FIBARO DIMMER 2

Read this manual before attempting to install the device! Failure to observe recommendations included in this manual may be dangerous or cause a violation of the law. The manufacturer, Fibar Group S.A. will not be held responsible for any loss or damage resulting from not following the instructions of operating manual.! Danger of electrocution!

FIBARO DIMMER 2 - Elektroimportøren AS

Connecting the FIBARO Dimmer 2 in a manner inconsistent with manual may cause risk to health, life or material damage. When connecting FIBARO Dimmer 2 act in accordance with the following rules: • Connect only in accordance with one of the diagrams, • Dimmer 2 should be installed in a wall switch box compliant with a

PDF preview unavailable. Download the PDF instead.

smart living fibaro z-wave fgd-212-en-t-v1.3
O P E R AT I N G
EN
MANUAL

FIBARO DIMMER 2
FGD-212

CONTENTS

#1:Description and features

4

#2:Supported loads

5

#3:FIBARO Bypass 2 (FGB-002)

7

#4:Installation

8

#5:Adding/removing the device

11

#6:Operating the device

12

#7:Calibration

15

#8:Power and energy consumption 16

v1.3 - firmware 3.5

#9:Associations

17

#10:Z-Wave range test

18

#11:Error modes

19

#12:Additional functionality

21

#13:Advanced parameters

22

#14:Specifications

33

#15:Regulations

34

3
Important safety information
Read this manual before attempting to install the device!
! Failure to observe recommendations included in this manual
may be dangerous or cause a violation of the law. The manufacturer, Fibar Group S.A. will not be held responsible for any loss or damage resulting from not following the instructions of operating manual.
Danger of electrocution! Dimmer 2 is designed to operate in electrical home installation. Faulty connection or use may result in fire or electric shock. All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations. Even when the device is turned off, voltage may be present at its terminals. Any maintenance introducing changes into the configuration of connections or the load must be always performed with disabled fuse
General information about the FIBARO System
FIBARO is a wireless smart home automation system, based on the Z-Wave protocol. All of available devices can be controlled through a computer (PC or Mac), smartphone or tablet. Devices are not only receivers, but can also repeat the signal, increasing the Z-Wave network's range. It gives advantage over traditional wireless systems that require direct link between transmitter and receiver, as a result the construction of the building could affect network's range negatively. Every FIBARO network has its unique identification number (home ID). Multiple independent networks can exist in the building without interfering. Transmission security of FIBARO System is comparable to wired systems. Z-Wave technology is the leading solution in smart home automation. There is a wide range of Z-Wave devices that are mutually compatible, independently of manufacturer. It gives the system the ability to evolve and expand over time. For more information visit: www.fibaro.com.


4
#1:Description and features

Remotely controlled light dimming module is designed to work with various types of light sources. It may be connected to two-wire or three-wire configuration so it can operate with or without neutral lead. FIBARO Dimmer 2 can switch or dim connected light source either through radio waves or through the wall switch connected directly to it.
New FIBARO Dimmer 2 is equipped with an algorithm of smart light source detection which makes configuration easier and ensures high compatibility of the device. It may be used as a switch with nondimmable light sources (in 3-wire connection).

i NOTE
This device may be used with all devices certified with Z-Wave certificate and should be compatible with such devices produced by other manufacturers.

Main features of FIBARO Dimmer 2: · Compatible with any Z-Wave or Z-Wave+ Controller, · Controlled by FIBARO Home Center or any other Z-Wave controller, · Advanced microprocessor control, · Implemented algorithm of smart light source detection, · Auto-adjustment of the appropriate control mode to connected
load, · Active power and energy metering functionality, · Soft start function, · Memory of the last lighting level settings, · Works with various types of switches ­ momentary, toggle,
three-way, etc. · Active element: semiconductor electronic switch, · To be installed in wall switch boxes of dimensions allowing for
installation, conforming to provisions of applicable regulations, · FGD-212 is an extension unit.

FIBARO Dimmer 2 is a fully compatible Z-Wave PLUS device.

Description and features

5
#2:Supported loads

As a dimmer it operates under the following loads: · 230V operated conventional incandescent and halogen light
sources · 12V operated ELV halogen lamps and dimmable LED bulbs (with
electronic transformers) · 12V operated MLV halogen lamps (with ferromagnetic
transformers) · dimmable LED bulbs · dimmable compact fluorescent CFL tube lamps · supported dimmable light sources (power factor > 0.5) with
minimal power of 5VA using FIBARO Bypass 2 (depending on the type of load)
Without dimming function it may work with: · compact fluorescent CFL tube lamps with electronic ballast · fluorescent tube lamps with electronic ballast · LED bulbs (power factor > 0.7) · supported light sources (power factor > 0.5) with minimal power
of 5VA using FIBARO Bypass 2 (depending on the type of load)

! CAUTION
FIBARO Dimmer 2 supports only compact fluorescent tube lamps and fluorescent tube lamps with electronic ballast. Do not connect other types of fluorescent lamps!
i NOTE
You will find more about FIBARO Bypass 2 in chapter #3 on page 7.

Applied load and the Dimmer 2 itself may be damaged if
! the applied load is inconsistent with the technical specifications!
When connecting FIBARO Dimmer 2 act in accordance with the following rules:
· Do not connect loads greater or less than those recommended,
· Do not connect different types of light sources simultaneously,
· Do not connect the power supply without a load,
· Do not connect more than one transformer with Dimmer 2 output,
· When using magnetic transformer load it with 50% of its nominal power at minimum,
· Minimize number of electronic transformers in a circuit, noises caused by them in electrical grids may affect Dimmer's operation.

Supported loads

6
i NOTE
Some types of the LED bulbs and compact fluorescent lamps are designed to work in leading edge operating mode.

FIBARO Dimmer 2 uses different operating modes to control following types of loads: · ,,Trailing edge" for resistive loads (R) · ,,Trailing edge" for resistive-capacitive loads (RC) · ,,Leading edge" for resistive-inductive loads (RL)

Recommended values of power for supported loads:

Supported load types

220-240V~

Resistive loads
Conventional incandescent and halogen light sources Resistive-capacitive loads
Fluorescent tube lamp (compact / with electronic ballast), electronic transformer, LED Resistive-inductive loads
Ferromagnetic transformers

50-250W 50-200VA 50-220VA

Supported loads

7
#3:FIBARO Bypass 2 (FGB-002)

FIBARO Bypass 2 (FGB-002) is a device designed to work with FIBARO Dimmer 2 (FGD-212). It should be used in case of connecting LED bulbs or energy saving compact fluorescent lamps. FIBARO Bypass 2 prevents flickering of the LED lights and glowing of the turned off compact fluorescent lamps.
In the case of 2-wire connection, FIBARO Bypass 2 allows to reduce minimum power of load required by the Dimmer 2 for correct operation. FGB-002 provides powering of the Dimmer 2 in case of controlling the low loads of minimum power down to 5VA (for cos>0.5).

