitted from this product.
Do not stare at the operating lamp. May be harmful to the eyes. Risk Group 2 (RG 2) products generally do not pose a realistic optical hazard if aversion responses limit the exposure duration or where lengthy exposures are unrealistic.
- IEC 62471

The following caution applies to ultraviolet models:

CAUTION: Risk Group 2: UV Emitted from this product.
Eye or skin irritation may result from exposure. Use appropriate shielding and eye protection. Risk Group 2 (RG 2) products generally do not pose a realistic optical hazard if aversion responses limit the exposure duration or where lengthy exposures are unrealistic.
- IEC 62471

The following caution applies to infrared models:

Original Instructions May 28, 2024

© Banner Engineering Corp.

p/n: 239886 Rev. A

BL60 Sealed LED Bar Light Instruction Manual

CAUTION: Risk Group 1: IR Emitted from this product.
Use appropriate shielding or eye protection. Risk Group 1 (RG 1) products are safe for most use applications, except for very prolonged exposures where direct ocular exposures may be expected.
- IEC 62471

Wiring
Pinout

2 1

3

4

5

Pin Number Pin 1 Pin 2 Pin 3 Pin 4 Pin 5

Wire Color Brown White Blue Black Gray

1 V to 10 V Analog Dimming and Strobing/PWM Dimming Models
12 V DC to 30 V DC
NPN PWM/Strobe Input: For maximum intensity, leave the white wire floating, or connect to 12 V DC to 30 V DC. Connecting to DC common causes the LEDs to shut off.
DC common
PNP PWM/Strobe Input: For maximum intensity, leave the black wire floating, or connect to DC common. Connecting to 12 V DC to 30 V DC causes the LEDs to shut off.
1 V DC to 10 V DC Analog Dimming

Specifications
Supply Voltage 12 V DC to 30 V DC Use only with a suitable Class 2 power supply (UL) or SELV power supply (CE) See the electrical characteristics on the product label.
Supply Protection Circuitry Protected against reverse polarity and transient voltages
Pulse Width Modulation (PWM)/Strobe Control Maximum Frequency: 30 kHz Minimum On Time: 20 s Input Delay Time: 5 s Input Voltage Threshold:
PNP: > 7 V DC NPN: < 2 V DC
Input Current Maximum: 5 mA
Analog Control Intensity Adjustment Range: 10% to 100% Input Voltage Range: 1 V DC to 10 V DC Input Current Maximum: 5 mA
Construction Housing: Black e-coated aluminum housing Window: Clear or diffuse polycarbonate window, or clear borosilicate glass window
Mounting (6) M6×1 threaded holes in back; multiple bracket options available
Connections Integral 5-pin M12 male quick-disconnect connector, accessory cordset required
LED Lifetime Lumen Maintenance: L70 When operating within specifications, the output decreases less than 30% after the following time periods:
Daylight White: 90,000 hours Red: 70,000 hours Green: 70,000 hours Blue: 50,000 hours Yellow: 60,000 hours UV: 35,000 hours

Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave)
Operating Conditions ­40 °C to +50 °C (­40 °F to +122 °F)
Storage Temperature ­40 °C to +70 °C (­40 °F to +158 °F)
Environmental Rating IP67, JIS C IP68G, IP69K per DIN 40050-9
Required Overcurrent Protection

WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.

Overcurrent protection is required to be provided by end product application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.

Supply Wiring (AWG)
20
22
24

Required Overcurrent Protection (A)
5.0 3.0 1.0

Supply Wiring (AWG)
26
28
30

Required Overcurrent Protection (A)
1.0 0.8 0.5

page 2

© Banner Engineering Corp. All rights reserved.

May 28, 2024

BL60 Sealed LED Bar Light Instruction Manual

Certification
Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM

Turck Banner LTD Blenheim House Blenheim Court Wickford, Essex SS11 8YT GREAT BRITAIN

Supply Current
Light Length (mm) 340
640

Color
White Red Green Blue Infrared 365 nm UV 395 nm UV White Red Green Blue Infrared 365 nm UV 395 nm UV

Max. Current Draw (A) at 12 V DC
1.6 1.6 1.6 1.6 1.6 1.6 1.6 3.0 3.0 3.0 3.0 3.0 3.0 3.0

12 V DC 1.290 0.965 1.100 1.175 0.680 1.525 1.355 2.475 1.845 2.005 2.135 1.270 2.815 2.555

Typical Current Draw (A) 24 V DC 0.600 0.460 0.525 0.550 0.340 0.695 0.625 1.130 0.880 0.955 1.005 0.635 1.280 1.180

30 V DC 0.485 0.375 0.425 0.445 0.280 0.560 0.500 0.910 0.720 0.780 0.820 0.525 1.040 0.955

FCC Part 15 Class B for Unintentional Radiators
(Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.
(Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

May 28, 2024

© Banner Engineering Corp. All rights reserved.

page 3

BL60 Sealed LED Bar Light Instruction Manual
Dimensions
M12 x 1

340 mm Models

M12 x 1

6X M6 x 1
640 mm Models

6X M6 x 1

page 4

© Banner Engineering Corp. All rights reserved.

