Namron Glassovn Panel Heater

600W / 800W / 1000W

Instruction Manual

Product Overview

The Glassovn Panel heater offers an elegant design suitable for most environments. It features an electronic thermostat with a program setting and a bright LCD display at the top for easy operation. The heater is delivered with a wall bracket; feet for floor standing can be purchased separately. It is intended for indoor use only.

Specifications:

  • Effect: 600W/800W/1000W
  • Operating Voltage: 220-240V~ 50-60Hz
  • IP Rating: IP24
  • Includes a 1.6m cable and plug.

Assembly Instructions

Mounting the Heater:

  1. Drill holes in the wall. Refer to diagram (a) for the distance between holes.
  2. Attach the mounting clips securely to the wall.
  3. Push the heater into the clips and use the provided screws to tighten the clips.

Mounting Hole Distances (a):

Model Distance (a)
600W 13cm
800W 26cm
1000W 32cm

Note: Minimum clearances required: 30cm above, 15cm to the sides, 19cm in front, 5cm below, 20cm behind.

Operation

Control Panel Description:

  • [Power Switch]: Turns the heater on/off.
  • [LCD Display]: Shows room temperature, day, and program status.
  • [Timer Button]: Activates timer functions.
  • [Increase Button +]: Increases temperature or adjusts settings.
  • [Moon Button]: Selects default temperature for unprogrammed hours.
  • [On/Off Button]: Puts the heater in standby or starts heating.
  • [Program Button PROG]: Used for setting the weekly program and clock.
  • [Decrease Button -]: Decreases temperature or adjusts settings.

Using the Heater Without Weekly Program:

  1. Turn on the [Power Switch]. The display shows room temperature and day (FIG. 1).
  2. Press [On/Off Button] for standby mode. Press [On/Off Button] again to start heating (heating symbol [SSS] appears).
  3. Press [+] or [-] to set the desired temperature (5°C - 35°C). The display reverts to room temperature after a few seconds. Factory default is 20°C.

Using the Heater With Weekly Program:

  1. Turn on the [Power Switch]. Display shows room temperature and day (FIG. 1).
  2. Press [On/Off Button] for standby. Press [On/Off Button] again to start heating (heating symbol [SSS] appears).
  3. Press [Program Button PROG] to set day/clock (FIG. 2). The day symbol blinks. Use [+] or [-] to set the day (1=Monday, 7=Sunday). Press [PROG] again, the time blinks. Use [+] or [-] to set the current time. Press [PROG] to finish clock setting. Note: If no key is pressed for 10 seconds, settings revert to factory default (00:00).
  4. Press and hold [Program Button PROG] for 3 seconds in working mode to view weekly program settings (FIG. 3).
  5. Press [+] or [-] to select the day you want to program. The day symbol blinks.
  6. Press [Program Button PROG] again. The hour symbol blinks. Use [+] or [-] to set the desired time range (e.g., 07:16 means 7 AM to 4 PM). Time slots are indicated by bars on the display (FIG. 4).
  7. Press [Program Button PROG] again. The temperature blinks. Use [+] or [-] to set the desired temperature for the programmed period (e.g., 25:17 means 25°C during programmed hours, 17°C outside programmed hours).
  8. Press [Program Button PROG] and the day symbol blinks to continue programming other days. Press the [Moon Button] to select default temperature for unprogrammed hours (default is 15°C).
  9. Press the [Timer Button] after setting the program. The heater starts the weekly program mode (FIG. 4), and the clock symbol appears. Note: Ensure clock is set correctly before programming.

Special Functions & Information

  • Window Open Remind: If the room temperature drops more than 5°C within 10 minutes, the window symbol on the LCD display blinks rapidly. Press any key to stop it. The heater resumes previous program. If blinking continues for over 10 minutes, the heater automatically enters Anti-frost mode (10°C) until a key is pressed.
  • Power Cut Remind: The display blinks to indicate a power outage. Press any key to stop blinking. The heater has a 24-hour memory function; if power returns within 24 hours, it resumes the previous program and time setting.
  • Child Lock: Lock the thermostat by holding down both [+] and [-] buttons for 3 seconds. Repeat to unlock.
  • Reset to Default: Press and hold [On/Off Button] for 5 seconds to revert to default settings.
  • First Time Use: For initial use, set the heater to maximum temperature for 30 minutes to burn off any residue. Some smell may occur during this process.

Dimensions

Model Width Height
600W 480mm 360mm
800W 580mm 360mm
1000W 680mm 360mm

Corresponding Products & Mounting of Feet

Feet for Panel Heater: Electrical No. 5401373

Mounting of Feet: For floor standing use, attach the feet to the base of the heater using the two self-tapping screws provided before operating the heater.

Safety Information

  • DO NOT COVER: Do not cover the heater surface, as it can become very hot. Place the heater at a safe distance from flammable materials.
  • Disconnect power during maintenance.
  • If using an extension cord, it must be as short as possible and fully extended while the heater is in use.

