Declaration of Performance - Zehnder EVO 4 HRV / EVO 4 HRV PR
Release date: 15/11/2024
Product Datasheet According to Regulation (EU) NO.1254/2014 – ANNEX IV
Supplier's name or trade mark | Zehnder Group | Zehnder Group | Zehnder Group | Zehnder Group | ||||||||
Supplier's model identifier | Zehnder EVO 4 HRV / EVO 4 HRV PR | Zehnder EVO 4 HRV / EVO 4 HRV PR | Zehnder EVO 4 HRV / EVO 4 HRV PR | Zehnder EVO 4 HRV / EVO 4 HRV PR | ||||||||
SEC [kWh/(m²a)] specific energy consumption (cold, average, warm) | -65,9 | -39,8 | -13,3 | -66,7 | -40,5 | -13,8 | -68,2 | -41,7 | -14,8 | -71 | -43,8 | -16 |
SEC class (cold, average, warm) climate | A+ | A | E | A+ | A | E | A+ | A | E | A+ | A+ | E |
Typology of unit of ventilation | UVR bidirectional | |||||||||||
Typology of drive installed | Multi-speed control | Multi-speed control | Variable speed control | Variable speed control | ||||||||
Type of heat recovery system | Heat Recovery Static | Heat Recovery Static | Heat Recovery Static | Heat Recovery Static | ||||||||
Thermal efficiency [%] | 88,3 | 88,3 | 88,3 | 88,3 | ||||||||
Maximum flow rate [m³/h] | 400 | 400 | 400 | 400 | ||||||||
Electric power input of the fan drive [W] | 236,6 | 236,6 | 236,6 | 236,6 | ||||||||
Level of power acoustics (LWA) [dB(A)] | 49 | 49 | 49 | 49 | ||||||||
Reference flow [m³/h] | 280 | 280 | 280 | 280 | ||||||||
Reference pressure difference [Pa] | 50 | 50 | 50 | 50 | ||||||||
Specific Power Input of reference flow (SPI) [W/(m³/h)] | 0,34 | 0,34 | 0,34 | 0,34 | ||||||||
Control factor and typology installed or destined to be installed | "1 Manual control" | "0,95 Timer" | "0,65 Control of demand local" | "0,85 Control environmental centralized" | ||||||||
Maximum internal and external leakage rate declared [%] | Internal: 2,7 External: 4,2 |
Internal: 2,7 External: 4,2 |
Internal: 2,7 External: 4,2 |
Internal: 2,7 External: 4,2 |
||||||||
Position and description of the warning of the filter visual | Warning in the screen of the unit or controller of hall | Warning in the screen of the unit or controller of hall | Warning in the screen of the unit or controller of hall | Warning in the screen of the unit or controller of hall | ||||||||
Internet address for technical documentation | www.zehnder.it | |||||||||||
Annual electricity consumption by climate (cold, average, warm) per surface area of 100 m² (AEC) [kWh/a] | 1008 | 471 | 426 | 966 | 429 | 384 | 890 | 353 | 308 | 762 | 225 | 180 |
Annual heating savings in a (cold, average, warm) climate for an apartment with a surface area of 100 m² (AHS) [kWh/a] | 7600 | 4454 | 1757 | 7638 | 4477 | 1765 | 7714 | 4521 | 1783 | 7870 | 4611 | 1820 |
Important notice
Ensure there are air filters to keep the recovery unit's energy efficiency high, and regularly carry out cleaning and replacement maintenance. Read the instructions in the use and maintenance manual.
Warning
Always ensure a filter is used. To prevent reduced effectiveness of your energy recovery ventilation, be sure to clean dirt and dust from the filter and heat exchange element at regular intervals. See the operating instructions manual.