Device installation:
1. Switch off the mains voltage (disable the fuse).
2. Connect the Bypass 2 in accordance with ,,Installation" on page 8.
3. Follow the Dimmer 2 installation.
4. Force the calibration procedure with FIBARO Bypass 2 using RED menu position (see ,,Operating the device" on page 12) or through setting parameter 13 to 2 (see ,,Advanced parameters" on page 22).

Specifications:
Power supply: Operational temperature: Dimensions (L x W x H): Power consumption:

100-240 V~ 50/60 Hz 0-35°C 31 x 21,6 x 13 mm < 1,4 W

! CAUTION
Dimmer 2 was designed to work only with FGB-002. Connecting other devices may cause damage to the Dimmer 2.
! CAUTION
In the case of 2-wire connection do not connect load below minimal power without FGB-002.
! CAUTION
Bypass 2 works only with Dimmer 2 in trailing edge mode. Do not connect the Bypass to the Dimmer operating in leading edge mode.
! CAUTION
Bypass 2 is sensitive to the frequent changes of the state of Dimmer 2 (alternate switching on and off ). Significant changes in brightness should not be performed more than once per second.

FIBARO Bypass 2 (FGB-002)

8
#4: Installation

Connecting the FIBARO Dimmer 2 in a manner inconsistent
! with manual may cause risk to health, life or material damage.
When connecting FIBARO Dimmer 2 act in accordance with the following rules:
· Connect only in accordance with one of the diagrams,
· Dimmer 2 should be installed in a wall switch box compliant with a relevant national safety standards and with depth no less than 60mm,
· Electrical switches used in installation should be compliant with the relevant safety standards,
· Length of wires used to connect the control switch should not exceed 20m.

Notes for the diagrams:

L - terminal for live lead

S1 - terminal for switch no. 1 (has the option of entering the device in learning mode)

DIMMER
B

S2 - terminal for switch no. 2
Sx - terminal for power supply to the switch connected to the Dimmer 2

N - terminal for neutral lead

- output terminal of the Dimmer 2 (controlling connected light source)

B - service button (used to add/remove the device and navigate the menu)

Installation of the FIBARO Dimmer 2: 1. Switch off the mains voltage (disable the fuse). 2. Open the wall switch box. 3. Connect with one of following the diagrams:

Installation

single switch
l n

double switch
l n

DIMMER
B

DIMMER
B

Wiring diagram no. 1 - 2-wire connection

single switch
l n

double switch
l n

DIMMER
B

DIMMER
B

Wiring diagram no. 2 - 3-wire connection

2-wire connection
l n

3-wire connection
l n

BYPASS

BYPASS

DIMMER
B

DIMMER
B

Wiring diagram no. 3 - connecting FGB-002

9
i NOTE
Switch connected to the S1 terminal is a master switch. It activates the basic functionality of the Dimmer 2 (turning the light on/off, dimming) and starts the learning mode (Add/Remove). The switch connected to the S2 terminal is an optional switch and pushing it without changing the configuration parameters will not affect the status of the device. Functionality of the switches can be reversed by adjusting advanced parameter (see ,,Advanced parameters" on page 22).
Installation

10
i NOTE
It is not recommended to install different types of wall switches (momentary, toggle, etc.) in a 3-way connection.

1

3

13

P

P2

1

3

P

Wiring diagram no. 4 - 3-way switch connection

DIMMER
B

DIMMER
B

i NOTE
After switching on the mains voltage LED indicator will signal Z-Wave network inclusion state with a colour: GREEN - device added RED - device not added RED/GREEN ALTERNATELY- Z-Wave error
Installation

Wiring diagram no. 5 - momentary wall switches connection
4. After verifying correctness of connection switch on the mains voltage,
5. Wait around 30s for the calibration process to end (see ,,Calibration" on page 15), light may blink during the process,
6. After successful calibration the device will be turned off by default, 7. Add the device to the Z-Wave network (see ,,Adding/removing the
device" on page 11), 8. Turn off the mains voltage, then arrange the device and its anten-
na in a wall switch box, 9. Close the wall switch box and turn on the mains voltage.
Tips for arranging the antenna: · Locate the antenna as far from metal elements as possible
(connecting wires, bracket rings, etc.) in order to prevent interferences. · Metal surfaces in the direct vicinity of the antenna (e.g. flush mounted metal boxes, metal door frames) may impair signal reception! · Do not cut or shorten the antenna - its length is perfectly matched to the band in which the system operates.

11
#5:Adding/removing the device

Adding (Inclusion) - Z-Wave device learning mode, allowing to add the device to existing Z-Wave network. To add the device to the Z-Wave network: 1. Place the Dimmer 2 within the direct range of your Z-Wave
controller. 2. Identify switch no. 1 (turns the light on) or the B-button (located
on the device's housing). 3. Set the main controller in (security/non-security) add mode (see
the controller's manual). 4. Quickly, three times press switch no. 1 or the B-button. 5. Wait for the adding process to end. 6. Successful adding will be confirmed by the Z-Wave controller's
message.
Removing (Exclusion) - Z-Wave device learning mode, allowing to remove the device from existing Z-Wave network. To remove the device from the Z-Wave network: 1. Place the Dimmer 2 within the direct range of your Z-Wave
controller. 2. Identify switch no. 1 (turns the light on) or the B-button (located
on the device's housing). 3. Set the main controller in remove mode (see the controller's
manual). 4. Quickly, three times press switch no. 1 or the B-button. 5. Wait for the removing process to end. 6. Successful removing will be confirmed by the Z-Wave controller's
message. 7. Dimmer 2 will start the calibration process (see ,,Calibration" on
page 15).

i NOTE
For toggle switches in default configuration perform six position changes.
i NOTE
In case of problems related to unknown configuration or type of external switch use the B-button to add/ remove.

! CAUTION

While adding the

Dimmer 2 to the

network

with

connected toggle

switch, ensure that

all switch contact is

open (off ). Otherwise

it will prevent adding/

removing the device

to/from the network.

i NOTE
Removing the Dimmer 2 from the Z-Wave network restores all the default parameters of the device, but does not reset power metering data.

i NOTE
Adding/removing is not possible during the calibration procedure.

i NOTE
Adding in security mode must be performed up to 2 meters from the controller.

