P56201BUF Floor Heating Thermostat
User Manual
Introduction
The P56201BUF thermostat is designed for controlling underfloor heating.
Important Information
- Read the thermostat manual carefully before using the device for the first time.
- Turn off power before installing the thermostat!
- Follow prescribed standards during installation.
Technical Specifications
Dimensions: 86 mm × 86 mm × 43 mm
- Switched load: max. 230 V AC; 16 A for resistive load
- Temperature measurement: 0 °C to 95 °C, 0.5 °C resolution
- Temperature setting: 1 °C to 70 °C, in 0.5 °C increments
- Temperature differential setting: 0.5 °C to 2.5 °C, in 0.5 °C increments
- Calibration of set temperature: -9 °C to 9 °C, in 1 °C increments
- Power supply: 230 V
- Enclosure rating: IP20
- Accessories: 3 m floor sensor (ø 8 mm), installation equipment
- WiFi frequency: 2.4 GHz, max. 25 mW e.i.r.p.
Description of the Thermostat Screen – Icons and Buttons
- ?1: Day of the week indicator.
- 1-72: Number of the day of the week (1 – Monday, 2 – Tuesday, 3 – Wednesday, 4 – Thursday, 5 – Friday, 6 – Saturday, 7 – Sunday).
- ⚙️3: SET icon: Indicates the screen is showing the set temperature for the current mode.
- ?4: Internal Sensor Icon: Appears if the screen shows the current room temperature from the internal sensor.
- ?️5: External Sensor Icon: Appears if the screen shows the temperature from the floor sensor. In a mode with both sensors active, holding the ⏻ button for 3 seconds displays the floor sensor temperature.
- ?️6: Weekly Mode Icon: Indicates that Weekly Mode is active.
- ☰7: Menu Button: Switches between Weekly and Manual Mode.
- ?8: Manual Mode Icon: Indicates that Manual Mode is active.
- ⏰9: Clock Button: Sets the time.
- ✈️10: Holiday Mode Icon: Indicates that Holiday Mode is active.
- ?11: Heating Icon: Appears when the thermostat is actively heating the room.
- ⏻12: ON/OFF Button.
- ?13: Open Window Function Icon: Indicates the open window function is active.
- ⬇️14: Down Arrow Button (V): Used to move down.
- ⬆️15: Up Arrow Button (∧): Used to move up.
- ?16: Child Lock Icon: Indicates that child lock is active.
- 17: Current room temperature display.
- 18: °C unit of temperature.
- 19: Current time display.
- ☁️20: Cloud Connection Icon: Indicates connection to the Cloud (AP).
- ?21: WiFi Connection Icon: Indicates connection through Wi-Fi (EZ).
- ⏳22: Time Period Icon: Indicates which time period of Weekly Mode is currently active.
- 23: Location of the indoor temperature sensor indicator.
Installing the Thermostat
Attention: Before changing the thermostat, disconnect the heating system from the mains power in your flat. This will prevent potential injury by electric current.
Placement of the Thermostat: The placement of the thermostat significantly affects its functioning. Choose a location where members of the family spend most of their time, preferably on the inside wall where air circulates freely, with no direct sunlight. Do not place the thermostat in the vicinity of heat sources (such as TV sets, radiators, fridges), or close to a door (due to frequent shocks or vibrations). If you do not follow these recommendations, the thermostat will not maintain room temperature correctly.
- Use a screwdriver to press on the internal lock and slide out the metal frame. If necessary, carefully disconnect the internal connector joining the two parts of the thermostat together.
- Install the mounting plate onto a suitable junction box, e.g. KU 68.
- Connect the wires leading out of the junction box to the marked terminals on the thermostat in accordance with the wiring diagram. Reconnect the internal connector, fit the thermostat back onto the mounting plate and secure it with the metal frame.
- Replace the front cover.
Wiring Diagram
- LOAD: connected device
- N, L: thermostat's power supply
- NTC: floor sensor
Mobile Application
The thermostat can be controlled using a mobile application for iOS or Android. Download the EMOS GoSmart app for your device.
