Calorex Inverter Heat Pumps

I-PAC 50-100BHC

Heat pumps for commercial swimming pools

Inverter Technology

Inverter technology allows for efficient control of the pool temperature. The I-PAC BHC utilizes only the necessary energy, ensuring high efficiency with a modulating, step-less inverter compressor. This results in an average COP of 10.5 for the I-PAC 100BHC and 10.0 for the I-PAC 50BHC.

Features:

Applications:

Decibel Scale Comparison:

The Calorex I-PAC heat pump operates at a sound level comparable to a refrigerator (50 dB), significantly quieter than many everyday sounds. It offers two modes: Whisper mode for quiet, energy-efficient daily operation and Boost mode for quick start-up heating.

PoolTherm App:

The PoolTherm App for Calorex I-PAC inverter heat pumps is available for Android and iOS. Search for 'PoolTherm' in the App Store or Google Play to download.

Heating Method Efficiency

The chart illustrates that inverter heat pumps offer superior efficiency, consuming half the energy of traditional on/off heat pumps and one-tenth the energy of gas or electric pool heating. This makes them a great value and environmentally conscious heating option.

Temperature Control Chart:

The chart shows how an inverter heat pump maintains a desired pool temperature more consistently than a traditional on/off heat pump, with 'Boost mode' for rapid pool start-up and 'Whisper mode' for steady, quiet operation.

Specifications

Specifications for I-PAC 50BHC and I-PAC 100BHC
Specification Units I-PAC 50BHC I-PAC 100BHC
Performance – air 27°C 80% RH, water 27°C
Heating capacity kW 60.2 115.0
Average COP @50% speed 10.5 10.0
Performance – air 15°C 70% RH, water 26°C
Heating capacity kW 40.1 80.8
Average COP @50% speed 7.0 7.0
Performance – air 45°C 50% RH, water 32°C
Cooling capacity kW 25.1 50.3
Air temperature range °C 0-55 0-55
Power supply V/Hz 400/3ph/50 400/3ph/50
Rated input power kW 2.26-8.90 4.68-17.5
Rated current input A 3.27-12.9 6.78-25.3
Max. input current A 19 38
Water flow m³/h 20-25 40-50
Water connection mm 75 110
Compressor Inverter Inverter
Heat exchanger Titanium Titanium
R410A gas weight and CO2 equivalent kg/tons 8.0/16.70 16/33.41
Sound level @ 1m dB(A) 53-61 55-64
Sound level @ 10m dB(A) 33-41 35-44
Product size (l x w x h) mm 1000 x 1110 x 1260 2100 x 1090 x 1280
Weight kg 247 453

Contact Information

Calorex is part of the Dantherm Group. Various Dantherm Group companies are listed below for contact and support:

Stay updated and follow Calorex on social media. Visit danthermgroup.com for more information.

PDF preview unavailable. Download the PDF instead.

Calorex-I-PAC-50-100BHC-Product-Guide-EN Adobe InDesign 17.0 (Windows) 3-Heights(TM) PDF Optimization Shell 5.9.1.5 (http://www -tools.com)

Related Documents

Preview Calorex I-PAC Inverter Heat Pumps: Owner Installation Manual
This owner installation manual provides comprehensive guidance for the Calorex I-PAC inverter heat pumps, models I-PAC 50/100BLY and I-PAC 50/100BHC. It covers essential safety precautions, detailed installation procedures, operating modes, maintenance schedules, and troubleshooting tips for efficient and reliable pool heating.
Preview Calorex Pro-Pac Heat Pump Installation and Owner's Manual
Comprehensive installation and owner's manual for Calorex Pro-Pac series heat pumps (PPT8, PPT12, PPT16, PPT22). Covers installation, operation, maintenance, troubleshooting, and warranty information for swimming pool heating systems.
Preview Calorex DH75/DH110 Range Installation Instructions
This document provides installation instructions for the Calorex DH75 and DH110 range of dehumidifiers. It covers essential safety warnings, step-by-step installation procedures, electrical and LPHW connections, operational guidelines, troubleshooting tips, and detailed technical specifications.
Preview Calorex AW Series Air/Water Heat Pump Owner Installation Manual
This manual provides comprehensive installation, operation, and maintenance guidance for the Calorex AW631, AW831, AW1231, and AW1531 air/water heat pumps designed for swimming pools. It covers siting, plumbing, electrical connections, controls, troubleshooting, data sheets, and winterising procedures.
Preview Calorex VPX/VPX-T 33-55-77 Service Instructions and Technical Data
Comprehensive service instructions, technical specifications, installation guides, and troubleshooting for Calorex VPX and VPX-T 33-55-77 dehumidifiers from Dantherm Group.
Preview Calorex PLENUS Instant Water Heater: Installation, Operation, and Maintenance Manual
Comprehensive guide for the Calorex PLENUS instant water heater, covering installation, operation, maintenance, troubleshooting, and warranty. Includes model details for PLENUS 07 L, 11 L, and 13 L.
Preview Calorex Through-the-Wall Dehumidifier Technical Manual
This technical manual provides comprehensive information for Calorex Through-the-Wall Dehumidifiers, including installation details, data sheets, wiring diagrams, performance graphs, dimensions, spare parts lists, optional kits, and warranty conditions. It is intended for competent persons involved in the installation and maintenance of these units.