Adding/removing the device

12
#6:Operating the device
Controlling the Dimmer 2 using a switch: Momentary switch (after releasing the switch a spring automatically pushes back and disconnects the switch): · Turning the light ON/OFF: change the position of switch n o. 1. The
Dimmer 2 will be activated always at previously set brightness level, · Brightening/dimming the light: hold switch no. 1 down. When the switch is held down, the Dimmer 2 will always reach the extreme value of 1% or 99%, · Turning the light ON completely: fast double-click switch n o. 1. The Dimmer 2 will set the load at 99%. Toggle switch (operates as a two-position switch, it has no spring that would set one position of the switch): · Turning the light ON/OFF: toggle switch no. 1. The Dimmer 2 will be activated always at previously set brightness level, · Turning the light ON completely: toggle twice switch no. 1. The Dimmer 2 will set the load at 99%.
Controlling the Dimmer 2 using FIBARO Home Center controller: After adding the Dimmer 2 to the network, it will be represented in the FIBARO Home Center controller by the following icon:
Dimming/brightening is performed by moving the slider. The current status of the Dimmer 2 is shown on the bar indicator. Turning the device ON/OFF ­ ON and OFF icons are used for setting the last saved state or turning off the Dimmer 2.
Operating the device

Controlling the Dimmer 2 using a command: ALL ON/ALL OFF in non-secure mode:
The Dimmer 2 responds to commands ALL ON/ALL OFF that may be sent by the Z-Wave controller. ALL ON/ALL OFF commands are usually implemented in the remote controllers using Z-wave protocol, and they are used to issue commands directed to the entire system. By default, both commands ALL ON and ALL OFF are accepted. Settings may be changed by modifying the value of parameter 11 (see ,,Advanced parameters" on page 22). In this way the user may determine to which commands the device should respond.
Resetting the Dimmer 2:
1. Disconnect the power supply. 2. Remove the Dimmer 2 from the wall switch box. 3. Connect the power supply. 4. Locate the B-button on the housing. 5. Press and hold the B-button to enter the menu mode. 6. Wait for the visual LED indicator to turn yellow. 7. Quickly release and click the B-button again. 8. After few seconds the device will be restarted, which is signalled
with the red LED indicator colour. 9. The device enters the calibration mode.
Controlling the Dimmer 2 using the B-button:
FIBARO Dimmer 2 is equipped with a B-button, which allows to use the MENU mode and additionally perform the following actions: 1x click: · alarm mode cancellation (flashing alarm) · exit the error mode · select the desired MENU option (if MENU mode is active) 3x click: · send the Node Info Z-Wave command frame (adding/removing) Holding: · enter the MENU mode (confirmed by the LED indicator)

13
i NOTE
Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary controller is missing or inoperable. Certain device removal can be achieved by the procedure of removing described in ,,Adding/ removing the device" on page 11.

Operating the device

14 MENU mode & visual indications: FIBARO Dimmer 2 has a MENU with each position indicated by the specified LED indicator colour. In order to enter the menu press the B-button and hold for at least 2 seconds. While the B-button is still pressed, LED indicator colour will change in the following sequence: BLUE - initiate the load calibration procedure (see ,,Calibration" on page 15) RED - load calibration procedure with FIBARO Bypass 2 (see ,,Calibration" on page 15) WHITE - activate turning the load on/off using the B-button GREEN - reset the energy consumption data memory (see,,Power and energy consumption measurement" on page 16) VIOLET - initiate the Z-Wave network range test (see ,,Z-Wave range test" on page 18) YELLOW - reset the FIBARO Dimmer 2 to factory defaults Release the B-button to choose the desired function and confirm your choice with the B-button click.
Operating the device

15
#7: Calibration

Dimmer 2 is equipped with an algorithm of smart light source detection. Depending on the connected type of light source, it automatically adjusts an optimal control mode (leading edge for inductive loads, trailing edge for capacitive or resistive loads). The procedure of learning the light source type is called calibration.
Calibration automatically adjusts maximum and minimum light levels (parameter 1 and 2). However, the installer is obliged to verify the proper operation of the device, according to control modes description. There is a small probability that calibration settings will require a manual correction. In a 2-wire connection for loads other than resistive parameter 1 settings must be adjusted manually.
Calibration procedure is performed always after removing the device from the Z-Wave network. If the device is not included, after each power on/off calibration will occur. For the included device, calibration is performed in accordance with the parameter 35 settings.
Calibration may be forced:
· by setting parameter 13 to 1 or 2 (with/without FIBARO Bypass 2)
· through triple clicking and holding the main light switch (each hold for more than 5 seconds)
· by selecting the appropriate MENU option using the B-button (see ,,Operating the device" on page 12).
By default, calibration is performed without FIBARO Bypass 2. In case of connecting the Bypass 2, it is required to force the appropriate calibration procedure using B-button menu or through parameter 13. The device saves the last calibration enforcement mode (with or without Bypass 2).
The result of calibration will be confirmed with the LED indicator glowing in one of the following colours:
GREEN - Light source recognized as dimmable, dimming levels set, brightness may be controlled using the S1 switch.
YELLOW - Light source recognized as non-dimmable, possibility to turn ON/OFF connected light with default parameters settings.
RED - Calibration procedure failed. Possible reasons: lack of connected load or connected light source exceeds maximum power, which may be controlled by the Dimmer 2.
BLINKING RED - Calibration procedure failed. Possible reasons: installation failure or damaged load (causing activation of the overcurrent protection).

! CAUTION
Some types of LED and CF lamps are designed to operate in leading edge mode (with conventional dimmers). Information about proper operation mode of the bulb should be included in its manual. In this case you have to manually force the desired operating mode using parameter 30.
! CAUTION
During the calibration procedure, radio connection is disabled and the Dimmer 2 does not respond to any commands. It may cause temporary problems with communication in the Z-Wave network. After completing the calibration, communication with the module will be restored.

Calibration

16
#8:Power and energy consumption

! CAUTION
FIBARO Dimmer 2 in the 3-wire connection has the power and energy measurement function. In case of the 2-wire connection this function is available only for load of cos  0.99. In other cases power is estimated and can differ from actual power consumed by the device.
! CAUTION
FIBARO Dimmer 2 stores periodically (every 5 minutes) the consumption data in the device memory. Disconnecting the module from the power supply will not erase the energy consumption data.
i NOTE
Power measurement in the 2-wire connection does not include mains voltage fluctuations within +/- 10%.
* Measurements in this
case are only illustrative, returned values may differ from the actual measurement. In the case of reporting incorrect values change the values of parameters 58 and 59.

