IECEx Certificate of Conformity

International Electrotechnical Commission (IEC) Certification System for Explosive Atmospheres

Certificate Information

  • Certificate No.: IECEX BVS 20.0058X
  • Status: Current
  • Issue No: 0
  • Date of Issue: 2020-09-01
  • Certificate History: Available via IECEx website

Applicant and Equipment Details

Applicant:

SIEMENS AG
Vogelweiherstraße 1-15
Nürnberg 90441
Germany

Equipment:

Three-phase induction motors type 1MB1*6*-1C*******-Z***

Optional Accessory:

Not specified in main text, refer to Annex.

Protection and Marking

Type of Protection:

Flameproof Enclosure "d", Increased Safety "e", Protection by Enclosure "t"

Marking:

  • Ex db eb IIA/IIB T* Gb
  • or Ex db eb IIA/IIB T* Gb Ex tb IIIA/IIIB/IIIC T***°C Db
  • or Ex db eb IIA/IIB T* Gb Ex tc IIIA/IIIB/IIIC T***°C Dc

Associated Types:

  • Type 1MB1*6*-1C*******-Z
  • Type 1MB1*6*-1C*******-ZB32
  • Type 1MB1*6*-1C*******-ZB30

Approval and Issuing Body

Approved for issue on behalf of the IECEx Certification Body:

Dr Franz Eickhoff
Lead Auditor and officially recognised expert

Certificate Issued By:

DEKRA Testing and Certification GmbH
Certification Body
Dinnendahlstrasse 9
44809 Bochum
Germany

Standards Compliance

The equipment was assessed and found to comply with the following IEC standards:

  • IEC 60079-0:2017, Edition 7.0: Explosive atmospheres - Part 0: Equipment - General requirements
  • IEC 60079-1:2014-06, Edition 7.0: Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
  • IEC 60079-31:2013, Edition 2: Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
  • IEC 60079-7:2017, Edition 5.1: Explosive atmospheres - Part 7: Equipment protection by increased safety "e"

Note: This Certificate does not indicate compliance with safety and performance requirements other than those expressly included in the Standards listed above.

Test and Assessment Reports

  • Test Report: DE/BVS/EXTR20.0054/00
  • Quality Assessment Report: DE/BVS/QAR09.0009/11

Equipment Description and Specific Conditions of Use

Equipment Description:

The equipment consists of rotating electrical machines (three-phase induction motors) designed in type of protection Flameproof Enclosure "db". They are equipped with separately certified terminal boxes in type of protection Increased Safety "eb" for use in hazardous gas atmospheres. For hazardous dust atmospheres, the machines can be in type of protection Protection by Enclosure "tb" for zone 21 or "tc" for zone 22, with terminal boxes compliant to "tb" or "tc" levels.

The machine housing, end shield, and bearing caps are made of cast iron. The rotor is made of steel. Non-metallic gamma rings or radial shaft sealings are used. Cooling is achieved by an external fan made of steel, aluminum, brass, or plastic, driven by the machine itself.

Optional features include space heaters inside the stator housing (operation allowed only when the machine is not running) and certified encoders.

Specific Conditions of Use (SCU):

  • Flameproof joint dimensions (lengths and gaps) may differ from standard table values; contact manufacturer for details.
  • Screws must have a yield strength of 450 N/mm² or better.
  • For non-self-cooled machines, forced cooling must be ensured, or the machine must be monitored by installed temperature sensors with a suitable trigger unit.
  • The machine must be operated with a voltage source converter with pulse width modulation (PWM) regarding electrical parameters.
  • Ensure no inadmissible overvoltage from converter supply occurs at motor terminals before setup.
  • Maximum permissible peak voltages: 1500Vpk (standard), 2200Vpk (optional).
  • Motor variants with temperatures above 70°C at cable glands and 80°C at wire branching are marked with an additional label.

Electrical Parameters

1.1 Electrical Parameters (Rotating Electrical Machine)

ParameterValue
Maximum rated voltageup to 690 V
Maximum rated currentup to 57 A
Maximum rated powerup to 17 kW
Maximum rated torqueup to 119 Nm
Maximum rated frequencyup to 100 Hz
Maximum polesup to 12
Maximum rotational speedup to 5400 min⁻¹
Duty typeS1-S9

Note: For converter-fed machines, the fundamental wave voltage at motor terminals must not be decreased by 10%, considering minimum converter input voltage and supply line/filter voltage drop.