Download on the App Store | GET IT ON Google Play
Tap the Log In button if you've used the app before. Otherwise, tap the Sign Up button and register.
Pairing with the Mobile Application & Temperature Programmes
Pairing with the Mobile Application
Long-press both the ☰ and ⏻ buttons on the thermostat simultaneously. The ? and ☁️ icons on the thermostat screen will start flashing; the thermostat is now in pairing mode.
In the app, tap "Add Device", then select "GoSmart" and tap the "Thermostat underfloor P56201BUF" icon.
Follow the on-screen instructions in the app to enter your 2.4 GHz Wi-Fi network name and password. The gateway will pair with the app within 2 minutes.
Note: If the thermostat fails to pair, repeat the entire process from the start. 5 GHz Wi-Fi networks are not supported.
Temperature Programmes
The type of temperature programme can be chosen in the Calendar Mode tab in EMOS GoSmart settings.
Types of temperature programmes:
- 5 + 2 (Mon-Fri + Sat-Sun): Allows setting a fixed temperature for 5 workdays and 2 weekend days. Up to 6 time periods per day type.
- 6 + 1 (Mon-Sat + Sun): Allows setting a fixed temperature for 6 days (Monday to Saturday) and 1 day (Sunday). Up to 6 time periods per day type.
- 7 days: Allows setting a fixed temperature for all 7 days. Up to 6 time periods per day.
Time periods can be set in the Weekly Mode Settings tab in the EMOS GoSmart app. The set temperature will be active until the next time period.
Example Schedule:
Time Period | Time | Temperature |
---|---|---|
1st time period | 3:00 | 16 °C |
2nd time period | 6:00 | 20 °C |
3rd time period | 9:00 | 17 °C |
4th time period | 12:00 | 19 °C |
5th time period | 14:00 | 23 °C |
6th time period | 22:00 | 17 °C |
Advanced Settings
Temperature Calibration
The thermostat sensor can be calibrated to optimize accuracy. Calibration can be set in EMOS GoSmart from -9 °C to 9 °C with 1 °C resolution.
Example: Setting calibration to +1 °C will display 23 °C if the room temperature is 22 °C.
Temperature Differential
This is the temperature difference required for switching the heating system on and off (hysteresis).
- Internal sensor differential: 0.5 °C to 2.5 °C.
- Floor sensor differential: 1 °C to 9 °C (via EMOS GoSmart app).
Example: With a set temperature of 20 °C and a differential of 2 °C, heating activates when the room drops to 18 °C and switches off at 22 °C.
Temperature Limits for Manual Thermostat Settings
- Maximum setting limit: 20 °C to 70 °C (1 °C resolution).
- Minimum setting limit: 1 °C to 20 °C (1 °C resolution).
Temperature Protection
- High-temperature protection: Sets the maximum temperature the thermostat heats the system to. Example: If set to 45 °C with a 2 °C limit, the relay switches off at 45 °C and on at 43 °C.
- Low-temperature protection: Sets the lowest desired room temperature. If the temperature drops below this value, the thermostat automatically starts heating. Can be set from 1 °C to 10 °C.
Status of the Device after Reconnecting to Power after a Power Outage
- Same as before: Thermostat returns to its previous state.
- Off: Thermostat stays off.
- On: Thermostat turns on.
Active Temperature Sensor
Selects which sensor detects temperature: internal sensor, floor sensor, or both.
Child Lock
Activated/deactivated via the EMOS GoSmart app or by holding the ⬇️ button for 3 seconds. A ? icon will appear on the screen when active.
Thermostat Screen Brightness in Standby Mode
Adjustable in settings (0 = screen off, 1 = slight illumination, 2 = strong illumination).
Open Window Function
If a sudden temperature drop is detected (e.g., open window), heating stops. Heating resumes after a set time or when the window is closed. Can be set/turned off on the thermostat screen.
Setting Modes and Functions (Active Screen)
Current Time and Day of the Week: Use ☰, ⬆️, ⬇️ buttons to set minutes, hours, and day.