FIBARO Dimmer 2 allows for the active power and energy consumption monitoring. Data is sent to the main Z-Wave controller, e.g. Home Center. Measuring is carried out by the most advanced micro-controller technology, assuring maximum accuracy and precision.
Electric active power - power that energy receiver is changing into a work or a heat. The unit of active power is Watt [W].
Electric energy - energy consumed by a device through a time period. Consumers of electricity in households are billed by suppliers on the basis of active power used in given unit of time. Most commonly measured in kilowatt-hour [kWh]. One kilowatt-hour is equal to one kilowatt of power consumed over period of one hour, 1kWh = 1000Wh.

Resetting consumption memory: Dimmer 2 allows to erase stored consumption data in three ways: a) By resetting the device (see ,,Operating the device" on page 12). b)Using functionality of a Z-Wave controller (see the controller'smanual). c) Manually clearing the data using the following procedure:
1. Make sure that the device is connected to the power supply. 2. Press and hold the B-button for a few seconds, until LED indica-
tor glows GREEN. 3. Release the B-button. 4. Press the B-button briefly. 5. Energy consumption memory has been erased.

Table of power measurement accuracy:

FGD-212
resistive load
resistiveinductive load
resisitvecapacitive load

3-wire connection

Brightness>70%

Brightness<70%

+/- (0.5 % + 0.2W)

+/- (2 % + 0.2W)

+/- (0.5 % + 0.2W)

+/- (2 % + 0.2W)

+/- (0.5 % + 0.2W)

+/- (2 % + 0.2W)

2-wire connection

Brightness>70%

Brightness<70%

+/- (2 % + 0.2W)

+/- (4 % + 0.2W)

Power

Power

metering

metering

approximate* approximate*

Power

Power

metering

metering

approximate* approximate*

Power and energy consumption

17
#9: Associations

Association (linking devices) - direct control of other devices within the Z-Wave system network using the wall switch connected to the Dimmer 2.
The association enables the Dimmer 2 to control directly a device included in Z-Wave network e.g. other Dimmer, Relay Switch, Roller Shutter or scene (may be controlled only through a Z-Wave controller).
The Dimmer 2 provides the association of five groups:
1st Association Group ,,Lifeline" reports state of the device. Main Z-Wave+ network controller should be added to this group. The ,,Lifeline" group can handle only one device. It is not recommended to modify this group.
2nd Association Group ,,On/Off (S1)" is assigned to switch no. 1. Sends BASIC command class frame according to the state of the device.
3rd Association Group ,,Dimmer (S1)" is assigned to switch no. 1. Sends MULTILEVEL SWITCH command class frame. Allows sending dim/brighten command to associated devices.
4th Association Group ,,On/Off (S2)" is assigned to switch no. 2. Sends BASIC command class frame according to the state of the device.
5th Association Group ,,Dimmer (S2)" is assigned to switch no. 2. Sends MULTILEVEL SWITCH command class frame. Allows sending dim/brighten command to associated devices.
Dimmer 2 in 2nd to 5th group allows to control 8 regular or multichannel devices per an association group, with the exception of "LifeLine" that is reserved solely for the Z-Wave controller and hence only 1 node can be assigned.
It is not recommended to associate more than 10 devices in general, as the response time to control commands depends on the number of associated devices. In extreme cases, system response may be delayed.
To add an association (using the Home Center controller):
1. Go to device options by clicking the icon:
2. Select the ,,Advanced" tab.
3. Specify to which group and what devices are to be associated.
4. Wait for the configuration process to end. Sending relevant information to devices added to associated groups may take even a few minutes.

i NOTE
Association ensures direct transfer of control commands between devices, is performed without participation of the main controller and requires associated device to be in the direct range.
i NOTE
The Dimmer 2 supports the operation of multichannel devices. Multichannel devices are devices that include two or more circuits inside one physical unit.
Associations

18
#10:Z-Wave range test

! CAUTION
To make Z-Wave range test possible, the device must be added to the Z-Wave controller. Testing may stress the network, so it is recommended to perform the test only in special cases.
i NOTE
Communication mode of the Dimmer 2 may switch between direct and one using routing, especially if the device is on the limit of the direct range.

FIBARO Dimmer 2 has a built in Z-Wave network main controller's range tester.
Follow the below instructions to test the main controller's range:
1. Press and hold the B-button until the visual indicator glows violet.
2. Release the B-button.
3. Press the B-button again, briefly.
4. Visual indicator will indicate the Z-Wave network's range (range signalling modes described below).
5. To exit Z-Wave range test, press the B-button briefly.
Z-Wave range tester signalling modes:
Visual indicator pulsing green - Dimmer 2 attempts to establish a direct communication with the main controller. If a direct communication attempt fails, the device will try to establish a routed communication, through other modules, which will be signalled by visual indicator pulsing yellow.
Visual indicator glowing green - Dimmer 2 communicates with the main controller directly.
Visual indicator pulsing yellow - Dimmer 2 tries to establish a routed communication with the main controller through other modules (repeaters).
Visual indicator glowing yellow - Dimmer 2 communicates with the main controller through the other modules. After 2 seconds the device will retry to establish a direct communication with the main controller, which will be signalled with visual indicator pulsing green.
Visual indicator pulsing violet - Dimmer 2 does communicate at the maximum distance of the Z-Wave network. If connection proves successful it will be confirmed with a yellow glow. It's not recommended to use the device at the range limit.
Visual indicator glowing red - Dimmer 2 is not able to connect to the main controller directly or through another Z-Wave network device (repeater).

Z-Wave range test

19
#11:Error modes

Description of error messages of the Dimmer 2
Events result from installation flaws, faulty light source operation or incorrect manual changes in advanced configuration. The device may stop responding to user's commands and actions, leaving the light source off. Message with information about the type of error is sent by default (using Z-Wave network).
Error messages:
A) OVERTEMPERATURE ERROR
Dimmer 2 features self-temperature measurement function. In case of reaching critical temperature, the load is turned off and the gateway receives an information about exceeding maximum temperature of the module.
B) LOAD ERROR
Dimmer 2 is equipped with functionality of detecting the burnt out bulb. In case of such situation, Dimmer 2 sends the notification about load failure. Described function is not available for values of parameter 58 different than 0.
Power variation is detected in accordance with the settings of parameters 15 and 16.
Example:
Parameter 15 set to 30%.
Parameter 16 set to 5 seconds.
Dimmer 2 will detect the change of load at the moment of power variation by 30% compared to standard power consumption (measured during the calibration) and after 5 seconds from brightness level stabilization.
This function is available only in a control mode compliant with the mode recognized during the calibration (parameter 14 set to 1).
Appearing of an error may be the result of not connecting the load. It may suggest burning out all of the loads connected to the Dimmer 2.
Damaged load should be immediately replaced. After connecting the new load, FIBARO Dimmer 2 will return to normal operation.
C) SURGE ERROR
Appearing of an error may be the result of electrical surges, incorrect load control (inductive load controlled in trailing edge mode) or connecting the prohibited type of load.

i NOTE
Pressing any of the connected switches or changing state of the device using the controller will exit error mode.
i NOTE
If parameter 35 is set to 3 or 4, the load will be calibrated again after turning on the load or an occurrence of LOAD ERROR, SURGE or OVERCURRENT error.

