Namron Glassovn Panel Heater
600W / 800W / 1000W
Instruction Manual
Product Overview
The Glassovn Panel heater offers an elegant design suitable for most environments. It features an electronic thermostat with a program setting and a bright LCD display at the top for easy operation. The heater is delivered with a wall bracket; feet for floor standing can be purchased separately. It is intended for indoor use only.
Specifications:
- Effect: 600W/800W/1000W
- Operating Voltage: 220-240V~ 50-60Hz
- IP Rating: IP24
- Includes a 1.6m cable and plug.
Assembly Instructions
Mounting the Heater:
- Drill holes in the wall. Refer to diagram (a) for the distance between holes.
- Attach the mounting clips securely to the wall.
- Push the heater into the clips and use the provided screws to tighten the clips.
Mounting Hole Distances (a):
Model | Distance (a) |
---|---|
600W | 13cm |
800W | 26cm |
1000W | 32cm |
Note: Minimum clearances required: 30cm above, 15cm to the sides, 19cm in front, 5cm below, 20cm behind.
Operation
Control Panel Description:
- [Power Switch]: Turns the heater on/off.
- [LCD Display]: Shows room temperature, day, and program status.
- [Timer Button]: Activates timer functions.
- [Increase Button +]: Increases temperature or adjusts settings.
- [Moon Button]: Selects default temperature for unprogrammed hours.
- [On/Off Button]: Puts the heater in standby or starts heating.
- [Program Button PROG]: Used for setting the weekly program and clock.
- [Decrease Button -]: Decreases temperature or adjusts settings.
Using the Heater Without Weekly Program:
- Turn on the [Power Switch]. The display shows room temperature and day (FIG. 1).
- Press [On/Off Button] for standby mode. Press [On/Off Button] again to start heating (heating symbol [SSS] appears).
- Press [+] or [-] to set the desired temperature (5°C - 35°C). The display reverts to room temperature after a few seconds. Factory default is 20°C.
Using the Heater With Weekly Program:
- Turn on the [Power Switch]. Display shows room temperature and day (FIG. 1).
- Press [On/Off Button] for standby. Press [On/Off Button] again to start heating (heating symbol [SSS] appears).
- Press [Program Button PROG] to set day/clock (FIG. 2). The day symbol blinks. Use [+] or [-] to set the day (1=Monday, 7=Sunday). Press [PROG] again, the time blinks. Use [+] or [-] to set the current time. Press [PROG] to finish clock setting. Note: If no key is pressed for 10 seconds, settings revert to factory default (00:00).
- Press and hold [Program Button PROG] for 3 seconds in working mode to view weekly program settings (FIG. 3).
- Press [+] or [-] to select the day you want to program. The day symbol blinks.
- Press [Program Button PROG] again. The hour symbol blinks. Use [+] or [-] to set the desired time range (e.g., 07:16 means 7 AM to 4 PM). Time slots are indicated by bars on the display (FIG. 4).
- Press [Program Button PROG] again. The temperature blinks. Use [+] or [-] to set the desired temperature for the programmed period (e.g., 25:17 means 25°C during programmed hours, 17°C outside programmed hours).
- Press [Program Button PROG] and the day symbol blinks to continue programming other days. Press the [Moon Button] to select default temperature for unprogrammed hours (default is 15°C).
- Press the [Timer Button] after setting the program. The heater starts the weekly program mode (FIG. 4), and the clock symbol appears. Note: Ensure clock is set correctly before programming.
Special Functions & Information
- Window Open Remind: If the room temperature drops more than 5°C within 10 minutes, the window symbol on the LCD display blinks rapidly. Press any key to stop it. The heater resumes previous program. If blinking continues for over 10 minutes, the heater automatically enters Anti-frost mode (10°C) until a key is pressed.
- Power Cut Remind: The display blinks to indicate a power outage. Press any key to stop blinking. The heater has a 24-hour memory function; if power returns within 24 hours, it resumes the previous program and time setting.
- Child Lock: Lock the thermostat by holding down both [+] and [-] buttons for 3 seconds. Repeat to unlock.
- Reset to Default: Press and hold [On/Off Button] for 5 seconds to revert to default settings.
- First Time Use: For initial use, set the heater to maximum temperature for 30 minutes to burn off any residue. Some smell may occur during this process.