Weekly Mode: Press and hold ☰ for 3 seconds to set time periods (hour, minute, temperature) for workdays and weekend days.
Holiday Mode: Press and hold ✈️ for 3 seconds to set ON/OFF, interval, and temperature for extended periods.
Setting Modes and Functions (Inactive Screen - Advanced Settings A)
Turn off the screen using the ⏻ button. Press and hold ☰ for 3 seconds to access advanced settings (A1-AE).
- A1 - Temperature calibration: -9 °C to 9 °C.
- A2 - Temperature differential: 0.5 °C to 2.5 °C.
- A3 - Screen child lock: 0 (off) or 1 (on). Default: 0.
- A4 - Status after power outage: 0 (same), 1 (off), 2 (on). Default: 0.
- A5 - Screen brightness: 0, 1, or 2. Default: 2.
- A6 - Calendar Mode selection: 0 (5+2), 1 (6+1), 2 (7 days). Default: 0.
- A7 - Minimum temperature setting: 1 °C to 10 °C. Default: 5 °C.
- A8 - Maximum temperature setting: 20 °C to 70 °C. Default: 35 °C.
- A9 - Low-temperature protection: 1 °C to 10 °C or off. Default: 5 °C.
- AA - High-temperature protection (external sensor): 20 °C to 70 °C or off. Default: 45 °C.
- AB - High-temperature protection limit (sensor): 1 °C to 9 °C. Default: 2 °C.
- AC - Open Window function (temperature): 10 °C to 20 °C or off. Default: off.
- AD - Open window function (interval): 10 to 20 minutes. Default: 10 minutes.
- AE - Reset: Hold ⏻ for 5 seconds to reset to factory settings.
Setting Modes and Functions (Inactive Screen - Advanced Settings B)
Turn off the screen using the ⏻ button. Press and hold ⚙️ for 3 seconds to access advanced settings (BN, Bo).
- BN - Active temperature sensor: N1 (internal), N2 (floor), N3 (both). Default: N1.
- Bo - Product information: Non-adjustable.
Troubleshooting FAQ
The screen displays:
- E1 - fault of the indoor temperature sensor.
- Reset the thermostat.
- Return the thermostat.
- E2 - fault of the floor sensor.
- Reset the thermostat.
- Check that the sensor is connected properly. Check the settings of the active sensor in the thermostat's menu.
Upkeep and Maintenance
The product is designed to serve reliably for many years if used properly. Here are some tips for proper operation:
- Read the manual carefully before using this product.
- Do not expose the product to direct sunlight, extreme cold, humidity, and sudden changes in temperature, as this would reduce measuring accuracy.
- Do not place the product in locations prone to vibrations and shocks, as these may cause damage.
- Do not subject the product to excessive force, impacts, dust, high temperatures, or humidity, as doing so may cause malfunction, shorten battery life, damage batteries, or deform plastic parts.
- Do not expose the product to rain or high humidity, dropping, or splashing water.
- Do not place any open flame sources on the product, e.g., a lit candle, etc.
- Do not place the product in places with inadequate air flow.
- Do not insert any objects in the product's vents.
- Do not tamper with the internal electric circuits of the product, as doing so may damage the product and will automatically void the warranty. The product should only be repaired by a qualified professional.
- To clean the product, use a slightly moistened soft cloth. Do not use solvents or cleaning agents, as they could scratch the plastic parts and cause corrosion of the electric circuits.
- Do not immerse the product in water or other liquids.
- In the event of damage or defect of the product, do not make any repairs by yourself. Have it repaired in the shop where you bought it.
- This device is not intended for use by persons (including children) whose physical, sensory, or mental disability or lack of experience and expertise prevents safe use, unless they are supervised or instructed in the use of the appliance by a person responsible for their safety. Children must always be supervised to ensure they do not play with the device.
♻️Disposal: Do not dispose with domestic waste. Use special collection points for sorted waste. Contact local authorities for information about collection points. If electronic devices are disposed of on landfill, dangerous substances may reach groundwater and subsequently the food chain, which could affect human health.