Error modes

20
D) OVERCURRENT ERROR
Appearing of an error may also be the result of rapid powering on the load. It may also occur if the soft-start functionality is disabled (parameter 34 set to 0) or as a result of the short circuit.
If parameter 37 is set to 1, the device will automatically try to turn on again.
If described error has been caused by the rapid powering on the load, then FIBARO Dimmer 2 will return to normal operation after reenabling.
After three unsuccessful automatic tries of turning on the load, Dimmer 2 will stay in OVERCURRENT error mode (module turned off ). In such situation, it is required to remove the failure (possible short circuit in the installation.) Otherwise, it is recommended to set the long soft-start (parameter 34 set to 2).
E) OVERLOAD ERROR
Appearing of an error is a result of connecting receivers with too much power consumption. In this case FIBARO Dimmer 2 will automatically turn off the lighting.
It is required to reduce power consumption of connected load (e.g. by reducing the number of receivers) and turn on the light source again by the wall switch or a Z-Wave command.
F) VOLTAGE DROP ERROR
Appearing of an error in a 2-wire connection may be the result of mains voltage drop or a too high brightness level of the light source.
If parameter 37 is set to 1, the device will automatically try to turn on again.
Voltage drop error suggests that parameter 2 value should be reduced until disappearing of the failure. You can also recalibrate the load using parameter 13.
After three unsuccessful automatic tries of turning on the load, Dimmer 2 will stay in VOLTAGE DROP error mode (module turned off ).
G) HARDWARE FAIL ERROR
Appearing of an error may be a result of serious hardware failure of the Dimmer 2. In this case the Dimmer 2 sets the maximum brightness level and the LED visual indicator starts blinking in red. All external actions (Z-Wave commands, pressing the switches, menu settings) will be ignored.
We recommend disconnecting the device from the power supply and contacting the customer service or to initiate the guarantee procedure.
This error may also appear as a result of enabling the Dimmer 2 without load connected to the output in 3-wire connection. It is not a dangerous situation. We recommend disabling the fuse, connecting the load and enabling the fuse again.
Error modes

21
#12:Additional functionality
Software update Dimmer 2 features remote software update (initiated by the main controller). Update status is signalled by the LED indicator with cyan colour: · slow blinking - transferring data via Z-Wave and saving to the
flash memory · fast blinking - copying data from the external memory to the
memory of the microcontroller
Operating alarm data frames FIBARO System allows user to set response of devices to alarm situations (response to data-frames ALARM_REPORT and SENSOR_ALARM_ REPORT). Dimmer 2 responds to the following types of alarms: · General Purpose Alarm - GENERAL PURPOSE ALARM · Smoke Alarm - ALARM CO2, ALARM CO, ALARM SMOKE · Water Flooding Alarm - ALARM WATER · Temperature Alarm - ALARM HEAT Alarm data-frames are sent by devices that are system sensors (e.g., flood sensors, smoke detectors, motion detectors, etc.). The device may respond in the following manner to received data-frames (settings are configured in configuration parameters, see ,,Advanced parameters" on page 22): 0 - DEACTIVATION - the device does not respond to alarm data frames 1 - DIMMER 2 ON - the device turns on after detecting an alarm 2 - DIMMER 2 OFF - the device turns off after detecting an alarm 3 - ALARM FLASHING - the device periodically changes its status to the opposite when it detects an alarm (lights on/off alternately)
Additional functionality

22
#13:Advanced parameters

CAUTION
! The maximum brightness level (parameter 2) must be greater than the minimum brightness level (parameter 1).

99%

99%

max

min

*

0%

1%

real scale
scale available to the user (virtual)
* incandescence level of dimmable compact fluorescent lamps

Dimmer 2 allows to customize its operation to user's needs. The settings are available in the FIBARO interface as simple options that may be chosen by selecting the appropriate box.
In order to configure FIBARO Dimmer 2 (using the Home Center controller):
1. Go to the device options by clicking the icon:
2. Select the ,,Advanced" tab.

GROUP 0 - The Dimmer 2 behavior - Basic functionalities
1. Minimum brightness level (parameter is set automatically during the calibration process)
The parameter can be changed manually after the calibration.

Available settings: 1-98 - percentage level of brightness

Default setting: 1

Parameter size: 1 [byte]

2. Maximum brightness level (parameter is set automatically during the calibration process)
The parameter can be changed manually after the calibration.

Available settings: 2-99 - percentage level of brightness

Default setting: 99

Parameter size: 1 [byte]

3. Incandescence level of dimmable compact fluorescent lamps
Virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%). The Dimmer 2 will set to this value after first switch on. It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources.

Available settings: 1-99 - percentage level of brightness

Default setting: 1

Parameter size: 1 [byte]

4. Incandescence time of dimmable compact fluorescent lamps
This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the incandescence functionality.

Available settings: 0-255 (0-25.5s)

Default setting: 0

Parameter size:

2 [bytes]

Advanced parameters

5. Automatic control - dimming step size
This parameter defines the percentage value of dimming step during the automatic control.

Available settings: 1-99 - dimming step percentage value

Default setting: 1

Parameter size: 1 [byte]

6. Automatic control - time of a dimming step
This parameter defines the time of single dimming step set in parameter 5 during the automatic control.

Available settings: 0-255 (0-2.55s, in 10ms steps) Default setting: 1 (10ms) Parameter size:

2 [bytes]

7. Manual control - dimming step size
This parameter defines the percentage value of dimming step during the manual control.

Available settings: 1-99 - dimming step percentage value

Default setting: 1

Parameter size: 1 [byte]

8. Manual control - time of a dimming step
This parameter defines the time of single dimming step set in parameter 7 during the manual control.