May 28, 2024

BL60 Sealed LED Bar Light Instruction Manual

Optical Data

Light Characteristic: Clear and Diffuse Window Values shown are typical at 25 °C.

Lighted Length (mm)
340 640

Daylight White (5000K)
1375
2600

Lumens

Green (525nm) Red (625nm)

1025 1950

650 1275

mWatts

Blue (475nm) UV365 (365nm) UV395 (395nm)

300

2500

2750

575

4600

5000

IR (850nm) 2450 4550

Photometric Data
Optical data shown below is for daylight white and UV 365nm models only. To get lux/irradiance and candela/radiant intensity values for models with other colors, multiply the values shown on the charts by the following factors:

Green Red Blue UV395 IR

Color

0.750 0.473 0.218 1.100 1.782

Multiplier

CD (candela)

340 mm White Clear Window
BL60 White Clear (340)

Polar Candela Distribution

Isolux Pattern

1

0 m

1

6400

180° 170°160°

1

150°

5333

140°

4267

130°

3200

120°

2133 1067

100°

0 1067 2133 3200 4267 5333 6400

90°
80°
70° 60° 50° 40° 30° 0° 10° 20°

0 m

90° Horizontal

1 Mount height of 1 meter (1 m)

5000 lux 4000 lux 3000 lux

2000 lux 1000 lux 500 lux

250 lux 100 lux

0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m

Illuminance at a Distance

Center Beam (lux) 78820 lux 36450 lux 20710 lux 13490 lux 9460 lux 6349 lux

0.06 m 0.08 m 0.12 m 0.15 m 0.18 m 0.22 m 0.24 m 0.30 m 0.30 m 0.37 m 0.36 m 0.45 m
Horiz.

Horizontal Spread: 25.3°

May 28, 2024

© Banner Engineering Corp. All rights reserved.

page 5

BL60 Sealed LED Bar Light Instruction Manual

CD (candela)

640 mm White Clear Window

BL60 White Clear (640)

Polar Candela Distribution

Isolux Pattern

8600

1

180° 170°160°

1

150°

0 m

1

7167

140°

5733

130°

4300

120°

2867 1433

100°

0 1433 2867 4300 5733 7167 8600

90°
80° 70° 60° 50° 40° 30° 0° 10° 20°
90° Horizontal

0 m
1 Mount height of 1 meter (1 m)

7500 lux 6000 lux 4500 lux

3000 lux 1500 lux 750 lux

250 lux 100 lux

0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m

Illuminance at a Distance

Center Beam (lux) 72850 lux 34100 lux 21760 lux 15470 lux
8519 lux

0.07 m 0.13 m 0.22 m 0.20 m 0.33 m 0.27 m 0.44 m 0.33 m 0.55 m 0.40 m 0.66 m
Horiz.

Horizontal Spread: 36.5°

340 mm White Diffuse Window

BL60 White Diffuse (340)

Polar Candela Distribution

Isolux Pattern

2800

1

180° 170°160°

1

150°

0 m

1

2333

140°

1867

130°

1400

120°

933

467

100°

0 467 933 1400 1867 2333 2800

90°
80°
70° 60° 50° 40° 30° 0° 10° 20°

0 m

90° Horizontal

1 Mount height of 1 meter (1 m)

2500 lux 2000 lux 1500 lux

1000 lux 500 lux 250 lux

125 lux 50 lux

0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m

Illuminance at a Distance

Center Beam (lux) 42960 lux 18650 lux 9732 lux 6023 lux 4015 lux 2890 lux

0.09 m 0.12 m 0.17 m 0.24 m 0.26 m 0.35 m 0.35 m 0.47 m 0.44 m 0.59 m 0.52 m 0.71 m
Horiz.

Horizontal Spread: 39.0°

CD (candela)

page 6

© Banner Engineering Corp. All rights reserved.

May 28, 2024

CD (candela)

BL60 Sealed LED Bar Light Instruction Manual

640 mm White Diffuse Window
BL60 White Diffuse (640)

Polar Candela Distribution

Isolux Pattern

3900

1

180° 170°160°

1

150°

0 m

1

3250

140°

2600

130°

1950

120°

1300 650

100°

0 650 1300 1950 2600 3250 3900

90°
80° 70° 60° 50° 40° 30° 0° 10° 20°
90° Horizontal

0 m
1 Mount height of 1 meter (1 m)

3750 lux 3000 lux 2225 lux

1500 lux 750 lux 375 lux

125 lux 50 lux

0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m

Illuminance at a Distance

Center Beam (lux) 38200 lux 18040 lux
8305 lux 5519 lux 3950 lux

0.12 m 0.23 m 0.25 m 0.34 m 0.37 m 0.46 m 0.50 m 0.57 m 0.62 m 0.69 m 0.74 m
Horiz.