1.2 Electrical Parameters (Voltage-Source Converter)

ParameterValue
Used input voltageRated voltage of motor V
Minimum switching frequency2 kHz
Current limiting value1.5 x IN
Maximum overload time60 S
Output frequency5 up to 100 Hz

Note: Overload time and operation below minimum output frequency are related to a 10-minute period.

1.3 Electrical Parameters (Monitoring Circuits)

Circuit TypeUmaxImax
PTC thermistors30 VDC0.5 A
Resistance thermometer Pt1000.5 VDC1 mA
Resistance thermometer Pt10001 V0.5 mA

Thermal Parameters

2.1 General

  • Temperature class / Surface temperature: T6 to T3 / up to T200 °C. Specific values are indicated on the rating plate and data sheet.

2.2 Thermal Ratings (Flameproof Enclosure)

  • Ambient temperature range: -20 °C ≤ Tamb ≤ 40 °C (standard); -40 °C ≤ Tamb ≤ 60 °C (optional)

Annex Reference

Further details regarding subject and type, description, parameters, and specific conditions of use are provided in the Annex document: BVS_20_0058X_Siemens_Annex.pdf

Disclaimer

This certificate and schedule may only be reproduced in full. It is not transferable and remains the property of the issuing body. Status and authenticity can be verified via www.iecex.com or the provided QR Code.

PDF preview unavailable. Download the PDF instead.

IECEx BVS20.0058X Canon iR-ADV C5235 PDF Adobe PSL 1.2e for Canon

Related Documents

Preview Siemens SIMATIC IPC227E (6ES7647-8BB21-7EA3) Datasheet - Industrial Nanobox PC
Detailed technical specifications for the Siemens SIMATIC IPC227E Nanobox PC (6ES7647-8BB21-7EA3), including processor, memory, storage, interfaces, EMC compliance, and operating conditions.
Preview Arc Faults in Medium-Voltage and Low-Voltage Switchgear: Technical Series Edition 7.1
A comprehensive guide on arc faults in medium-voltage and low-voltage switchgear, detailing causes, effects, pressure loads, protection strategies (passive and active), testing of personal protective equipment (PPE), and calculation methods for arc energy and incident energy. Includes safety standards and practical considerations for electrical installations.
Preview Siemens S7-1200 System Manual Update 01/2015: Corrections and New Information
This document provides crucial updates and corrections for the Siemens S7-1200 Programmable Controller System Manual, edition 01/2015, covering topics like Profibus communication, error conditions, wiring, firmware updates, and CE approvals.
Preview Siemens SIMOTICS XP 1MB1.33 Eagle Line Low-Voltage Motors Operating Instructions
Detailed operating instructions for Siemens SIMOTICS XP 1MB1.33 Eagle Line low-voltage motors. Covers safe handling, assembly, installation, commissioning, operation, maintenance, and disposal for industrial applications.
Preview Siemens Solkor 7SR18 Differential Protection Relay Datasheet
Datasheet for the Siemens Solkor 7SR18 differential protection relay, model 7SR1811-1MC87-0CA0. Details technical specifications, protection functions, communication interfaces, and mechanical dimensions.
Preview Dimensionamento de Condutores de Proteção em Subestações - Série Técnica Siemens 20
Publicação técnica da Siemens detalhando o dimensionamento de condutores de proteção em subestações. Abrange arranjos de aterramento, análise de curto-circuito e conformidade com normas internacionais como IEC 60364-5-54, oferecendo orientação prática para engenheiros elétricos e planejadores.
Preview Siemens SENTRON 3VA Molded Case Circuit Breakers Manual
Comprehensive manual for Siemens SENTRON 3VA Molded Case Circuit Breakers with IEC-certificate, covering product information, applications, technical details, accessories, and service.
Preview Siemens DXR2/DXP2 Compact Room Automation Stations EU Declaration of Conformity
Official EU Declaration of Conformity for Siemens DXR2xxx.xxx and DXP2xxx.xxx Compact Room Automation Stations, detailing compliance with EMC and RoHS directives and relevant harmonized standards.