Available settings: 0-255 (0-2.55s, in 10ms steps) Default setting: 5 (50ms) Parameter size:

2 [bytes]

9. State of the device after a power failure The Dimmer 2 will return to the last state before power failure.

Available settings: 0 - the Dimmer 2 does not save the state before a power failure, it returns to ,,off" position

1 - the Dimmer 2 restores its state before power failure

Default setting: 1

Parameter size: 1 [byte]

10. Timer functionality (auto - off)
This parameter allows to automatically switch off the device after specified time from switching on the light source. It may be useful when the Dimmer 2 is installed in the stairway.

Available settings: 0 - Function disabled

1-32767 - time to turn off measured in seconds (1s-9.1h)

Default setting: 0

Parameter size: 2 [bytes]

23
i NOTE
Automatic control is performed through: - single push-button click - double push-button click - Z-Wave control frames
i NOTE
Manual control is performed through holding the push-button.

Advanced parameters

24
! CAUTION
Parameter 15 is relevant only when parameter 58 is set to 0 and the control mode is consistent with the mode set during the calibration process (parameter 30).

11. ALL ON/ALL OFF function
Parameter allows for activation/deactivation of Z-Wave commands enabling/disabling all devices located in direct range of the main controller.

Available settings: 0 - ALL ON not active, ALL OFF not active

1 - ALL ON not active, ALL OFF active

2 - ALL ON active, ALL OFF not active

Default setting:

255 - ALL ON active, ALL OFF active

255

Parameter size: 2 [bytes]

13. Force auto-calibration
Changing value of this parameter will force the calibration process. During the calibration parameter is set to 1 or 2 and switched to 0 upon completion.

Available settings: 0 - readout

1 - force auto-calibration of the load without FIBARO Bypass 2

2 - force auto-calibration of the load with FIBARO Bypass 2

Default setting: 0

Parameter size: 1 [byte]

14. Auto-calibration status (read-only parameter)
This parameter determines operating mode of the Dimmer 2 (automatic/manual settings).

Available settings: 0 - calibration procedure not performed or Dimmer 2 operates on manual settings

1 - Dimmer 2 operates on auto-calibration settings

Default setting: 0

Parameter size: 1 [byte]

15. Burnt out bulb detection
Function based on the sudden power variation of a specific value, interpreted as a LOAD ERROR.

Available settings: 0 - function disabled

1-99 - percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb)

Default setting: 30

Parameter size: 1 [byte]

16. Time delay of a burnt out bulb (parameter 15) or overload (parameter 39) detection
Time of delay (in seconds) for power variation detection, interpreted as a LOAD ERROR or OVERLOAD detection (too much power connected to the Dimmer 2).

Advanced parameters

25

Available settings: 0 - detection of a burnt out bulb disabled

1-255 - delay time in seconds

Default setting: 5

Parameter size: 2 [bytes]

19. Forced switch on brightness level
If the parameter is active, switching on the Dimmer 2 (S1 single click) will always set this brightness level.

Available settings: 0 - function disabled

1-99 - percentage level of brightness

Default setting: 0

Parameter size: 1 [byte]

GROUP 20 - Dimmer 2 operation - Switches 20. Switch type Choose between momentary, toggle and roller blind switch.

Available settings: 0 - momentary switch

1 - toggle switch

2 - roller blind switch - two switches operate the Dimmer 2 (S1 to brighten, S2 to dim)

Default setting: 0

Parameter size: 1 [byte]

21. The value sent to associated devices on single click
This parameter defines the value sent to devices associated with Dimmer 2 after its enabling.

Available settings: 0 - 0xFF value is sent, which will set associated devices to their last saved state

1 - current Dimmer 2 state is sent, which will synchronize brightness level of associated devices (other dimmers for example)

Default setting: 0

Parameter size: 1 [byte]

22. Assign toggle switch status to the device status
By default each change of toggle switch position results in action of Dimmer 2 (switch on/off ) regardless the physical connection of conntacts.

Available settings: 0 - device changes status on switch status change

1 - device status is synchronized with switch status

Default setting: 0

Parameter size: 1 [byte]

Advanced parameters

26
i NOTE
Parameter 24 values may be combined, e.g. 1+2=3 means that associations on switching ON or OFF the Dimmer 2 (single click) will not be sent.
i NOTE
Parameter 25 values may be combined, e.g. 1+2=3 means that associations on switching ON or OFF the Dimmer 2 (single click) will not be sent.

23. Double click option - set the brightness level to MAX

Available settings: 0 - double click disabled

1 - double click enabled

Default setting: 1

Parameter size:

1 [byte]

24. Command frames sent in 2nd and 3rd association groups (S1 associations)
Parameter determines, which actions will not result in sending frames to association groups.

Available settings: 0 - all actions send to association groups

1 - do not send when switching ON (single click)

2 - do not send when switching OFF (single click)

4 - do not send when changing dimming level (holding and releasing)

8 - do not send on double click

16 - send 0xFF value on double click

Default setting: 0

Parameter size: 1 [byte]

25. Command frames sent in 4th and 5th association groups (S2 associations)
Parameter determines, which actions will not result in sending frames to association groups.

Available settings: 0 - all actions send to association groups

1 - do not send when switching ON (single click)

2 - do not send when switching OFF (single click)

4 - do not send when changing dimming level (holding and releasing)

8 - do not send on double click

16 - send 0xFF value on double click

Default setting: 0

Parameter size: 1 [byte]

26. The function of 3-way switch
Switch no. 2 controls the Dimmer 2 additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch).

Available settings: 0 - 3-way switch function for S2 disabled

1 - 3-way switch function for S2 enabled

Default setting: 0

Parameter size: 1 [byte]

27. Associations in Z-Wave network security mode
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st Lifeline group.

Advanced parameters

Available settings: 0 - all groups (II-V) sent as non-secure

1 - 2nd group sent as secure

2 - 3rd group sent as secure

4 - 4th group sent as secure

8 - 5th group sent as secure

15 - all groups (II-V) sent as secure

Default setting: 15

Parameter size: 1 [byte]

28. Scene activation functionality SCENE ID depends on the switch type configurations.

Available settings: 0 - functionality deactivated

1 - functionality activated

Default setting: 0

Parameter size:

1 [byte]

SCENE ID value sent at specified configuration:

Momentary switches
SCENE ID: S1 input
16 : 1 x click 14 : 2 x click - : 3 x click 12 : hold 13 : release
Toggle switches
SCENE ID: S1 input
10 : OFF to ON 11 : ON to OFF 14 : 2 x click - : 3 x click
Roller blinds switches
SCENE ID: S1 input
10 : turn ON (1 x click) 13 : release 14 : 2 x click - : 3 x click 17 : brightening

SCENE ID: S2 input 26 : 1 x click 24 : 2 x click 25 : 3 x click 22 : hold 23 : release
SCENE ID: S2 input 20 : OFF to ON 21 : ON to OFF 24 : 2 x click 25 : 3 x click
SCENE ID: S2 input 11 : turn OFF (1 x click) 13 : release 14 : 2 x click 15 : 3 x click 18 : dimming

29. Switch functionality of S1 and S2
This parameter allows for switching the role of keys connected to S1 and S2 without changes in connection.