Horizontal Spread: 40.8°

340 mm UV365
BL60 UV365 Clear (340)

Polar Radient Intensity Distribution

2600 2167 1733 1300
867 433
0 433 867 1300 1733 2167 2600

180° 170°160° 150° 140° 130° 120°
100° 90° 80° 70° 60° 50° 40° 30° 0° 10° 20°
90° Horizontal

Iso-irradiance Pattern

1

0 m

1

0 m

1 Mount height of 1 meter (1 m)

1
0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m

2500 mW/m2 2000 mW/m2 1500 mW/m2

1000 mW/m2 500 mW/m2 250 mW/m2

125 mW/m2 50 mW/m2

Irradiance at a Distance

Center Beam (lux) 25900 mW/m2 12540 mW/m2 7430 mW/m2 4700 mW/m2 3500 mW/m2 2500 mW/m2

0.10 m 0.10 m 0.21 m 0.20 m 0.31 m 0.31 m 0.42 m 0.41 m 0.52 m 0.51 m 0.63 m 0.62 m

Horiz.
Horizontal Spread: 34.2°

mW/sr

May 28, 2024

© Banner Engineering Corp. All rights reserved.

page 7

BL60 Sealed LED Bar Light Instruction Manual

mW/sr

640 mm UV365
BL60 UV365 Clear (640)

Polar Radient Intensity Distribution

2600 2167 1733 1300
867 433
0 433 867 1300 1733 2167 2600

180° 170°160° 150° 140° 130° 120°
100° 90° 80° 70° 60° 50° 40° 30° 0° 10° 20°
90° Horizontal

Iso-irradiance Pattern

1

0 m

1

0 m

1 Mount height of 1 meter (1 m)

1
0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m

2500 mW/m2 2000 mW/m2 1500 mW/m2

1000 mW/m2 500 mW/m2 250 mW/m2

125 mW/m2 50 mW/m2

Irradiance at a Distance

Center Beam (lux) 23200 mW/m2 12200 mW/m2 7040 mW/m2 4830 mW/m2 3760 mW/m2 2950 mW/m2

0.17 m 0.22 m 0.33 m 0.33 m 0.49 m 0.44 m 0.66 m 0.54 m 0.82 m 0.65 m 0.99 m

Horiz.
Horizontal Spread: 52.5°

Accessories
Cordsets
Model MQDC1-501.5 MQDC1-503 MQDC1-506 MQDC1-515 MQDC1-530 MQDC1-560 MQDC1-5100 MQDC1-506RA MQDC1-515RA MQDC1-530RA
MQDC1-560RA

Length 0.5 m (1.5 ft) 0.9 m (2.9 ft) 2 m (6.5 ft) 5 m (16.4 ft) 9 m (29.5 ft) 18 m (59 ft) 31 m (101.7 ft) 2 m (6.5 ft) 5 m (16.4 ft) 9 m (29.5 ft)
19 m (62.3 ft)

5-Pin Threaded M12 Cordsets--Single Ended

Style

Dimensions

Straight

44 Typ.
M12 x 1 ø 14.5

Right-Angle

32 Typ. [1.26"]
30 Typ. [1.18"]
M12 x 1 ø 14.5 [0.57"]

Pinout (Female)

2 1

3

4

5

1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray

page 8

© Banner Engineering Corp. All rights reserved.

May 28, 2024

Model MQDC-WDSS-0506 MQDC-WDSS-0515
MQDC-WDSS-0530
Brackets

BL60 Sealed LED Bar Light Instruction Manual

5-Pin Threaded M12 Stainless Steel Washdown Cordsets--Single Ended

Length

Style

Dimensions

Pinout (Female)

2 m (6.56 ft) 5 m (16.4 ft)
9 m (29.5 ft)

Straight

Ø15.5 mm

43.5 mm

2 1

3

4

5

Ø4.8 mm

1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray

LMBWLC60F
· Set of two flat brackets · 300 series stainless steel · Includes M6 flathead screws for mounting to light · Clearance for M6 or 1/4-20 mounting hardware

LMBWLC60MAG · Magnetic mounting kit (set of two) · Two-inch magnets · Mounting hardware included
LMBWLC60B340 · Plate for sealing the cavity on the back of the 340 mm models · 300 series stainless steel · Includes hardware for mounting to the light
ACC-WLC60-340-GSK-N-1 · Black nitrile gasket · Thickness: 1.5 mm
LMBWLC60RA · Set of two right-angle brackets · 300 series stainless steel · Includes M6 button head screws for mounting to light · Clearance for M6 or 1/4-20 mounting hardware

393 12

62

10 x Ø7

340 61
1.5 6 X Ø7

May 28, 2024

© Banner Engineering Corp. All rights reserved.

page 9

BL60 Sealed LED Bar Light Instruction Manual

LMBWLC60RAS
· Pair of two swivel mount, right-angle brackets · 300 series stainless steel · Includes hardware for mounting to light

ACC-WLC60-340-GSK-FDA-1
· Blue FDA-approved silicone gasket · Thickness: 1.6 mm

340 61
1.6 6 X Ø7

Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.

page 10

© Banner Engineering Corp. All rights reserved.

May 28, 2024



References