Dimensions
Model | Width | Height |
---|---|---|
600W | 480mm | 360mm |
800W | 580mm | 360mm |
1000W | 680mm | 360mm |
Corresponding Products & Mounting of Feet
Feet for Panel Heater: Electrical No. 5401373
Mounting of Feet: For floor standing use, attach the feet to the base of the heater using the two self-tapping screws provided before operating the heater.
Safety Information
- DO NOT COVER: Do not cover the heater surface, as it can become very hot. Place the heater at a safe distance from flammable materials.
- Disconnect power during maintenance.
- If using an extension cord, it must be as short as possible and fully extended while the heater is in use.
Technical Specifications
Model identifier(s): 5401387, 5401388, 5401389
Item | Symbol | Value | Unit | Item Description | Unit |
---|---|---|---|---|---|
Heat output | Pnom | 0.5-0.6 | kW | Nominal heat output: manual heat charge control, with integrated thermostat | No |
Pmin | 0.50 | kW | Minimum heat output (indicative): manual heat charge control with room and/or outdoor temperature feedback | No | |
Pmax,c | 0.60 | kW | Maximum continuous heat output: electronic heat charge control with room and/or outdoor temperature feedback | No | |
Auxiliary electricity consumption | elmax | N/A | kW | At nominal heat output: Type of heat output/room temperature control (select one) | |
elmin | N/A | kW | At minimum heat output: single stage heat output and no room temperature control | No | |
elSB | 0.00016 | kW | In standby mode: Two or more manual stages, no room temperature control | No | |
with mechanic thermostat room temperature control | No | ||||
with electronic room temperature control | No | ||||
electronic room temperature control plus day timer | No | ||||
electronic room temperature control plus week timer | Yes | ||||
Other control options (multiple selections possible) | room temperature control, with presence detection | No | |||
room temperature control, with open window detection | Yes | ||||
with distance control option | No | ||||
with adaptive start control | No | ||||
with working time limitation | No | ||||
with black bulb sensor | No |
Model identifier(s): 5401388
Item | Symbol | Value | Unit | Item Description | Unit |
---|---|---|---|---|---|
Heat output | Pnom | 0.67-0.8 | kW | Nominal heat output: manual heat charge control, with integrated thermostat | No |
Pmin | 0.67 | kW | Minimum heat output (indicative): manual heat charge control with room and/or outdoor temperature feedback | No | |
Pmax,c | 0.80 | kW | Maximum continuous heat output: electronic heat charge control with room and/or outdoor temperature feedback | No | |
Auxiliary electricity consumption | elmax | N/A | kW | At nominal heat output: Type of heat output/room temperature control (select one) | |
elmin | N/A | kW | At minimum heat output: single stage heat output and no room temperature control | No | |
elSB | 0.00016 | kW | In standby mode: Two or more manual stages, no room temperature control | No | |
with mechanic thermostat room temperature control | No | ||||
with electronic room temperature control | No | ||||
electronic room temperature control plus day timer | No | ||||
electronic room temperature control plus week timer | Yes | ||||
Other control options (multiple selections possible) | room temperature control, with presence detection | No | |||
room temperature control, with open window detection | Yes | ||||
with distance control option | No | ||||
with adaptive start control | No | ||||
with working time limitation | No | ||||
with black bulb sensor | No |
Model identifier(s): 5401389
Item | Symbol | Value | Unit | Item Description | Unit |
---|---|---|---|---|---|
Heat output | Pnom | 0.85-1.0 | kW | Nominal heat output: manual heat charge control, with integrated thermostat | No |
Pmin | 0.85 | kW | Minimum heat output (indicative): manual heat charge control with room and/or outdoor temperature feedback | No | |
Pmax,c | 1.00 | kW | Maximum continuous heat output: electronic heat charge control with room and/or outdoor temperature feedback | No | |
Auxiliary electricity consumption | elmax | N/A | kW | At nominal heat output: Type of heat output/room temperature control (select one) | |
elmin | N/A | kW | At minimum heat output: single stage heat output and no room temperature control | No | |
elSB | 0.00016 | kW | In standby mode: Two or more manual stages, no room temperature control | No | |
with mechanic thermostat room temperature control | No | ||||
with electronic room temperature control | No | ||||
electronic room temperature control plus day timer | No | ||||
electronic room temperature control plus week timer | Yes | ||||
Other control options (multiple selections possible) | room temperature control, with presence detection | No | |||
room temperature control, with open window detection | Yes | ||||
with distance control option | No | ||||
with adaptive start control | No | ||||
with working time limitation | No | ||||
with black bulb sensor | No |