Technical Specifications

Model identifier(s): 5401387, 5401388, 5401389

Item Symbol Value Unit Item Description Unit
Heat output Pnom 0.5-0.6 kW Nominal heat output: manual heat charge control, with integrated thermostat No
Pmin 0.50 kW Minimum heat output (indicative): manual heat charge control with room and/or outdoor temperature feedback No
Pmax,c 0.60 kW Maximum continuous heat output: electronic heat charge control with room and/or outdoor temperature feedback No
Auxiliary electricity consumption elmax N/A kW At nominal heat output: Type of heat output/room temperature control (select one)
elmin N/A kW At minimum heat output: single stage heat output and no room temperature control No
elSB 0.00016 kW In standby mode: Two or more manual stages, no room temperature control No
with mechanic thermostat room temperature control No
with electronic room temperature control No
electronic room temperature control plus day timer No
electronic room temperature control plus week timer Yes
Other control options (multiple selections possible) room temperature control, with presence detection No
room temperature control, with open window detection Yes
with distance control option No
with adaptive start control No
with working time limitation No
with black bulb sensor No

Model identifier(s): 5401388

Item Symbol Value Unit Item Description Unit
Heat output Pnom 0.67-0.8 kW Nominal heat output: manual heat charge control, with integrated thermostat No
Pmin 0.67 kW Minimum heat output (indicative): manual heat charge control with room and/or outdoor temperature feedback No
Pmax,c 0.80 kW Maximum continuous heat output: electronic heat charge control with room and/or outdoor temperature feedback No
Auxiliary electricity consumption elmax N/A kW At nominal heat output: Type of heat output/room temperature control (select one)
elmin N/A kW At minimum heat output: single stage heat output and no room temperature control No
elSB 0.00016 kW In standby mode: Two or more manual stages, no room temperature control No
with mechanic thermostat room temperature control No
with electronic room temperature control No
electronic room temperature control plus day timer No
electronic room temperature control plus week timer Yes
Other control options (multiple selections possible) room temperature control, with presence detection No
room temperature control, with open window detection Yes
with distance control option No
with adaptive start control No
with working time limitation No
with black bulb sensor No

Model identifier(s): 5401389

Item Symbol Value Unit Item Description Unit
Heat output Pnom 0.85-1.0 kW Nominal heat output: manual heat charge control, with integrated thermostat No
Pmin 0.85 kW Minimum heat output (indicative): manual heat charge control with room and/or outdoor temperature feedback No
Pmax,c 1.00 kW Maximum continuous heat output: electronic heat charge control with room and/or outdoor temperature feedback No
Auxiliary electricity consumption elmax N/A kW At nominal heat output: Type of heat output/room temperature control (select one)
elmin N/A kW At minimum heat output: single stage heat output and no room temperature control No
elSB 0.00016 kW In standby mode: Two or more manual stages, no room temperature control No
with mechanic thermostat room temperature control No
with electronic room temperature control No
electronic room temperature control plus day timer No
electronic room temperature control plus week timer Yes
Other control options (multiple selections possible) room temperature control, with presence detection No
room temperature control, with open window detection Yes
with distance control option No
with adaptive start control No
with working time limitation No
with black bulb sensor No
Models: 600W Glassovn Panel, 600W, Glassovn Panel, Panel

File Info : application/pdf, 8 Pages, 1.18MB

PDF preview unavailable. Download the PDF instead.

5401371-Brukerveiledning-5 Adobe PDF library 10.01 Adobe Illustrator(R) 24.0

Related Documents

Preview Namron 2000W Wall-mounted Terrace Heater Instruction Manual
Official instruction manual for the Namron 2000W wall-mounted terrace heater, covering installation, operation, and safety guidelines.
Preview Namron WiFi Patio Heater 2000W: Installation and Operation Manual
Comprehensive instruction manual for the Namron WiFi 2000W patio heater, covering installation, safety, remote control operation, and WiFi connectivity via the Tuya Smart app.
Preview Namron Low Glare Patio Heater with Remote Control - Instruction Manual
Comprehensive instruction manual for the Namron Low Glare Patio Heater, detailing installation, safety, operation, and remote control functions. Features infrared heating technology for energy efficiency.
Preview Namron LED Dimmer 600W Instruction Manual
Instruction manual for the Namron LED Dimmer 600W, covering installation, wiring, specifications, and operation for push/rotary dimming.
Preview Namron Dimmable LED Driver 700-1000mA 30V-40V IP20 Instruction Manual
Instruction manual for the Namron dimmable LED driver, model 700-1000mA, with specifications for input/output voltage, power, dimming, IP rating, and wiring instructions. Includes dimensions and output current settings.
Preview Namron Z-Wave Thermostat: Installation and Operation Manual
Explore the Namron Z-Wave Thermostat's features, installation guide, and operational modes. This manual covers Z-Wave connectivity, sensor integration, programming, and energy-saving functions for smart home heating.
Preview Namron Alfa Eco Downlight 8W 8-Pack: Instruction Manual & Specifications
Comprehensive instruction manual and technical specifications for the Namron Alfa Eco Downlight 8W 8-pack. Learn about installation, dimensions, and features.
Preview Namron UFO High Bay LED Instruction Manual and Specifications
Comprehensive instruction manual and technical specifications for Namron UFO High Bay LED lights (150W and 240W models), including mounting, wiring, and energy efficiency details.