Available settings: 0 - standard mode

1 - S1 operates as S2, S2 operates as S1

Default setting: 0

Parameter size: 1 [byte]

27
i NOTE
Parameter 27 values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.
i NOTE
Enabling scene activation functionality may cause slight delay in response to external switches and sending associations.

Advanced parameters

28
! CAUTION
Modifications of parameters in GROUP 30 should be performed only by a qualified installer.

GROUP 30 - Dimmer 2 operation - Advanced functionality
30. Load control mode
This parameter allows to set the desired load control mode. The device automatically adjusts correct control mode, but the installer may force its change using this parameter.
Forced auto-calibration will set this parameter's value to 2.

Available settings: 0 - forced leading edge control

1 - forced trailing edge control

2 - control mode selected automatically (based on auto-calibration)

Default setting: 2

Parameter size: 1 [byte]

31. Load control mode recognized during auto-calibration (read only)

Available settings: 0 - leading edge

1 - trailing edge

Default setting: --

Parameter size:

1 [byte]

32. On/Off mode
This mode is necessary while connecting non-dimmable light sources. Setting this parameter to 1 automatically ignores brightening/ dimming time settings. Forced auto-calibration will set this parameter's value to 2.

Available settings: 0 - on/off mode disabled (dimming is possible)

1 - on/off mode enabled (dimming is not possible)

2 - mode selected automatically

Default setting: 2

Parameter size: 1 [byte]

33. Dimmability of the load (read only)
This parameter contains an information about possibility of dimming the load detected during calibration procedure.

Available settings: 0 - Load recognized as dimmable

1 - Load recognized as non-dimmable

Default setting: --

Parameter size: 1 [byte]

34. Soft-Start functionality Time required to warm up the filament of halogen bulb.

Available settings: 0 - no soft-start

1 - short soft-start (0.1s)

Default setting:

2 - long soft-start (0.5s)

1

Parameter size:

1 [byte]

Advanced parameters

29

35. Auto-calibration after power on
This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc.

Available settings: 0 - No auto-calibration of the load after power on

1 - Auto-calibration performed after first power on

2 - Auto-calibration performed after each power on

3 - Auto-calibration performed after first power on or after each LOAD ERROR alarm (no load, load failure, burnt out bulb), if parameter 37 is set to 1 also after alarms: SURGE (Dimmer 2 output overvoltage) and OVERCURRENT (Dimmer 2 output overcurrent)

4 - Auto-calibration performed after each power on or after each LOAD ERROR alarm (no load, load failure, burnt out bulb), if parameter 37 is set to 1 also after alarms: SURGE (Dimmer 2 output overvoltage) and OVERCURRENT (Dimmer 2 output overcurrent)

Default setting: 1

Parameter size: 1 [byte]

37. Behaviour of the Dimmer 2 after OVERCURRENT or SURGE
Occuring of errors related to surge or overcurrent results in turning off the output to prevent possible malfunction. By default the device performs three attempts to turn on the load (useful in case of momentary, short failures of the power supply).

Available settings: 0 - device permanently disabled until re-enabling by command or external switch

1 - three attempts to turn on the load

Default setting: 1

Parameter size: 1 [byte]

38. Brightness level correction for flickering loads
Correction reduces spontaneous flickering of some capacitive load (e.g. dimmable LEDs) at certain brightness levels in 2-wire installation.
In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust time of correction for flickering loads.

Available settings: 0 - automatic correction disabled

1-254 - duration of correction in seconds

255 - automatic correction always enabled

Default setting: 255

Parameter size: 2 [bytes]

Advanced parameters

30
i NOTE
Parameter 39 is relevant only when parameter 58 is set to 0.

39. Power limit - OVERLOAD
Reaching the defined value will result in turning off the load. Additional apparent power limit of 350VA is active by default.

Available settings: 0 - functionality disabled

1-350 - 1-350W

Default setting: 250

Parameter size:

2 [bytes]

i NOTE
Alarm state may be cancelled earlier, as a result of pressing the switch or sending the Z-Wave command frame.

GROUP 40 - Dimmer 2 operation - Alarms 40. Response to General Purpose Alarm

Available settings: 0 - No reaction

1 - Turn on the load

2 - Turn off the load

Default setting:

3 - Load blinking

3

Parameter size:

41. Response to Water Flooding Alarm

Available settings: 0 - No reaction

1 - Turn on the load

2 - Turn off the load

3 - Load blinking

Default setting: 2

Parameter size:

42. Response to Smoke, CO or CO2 Alarm

Available settings: 0 - No reaction

1 - Turn on the load

2 - Turn off the load

3 - Load blinking

Default setting: 3

Parameter size:

43. Response to Temperature Alarm

Available settings: 0 - No reaction

1 - Turn on the load

2 - Turn off the load

Default setting:

3 - Load blinking

1

Parameter size:

44. Time of alarm state
Available settings: 1-32767 (1-32767 seconds) Default setting: 600 (600s) Parameter size:

1 [byte] 1 [byte] 1 [byte] 1 [byte] 2 [bytes]

Advanced parameters

31

Alarm settings - reports 45. OVERLOAD alarm report (load power consumption too high)

Available settings: 0 - No reaction

1 - Send an alarm frame

Default setting: 1

Parameter size:

1 [byte]

46. LOAD ERROR alarm report (no load, load failure, burnt out bulb)

Available settings: 0 - No reaction

1 - Send an alarm frame

Default setting: 1

Parameter size:

1 [byte]

47. OVERCURRENT alarm report (short circuit, burnt out bulb causing overcurrent)

Available settings: 0 - No reaction

1 - Send an alarm frame

Default setting: 1

Parameter size:

1 [byte]

48. SURGE alarm report (Dimmer 2 output overvoltage)

Available settings: 0 - No reaction

1 - Send an alarm frame

Default setting: 1

Parameter size:

1 [byte]

49. OVERHEAT (critical temperature) and VOLTAGE DROP (low voltage) alarm report

Available settings: 0 - No reaction

1 - Send an alarm frame

Default setting: 1

Parameter size:

1 [byte]

GROUP 50 - Active power and energy reports 50. Active power reports The parameter defines the power level change that will result in a new power report being sent. The value is a percentage of the previous report.
Available settings: 0 - power reports disabled 1-100 (1-100%) - power report threshold
Default setting: 10 (10%) Parameter size: 1 [byte]

Advanced parameters

32
i NOTE
Parameter 58 is set to 0 after forced auto-calibration.
i NOTE
Parameter 59 works only when parameter 58 has a value other than 0.

52. Periodic active power and energy reports
Parameter 52 defines a time period between consecutive reports. Timer is reset and counted from zero after each report.

Available settings: 0 - periodic reports disabled 1-32767 (1-32767 seconds)
Default setting: 3600 (3600s) Parameter size:

2 [bytes]

53. Energy reports Energy level change which will result in sending a new energy report.
Available settings: 0 - energy reports disabled 1-255 (0.01-2.55 kWh) - report triggering threshold
Default setting: 10 (0.1 kWh) Parameter size: 2 [bytes]

54. Self-measurement
The Dimmer 2 may include active power and energy consumed by itself in reports sent to the main controller.

Available settings: 0 - Self-measurement inactive

1 - Self-measurement active

Default setting: 0

Parameter size:

1 [byte]

58. Method of calculating the active power
This parameter defines how to calculate active power. It is useful in a case of 2-wire connection with light sources other than resistive.

Available settings: 0 - measurement based on the standard algorithm

1 - approximation based on the calibration data

Default setting:

2 - approximation based on the control angle

0

Parameter size: 1 [byte]

59. Approximated power at the maximum brightness level
This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level.

Available settings: 0-500 (0-500W) - power consumed by the load at the maximum brightness level.

Default setting: 0

Parameter size: 2 [bytes]

Advanced parameters

#14: Specifications

Power supply:

100-240V~ 50/60Hz

Power consumption:

< 1.3W

Operational temperature: 0-35°C

For installation in boxes: Ø  50mm

Operational current:

0.25-1.1A

Device temperature protection:

105°C

Active element:

semiconductor electronic switch 

Device control:

remotely - radio waves directly - external switch

Radio protocol:

Z-Wave (500 series chip)

Radio signal power:

up to 1mW

Radio frequency:

868.4 or 869.8 MHz EU; 908.4, 908.42 or 916.0 MHz US; 921.4 or 919.8 MHz ANZ; 869.0 MHz RU;

Range:

up to 50 m outdoors up to 40 m indoors (depending on building materials)

Comply with EU directives: RoHS 2011/65/EU RED 2014/53/EU

Dimensions (L x W x H): 42.5 x 38.25 x 20.3 mm





33
i NOTE
Occasional flickering of the lighting may be the result of ripple-control signals from the electricity supplier. The occurrence and magnitude of this effect depends on the country, region and time of the day. The effect is more frequent in 2-wire installation, on low dimming levels and with LED light sources. Voltage drops, dips and harmonics may also cause flickering.
i NOTE
Radio frequency of individual device must be same as your Z-Wave controller. Check information on the box or consult your dealer if you are not sure.

 

Specifications

34 Regulations

#15: Regulations
This device complies with Part 15 of the FCC Rules
Operation is subject to the following two conditions: 1. This device may not cause harmful interference 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission's rules.
Industry Canada (IC) Compliance Notice
This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux normes d'exemption de licence RSS d'Industry Canada. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d'interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement.
Legal Notices
All information, including, but not limited to, information regarding the features, functionality, and/or other product specification are subject to change without notice. Fibaro reserves all rights to revise or update its products, software, or documentation without any obligation to notify any individual or entity. FIBARO and Fibar Group logo are trademarks of Fibar Group S.A. All other brands and product names referred to herein are trademarks of their respective holders.

35
DGT Warning Statement Article 12 Without permission, any company, firm or user shall not alter the frequency, increase the power, or change the characteristics and functions of the original design of the certified lower power frequency electric machinery. Article 14 The application of low power frequency electric machineries shall not affect the navigation safety nor interfere a legal communication, if an interference is found, the service will be suspended until improvement is made and the interference no longer exists.          Declaration of conformity Hereby, Fibar Group S.A. declares that the device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.manuals.fibaro.com WEEE Directive Compliance Device labelled with this symbol should not be disposed with other household wastes. It shall be handed over to the applicable collection point for the recycling of waste electrical and electronic equipment.
Regulations


Adobe PDF Library 15.0 Adobe InDesign CC 2017 (Windows)

Related Documents

Preview FIBARO DIMMER 2 FGD-212 Operating Manual - Smart Home Lighting Control
Comprehensive operating manual for the FIBARO DIMMER 2 (FGD-212), detailing features, installation, Z-Wave integration, operation, specifications, and troubleshooting for smart home lighting.
Preview Fibaro Universal Dimmer 500W (FGD-211) Operating Manual
Comprehensive operating manual for the Fibaro Universal Dimmer 500W (FGD-211). Covers installation, Z-Wave integration, operation, configuration, and troubleshooting for smart home lighting control.
Preview FIBARO Guía del Usuario Avanzado: Automatización del Hogar Inteligente con Z-Wave
Explore el sistema de automatización del hogar FIBARO con esta guía avanzada. Aprenda sobre el protocolo Z-Wave, el Home Center 2, y diversos módulos y sensores para crear un hogar inteligente.
Preview FIBARO Home Intelligence: Advanced Smart Home Automation
Explore the FIBARO Home Intelligence system, a leading smart home automation solution offering unparalleled comfort, security, and energy efficiency. Discover how Z-Wave technology, intuitive interfaces, and intelligent automation can transform your living space.
Preview Z-Wave Protocol Implementation Conformance Statement - Dimmer 2
This document provides the Z-Wave Protocol Implementation Conformance Statement for the Fibaro Dimmer 2, detailing its technical specifications, supported features, and Z-Wave network information.
Preview Fibaro System: Intelligent Home Automation with Z-Wave Technology
Explore the Fibaro System, a leading building automation solution leveraging Z-Wave technology for smart homes. Discover its features, non-invasive installation, user-friendly interface, and benefits for comfort, security, and energy saving.
Preview Fibaro Gateway and Qubino Devices Compatibility Guide
This guide details the compatibility between Fibaro Z-Wave gateways, including HomeCenter 2, HomeCenter 3, HomeCenter 3 Lite, and HomeCenter Lite, and a range of Qubino smart home devices. It outlines the supported functions for each device-gateway combination.
Preview FIBARO Smart Home System: Comprehensive Product Overview and Features
Explore the FIBARO smart home system, its advantages, and a wide range of Z-Wave devices including smart plugs, dimmers, switches, sensors, and controllers for enhanced comfort, safety, and energy efficiency.